Document XQ5eJRR6qO5Ka9qwG0Gyk6wx
1 )
IN 1971 MONSANTO DISCONTINUED SALE OF PCB-CONTAINING PRODUCTS TO THE FOLLOWING MAJOR APPLICATION AREAS:
-CARBONLESS PAPER -FIRE RESISTANT HYDRAULIC FLUIDS -HEAT TRANSFER -PLASTICIZER
MOMS
THERE WERE NUMEROUS MINOR ADDITIONAL APPLICATIONS DISCONTINUED AT THE SAME TIME.
MONS 043773
SALES IN THESE AREAS FELL FROM 32.5M LBS. IN 1970 TO 752,000 LBS. IN 1972 and 0 IN 1973.
MONS 043774
IN 1975 WE CONTINUE TO SELL TO THE ELECTRICAL INDUSTRY FOR INCLUSION IN CAPACITORS, TRANSFORMERS AND ASSOCIATED CLOSED ELECTRICAL EQUIPMENT BECAUSE -
HONS 043775
1. UTILITY - THE AROCLOR FLUIDS PERFORM AN ESSENTIAL ROLE IN ELECTRICAL DISTRIBUTION.
2. LACK OF EFFECTIVE PROVEN REPLACEMENT. 3. OUR BELIEF THAT USE IN CLOSED SYSTEMS
IS CONTROLLABLE.
BQ>*S 0^llb
MONSANTO CURRENT MARKETING POLICY - PCB 1. SUPPLY ONLY MANUFACTURERS OF SEALED ELECTRICAL
EQUIPMENT SUCH AS CAPACITORS/TRANSFORMERS. 2. DO NOT RECLAIM ELECTRICAL FLUIDS. 3. OFFER INCINERATION SERVICE FOR LIQUID PCB WASTES. 4. CONTINUE RESEARCH PROGRAM (STARTED 1969) TO DEVELOP
EFFECTIVE REPLACEMENTS. 5. ENSURE THAT SIGNIFICANT DIFFERENCES BETWEEN AROCLOR
DIELECTRICS AND REPLACEMENT CANDIDATES ARE FULLY REVIEWED.
MONS 043 77 7
UTILITY IN CAPACITORS
PROPERTY
FUNCTION
FIRE RESISTANCE ------------------^ CONSUMER/PLANT SAFETY
THERMAL STABILITY CHEMICAL STABILITY ---------- RELIABILITy HYDROLYTIC STABILITY POWER FACTOR
DIELECTRIC CONSTANT DIELECTRIC STRENGTH
, AVAILABILITY ' CONVERTABILITY
ECONOMY
HUNS 043778
UTILITY IN TRANSFORMERS
FIRE RESISTANCE
SAFETY
THERMAL/CHEMICAL STABILITY
RELIABILITY
HONS IH3779
TRANSFORMER APPLICATIONS 1. RAILROAD TRANSFORMERS - RAPID TRANSIT SYSTEMS. 2. URBAN SUBSTATIONS. 3. INDUSTRIAL LOAD CENTERS. 4. ELECTROSTATIC PRECIPITATORS.
MONS 043780
FIRE RESISTANCE OF ASKAREL TRANSFORMERS 1. FIRE INITIATION. 2. ARC FORMED GASES. 3. FIRE PROPAGATIONS.
MQNS 043781
11
POTENTIAL SUBSTITUTES CAPACITORS
RESEARCH OBJECTIVES
1. MATCH OR EXCEED AROCLOR 1016 CAPABILITY.
A) DIELECTRIC CONSTANT DIELECTRIC STRENGTH
_ AVAILABILITY ~ CONVERTABILITY
B) STABILITY POWER FACTOR
C) SAFETY
_ RELIABILITY - FIRE RESISTANCE
2. IMPROVE FURTHER-ENVIRONMENTAL COMPATIBILITY.
3. A) SPAN EXISTING APPLICATIONS - COMPLETE SOLUTION. B) INTERNATIONALLY AVAILABLE - NOT SOLELY USA SITUATION.
MONS 043782
12 MONS 043783
THE CAPACITOR INDUSTRY IS CURRENTLY EXAMINING MCS I23B MCS 1588 MCS 1475.
1. THESE CONTAIN NO CHLORINATED BIPHENYL. 2. ALL THESE REPRESENT A SINGLE CONCEPT.
HONS 043784
14
THE ADDITION OF A LIMITED QUANTITY OF VERY HIGH DIELECTRIC CONSTANT FLUID TO A GOOD DIELECTRIC BASE LIQUID TO GIVE A DIELECTRIC MIXTURE "EQUIVALENT" ELECTRICALLY TO AROCLOR 1016.
HONS 043785 II
1. MCS 1236 = HYDROCARBON + SULFONE. 2. MCS 1568 = HYDROCARBON + SULFONE. 3. MCS 1475 - PHTHALATE ESTER + SULFONE THE MAIN THRUST TODAY IS TOWARDS PRODUCTS 1 & 2.
MONS 043786
PROPERTY DK 25*C
100" C
CORONA IV/BV
AROCLOR 1016 5.9 4.85
INDUSTRY
HYDROLYSIS STABILITY* (NEUTRALIZATION NUMBER)
DISSIPATION FACTOR. FLUID TAN 8 6OH2 100C
DISSIPATION FACTOR.MODEL CAPACITOR
0.00 0.0025 0.0034
MCS 1238 6.0 5.1 INDUSTRY
0.00 0.05 0.0039
16 MCS 1588
6.1 5.1 INDUSTRY
0.00
0.05
0.0035
YBYF40 SNOW
*SEE TEXT
FLASH PT. F. FIRE PT. "F. AIT. F.
FIRE RESISTANCE
AROCLOR 1016
MCS 1238
358
303
NONE TO BOILING PT. (620)
328
1185"
835"
MCS 1588 325" 350"
870"
HONS 0*3788
CONCLUSION MONSANTO CANDIDATES ARE NOT FIRE RESISTANT.
MONS 0437B9
ENVIRONMENTAL CONSIDERATIONS
EXPOSURE
BIODEGRADATION
ACCUMULATION TOXICITY
WORKER SAFETY ENVIRONMENTAL IMPACT
MQNS 0*3790
% BIODEGRADATION
SCAS.
AROCLOR 1254 AROCLOR 1016
48 HR. 15 33
MCS 1238
78
HYDROCARBON
90
SULFONE
52
160 HR. s jpm JPM
86 90 78
HONS 043791
RAT TISSUE RESIDUE (JPM) MONS 043792
26 MONS 043793
TOXICITY STUDIES -MCS 1238 IN-PLANT HANDLING
1. RAT - ACUTE SINGLE ORAL DOSE LD50 - 3800 MGS/KG. 2. EYE IRRITATION - RABBIT - 12.0/110.0
NORMAL AFTER 72 HOURS. 3. RABBIT - DERMAL LD50 - 5.0-8.0 GMS PER KILOGRAM. 4. RABBIT - SKIN IRRITATION (24 HR. CONTACT) - 3.6/8.0.
MONS 043794
2t
ENVIRONMENTAL IMPACT
1 DEGRADATION
s
2 ACCUMULATION /
3. FISH TOXICITY - 4 DAY STATIC STUDY - 96 HOUR LC50 RAINBOW TROUT - 2.0 PPM BLUE GILL - 3.2 PPM
MONS 043795
MCS 1238 - FURTHER PROGRAMS SCHEDULED 1. VAPOR INHALATION. 2. ULTIMATE DEGRADATION. 3. ARC GASES. 4. PILOT FEEDING STUDY. 5. LONG-TERM (2 YEAR) FEEDING STUDIES. 6. FISH TISSUE RESIDUES.
HONS 043796
STAGE
T
CAPACITOR REPLACEMENT 27
MONSANTO
SCREEN (ELEC) MULTIPLE FLUID
A.SELECT f B.SCREEN(TOX.)
PRELIM.
__ . BROADEN ENVIRONMENTAL | * SCREEN
INDUSTRY
MULTIPLE APPLICATION
h SCREEN
AGENCIES
CONSIDER SAFETY ASPECTS
lb L t*> 0 SNOH
TRANSFORMERS WE HAVE NOT DEVELOPED ANY MATERIAL WITH EQUIVALENT FIRE RESISTANCE TO AROCLOR. A. PROTECTION UNDER TRANSFORMER FAULT
CONDITIONS. B. ARC FORM GASES C. POTENTIAL SPREAD OF EXTERNAL FIRE.
RONS 0437"
WE DO HAVE CANDIDATES WITH INTERMEDIATE FIRE RESISTANCE
HONS 043799
PROPERTY
MCS
MCS
MCS
MONS 043800
OUR MAJOR OBSTACLE ABSENCE OF OBJECTIVE STANDARDS TO GUIDE
POTENTIAL FLUID SUPPLIER TRANSFORMER PRODUCERS TRANSFORMER USERS INSURANCE GROUPS SAFETY ORGANIZATIONS GOVERNMENT AGENCIES ON REQUIRED LEVEL OF FIRE RESISTANCE.
MONS 043801