air C8 recheck
PARSONMA
fts shown in the Table below, all air samples collected 7-29-98 appear
to contain appreciable levels of C-8 except for the blank. These samples were analyzed with fresh reagent (from a new shipment that arrived late Wednesday). In addition to the "blank" Tenax tube, three additional blanks were examined. All blanks showed essentially clean baselines which verify the purity of the reagent. The GC response at retention time of "3.7 minutes (corr C8 pk) is shown to emphasize the levels of C8 observed.
Table 1; C-8 in Air
SAMPLE
corr
LOCATION
A
smoking area? 162 roof
Liters
C8 pk
18547
of air
50.7
ug C8 0.738
Bl
blank tube
1309
44.2
0
Cl top of SW stairs, unit side
37058
52.3
1.545
01
SB rail
32870
45.6
1.363
E mid-rail, North
23812
48.2
0.968
mpb C8
0.82
0
1.66
1.67 1.13
Table 2t Calibration results
corr Standard
blank (0 ug)
0.1 ug standard 0.5 ug standard 1.0 ug standard
C8 pk.
693
4090
14539 23797
Slope;
22948
intercept; 1600
R-2;
0.989
It should be stressed that although the electron capture detector
(BCD) used in this GC method is extremely sensitive for fluorinated
species (e.g. "C-8"), it is incapable of providing positive
(qualitative) identification of analytes. It is theoretically
possible that. the response (peak) interpreted as "c-8" is another substance
^
(or mixture) which co-elutes with C-8.
^
>--*
K>
Recommend additional samples be collected ASAP. Duplicates should be
"^
obtained where possible as we are still working to improve robustness
>->
EID937318
of this method and understand run-to-run variations.
SP
EID937319