Document XRor8p5zb3daeJGLmQNQZgoMg
NiCDN
INTERNAL
I
CORRESPONDENCE
4BIDE COFFGFATCN -=c-nic.=.l get
^ C ECX "3G ^ . S
RECEIVE
NOV 8 2 1983
y/V 253C3
D. R. Paugh 511-2009 512
c. P. Maxwell M. L . Mills L. R. Noble R. E. Peele R. W. Scoular
November 22. 1983
- - -
511 Industrial Hygiene/ Environmental Protection
1984 Industrial Hygiene Program for 511 Construction Department
Dear Mr. Paugh:
I am enclosing an Industrial Hygiene Program for 1984 as it relates to 511 Construction Department.
This program is by no means exclusive. We will be making necessary adjustments during the year if required.
If I can be of any assistance in this matter, please feel free to call me at extension 3750.
Very truly yours,
rn^wtU-V^W
Manhar A. Patel
MAP/sc
Attachment
UJ-S
UCC 017241
PLAINTIFF'S EXHIBIT UC-3429
1984 INDUSTRIAL HYGIENE PROGRAM FOR
511 CONSTRUCTION DEPARTMENT
CHEMICAL EXPOSURE MONITORING A. Welding Fumes (e.g., Fe, Cd, Al. Cr,
Ni# Cu, Zn) Pipe Fab Shop
Personal exposure monitoring. Metal Fab Shop
Personal exposure monitoring. Modular Shop
Personal exposure monitoring. B. Metals Other Than Welding
Galvanizing Shop (lead, zinc) Personal exposure monitoring.
Field Lead Pipe Joints Personal exposure monitoring.
C. Dust Insulation Shop Area and personal exposure monitoring. Blasting Shed Area and personal exposure monitoring. Modular Shop Area and personal exposure monitoring.
D. Isocyanates Insulation Shop Personal and area exposure monitoring.
FREQUENCY
Once per year Once per year Once per year
Once per year As needed
Once per year Once per year Once per year
Once per year
UCC 017242
I. CHEMICAL EXPOSURE MONITORING (continued) E. Methylene Chloride Insulation Shop Area and personal exposure monitoring. F. Methyl Ethyl Ketone Paint Shop Blasting Shed Modular Shop G. 1,1,1-Trichloroethane Welding Shops H. Nitrogen Dioxide Metal Fab Shop Area and personal exposure monitoring. Pipe Fab Shop Area and personal exposure monitoring. I. Ozone Metal Fab Shop Area monitoring. Pipe Fab Shop Area monitoring. J. Asbestos Storeroom Area and personal exposure monitoring. In The Field Area and personal exposure monitoring. K. Other chemicals will be monitored in the workplace depending upon the knowledge of their use, evaluation of the situation and availability of technology for measurement.
FREQUENCY
Once per year Once per year Once per year Once per year Once per year
Once per year Once per year
Once per year Once per year
Once per year As needed
2- UCC 017243
II. NOISE
FREQUENCY
Pipe Fab Shop
Metal Fab Shop
Carpenter Shop
Heavy Equipment
Area and personal exposure monitoring.
Once in 1984
III. MICROWAVE OVENS
IH will maintain inventory of all microwave ovens within Location 511.
All microwave ovens will be surveyed for leaks.
Twice per year
IV. VENTILATION
All ventilation systems within the Construction
Department will be surveyed.
Once per year
V. BREATHING AIR QUALITY CHECK
All air cylinders used for respiratory protection will be checked for quality.
As needed
VI. DEVELOP HEALTH HAZARD AND PROTECTION INFORMATION FOR CHEMICALS USED WITHIN SHOPS OR OUTSIDE.
As needed
VII. PARTICIPATE IN SAFETY REVIEWS
As needed
VIII. UPDATE AND MAINTAIN LISTS
A. Carcinogen List
Keep evergreen
B. Embryo-Fetus Protection List
IX. TRAINING
A. Noise
Provide assistance to 511 Safety Department.
As needed
B Embryo-Fetus Protection
As needed
C. Other Training
As needed
X. AUDIT OF WEST VIRGINIA POSTING REGULATION
Twice per year
-3UCC 017244