Document XRBBndBKd2dQ9b2wgZ8Y4bEEJ
American Society of Heating and Ventilating Engineers Guide, 1926-27
No additional allowance need be made for covered mains or risers, but exposed mains or risers used as heating surfaces should be included in calculating the equivalent square feet of direct radiation.
PUMP SPECIFICATIONS
Reciprocating and power driven pumps should be specified as to make, size, water and steam working pressures, piston speed, temperature of water to be handled, electric motor characteristics and the trade standard, required in accordance with the manufacturers' adoptions, copy of which is appended to this section of the code for reference.
Table 77. Motor Driven Condensation Pump Capacities for Delivering Against Various Pressures
Radia
tion in
Sq. Ft. of Direct Radia
Minimum
Gallons per Min.
Maximum
Boiler Motor Pressure H. P.
Lb.
tion
4000 4000 4000
6-8 6-8 6-8
10
15-40
50-60
KX
X
6000 6000 6000
9-12 9-12 9-12
10
15-40
50-60
K
X
l
8000 8000 8000 8000
1111100000,,,,,000000000000000
12-16 12-16 12-16 12-16
15-20 15-20 15-20 15-20 15-20
10 2105
30-60
10
IS
20-30 30-40 50-60
X
l
m
Y> X
l
2ik
Sug
gested
Size of Piping Inches
i
i i
IX m IX
mIIIKKK iiIiKKKK
m
Radia
tion in
Sq. Ft. of Direct Radia
tion
Minimum Gallons
per Min.
Maximum
Boiler Motor Pressure H. P.
Lb.
15,000 15,000
15,000
15,000
222221000005,,,,,,000000000000000000
25,000
25,000 25,000
25-30 25-30 25-30 25-30 25-30 30-40 30-40 30-40 30-40 30-40 40-50 40-50 40-50
10
15 20-30 40
5100-60 2105
3040
5100-60 2105
K
l
2I.K
3
K 2l
3
51 2IK
25,000 25,000 30,000 30,000 30,000
40-50 40-50 50-60 50-60 50-60
30-40
5100-60 2105
3
51 2IK
30,000 50-60 30-60 5
Sug
gested
Size of Piping Inched
2222222222 22KK 2222222KKKKKKK
The kind of drive should be specified for power driven pumps. Centrifugal and Rotary pumps should be specified as to make, type, capacity temperature of water to be handled, speed and motor charac teristics including:
1. Name of motor manufacturer 2. Manufacturers rated Horse Power 3. The maximum temperature rise for any part of the motor above the temperature of the surrounding air 4. Full Speed in R. P. M. 5. Current characteristics 6. Whether the motor is open, semi-enclosed or fully enclosed.
The following should also be included in the specifications, total head to be pumped against including suction lift friction head, velocity head
140
American Society of Heating and Ventilating Engineers Guide, 1926-27
Table 78. One Pump One Motor Return Line System
Size
A B C D E F G H
Sq. Ft. - Direct Equivalent Radiation
Surface
Diameter Orifice Vacuum
10 IN.
Air Capacity
Cu. Ft. per Min.
8000 16,000 26,000 40.000 65.000 100,000 150.000 250.000
9-64 3-16 1-4 9-32 3-8 1-2 9-16 Three 1-2
6 11 19 25 42 75 90 180
Water Capacity
Gals, per Min. 10 Lb. Pres sure 180 F.
ii 22 35 60 90 140 200 400
ACTUAL H. P.
0.9 1.4 2.0 2.8 3.9 9.0 10.0 10.0
R. P. M.
H. P. of Motor
1800 1800 1800 1200 1200 1200
900 720
i
IK
'2 3 5 10 10 20
Table 79. Two Pump One Motor Return Line System Vacuum Pumps
Capacity Sq. Ft.
of
Direct Radiation
6000 6000 8000 8000 12,000 12,000 18,000 18,000 30,000 30,000
Capacity G. P. M.
9 9 12 12 18 18 27 27 45 45
Pressure at Pump
10 15 10
1to5
15 10 15 10 15
Motor H. P.
X
1
1lIK liKK
2 2 3
Table 80. Two Pump Two Motor Return Line System Vacuum Pump
Capacity Sq. Ft. of Capacity G. P. M.
Direct Radiation
Pressure at Pimp
6000 6000 . 8000 8000 12,000 12,000 18,000 18,000 25,000 25,000
30;000 30,000
9 9 12 12
18 18 27 27
38 38 45 45
10 15 10 15 10 15 10 15 10
15 10 15
Motor H.
KKK
X X. X X
l l l l
Water
x
X X
.l
X
l 1 -2
u*
2
ik
2 ,,
and head against which the pump must discharge. The vacuum under which return pumps-are required to operate and as to whether two or more units are to operate in parallel or separately.