Document XOwGZjNdXyKy7QervZRGGOYpd
FILE NAME Allied Signal Bendix ASB
DATE 1987 Feb 26
DOC ASB091
DOCUMENT DESCRIPTION Memo RE Asbestos Program - Compression
Mold Area Feb 25 1987
e
4 es
Memorandum
Bendix
Bendix FrictionFriction Materials Division Green Island New York
PLAINTIFF'S
80-63189 EXHIBIT
PENGAD
Date February February 26 1987
To : S. Scott Scott From C. Larson Larson
Subject : Asbestos Asbestos Program - Compression Mold Area - February 25 1987
A walk through the compression mold area with J. Skidmore and J. Herman Herman Sector resulted in the following observations
Many work stations with vacuum capability were not as clean as one would expect for several reasons
1.
Vacuum hoses did not have attachments which would substan-
tially increase cleaning efficiency of the vacuum system
2
Administrative procedures supervision and enforcement of
the administrative procedures are not as effective as they
should be to enforce cleaning time that is being provided to
the operators
3
In order to achieve cleaner work stations the operators
have to be provided the equipment to do so Someone has to
initiate and follow through on obtaining the necessary
cleaning equipment attachments etc. in order to maintain
work station cleanliness
4.
Various high vacuum hoses were left open to atmosphere
thereby reducing operating efficiency at other high vacuum
locations
Visible accumulations were evident but some possibly could be attributable to not having proper cleaning equipment leaks in
duct work resulting in particulate raining upon equipment and inefficient dust collector pick lines on various pieces of
equipment Operator work practice could be improved to reduce fugitive emissions from the work station thereby reducing
employee exposure
There was various pieces of equipment and work stations which were without vacuum capability and had asbestos accumulations that were quite old Book truck frames for example had sub-
stantial build ups that have to be removed Book truck storage
areas showed recent evidence of being vacuumed but could be
22671
WCK017297
February 26 Page -2-
1987
improved if the vacuum hoses had proper attachments to enhance
vacuum efficiency There does not appear to be someone responsible for these no man's areas This has to be assigned to someone to insure proper cleaning of these areas
Dust collector duct leaked in several areas near the drills
{
Bolted work seams should be tightened or possibly the
installation of gaskets would insure duct work integrity Some
of the equipment visible accumulations may be the result of ducts
leaking therefore investigation of visible accumulations should
include work integrity inspections
Just about every drill we visited had dust collector pick line
I
hoding problems such as improper placement damaged pick nozzles
insufficient hooding around equipment and pick lines which
left
to atmosphere but not being utilized because the
were
open
obvious dust collector
specific hood was not required These are
maintenance problems and should be part of a continuing preventa-
t
for the dust collectors
It is my
|
tive maintenance program
opinion that failure to maintain
dust
collector
pick at the
a willful
machines could be viewed by an OSHA inspector as
we violation resulting in grave consequences Based upon this
it is strongly recommended that all work
cursory inspection stations are inspected to
insure that all
pick
lines
etc. are because
in proper operating condition This should be a priority
it is quite possible that OSHA could conduct a facility inspec-
i
tion in the near future
There were obvious signs that there was insufficient vacuum
Since the present vacuum system is
cleaning capability
cleaners is
fully extended the purchase of portable vacuum
at the
recommended to provide the additional vacuum capability
work stations where high vacuum lines are not available Work
stations without vacuum capability were obviously not as clean as
the work stations with vacuum capability
Recommendations
1
Purchase the necessary vacuum hose attachments in order to
enhance cleaning efficiency
2 Review administrative procedures to assure that operators
are cleaning their work stations as required
3 Inspect all dust collector work and repair all leaks
ie gasket installation at flanges if needed
4 Inspect all dust collector pick review all pick
against
equipment
drawings
repair as
for
needed and institute
the equipment at the
preventative maintenance programs
work station
22671
WCK017298
February 26 1987 Page -3-
5
Purchase portable vacuums for work stations without vacuum
capability and assign no man's land areas to insure
cleaning of these areas
6
Suggest weekly tour by management to insure that
administrative procedures housekeeping and dust collector
maintenance is being maintained at best management prac-
tices
;
7
Since Troy and Cleveland are ranked no 1 and no 3 by EPA
in asbestos risk assessment I am quite sure that our two
facilities will be high on the hit list by OSHA to conduct
enforcement inspections Based upon this insight I strongly urge that routine maintenance operating procedures and purchase of equipment be performed in order to insure proper
protection of the employee
CRL CR
CC
D. Carter
Cupicha
Eads
M. Fountain Scott Skidmore
Willig
22671
WCK017299