Document XRor8p5zb3daeJGLmQNQZgoMg

NiCDN INTERNAL I CORRESPONDENCE 4BIDE COFFGFATCN -=c-nic.=.l get ^ C ECX "3G ^ . S RECEIVE NOV 8 2 1983 y/V 253C3 D. R. Paugh 511-2009 512 c. P. Maxwell M. L . Mills L. R. Noble R. E. Peele R. W. Scoular November 22. 1983 - - - 511 Industrial Hygiene/ Environmental Protection 1984 Industrial Hygiene Program for 511 Construction Department Dear Mr. Paugh: I am enclosing an Industrial Hygiene Program for 1984 as it relates to 511 Construction Department. This program is by no means exclusive. We will be making necessary adjustments during the year if required. If I can be of any assistance in this matter, please feel free to call me at extension 3750. Very truly yours, rn^wtU-V^W Manhar A. Patel MAP/sc Attachment UJ-S UCC 017241 PLAINTIFF'S EXHIBIT UC-3429 1984 INDUSTRIAL HYGIENE PROGRAM FOR 511 CONSTRUCTION DEPARTMENT CHEMICAL EXPOSURE MONITORING A. Welding Fumes (e.g., Fe, Cd, Al. Cr, Ni# Cu, Zn) Pipe Fab Shop Personal exposure monitoring. Metal Fab Shop Personal exposure monitoring. Modular Shop Personal exposure monitoring. B. Metals Other Than Welding Galvanizing Shop (lead, zinc) Personal exposure monitoring. Field Lead Pipe Joints Personal exposure monitoring. C. Dust Insulation Shop Area and personal exposure monitoring. Blasting Shed Area and personal exposure monitoring. Modular Shop Area and personal exposure monitoring. D. Isocyanates Insulation Shop Personal and area exposure monitoring. FREQUENCY Once per year Once per year Once per year Once per year As needed Once per year Once per year Once per year Once per year UCC 017242 I. CHEMICAL EXPOSURE MONITORING (continued) E. Methylene Chloride Insulation Shop Area and personal exposure monitoring. F. Methyl Ethyl Ketone Paint Shop Blasting Shed Modular Shop G. 1,1,1-Trichloroethane Welding Shops H. Nitrogen Dioxide Metal Fab Shop Area and personal exposure monitoring. Pipe Fab Shop Area and personal exposure monitoring. I. Ozone Metal Fab Shop Area monitoring. Pipe Fab Shop Area monitoring. J. Asbestos Storeroom Area and personal exposure monitoring. In The Field Area and personal exposure monitoring. K. Other chemicals will be monitored in the workplace depending upon the knowledge of their use, evaluation of the situation and availability of technology for measurement. FREQUENCY Once per year Once per year Once per year Once per year Once per year Once per year Once per year Once per year Once per year Once per year As needed 2- UCC 017243 II. NOISE FREQUENCY Pipe Fab Shop Metal Fab Shop Carpenter Shop Heavy Equipment Area and personal exposure monitoring. Once in 1984 III. MICROWAVE OVENS IH will maintain inventory of all microwave ovens within Location 511. All microwave ovens will be surveyed for leaks. Twice per year IV. VENTILATION All ventilation systems within the Construction Department will be surveyed. Once per year V. BREATHING AIR QUALITY CHECK All air cylinders used for respiratory protection will be checked for quality. As needed VI. DEVELOP HEALTH HAZARD AND PROTECTION INFORMATION FOR CHEMICALS USED WITHIN SHOPS OR OUTSIDE. As needed VII. PARTICIPATE IN SAFETY REVIEWS As needed VIII. UPDATE AND MAINTAIN LISTS A. Carcinogen List Keep evergreen B. Embryo-Fetus Protection List IX. TRAINING A. Noise Provide assistance to 511 Safety Department. As needed B Embryo-Fetus Protection As needed C. Other Training As needed X. AUDIT OF WEST VIRGINIA POSTING REGULATION Twice per year -3UCC 017244