Document XQ5eJRR6qO5Ka9qwG0Gyk6wx

1 ) IN 1971 MONSANTO DISCONTINUED SALE OF PCB-CONTAINING PRODUCTS TO THE FOLLOWING MAJOR APPLICATION AREAS: -CARBONLESS PAPER -FIRE RESISTANT HYDRAULIC FLUIDS -HEAT TRANSFER -PLASTICIZER MOMS THERE WERE NUMEROUS MINOR ADDITIONAL APPLICATIONS DISCONTINUED AT THE SAME TIME. MONS 043773 SALES IN THESE AREAS FELL FROM 32.5M LBS. IN 1970 TO 752,000 LBS. IN 1972 and 0 IN 1973. MONS 043774 IN 1975 WE CONTINUE TO SELL TO THE ELECTRICAL INDUSTRY FOR INCLUSION IN CAPACITORS, TRANSFORMERS AND ASSOCIATED CLOSED ELECTRICAL EQUIPMENT BECAUSE - HONS 043775 1. UTILITY - THE AROCLOR FLUIDS PERFORM AN ESSENTIAL ROLE IN ELECTRICAL DISTRIBUTION. 2. LACK OF EFFECTIVE PROVEN REPLACEMENT. 3. OUR BELIEF THAT USE IN CLOSED SYSTEMS IS CONTROLLABLE. BQ>*S 0^llb MONSANTO CURRENT MARKETING POLICY - PCB 1. SUPPLY ONLY MANUFACTURERS OF SEALED ELECTRICAL EQUIPMENT SUCH AS CAPACITORS/TRANSFORMERS. 2. DO NOT RECLAIM ELECTRICAL FLUIDS. 3. OFFER INCINERATION SERVICE FOR LIQUID PCB WASTES. 4. CONTINUE RESEARCH PROGRAM (STARTED 1969) TO DEVELOP EFFECTIVE REPLACEMENTS. 5. ENSURE THAT SIGNIFICANT DIFFERENCES BETWEEN AROCLOR DIELECTRICS AND REPLACEMENT CANDIDATES ARE FULLY REVIEWED. MONS 043 77 7 UTILITY IN CAPACITORS PROPERTY FUNCTION FIRE RESISTANCE ------------------^ CONSUMER/PLANT SAFETY THERMAL STABILITY CHEMICAL STABILITY ---------- RELIABILITy HYDROLYTIC STABILITY POWER FACTOR DIELECTRIC CONSTANT DIELECTRIC STRENGTH , AVAILABILITY ' CONVERTABILITY ECONOMY HUNS 043778 UTILITY IN TRANSFORMERS FIRE RESISTANCE SAFETY THERMAL/CHEMICAL STABILITY RELIABILITY HONS IH3779 TRANSFORMER APPLICATIONS 1. RAILROAD TRANSFORMERS - RAPID TRANSIT SYSTEMS. 2. URBAN SUBSTATIONS. 3. INDUSTRIAL LOAD CENTERS. 4. ELECTROSTATIC PRECIPITATORS. MONS 043780 FIRE RESISTANCE OF ASKAREL TRANSFORMERS 1. FIRE INITIATION. 2. ARC FORMED GASES. 3. FIRE PROPAGATIONS. MQNS 043781 11 POTENTIAL SUBSTITUTES CAPACITORS RESEARCH OBJECTIVES 1. MATCH OR EXCEED AROCLOR 1016 CAPABILITY. A) DIELECTRIC CONSTANT DIELECTRIC STRENGTH _ AVAILABILITY ~ CONVERTABILITY B) STABILITY POWER FACTOR C) SAFETY _ RELIABILITY - FIRE RESISTANCE 2. IMPROVE FURTHER-ENVIRONMENTAL COMPATIBILITY. 3. A) SPAN EXISTING APPLICATIONS - COMPLETE SOLUTION. B) INTERNATIONALLY AVAILABLE - NOT SOLELY USA SITUATION. MONS 043782 12 MONS 043783 THE CAPACITOR INDUSTRY IS CURRENTLY EXAMINING MCS I23B MCS 1588 MCS 1475. 1. THESE CONTAIN NO CHLORINATED BIPHENYL. 2. ALL THESE REPRESENT A SINGLE CONCEPT. HONS 043784 14 THE ADDITION OF A LIMITED QUANTITY OF VERY HIGH DIELECTRIC CONSTANT FLUID TO A GOOD DIELECTRIC BASE LIQUID TO GIVE A DIELECTRIC MIXTURE "EQUIVALENT" ELECTRICALLY TO AROCLOR 1016. HONS 043785 II 1. MCS 1236 = HYDROCARBON + SULFONE. 2. MCS 1568 = HYDROCARBON + SULFONE. 3. MCS 1475 - PHTHALATE ESTER + SULFONE THE MAIN THRUST TODAY IS TOWARDS PRODUCTS 1 & 2. MONS 043786 PROPERTY DK 25*C 100" C CORONA IV/BV AROCLOR 1016 5.9 4.85 INDUSTRY HYDROLYSIS STABILITY* (NEUTRALIZATION NUMBER) DISSIPATION FACTOR. FLUID TAN 8 6OH2 100C DISSIPATION FACTOR.MODEL CAPACITOR 0.00 0.0025 0.0034 MCS 1238 6.0 5.1 INDUSTRY 0.00 0.05 0.0039 16 MCS 1588 6.1 5.1 INDUSTRY 0.00 0.05 0.0035 YBYF40 SNOW *SEE TEXT FLASH PT. F. FIRE PT. "F. AIT. F. FIRE RESISTANCE AROCLOR 1016 MCS 1238 358 303 NONE TO BOILING PT. (620) 328 1185" 835" MCS 1588 325" 350" 870" HONS 0*3788 CONCLUSION MONSANTO CANDIDATES ARE NOT FIRE RESISTANT. MONS 0437B9 ENVIRONMENTAL CONSIDERATIONS EXPOSURE BIODEGRADATION ACCUMULATION TOXICITY WORKER SAFETY ENVIRONMENTAL IMPACT MQNS 0*3790 % BIODEGRADATION SCAS. AROCLOR 1254 AROCLOR 1016 48 HR. 15 33 MCS 1238 78 HYDROCARBON 90 SULFONE 52 160 HR. s jpm JPM 86 90 78 HONS 043791 RAT TISSUE RESIDUE (JPM) MONS 043792 26 MONS 043793 TOXICITY STUDIES -MCS 1238 IN-PLANT HANDLING 1. RAT - ACUTE SINGLE ORAL DOSE LD50 - 3800 MGS/KG. 2. EYE IRRITATION - RABBIT - 12.0/110.0 NORMAL AFTER 72 HOURS. 3. RABBIT - DERMAL LD50 - 5.0-8.0 GMS PER KILOGRAM. 4. RABBIT - SKIN IRRITATION (24 HR. CONTACT) - 3.6/8.0. MONS 043794 2t ENVIRONMENTAL IMPACT 1 DEGRADATION s 2 ACCUMULATION / 3. FISH TOXICITY - 4 DAY STATIC STUDY - 96 HOUR LC50 RAINBOW TROUT - 2.0 PPM BLUE GILL - 3.2 PPM MONS 043795 MCS 1238 - FURTHER PROGRAMS SCHEDULED 1. VAPOR INHALATION. 2. ULTIMATE DEGRADATION. 3. ARC GASES. 4. PILOT FEEDING STUDY. 5. LONG-TERM (2 YEAR) FEEDING STUDIES. 6. FISH TISSUE RESIDUES. HONS 043796 STAGE T CAPACITOR REPLACEMENT 27 MONSANTO SCREEN (ELEC) MULTIPLE FLUID A.SELECT f B.SCREEN(TOX.) PRELIM. __ . BROADEN ENVIRONMENTAL | * SCREEN INDUSTRY MULTIPLE APPLICATION h SCREEN AGENCIES CONSIDER SAFETY ASPECTS lb L t*> 0 SNOH TRANSFORMERS WE HAVE NOT DEVELOPED ANY MATERIAL WITH EQUIVALENT FIRE RESISTANCE TO AROCLOR. A. PROTECTION UNDER TRANSFORMER FAULT CONDITIONS. B. ARC FORM GASES C. POTENTIAL SPREAD OF EXTERNAL FIRE. RONS 0437" WE DO HAVE CANDIDATES WITH INTERMEDIATE FIRE RESISTANCE HONS 043799 PROPERTY MCS MCS MCS MONS 043800 OUR MAJOR OBSTACLE ABSENCE OF OBJECTIVE STANDARDS TO GUIDE POTENTIAL FLUID SUPPLIER TRANSFORMER PRODUCERS TRANSFORMER USERS INSURANCE GROUPS SAFETY ORGANIZATIONS GOVERNMENT AGENCIES ON REQUIRED LEVEL OF FIRE RESISTANCE. MONS 043801