Document XRZXdd8X9K6wkY3mJEjLVzYeB

ABD00088841 Name: A1lman Next test due: TS1 MODEL 8015 PORTACOUNT FIT-TESTING SOFTWARE Version 2.01 S/N 927 VISTA POLYMERS FIT TEST REPORT Test dates Test time: Test subject last name: Test subject first name: ID number: Operator name: Next fit test due: Test agent: Test device: 10-02-1994/ 10:29:14 am A1lman Paul 416705023 Walker Ambient particles TSI MODEL 8010 PORTACOUNT RESPIRATOR ID Size: Model: Manufacturer: Approval number: Large 3M TC-21C-488 Additional notes: Additional notes: TEST DATA Ex. Ambient (Part/cc) Pass/Fail level: 100 Test cycles....: 1 Mask Fit Factor (Part/cc) Pass/Fail NB 1860 2.800 DB 1885 0.930 SS 1895 3.870 UD 1855 9.590 R 1825 20.900 NB 1800 4.220 665 2030 491 194 87.2 427 PASS PASS PASS PASS FAIL PASS OVERALL FIT FACTOR = 261 (Calculated per ANSI Z88.2-1980) PASS Date Date /<> ~ X