Document XOw8jJXZJer4rJ0ga9ZpgqGJd

9.6/Ge 8ASC 1977 c SGP 0023803 DT Document Index ............ 2 MR Manufacturer Testing Facilities............................. 4 UA Uses, Applications, Limitations ......................... 4 PP Product Presentation......... 5 OP Overall ProductionPlace .. 6-27 Al Construction, Assembly, Installation .......................... 14-27 MF Materials, Finishes ............ 28-34 CS Coatings, Surfaces .......... 28-34 TO Technical Support........................35 CC Code Acceptability, Certification ....................... Georgia-Pacific Distribution Centers Back Cover 35 36 Georgiaffecific ^ 9.6/Ge TESTING AND RESEARCH FACILITIES Georgia-Pacific's Gypsum Product Development and Technical Service laboratory is located at Tigard, Oregon. This is where new products such as Predec gypsum paneling, tile backer board, sound deadening board, Sentinel'" board, Denscote*, Denscal, i and Densite* plasters, and Firestop, Speed Set asbestos free joint com pounds and gypsum ooard had their beginnings. The G-P family of joint system products, the G-P sound control systems and the G-P fire rated systems, including the shaft wall systems, were also developed here. The increase in multi-family living has made fire safety and sound privacy of utmost importance. The technical personnel at the Gypsum Lab also deal with quality and produc tion problems. The effort to offer reliable products at the lowest possible cost is a never-ending tas< Georgia-Pacific must be techmcallv competent in these continually changing times in order to be able to furnish me oroducts required by the construction industry. 3 SGP 0023805 GeorgiaF&cific ^ 9.6/Ge GEORGIA-PACIFIC THE COMPANY Georgia-Pacific began its history distributing lumber domestically and abroad from the South, then en tered the fields of plywood manufacture and timber ownership and management. It believed in inte grated manufacturing and each phase of using a tree's residue produced something new... lumber hardboard, particleboard, pulp, paper (fine papers, working papers, containers, tissues, food board, etc.), chemicals from paper residues, chemicals to help make wood products, chemicals for broad market sales, new kinds of plywood, recycling of wood and chemical materials, development of new and better trees, better timber management methods. Other resources include... gypsum (gypsum products), natural gas, metallurgical and other coal, oil, silica, ceramic clays and many other minerals. G-P is also a nationwide distribution system in every major market in the United States and Canada, and a transportation company with fleets of trucks and railcars to ensure good service with good products. Georgia-Pacific owns timber throughout the U.S. and in Brazil and Canada; timber rights in Indonesia and the Republic of the Philippines. It also manu factures wood products in Brazil, the Philippines and Indonesia, selling to both Asia and America. G-P is a highly decentralized company with over 33,500 employees working in 47 states, the District of Columbia and several foreign countries. Georgia-Pacific ... The Growth Company. 5 SGP 0023807 GYPSUM BOARD NAILS & SCREWS SELECTOR GUIDE > Slftw board to Malal Framing OlMflptfMi AppHcaMawe 1V4- GW0-54 Annular Ring Nail 12V> ga.: with a slight tapar to a small fillet at shank. Bright finish; mao diamond ot. Vt". V and V*" Gyosum board. V*" and V Gypsum Backer Board to wood frame IH* Annular fling Nail (Sam* at GW8-54 except for lengtrt) Vc" Gypsum board to wood frame 2Vi" 7d nail 13 ga . v" diamond head Vi ` Firestop* Gypsum board face layers over '/" Sound Oeadentng Board or 2 layers V Firestop to Wood Studs IV*" 6d Natl 13 ga., V*" diamond head Vi" and y* Gyosum board over existing surface, wood frame IV 6d Nan 13 ga.. V*" diamond head Vi" Ftrestoo Gypsum board to wood frame 1*%' 5d Nail 13M* ga., diamond head 1 v* - Matching Color Head Nad (Steel) 1 v* " Matching Color Head Nail (Steel) Vt" Firestoo Gyosum board to wood frame Predecorated Gypsum board to wood frame over existing surface, wood frame 1 y*" Matching Color Head Nail (Brass) Predecorated Gypsum board (colors i to wood frame 1" Gypsum board Screw Type S Smgie Layer Gypsum board to 25 Gauge Steel Studs. Gyosum board to Resilient Channel. Gypsum board to Metal Furring. 1 v* - Gypsum board Screw Tyoa S 1H" Gypsum board Screw Type S 1" core units to L Runner m 2" Solid and Semi-Solid Partition Systems i V Gypsum board Screw Type S Ooubte-Layer Gypsum board to 25 gauge Steel Studs Double-Layer Gypsum board to Metal Furring, 1','* ' Gypsum board Screw Double-Layer Gypsum board Type S thttnwta Qypaum board to Wood 1" Gypsum board Screw Type S-12 Also available m V*\ 1 V#" and ' lengths For single or muiti-'ayer application of Gypsum board to heavy gauge steel (up to 12 gauge). V/*" Gypsum board Screw Single Layer Gyosum board Type W to Wood Framing. Orpaom board to aypauai Riba iv*-1 Gypsum board Screw Type G iV Gypsum board Screw Type G Gypsum board to Gypsum Ribs in Semi-Solid Partition Systems. Wood Trim to Motal Framing 1 Vi" Gypsum board Screw Type S Trim Head 2'/a ' Gypsum board Screw Type S Trim Head Wood trim over single layer of Gypsum board on 25 gauge Steel Studs. Wood trim over double layer Gypsum board on 25 gauge Steel Studs. Mata! Stoda to Ooor Framoa and Rimnora _ ' V Gypsum board Screw S-12 Pan-Head Metal Door frame to 12 gauge (max ) Steel Studs. Metal Studs to Metal Runners Mata! Trim I Ooor Hlngoa to Motal Framing r '/' Type S-18 Oval Head Also available in V.", 1 Y" & 1^4" lengtns Door hinges to door frame and aluminum components to metal. Horizontal and Vortical Application: TYPE S--Metal studs or furring spaced 24" on center Screws should be soaced 12" on center unless otherwise noted m the detailed assemblies shown m Georgia-Pacific literature. TYPE G--Laminated systems and other gypsum to gypsum applications. TYPE W--Wood studs 16" or 24" on center Screws should be spaced 12" on center unless otherwise noted m tne derailed assemblies shown in G-P literature. Selection ot the proper nail for each application is extremely important, par ticularly for fire-rated construction. The nails recommended comply with per formance standards adopted by the Gypsum Association G-P GYPSUM BOARD OR DENS-COTE VENEER PLASTER SYSTEMS. The following tables are summaries only, based on tests at Underwriters' Lab., National Bureau of Stan dards, Univ. of Calif., Ohio State Univ., Geiger and Hamme, Riverbank Lab. and/or Ohio Research Corp. sponsored by the G-P Gypsum Oivision, Gypsum Association, or others. Fire rating, weight, and sound characteristics are based on a combination of spe cific details as tested and published. Where carpet and pad is used in sound tests, carpet is 44 oz. and pad 40 oz. weights. All systems are ranked by STC number in each category. Fire tests conducted according to ASTM El 19. Sound tests conducted according to ASTM E90. COST COMPARISON INDEX: For wood and gypsum partitions, 100 is for 2x4 studs, 16"o.c., '/a'' Regular Gypsum board each side. For metal stud partitions, 100 is for 2'/a " studs, 24" o.c., 5/a" Firestop each side. Other assemblies are rated against those two. Allow for local differences in labor and material costs. FIRE HAZARD (FLAME SPREAD) CLASSIFICA TION: Official Underwriters' Tests, '/a" and V*" Firestop, 10-15 (Labeled); '/a" and W G-P, 10-15 (Not Labeled). More complete listings and details are available. Tests conducted according to ASTM E84. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. 1. STC under sound characteristics is Sound Transmission Class. 2. Official Underwriters' Tests have proven |omt finishing is not required for the rating m assemches of Firestop under certain conditions 3. Under "Building Code Approvals" (A) refers to International Conference of Building Officials; (B) refers !c Southern Building Code Congress. (C) refers " Building Officials Conference of Amer ca Additional ^ccrovais reauested. Check with iccai building of- c ais for verification of approvals as may De squired 4. Not all code scic; ons belong to Model Code Groups. The-e'cre we advise consultation with iccai building off c.ais if acceptance ol these test results are m doubt Combustible Assemblies--For all 45 minute and 1 hour ratings Vs" structural interior plywood or particleboard underlayment grade, over building paper, over Vi" structural interior plywood with ex terior glue CD grade may be used over the wood joists with ceilings as detailed. Noncombustible Assemblies--Ceilings for a:! 1 hour, 1V2 hour and 2 hour noncombustible floor and ceiling construction assemblies with 2" or 2'/t" con crete floor on metal lath over steel bar joints, unless otherwise specified, may be directly attacnec or suspended. Firestop is listed by Underwriters for U.S.A, and Canada and carries the UL Label for 45 minutes, 1, 2 and 3 hour Fire Resistance in various designs and with a Fire Hazard Classification of Flame spread 15, fuel contributed 15, smoke developed 0. SOUND CHARACTERISTICS--References Geiger and Hamme, Inc.; Riverbank Labs; Kodaras. More complete listings and details are available. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. All sound rated assemblies require caulking top and bottom, and other locations where sound leaks may develop. GYPSUM BOARD "R" FACTORS Va" 33 1" Vi" 45 Vi" Insulating 5/a" .56 87 2 80 (wails) 6 SGP 0023808 TECHNICAL DATA WALLS AND COLUMN CONSTRUCTION Q-R GYPSUM BOARD OR DENS-COTE'VENEER PLASTER SYSTEM GeorgiaFfccific ^ G-P Sjrat Fir* Raaiat Rating Taat Rstar. Sound Trans. STC Test Ratar. Cost Comparison Index Part | Thick-1 nasa i Wsight par Sq. Ft. Construction Wall Surtac* WOOD PARTITIONS (STUDS--2 x 4,16' O.C.) 080 20 min. 082 30 min. EST EST 31 i 32 EST EST 90 4'A" 5.2 Ve" Gypsum board Both Sides 100 4'A" 5.9 Vi" G-P Gypsum board Both Sides 084 45 min. U. 317 32 | EST 110 A Vi" 5.9 Vi" Firestop' Both Sides 086 1 hr. U 305 34 , OR-64-8 115 4 3A " 7.0 5/a" Firestop* Both Sides (U.L. 5) j Basic 1 Hr. Fire Rated Wall 087 1 hr. U. 305 34 : OR-64-8 125 43A" 7.0 W G-P Tile Backer Board (U.L. 5) Both Sides 092 1 Vi hr. EST i 37 CR-64-11 135 51/*" 9.5 Vs" Firestop, 1 Layer, One Side, i 2 Layers Other Side 094 1 hr. i G.A. 38 EST 135 47/a" 8.2 3A'' G-P Gypsum board. 2 Layers, Both Sides 096 1 Va hr. ; j G.A. 39 NBS 140 53/a" 9.9 Vi" G-P Gypsu~ board, 2 Layers, Both Sides 098 2 hrs. T-194 41 OR-64-12 160 57/a'' 12 0 5/a" Firestop. 2 Layers, Both Sides 9.6/Ge Rslarsncas Bldg. Dstail Coda Into App Pag* -- ABC : -- BC -- ABC i 14 ABC -- ---- A-- C-- ABC 14 WOOD PARTITIONS/GYPSUM SOUND DEADENING BOARD (STUDS--2 x 4, 16" O.C.) 100 1 hr. U. 312 ! (U.L. 30) 1 45 ! BW-27-FT 145 A7/*" 1 7.96 Vi" Firestop, 1 Layer Strip Laminated Over 'A" Gypsum Sound Deadening Board, 2 Sides ABC 14 102 1 hr. U. 312 47 BW-28-ST 160 5'A" 8 3 5/a" Firestop, 1 Layer Laminated over 'A" Gypsum Sound Deadening Board. , (U.L. 30) i Both Sides ABC 15 r 104 1 hr. EST Vi" Firestop, 1 Layer over1A " Sound 47 : BW-29-ST 175 67/a " 8.79 Deadening Board. Both Sides Laminated. Staggered Studs -- -- 106 1 hr. U. 312 50 BW-35-ST 175 SVe" 8.7 5/a" Firestop, 1 Layer Strip Laminated over V*" Gypsum Sound Deadening (U.L. 30) Board, 2 Sides. 2" Insulation ABC '5 i105 1 hr. EST Vi" Firestop. 1 Layer over 'A '' Gypsum 52 BW-30-ST 190 67/a" ; 8.92 Sound Deadening Board. 2 Sides, 2" Insulation, Staggered Studs _ See Page 6 for Notes 'Firestop is a registered trademark of Georgia-Pacific Corporation. 7 SGP 0023809 0-P Sy*t * Fir* RmM. Rating T**t* R*t*r. Sound Tran*. STC Coat Fart. Twt Compartaon thickR*f*r. indax naM Weight P*r Sq.Ft Comtnietlon Wall Surtae* WOOD STUDS/RESIUENT CHANNELS 112 1 hr. T-3127 44 OR-64-7 135 5Va" 6.3 Va" Firestop* 1 Layer Nailed 1 Side, 1 Layer on Resilient furring other side 114 1 Vi hr. EST 48 OR-64-15 155 5%" 8.8 5/a" Firestop, 2 Layer 1 Side, 1 Layer on Resilient furring other side R*f*r*nc** Bldg. Detail Cod* into App Pag* ABC 16 -- 16 WOOD STUDS/RESILIENT CHANNELS/INSULATING BLANKETS W Firestop, 1 Layer Nailed 1 Side, 116 1 hr. T-3127 50 OR-64-16 150 5Va" 6.4 1 Layer on Resilient furring other side, plus fiberglass insul non in stud space ABC 16 STAGGERED STUD WALLS 150 I'/i hr. EST 43 EST 175 75/s" 11.0 Vs" G-P Regular, 2 ! /ers, Both Sides -- -- 152 2 hrs. EST 47 TL-69-210 190 8Vs " 12.7 Va" Firestop, 2 layers. Both Sides ABC -- Based on 154 1 hr. U. 305 48 (U.l. 5) EST 140 6 Vs" 7.0 V~ Firestop, 1 layer each side, 2x6 plate, 2" insulation ABC -- DOUBLE WOOD STUDS 108 1 hr. Vs" Firestop, 1 Layer Laminated over EST 50 BW-31-ST 225 10" 9.14 V*" Gypsum Sound Deadening Board, Both Sides, Double Studs 109 1 hr. Vs" Firestop, 1 Layer Laminated over EST 55 BW-32-ST 240 10' 9.29 V" Gypsum Sound Deadening Board, 2 Sides, 2" Insulation, Double Studs 170 1 hr. EST 46 s/a" Firestop, 1 layer ach side double EST 215 9 V." 7.5 row of studs 1" apart on separate 2x4 plates, insulation m stud space Vs" Firestop Gypsum board. 2 layers 175 2 hrs. . WP297 FM 57 RAL -- 11 Vs" -- face each side of wall. 1 layer attached to each stud inside, with 1" space between inside layer- Lot Line Wall ABC -- -- 15 ---- -- 17 WOOD STUDS/FIBER SOUND BOARD 118 1 hr. T-3006 46 OR-64-73 165 5y8" 8.5 Va" Firestop, 1 layer over Vs" Fiber Sound Deadening Board, Both Sides See Page 6 for Notes "Firestop is a registered trademark of Georgia-Pacific Corporation. ABC 17 8 SGP 0023810 Georgia-Pacific ^ 9.6/Ge a* 3rat * Flra Naaist Rattng Taal Rafar. Sound Trans. STC Coal Taat Comparfaon Rafar. Indax Pirt Thick Walghl par $0. Ft. ConalrucHon Wall Surfaca Rafarmctt Bld. I Dataii Coda | info App | Paga EXTERIOR WALLS 500 2 hrs. U302 (U.L. 23) 50 EST -- sw -- Va" Firestop# layers interior; Vi" Gypsum Sheathing, Brick Exterior ABC -- 501 1 hr. U305 (U.L. 5) -- -- 4%" -- plus -- siding Va" Firestop (Interior), Va" Firestop Tile Backer or Va* Firestop Gypsum Sheathing (Exterior) Wood Siding SOLID GYPSUM BOARD PARTITIONS (NON-LOADBEARING) 230 2 hrs. 3.A. 36 G.A. 90 2' Vi" Firestop, 1 Layer Each Side, 8.1 1' Coreboard, height limit 9 ft. based on L/120, 5 lbs. PSF 232 2 hrs. 3.A. 36 G.A. 95 2' 'h" G-P Gypsum board, 1 Layer Each 8.1 Side, 1" Laminated Coreboard, height limit 9 ft. based on L/120, 5 lbs. PSF 234 2 hrs. EST 37 G.A. 100 2'/" 9.1 5/a" Firestop, 1 Layer Each Side, 1" Coreboard ABC ! 17 ABC SHAFT LINERTM SYSTEMS G-P 1 Va" core unit plus two face layer 206 2 hrs. T-4958 -- -- -- 25/a" 10.5 Vi" G-P regular screw-laminated, track and vertical "T splines t S h- 1 1 __ . ..-d 2 hrs. 208 Chase T-4991 Wall -- G-P 1 Vs" core unit, angle runners, 2Vi " 9.0 metal studs, one facing layer of Va" Firestop screwed to studs 210 1 Vi hr. T-4982 -- '-- -- 2V*" A G-P 1 Va" core unit, plus face layer 5/e" 8.4 Firestop screw-laminated. Track and vertical "T" splines on 24" centers METAL STUDS/24" O.C./INSULATING BUCKETS 328 1 hr. T-5316 41 OR-^, 1?_ jh" Vi" Firestop*, 1 layer each side, 2Vi" 4.3 fiberglass insul. in stud space, 2Vi" studs. 300 1 hr. , T-2316 44 OR-64-81. 1l. r/a" 5.0 Va" Firestop, plus 2" fiberglass insul. Jds in stud space. 1 Va" studs Vt" Firestop, 1 layer i side, Vi" 316 1 hr. T-4848 48 OR-66-6 _125 #' 7.0 regular G-P Gypsum board, 2 layers other side (insulation in cavity for STC), 35/a" studs Va" Firestop, 1 layer 1 side, 2 layers 330 1 hr. T-2316 48 OR-64-80 '145' ^a" 7.2 other side, 2" fiberglass insul. in stud space, 1 Va" studs 334 1 hr. EST 48 OR-66-^ 130 4l Vi" Firestop, 1 layer 1 side, 2 layers 6.3 other side plus 2" fiberglass insul. in stud space, 2Vi" studs See Page 6 for Note& '8 ABC; '3 ABC -- SGP 0023811 9 Q*R fot \# Too*'1 Sound Tran*. STC JT.zoor.t - Co*' Port. Comparison Thiele- P#r Index Sd.Fl Construction Wall Surface t METAL. STUDS/24" O.C./INSULATING BLANKETS 310 2 hrs. . T-3218 318 1 Vt hrs. T-3126 324 2 hrs. T-2557 48 BW-12-FT 155 4'/a" Vt " Firestop, 2 layers each side, STC 8.0 based on 2" insul. in stud space, ZVi" studs 50 OR-64-51 150 5Vt" y* Firestop, 1 layer 1 side, 2 layers 8.0 other side plus 3' fiberglass insul. in stud space, 3V' studs 52 OR-64-50 170 6Vt" 11.1 Vt" Firestop, 2 layers both sides plus 2" fiberglass in stud space, 3%" studs Roforoncoo Bldg. OotaN Coda Info Page ABC 20 -- 21 ABC 22 METAL STUDS/24" O.C./C /PSUM SOUND DEADENING BOARD 304 1 hr. U410 (U.L. 32)) -5 BW-16-FT 130 4' Vt" Firestop, 1 layer, laminated over 7.0 V*' S.D. Board, both sides screw attached, 2Va ' studs 306 1 hr. U410 (U.L. 32)) 50 BW-17-FT 140 4' Vi" Firestop, both sides, 1 layer, 7.1 laminated to V*" S.D. Board, screw attached, 2" fiberglass friction fit in stud space. 2 Vt " studs Vt" Firestop, both sides, 1 layer 308 1 hr. U410 (U.L. 32)) 54 BW-18-FT 145 4 Vi" 8.1 laminated to V*" S.D. Board, screw attached, 2" fiberglass friction fit in stud space, 2'/a" studs ABC ABC ABC 19 19 19 METAL STUDS/24" O.C./FIBER SOUND DEADENING BOARDS 320 1 hr. Vi" Firestop, 1 layer 1 side, other EST 44 OR-65-10 125 5%* 5.8 side, 1 layer over Vi" fiber S.D. Board, 3Vt" studs 336 1 hr. EST 49 OR-65-11 135 57/" -- y*" Firestop, 1 layer over Vt" fiber S.D. Board, both sides 3y" studs STEEL STUD CHASE WALL 1%" METAL STUDS 24" O.C.--6" x 12"--GYPSUM BOARD OR METAL TRACK SPACERS) 326 1 hr. EST 47 BW-33ST -- IVt" 6.7 '/a" Firestop, 1 layer laminated over '/" S.D. Board, both sides ABC 22 327 1 hr. T Vt" Firestop, 1 layer laminated over 52 BW-34ST -- IVt" 6.9 V*" S.D. Board both sides, plus 2" insul. ABC -- in stud space -- 1. hr. * UL 5/8" Firestop each side, 3'/a" insulation U 420 52 TL 76-155 -- -- -- in cavity, studs 9'/a" apart. Option of (GA) 25 ga. runners as spacers. ABC -- UL 2 layers Vi" Firestop each side, 3'/a" -- 2 hr. U 420 57 TL 76-156 -- -- -- insulation in cavity, studs 9'/a ' apart. (GA) Option of 25 ga. runners as spacers. ABC UL 2 layers s/a" Firestop each side. Studs -- 2 hr. U 420 52 TL-76-162 -- -- -- 9'/a" apart. Option of 25 ga. runners (GA) as spacers. ABC See Page 6 for Notes SGP 0023812 10 Georgia-fed fic 9.6/Ge O-P Syat Flra Raaiat Rating Taat Rafar. Sound Trans. Coat part. Waight STC Taat comparison ThickRalar. indas na(. P*r Sq. Ft METAL STUD PARTITION 340 35 min. EST OR-65-2 90 3 Vs" 302 1 hr. T-2316 342 1 hr. T-2898 344 t hr. T-2069 346 1 hr. T-2016 312 1 Vs hr. EST 313 1 Vs hr. EST 314 2 hr. T-2557 322 2 hr. T-2557 350 2 hr. T-2406 TL-62-72 95 27/a OR-64-65 130 3%" OR-63-1 100 3W OR-63-11 105 4y8" 6.0 y" Firestop, V layer 3%' v OR-63-2 135 4y*' 7.5 Va" Firestop, other side, OR-64-32 140 5 Vs* 8.0 ya' Firestop, 1 layer 1 side, 2 layers other side, 3Va" studs EST 150 5' 10.4 ya" Firogor 2 layers, 2 sides. 2Vi"smr -zzm OR-64-52 -- 6'/a" 11.0 5/a" Firestop, 2 layers, 2 sides, 3ya" studs EST -- 6VV 10.4 y8" Firestop, 2 layers. 2 sides (face layer--Eternawall), 3y8" studs STEEL COLUMN FIREPROOFING -- 1 hr. -G.A. -- -- -- 1 hr. EST -- -- -- 1 Vs hr. G.A. -- -- 2 hr. ' X520 -- (U.L. 20) -- 2 hr. X517 -- (U.L. 8) -- 3 hr. X513 -- (U.L. 39) -- -- -- -- -- 3 hr. X509 -- (U.L. 18) -- 4 hr. X501 -- (U.L. 26) -- -- See Page 6 for Notes -- -- -- Vs" G-P Gypsum board, 2 layers -- -- -- y8" Firestop, 1 layer -- -- -- Vs" G-P Gypsum board, 3 layers -- -- -- Vs " Firestop, 1 layer -- -- -- y8" Firestop, 2 layers -- -- -- Vs " Firestop, 2 layers -- -- -- y8'' Firestop, 3 layers -- -- -- y8" Firestop, 4 layers tfarancaa Datail Info Pago i w -- 18 -- AfC -- ABC -- -- 20 ---- ABC 20 ABC ; 21 ABC | -- 1 ---- AB -- _ -- ---- ABC -- ---- ABC -- ABC -- 11 SGP 0023813 Q-P 3yt WtlgM Sound noting Fir* Rotiitanco Bldg. Ootall Lb./ ----------------------------------------------------------------------- Cod* Info Sq. FL Rating T*t R*(. Rating T**t Raf.* App. Pag* WOOD JOISTS ir O.C. FINISHED FLOOR ON ROUGH SUBFLOOR, EXCEPT AS NOTED 400 Vs" G-P Regular, 1 layer nailed -- 401 Vt" G-P Regular, 1 layer nailed 11.4 402 Vi" Firestop*, 1 layer applied to metal furring -- channel 16" o.c. with 1" x 6" T. & G. subflooring. 1 layer of resin building paper, and 1" x4" T. &G. finished flooring, or 2 layers plywood -- -- STC47 IIC 39 -- 15 min. -- -- 25 min. -- TL64-155 1 hr. L502 (UL-33)- ABC ABC -- -- ABC 22 403 V2" Firestop, 1 layer nailed. 11.4 -- -- 45 min. U.L. No. 1 AB 404 Vs" Firestop attached to resilient metal fur ring 24" o.c. with Vs " plywood subfloor and carpet and pad 405 Vs" Firestop, 1 layer nailed, 1 layer 1" x6 ' or plywood subfloor, 1 layer 1" x 4" or plywood finish floor 406 Vs" Firestop, 1 layer attached to 2" x8" joists 16" o.c. and 2" x 4" joists 16" o.c. Vi" plywood subfloor attached to 2" x 8" joists 16" o.c. with rug and pad, 3" insulation in cavity -- STC 48/ IIC 68 L-2243 &4 1 hr. EST. ABC 12.0 STC, 38, IIC 34 (EST.) 1 hr. L501 (U.L. No. 1) AB -- STC 51/ KAL-224- 1 hr. IIC 79 14 + 15 -- 407 5/s" Firestop, 1 layer nailed; 2nd layer Vs" Firestop applied to resilient furring channel 24" o.c. between layers 16.0 -- -- 2 hr. L505 ABC (U.L. No. 217) -- 23 -- 23 -- 408 Vs" Firestop. nailed, 1 Vs" lightweight concrete -- STC 53/ Vs" plywood, wood joists, 16" o.c. insulation, IIC 73 resilient furring, carpet and pad L-22427 & 28 1 hr. EST. A-- 409 Vi" Firestop, 1 layer nailed, 1" x 6" T.&G. or 13.0 plywood subfloor, 1" x 4" or plywood finish floor 411 Vs" G-P Regular, 2 layers nailed -- STC 35 IIC 32 G.A. 1 hr. L503 ABC -- (U.L. No. 46) -- 30 min. EST. ---- 413 V2" G-P Regular, 2 layers nailed -- 415 Vi" Firestop, 1 layer;laminated and nailed to '/" G-P Gypsum Sound Deadening Board, with floor of Vs" CD plywood, Vt" particleboard underlayment. carpet and pad 417 Vs" Firestop, 1 Jayer laminated and nailed to V* " G-P Gypsum Sound Deadening Board with floor Vs" CD plywood, '/*" particleboard under layment,'carpet and pad 420 Vi" Firestop, 1 layer screwed to resilient channel 24" o.c., Vs" plywood subfloor with 3/s" particleboard over wood joists 16" o.c., 3" insulation, carpet and pad 422 Vs" Firestop, nailed, 15/s" lightweight concrete, Vs" plywood, wood joists 16" o.c., insulation, carpet and pad -- -- STC 41 / IIC 75 STC 42/ IIC 75 STC 53/ IIC 72 STC 47/ IIC 65 -- BW-2MT 1 hr. 1 hr. (EST.) 1 hr. OC3-MT 1 hr. L-22429 & 30 1 hr. EST. EST. EST. FC 181 (FM) EST. ---- A 22 ABC 23 A_ See page 6 for Notes. 12 SGP 0023814 GeorgiaFfecific 9.6/G0 a# 8rt WjaM S4.FL Sound Rating Rating | TmI R4. F1r Raslttanca Radas | ^Ral.* sa Apr. WOOD JOISTS 24* O.C. 475 Vs" Firestop, tteyeeittached to resilient channel 16* o.c., J,i*" TAG. plywood subfloor, glue-nailed, over 2'xfjm joists 24" o.c. STC 50 EST. 1 hr. U.L. L513 23 2* CONCRETE FLOOR ON METAL LATH OVER STEEL BAR JOISTS 24* O.C.--INCOMBUSTIBLE 421 %" Firestop nailed or screwed to metal furring 16" o.c. 34.2 -- -- 1 hr. U.L. No. 2 ABC -- 427 Vt" Firestop, metal furring 24" o.c. 33.9 * --s T -1 429 Vs" Firestop Tygg XXX,metal furring 24" Q.e<^ 36.4 431 Vs'Breirtop, metal deck 24" o.c. af 37.0 -- -- -- -- 1 Vi hr. G502 ABC -- (U.L. No. 17) -- 2 hr. G505 ABC -- (U.L. No. 259) -- 2 hr. U.L. File ABC -- R4024-12 2Vi" CONCRETE FLOOR WITH STEEL BAR JOISTS 24" O.C.--INCOMBUSTIBLE 440 Vi " FirestBjfcmetal furring 24' o.c. 38.5 -- -- 442 Vs" Firestop, metal furring 24" o.c. 39.3 -- -- 2 hr. G504 ABC -- (U.L. No. 237) 2 hr. U.L. No. 69 ABC -- 2%* CONCRETE FLOOR WITH OPEN WEB STEEL JOISTS 24* O.C.--INCOMBUSTIBLE -- Vi" Firestop, Chicago metallic steel framing 48" o.c. -- 2 hr. STEEL-WOOO COMBINATION JOISTS 450 Vs" Firestop. 18" deep combination steel- -- wood joists 32" o.c., 3" insulation, resilient furring, carpet and pad, 1 '/s" plywood subfloor 452 Vs" Firestop, 18'deep combination steel- -- wood loists 16" o.c., 3" insulation, Va" plywood, lightweight concrete deck, carpet and pad STC 47/ INR + 18 STC 46/ INR + 11 L-224- 1 hr. 35 & 36 L-224- 1 hr. 37 &38 G523 ABC -- EST. ---- EST. ---- BEAM PROTECTION -- Vs" Firestop, 2 layers ---- -- 2 hr. N501.N502 (U.L. No. 254, 255) "Many of these are new numbers assigned by Underwriters' Laooratories. (Old numbers are in parentheses.) See Page 6 for Notes -- -- 13 SGP 0023815 SYSTEM INSTALLATION DETAILS ft- FtREStOP GYPSUM BOARD 1 LAYER BOTH SIDES (BASIC 1 HR. FIRE RATED WALL) #086 STC/34 SOUND TEST OR-64-8 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L U305 (U.L 5) Materials Used 1. 2' x 4' Wood Studs 16" o.c. 2. 2' x 4" Wood Plates 3. V" Firestop* Gypsum board ft" FIRESTOP* GYPSUM BOARD 2 LAYER 2 SIDES #098 STC/41 SOUND TEST OR-64-12 FIRE RATING/2 HR. COMBUSTIBLE FIRE TEST T-194 Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. 5/s" Firestop* Gypsum board 4. 6d and 8d Nails. 7" o.c. ft" FIRESTOP GYPSUM BOARD LAMINATED TO ft" GYPSUM SOUND DEADENING BOARD #100 STC/45 SOUND TEST G&H BW 27FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L U312 (U.L 30) Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. V* " Gypsum Sound Deadening Board 4. Vi" Firestop Gypsum board or Firestop* Eternawallr" 5. 5d cc Nails. 7" o.c. 14 SGP 0023816 %- FIRESTOP' GYPSUM BOARD LAMINATED TO V*" GYPSUM SOUND DEADENING BOARD #102 STC/47 SOUND TEST G&H BW 28FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L U312 (U.L 30) Materials Used 1. 2" x 4" Wood Studs 16" o.c. 2. 2' x 4" Wood Plates 3. V* ' Gypsum Sound Deadening Board 4. V" Firestop- Gypsum board or Firestop-* ternawall" 5. Joint Compound 8. 4d Finishing Nails Georgia-ffecific ^ %" FIRESTOP* GYPSUM BOARD TYPE X, 1 LAYER LAMINATED TO '/a" S.D.B., 2 SIDES WITH Itt" INSULATION #106 STC/50 SOUND TEST G&H BW 35FT FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L U312 (U.L 30) Materials Ueed 1. 2" x 4* Wood Studs 16' o.c. 2. 2" x 4' Wood Plates 3. 'A ' Gypsum Sound Deadening Board 4. 5/e" Firestop* Gypsum board or Firestop* Eternawall,M Gypsum board 5. Joint Compound 6. 4d Finishing Nails 9.6/Go W FIRESTOP' GYPSUM BOARD LAMINATED TO Va" GYPSUM SOUND DEADENING BOARD #105 STC/47 STC/52 WITH INSULATION SOUND TEST G&H BW 29ST/G&H BW 30ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2'' x 4" Wood Studs staggered 8" o.c. on opposite sides of 2" x6" Wood Plate 2. 2" x 6" Wood Plata ' 3. V< " G-P Gypsum Sound Oeadening Board 4. Vi " Firestop* or Firestop* EternawaH" Gypsum board 5. G-P Joint Compound 6. 4d Finishing Nails and 4d Common Nails .7. 5d Common Nails. 7" o c. 8 2" Insulation Batts (on BW-30ST for STC/52) W FIRESTOP* GYPSUM BOARD LAMINATED TO Va" GYPSUM SOUND DEADENING BOARD #109 STC/50 STC/55 WITH INSULATION SOUND TEST G&H BW 31ST/G&H BW 32ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2" x4" Wood Studs (double row) 16" o.c. 2. 2" x 4" Wood Plates--1' apart X V" G-P Gypsum Sound Deadening Board 4. Vi " Firestop* or Firestop* Eternawall:u Gypsum board X 4d Finishing Nails, 4d Nails 6. 5d Nails. 7" o.c. 7. G-P Joint Compound X 2" Insulation Batts (on BW 32ST with insulation for STC/55) SGP 0023817 15 %" FIRESTOP* GYPSUM BOARD ON RESILIENT CHANNEL #112 STC/44 SOUND TEST OR-64-7 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3127 Material* Uaad 1. 2" x 4" Wood Studs 16" o.c. 2. 2 " x 4" Wood Plates X Va" Firestop* Gypsum board 4. Resilient Channels 5. 1 V* " Type W Gypsum board Screws ft " FIRESTOP* GYPSUM BOARD 2 LAYERS 1 SIDE/1 LAYER ON RESILIENT CHANNEL OTHER SIDE #114 STC/48 SOUND TEST OR-64-15 FIRE RATING/1 Vi HR. COMBUSTIBLE/EST. Materials Uaad 1. 2" x 4" Wood Studs 16''o.c. 2. 2" x 4" vyjjod Plates 3. Va" Firestop* Gypsum board 4. Resilient Channels 5. 1 V. " Type W Gypsum board Screws . 1" Type S Gypsum board Screws V8-Ftfi6STOF 2i* *000 STUOS 0f6uShIpLiInEgNTCMhaEnTAnLels i if gypsum filler strip 2i4 WOOO PLATES PLOOR anO ceiling fj %" FIREST " GYPSUM BOARD ON RESILIENT CHANNEL WITH INSULATION IN CAVITY #116 STC/50 SOUND TEST OP-64-16 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3127 Materials Uaad 1. 2" x 4" Wood Studs 16" o c 2. 2" x 4" Wood Plates 3. Firestop* Gypsum board 4. 2" Insulation 5. Resilient Channels 6. 1'/" Type W Gypsum board Screws 7. 1" Type S Gypsum ooard Screws e fiocgTOP----------- ---- \ 2 C'LlEP V'P 2*4 WOOO PLACES 16 SGP 0023818 %" FIRESTOP* GYPSUM BOARD OVER FIBER SOUND DEADENING BOARD 2 SIDES #118 STC/48 SOUND TEST OR-64-73 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST T-3006 Materials Used 1. 2" x4" Wood Studs 16" o.c. 2. 2" x 4" Wood Plates 3. 2" x 4' Wood Fire Blocks 4. '/a" Fiber Sound Deadenng Board 5. y" Firestop Gypsum board $. Sd Cement Coated Nails and 8d Box Nails 7. Laminating or Joint Compound GeorgiaFfecific FIRESTOP GYPSUM BOARD 1 LAYER EACH SIDE OVER T. & G. COREBOARD #230 STC/36 SOUND TEST G.A. FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST G.A. Materials Used 1. 1" T. & G. Coreboard, "V" edge 2. Vt" Firestop Gypsum board 3. Metal Track 4. Laminating Adhesive 9.6/Ge ft" FIRESTOP* GYPSUM BOARD 2 LAYERS ON FACE, 1 LAYER INSIDE, BOTH SIDES #175 STC/57 STC/59 WITH INSULATION SOUND TEST R.A.L ... FIRE RATING/2 HR COMBUSTIBLE FIRE TEST FM WP-197 Materials Used 1. 2" x 4' Wood Stud^24' o.c. 2. Fi reblocks--2" x 22 v * 3. '/a" Firestop Gypsum board 4. 8d Coated ^ox Nails 5. 6d Coated Box Nails S. 6d Nails 7. 12d Common Nails V2" GYPSUM BOARD OVER COREBOARD #200 STC/47 SOUND TEST OR-64-39 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2575 Materials Used 1. 3" x iy" Wood Perimeter Framing 2. 1" x 24" Tongue & Groove Co reboard 3. '/a " Gypsum board 4. Laminating Compound 5. Sd Nails 17 SGP 0023819 %" FIRESTOP* GYPSUM BOARD 1 LAYER EACH SIDE #300 STC/35 SOUND TEST OR-64-81 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-2316 Material* UMd 1. 1 V%" Steel Studs, 24" o.c. 2. 1 Vi" Floor and Ceiling Track 3. V" Firestop* Gypsum board 4. 1" Type S Gypsum board Screws Vi" FIRESTOP GYPSUM BOARD 1 LAYER EACH SIDE WITH INSULATION IN CAVITY #328 STC/41 SOUND TEST OR-66-5 FIRE RATING/1 HR. MON-COMBUSTIBLE Materials Used 1. 2Vi" Metal Stud 24" o.c. 2. 2 Vi" Metal Jrack Top and Bottom 3. Vi " Firestop Gypsum board 4. 2Vi" Insulation 5. 1" Gypsum board Screws %" FIRESTO GYPSUM BOARD 1 LAYER EACH SIDE WITH INSULATION IN CAVITY #302 STC/44 SOUND TEST OR-64-81 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-2316 Materials Used 1. 1 Vi" Steel Studs, 24" o c. 2. 1 V" Floor and Ceiling Track 3. Vt" Firestop* Gypsum coard 4. 1 Va'' Insulation 18 SGP 0023820 %" FIRESTOP' GYPSUM BOARD 1 LAYER OVER V*" GYPSUM SOUND DEADENING BOARD EACH SIDE #304 STC/45 SOUND TEST BW16FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-3854 A U410 (U.L 32) Malarial* Used 1. 2y*' Steel Studs, 24' o.c. 2. 2'/a ' G-P Steel Track 3. V* " Gypsum Sound Deadening Board 4. 1" Type S Gypsum board Screws 5. '/a " Firestop Gypsum board or Firestop Eternawall:" Gypsum board GeorgiaFfccific ^ %" FIRESTOP' GYPSUM BOARD OVER y" GYPSUM SOUND DEADENING BOARD WITH INSULATION IN CAVITY #306 STC/50 SOUND TEST BW 17FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST UL U410 Materials Uaad 1. 2'/a * G-P Steel Studs, 24" o.c. 2. 2'/a' G-P Steel Track X 2' Insulation 4. Vi " G-P Gypsum Sound Deadening Board 5. 1" G-P Type S Gypsum board Screws 6. Va" Firestop Gypsum board or Firestop EternawallIU Gypsum board 9.6/Ge FiPESTCP GYPSUM BOARD OVER Va" GYPSUM SOUND DEADENING BOARD WITH INSULATION IN CAVITY #308 STC/54 SOUND TEST BW 18FT FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST UL U410 Malarial* Used 1. 2Va" G-P Steel Studs, 24" o c. 2. 2>/a " G-P Steel Track 3. 2" Insulation 4. Vi " G-P Gypsum Sound Deadening Board 5. 1" G-P Type S Gypsum board Screws 6. V" Firestop Gypsum board or Firestop Eternawall'" Gypsum board 19 SGP 0023821 Vi " FIRESTOP* GYPSUM BOARD, LAYERS 2 SIDES WITH INSULATION IN CAVITY #310 STC/48 SOUND TEST BW 12FT FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-3218 (fiberglass insulation not required for fire rating) Material* Uaad 1. 2'/a" G-P Steel Studs. 24" o c. 2. 2'/a" Floor and Ceiling Tracks 3. Vi " Firestop* Gypsum board 4. 2" Insulation 5. Laminating or Joint Compound 6. 1" and IVa" Type S %" FIRESTOP' GYPSUM BOARD, 2 LAYERS 2 SIDES #314 STC/46 EST. FIRE RATING/2 HR. NON-COMBUSTIBLE/EST. FIRE TEST T-2S57 Material* Uaad 1. 2Va" G-P Steel Studs. 24" o.c. 2. 2Va " Floor and Ceiling Track 3. 5/s" Firestop* Gypsum board, 2 layers each side 4. 1" & 1 5/a" Type S Screws %" FIRESTOPw GYPSUM BOARD, 1 LAYER 1 SIDE, 2 LAYERS OTHER SIDE #312 STC/43 SOUND TEST OR-63-2 FIRE RATING/1 sh HR. NON-COMBUSTIBLE/ EST. Material* U*ad 1. 2'/a" G-f? Steel Studs, 24" o.c. 2. 2'/a "/foor and Ceiling Track 3. sV>Firestop* Gypsum board 4..-1" and 1 V" Type S Gypsum board Screws FIRES OP' GYPSUM BOARD, 1 LAYER 1 SIDE, W G-P REGULAR, 2 LAYERS OTHER SIDE #316 STC/48 EST. FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST T-4848 Malarial* Ucad 1. 35/" Steel Studs. 24" o c. 2. 35/s"Track 3. '/a" Firestop*' Gypsum board 4. Va " Regular Gypsum board. 2 layers 5. 1 '/a " Insulation (not required for fire rating) 6. 1" and 1 Vs" Type S Screws 20 SGP 0023822 %" FIRESTOP* GYPSUM BOARD, 2 LAYERS 1 SIDt HBLYER WITH INSULATION #318 STC/50 SOUND TEST OR-^B1 FIRE RATING/1 Yt HR. NON-COMBUSTIBLfe FIRE TEST T-3126 ^ Material* Uaad 1. 3!/a" Steel Studs, 24"d.c. 2. 3Va" Floor and Ceiling Track 3. ya" Firestop Gypsum board - 4. 3" Insulation -- JB cr 5. Laminating Compound 6. 1" and 17/a" Type SSiyjgttm bqyd ! Georgiaffccific ,c*z. 9.6/Ge 3'. StEEl i'-'-OS s a eioestob 3 ^BEBGLASS 'NSuLAr'ON 3'* cL00RTt>ACK Yt" FIRESTOP GYPSUM BOARD, 1 LAYER 1 SIDE, 1 LAYER OVER Vi" FIBER S.D. BOARD OTHER SIDE -320 STC/44 SOUND TEST OR-65-10 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST EST. Materials Uaad 1. 3Va" Steel Studs, 24_"-b c. 2. 3Va 'Floor and Celling Track 3. Vi" Fiber Sound Deadening Board 4. Laminating Compound 5. ya'' Firestop* Gypsum board 6. 1" and 1 Va" Type S Gypsum board Screws 5, 8" FiBESTOP 31. ' STEEL STUDS 2 SOUND DEADENING BOARD FLOOR TRACK Yt" FiRESTZP GYPSUM BOARD, 2 LAYERS 2 SIDES #322 STC/47 SOUND TEST OR-64-52 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Material* Uaad 1. 3ya" Steel Studs, 24" ox. 2. 3ya ' Floor and Ceiling Track 3. Laminating Compound 4. s/a" Firestop* Gypsum board 5. 1" and 1 Va" Type S Gypsum beard Screws 21 SGP 0023823 H" FIRESTOP* GYPSUM BOARD, 2 LAYERS 2 SIDES WITH INSULATION IN CAVITY #324 STC/52 SOUNO TEST OR-64-50 FIRE RATING/2 HR. NON-COMBUSTIBLE FIRE TEST T-2557 Materials U**d 1. 3V'' Steel Studs, 24" o.c. 2. 3Vt" Ftoor and Ceiling Track 3. !/a" Firestop* Gypsum board 4. 2" Insulation 5. Laminating or Joint Compound 8. 1" and 1 y" Type S Gypsum board Screws %" FIRESTOP* GYPSUM BOARD, OVER V*" GYPSUM SOUND DEADENING BOARD #415 STC/41; IIC 75 (WITH CARPET & PAD) SQUNfr TEST G&H BW 2-MT FIRE RATING/1 HR. NON-COMBUSTIBLE EST. BASED ON L 503 (U.L. 46) Material* Used 1. 2" x 10" Wood Joists 2. Carpet and-Mi W FIRESTOP* GYPSUM BOARD, OVER V4" GYPSUM SOUND DEADENING BOARD #326 STC/47 STC/52 WITH INSULATION* SOUNO TESTS: BW-33ST/BW 34ST FIRE RATING/1 HR. NON-COMBUSTIBLE Materials U**tf 1. 1 y" Steel Studs, 24" o.c w .jgyjaBfrfW* Floorand air-Pty" G-P V*" Gypsum restop* .lEMnawaliTM G^SBire board JL 1 %" Type S Gypsum board Screw*1 * 1 '4 " Type S Gyptdai board . 7. \hx Sx 12' Gypafeh board S.:Mfihsulation Batts (on BW>$ 1/4- GYPSUM SOUNO OCAOENINO BOARD APPLIED VERTICALLY 1 / 7* FIRESTOP APPLIED VERTICALLY W FIRESTOP* GYPSUM BOARD ON RESILIENT METAL FURRING (FLOOR/CEILING) #402 STC/47 SOUND TEST TL 65-155 FIRE RATING/1 HR. NON-COMBUSTIBLE FIRE TEST L502 (U.L. 33) Material* Used 1. 2" x 10" Wood Joists 2. Rosin Building Paper 3. 1" x 6" Tongue and Groove Subfloonng 4. 1" x4" Tongue and Groove Finished Flooring 5. Donn DG-8 Resilient Channels 6. Vi" Firestop' Gypsum board 7. 1" Type S Gypsum board Screws and 8d Nails ft" FIRESTOP* GYPSUM BOARD ON RESILIENT METAL FURRING (FLOOR/CEILING) #404 STC/48 SOUND TEST L-224-4 FIRE RATING/1 HR. COMBUSTIBLE/EST. Material* U*ed 1. 2" x 8" Wood Joists--16' o.c. 2. Vt" Plywood 3. 44 oz. Wool Carpet 4. 40 oz. All Hair Pad .5. 3' Insulation 6 Resilient Channels 7. Vs" Firestop* Gypsum board 8. 8d Nails 9. 1" and 1 V " Gypsum board Screws Georgia-fecific ^ ft" FIRESTOP* GYPSUM BOARD ON RESILIENT METAL CHANNEL 24" O.C. #420 STC/53; IIC 72 FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST FC 181 (FM) Material* Used 1. 2" x 10" Wood Joists 7. Resilient Channel 2. Vs" Plywood Subfloonng 8. 8d Nails XV*' Particleboard 9. 1" Gypsum board Screws 4. VA" Nails 10. 3 Vi" Insulation 5. 8d Nails .8 '/:" Fi restop* Gypsum board 11. Carpet and Pad 9.6/Ge ft" FIRESTOP GYPSUM BOARD INSULATION WITH CEILING INDEPENDENT OF FLOOR #406 STC/51; INR + 29 SOUND TESTS: KAL-224-14, KAL-224-15 FIRE RATING/1 HR. COMBUSTIBLE/EST. Material* Uaed 1. 2" x 8" Wood Joists 2. Vt" Plywood X 44 oz. Wool Carpet / 4. 40 oz. All Hair Pad 5. 8d Nails X 2" x 4" Joists 7. 3" Insulation' 8. Vs" Ficestop* Gypsum board ft" FIRESTOP' GYPSUM BOARD ON RESILIENT METAL CHANNEL #475 STC/50/EST.; IIC/70/EST. (WITH CARPET & PAD) FIRE RATING/1 HR. COMBUSTIBLE FIRE TEST U.L. L513 1. T. & G. Plywood X Adhesive X Vs" Gypsum board Strips 4. ,2" x 10" Wood Joists X Resilient Furring Channels 6. Firestop* Gypsum board 5/a" FIRESTOP GYPSUM BOARD STRIPS stapled to plywood at joints--------vv tig plywooo AOHEI JOISTS 2A" O C (ZxlO'S MIN ) (NO BRIDGING REQUIRED) RESILIENT FURRING CHANNELS SPACED 16* 5/r FIRESTOP GYPSUM0OARO CEILING 23 SGP 0023825 WFIRESTOP* GYPSUM BOARD-- 2 HR. RATING--NONCOMBUSTIBLE, FLOOR/CEILING INSTALLATION DETAILS 2* Santf-Grtvtl Concratc Steel Lath U.L. Design G505 (UL259)--2 Hr. (with 2" concrete) Construction with G-P Firestop* board saves money! G-P 5/a" Firestop gypsum board per units use of 2" concrete floor whereas other systems require 2 Vi" concrete floor for a 2 hour fire rating. The reduction in weight makes possible consider able savings in material and labor. Concrete Floor Metal Lath Sleel Bar INSTALLATION DETAILS APPLICATION OF RIGID PREDECORATED PANELS TO GYPSUM SUBSTRATE Use a" or Vi" gypsum board. Attach to studs with 1 Vs" gypsum board nails, 1" gypsum board screws (metal studs) or drywall stud adhesive. Joints need not be taped or sealed. Install the gypsum board vertically with the edges centered on the framing members. The rigid predecorated panels should be applied using a bead of panel adhesive over each stud. Se cure paneling at top and bottom plates with 4d finishing nails 12" o.c. Field fasteners not required unless panels are bowed. The addition of gypsum board as a substrate when using predecorated panels provides increased FIRE RESISTANCE and SOUND CONTROL. TEST RESULTS Paneling Panaling with H" (No Gyp*urn) Gypsum Pinvling with W Gypmim Burn thru Time 8 min. 42 mm. 73 min. (plusl Better Sound Rating 28 STC 40 STC 40 STC Better Impact Resistance 26 82 82 Metal Furring Channel GYPSUMBOAflO FURRING STRtP UL Design G505 attachment details 24 SGP 0023826 APPLICATION OVER MASONRY WALLS On masonry walls either above or betow grade, be sure the wall is properly waterproofed before furring is applied. Although moisture barrier gypsum board are available--there is obviously no substitute for proper waterproofing. Wood Stripe or Metal Channels: Apply furring horizontally or vertically. Space 16" o.c. for '/" and 3/a" gypsum board, and 24" o.c. for Vi" and y" gypsum board. Use concrete stub nails or power driven fasteners to install furring. Gypsum board should be applied perpendicular to furring. Use G-P insulating Gypsum boarc Georgia-Fbcific ^ TUB 9.6/Ge WATER RESISTANT GYPSUM BOARD G-P Tile Backer Board is a water resistant gypsum product with a light blue^face paper, designed for use as a base for the adhesive application of ce ramic, metal or plastic t e. The gypsum core consists of noncombustible gyps jm rock, combined with an emulsion giving high water resistance. This product is especially designed for bathrooms, powder rooms, utility rooms^nd kitchens. Caution: G-P Tile Backer Board is not'designed for exterior areas or other areas where there may be sustained moisture or humidity, ' For fire rated partitions between bathrooms or in terior areas sublet to moisture use y*' Firestop* Tile Backer proven by Underwriters' Laboratories in a 1 -hour assembly over wood studs. The raw edges of Tile Backer Board (end joints, cut edges, cut-outs) are to be caulked with a coating of the waterproof compound used in applying the tile. As an alternate to caulking, G-P can provide a spe cial 2Vi" wide self-adhering vinyl tape to place over edges and cut-outs. For fire and sound rated construction the Tile Backer Board must extend to the floor. 25 SGP 0023827 COLUMN FIREPROOFING Fireproofing with Firestop* Gypsum board provides a fast, efficient and economical method of protect ing steel columns. Fire resistant assemblies of two. three and four hours are obtainable depending upon the number of layers of */*" or Vi" Firestop Gypsum board used. These layers are held in place by a combination of screws and metal studs. The two, three and four hour fire rated assemblies of Firestop Gypsum board have passed Official Fire Tests conducted by the Underwriters' Laboratories. Fir* Reeietenc*--For three hour protection, two layers of Vi" Firestop Type XXX can be used. Test No. X513 (UL 39-3 hour). Two hour protection can be obtained using 1 layer of Vi" Firestop Type XXX Gypsum board. Test No. X520 (UL 2C-2 hour). These are for heavyweight columns (14 W.F. 228). For lightweight columns (10 W.F. 49) use 4 layers of y" G-P Firestop Type X for 4 hour protection, 3 layers for 3 hours. Test No. X509 (UL 18) and 2 layers for 2 hour, Test No. 517 (UL 8 . Lighter--As compared to other types of fireproof ing, a dead load savings of from 50 to 75% can be realized with G-P Firestop Column cireproofing. Sp**d of Erection--Firestop Gypsum board can be installed quickly and easily when used for column fireproofing following G-P details. Minimum amount of the wire and adhesives are used. 2" SOLID LAMINATED-- (NON-LOAD BEARING) A 1" gypsum coreboard with Va " gypsum board laminated to each side; no air space. A 2* solid wall system has a 2 hour fire rating, an STC rating of 35, produces smooth monolithic walls and creates extra usable floor space. 2" SOLID LAMINATED FLOOR AND CEILING DETAILS l\S'Ctlh*n| rial taping to caifmi f'borglMI " pc ether rn><CCoanuclkrientge mil non cOtebvttiNo 1 or power shot rmeasiioliennatt {! fastener concrete ceiling CONCRETE CEILING --fir1 A (Option*!) -1l;if-n 1. '. i :Lrii [ K Caulking -- WOOO FLOOR DETAIL Vinyl trim -- (Optional) yL Caulking " CONCRETE FLOOR DETAIL THREE-HOUR fire rated steel column assembly with V" Firestop. X509 (UL 18). Minimum size of column W10X49. TWO HOUR fire rated steel column assembly with y*" Firestop. X517 (UL 8). Minimum size of column W10X49. 26 SGP 0023828 1 GeorgiaFfecific A 9.6/Ge WOOD AND STEEL STUD APPLICATION There are many different kinds otconstruction sys tems and all are based on the requirements of your particular building installation. Basically, the main considerations are usually: Fire Resistance, Sound Transmission, Relative Strength of the installa tion, Dimensional Restrictions and Economy. After the wall and floor/ceiling constructions have been selected, it is important that they be installed properly. The following precautions should be taken during installation to avoid situations or conditions which will detract from the sound control properties of the assembly. Avoid connecting plenum chambers, ducts, vents, etc. These permit the unrestricted flow of sound. Corrective measures are to make partitions full height, and use ducts lined with absorbent material. Matariala: All gypsum board shall be G-P Gypsum board Vs", '/*" or thick Regular or Firestop*. 4' wide x ceiling height for vertical application or up to 16' long for horizontal application, tapereu edge. All joint treatment products are to be G-P materials. Framing: Prior to the gypsum board application, all framing members should be true and firmly fastened in a plane surface. Provide double studs at all cor ners. Both inside and outside intersections are formed by extending one edge of a panel over the other edge in a flush position and covering with tape and joint treatment. In single ply installation, all ends and joints of gypsum board shall occur over framing members, except that this is not required for treated |Oints at right angles to framing members. Application: Gypsum board may be applied hori zontally or vertically to framing with nails or screws. (Alternate method-stud adhesive may be applied to studs before applying gypsum board.) The gypsum board shall be attached with nails meeting ASTMC514 or with 1V*" long G-P Type "W" gypsum board screws or 1' long G-P Type "S" gypsum board screws, for wood and metal or framing, respectively. SINGLE PLY GYPSUM BOARD MAXIMUM FRAMING SPACING* Thickness Maximum Spacing Application Vs" on wails Vj" on walls Vs" on walls Vs" on ceilings ' a " on cemngs* '/a" on ceilings* Vs" on ceilings 16" 0 C. 24" 0 C 24" o.c Not --ecommenoed 16" 0 C. 24" 0 c 16" or 24" o c. Horizontal or Vertical Horizontal or Vertical Horizontal or Vertical Not recommended Parallel* or Perpendicular Peroendicuiar* only Parallel or Perpendicular FOR WATER BASE TEXTURE APPLICATION Thlcknaaa Vi "on ceiling Vs" on ceiling Max. Spacing 16" o.c. 24" o.c. Application Perpendicularonly Perpendicularonly NAILING OR SCREW SPACING FOR SINGLE-PLY GYPSUM BOARD Gypeum board Thicfcnesa Single Nailing Doubla Nailing Vs" sidewalls................8" o.c. Max.................12" o.c. Max. Va " sidewalls................ 8" o.c. Max.................12" o.c. Max. Va" ceilings................. 7" o.c. Max.................12" o.c. Max. Vs" sidewalls................8" o.c. Max.................12" o.c. Max. ceilings..................7" o.c. Max.................12" o.c. Max. Gypaum board Thickness Framing 16" o.c. Framing 24" o.c. Screw Spacing Screw Spacing Va" sidewalls............ 16" o.c. Max................ -- '/a" sidewalls..............16" o.c. Max................ 12" o.c. Max. Vs" sidewalls..............16" o.c. Max................ 12" o.c. Max. Vz " 4 Vs" ceilings... 12" o.c. Max................ 12" o.c. Max. NOTE: Nails or screws should be driven not less than Vs" from edges or ends of panels and maximum of about 1" except for floating angles While fasteners are being driven, the gypsum board shall be held in firm cbntact with the underlying supports. Preferably, application of fasteners should proceed from the central portion of the gypsum board to the ends and edge. Dimple nails or screws with out breaking the face paper. Joints: All joints should be taped and finished with tape and joint compound, nail or screw heads should be finished with joint compound. Exterior angles are covered with G-P Metal Casing Beads and finished with joint compound. 27 SGP 0023829 GYPSUM BOARD PRODUCTS Georgia-Pacific Gypsum Division manufactures a full range of products to meet the needs of the con struction industry. The versatile gypsum product provides builders with lightweight construction materials that are workable, fire and noise resistant and time saving. G-P research facilities have re sponded to the industry's requests and have de veloped the following multi-use, highly reliable, low cost products. G-P GYPSUM BOARD EDGES T--Tapered S--Square RE--Tapered with Round Edge B--Beveled (Special Order) T & G--Tongue and Groove MB--Modified Beveled Edge See page 31 for detailed description G-P REGULAR GYPSUM BOARD G-P Regular Gypsum board is faced with a strong, cream colored paper which will accommodate almost any type of decorative treatment. The back paper, which is gray, is as strong as the face paper. The Va" and Vs" tapered and round edge gypsum board are recommended for single layer application in new construction. They are designed to be rein forced with G-P Joint System products resulting in a smooth, seamless surface. Square edges are recommended for use where joints will be exposed. The resistance to fire exposure and sound transmission increase with thickness and the number of layers of board used. Bevel edges can be used where a panel effect is desired. ^_ Thicknan Widths Langths Edga Va" Va" Va" &--____ A 6' to 16' in even feet T, S, B, RE FIRESTCP* GYPSUM BOARD Firestop Gypsum board develops 45 minute to 3 hour fire resistant ratings in various wood and steel wall, floor/ceiling assemblies and column and beam protection. Teazle glass filaments and other ingre dients keep the core intact, even after the cMMically combined water has been released. Thicknasa Va" Va" Widths 4' Langths 6' to 16' in even feet Edge T, S, B, RE G-P V4" GYPSUM SOUND DEADENING BOARD G-P '/" Noncombustible Gypsum Sound Deadening Board, when used in the system specified, meets the requirements of the most sophisticated sound control systems available. It is also one of the easiest sound control materials to install. When combined with other gypsum board, it reduces sound transmission, has high structural strength, is noncombustible. It has a distinctive green face paper. When applied over2Va" steel studs or 2 x 4 wood studs, one layer of Va " Firestop Gypsum board over one layer of '/" Gypsum Sound Dead ening Board produces a 1-hour fire resistive wall and a 45 S.T.C. Thickness Widths Langths Edge 1 Va" 4' 8' S1 -- G-P REGULAR TILE BACKER BOARD This is a water-resistant gypsum product with a light blue face paper, designed for use as a base for the adhesive application of ceramic, metal or plastic tile. The gypsum core consists of non-combustible gypsum rock, combined with an asphalt wax emulsion giving high water resistance. Ideal for bathrooms, kitchens, powder rooms and other moisture areas. (See caution: page 25) G-P Tile Backer Board can be erected as easily as regular gypsum board and requires no finishing of joints or nail heads under tile with joint treatment nor further waterproofing under tile applied with adhesive urress required by local code. Thicknan Width* Length* ~ 14" i 4' 8'tQ 12' FIRESTCP TILE BACKER BOARD Same as Regular Tile Backer Board plus the addi tion of glass fiber reinforcement gives increased fire protection and strength. Where fire rated assemblies are required in areas subiect to moisture, such as partitions between bathrooms and other interior areas, most building codes allow the use of Firestop Tile Backer Board. The use of Vs" Firestop Tile Backer Board will give the same fire resistant rating as other Firestop board. Only in design 5-- 1 hr. rating. 11 1 Thlckna** Widths Length* Edge Va" 4' 8' to 12' 1 T G-P REGULAR INSULATING GYPSUM BOARD Regular Insulating Gypsum board with bright aluminum foil laminated to the back surface. The foil paper provides a continuous vapor barrier on the warm side of the wall. To have reflective insulation value, the foil must face a minimum air space of *'. The aluminum foil, facing a 3/" minimum space, reflects 90% of radiant heat, providing insulation qualities equal to Va" of fibreboard insulation (tested by U S Bureau 28 SGP 0023830 of Standards). Panels must be installed with foil side against the studs. Thickn*** W %* Width* 4' Length* 6' to 16' Edg* T, S, RE FIRESTOP* INSULATING GYPSUM BOARD This is the regular insulating gypsum board with the addition to the core of glass fiber for increased fire protection. Through the proper use of this produot desired fire-rated assemblies can be achieved. Thickn*** -------------------------- ,------------------------ Width* Langth* [ Edg* 4' 6'to 16' j T, S, RE G-P REGULAR ETERNAWALL VINYL SURFACED GYPSUM BOARD Standard Una Colors--Fawn. Gold. Buff. Stucco, Tan, Leaf, Yellow Wisp, Snow Drift White, Cherry Design, Walnut Design, Flax Design, Alabaster, Field Grass, Autumn Thatch, Golden Reed and Espana. This panel has the vinyl surface factory laminated to Regular Gypsum board. Available in a variety of colors and textures, it provides beauty and utility to commercial, institutional and home interiors. Etemawall is strong and resilient. The solid gypsum core is non-combustible. Eternawall color won't fade. The deep linaft-lextgred vinyhBKface can be scrubbed " without'dkmage to color, ttftture or desion. Because of its abiithrta take hard wear and to i Etemawap-Wpsum lyinrri (fl ideal for i hotels, crabs, tnd hospitals as welhas lhioarm^Mfc it is alautideally suited fqojiovablelpartition^ jult qg------------------- wMh* 1 Length* <% Speatal oredg ^ [Other rv PL lengths gailabtfc. on special , BE - sggp- 1 order.) I_________________ FIRESTOP ETERNAWALL VINYL SURFACED GYPSUM BOARD This panel has the vinyl surface factory laminated to a Firestop panel which has glass fibers adcfdd to the core to give it additional fire resistance. With this technically designed gypsum core, a 1 hour or greater fire rating may be obtained on wall assem blies. Same colors available as with regular Eternawall Gypsum board. Georgia-Pacific 9.6/Ge Thickn*** Vi" H" Width* 4' 1 ; Langth* 8' (Other lengths available on special order.) Edg* MB | | GYPSUM SHEATHING Traatad--G-P Gypsum sheathing consists of non combustible gypsum rock combined with an asphalt emulsion to provide high resistance to water. All G-p Gypsum sheathing is manufactured to meet A.S.T.M C79, including requirement for water resistance. This eliminates the need for building paper (except where required by local building code). An untreated (non-water resistant) gypsum sheathing is available. The 2' wide sheathing, applied horizontally, is made with precision formed tongue and groove edges and square edges. There are two types of sheathing, %" FIrestop sheathing, which, com bined with 5/s" Firestop wallboard on the interior wall side, meets a 1 hour fire resistance rating, and Vi" Regular sheathing, used where no fire resistance rating is required. Thickn*** ---------------- 1 Width* Langtht Edg* Vj" Reg., % " Firestop* Vi" Reg., %" Firestop* 2' 4' 8' 8' & 9' T&G S GYPSUM FiRESTC BACKER BOARD Firestop Gypsum Backer is used as a back ing for decorative surface treatments of acoustical plasters, tile, plywood and various veneers. A single layer application of Vs" G-P Firestop Gypsum Back er on both sides of wood or steel framing, enables loadbearing or non-loadbearing wall assemblies to resist temperatures rising to 1700 F. in one hour following the ASTM standard time temperature curve. Firestop Gypsum Backer consists of a gypsum core with literally miles of high tensile strength glass fibres, firmly bonded to a fibrous gray paper on both sides. ----------------- ! -| Thickn*** Width* Length* Edg* Vi" ! 2' & 4' j 8'to 16' S, T&G -- ` G-P REGULAR BACKER BOARD G-P Gypsum Backer Board is designed for first or base layers in field lamination of gypsum board, for acoustical tile and other compatible materials. Pro vides low cost, even surfaces for further decorative treatments. It may be applied over loadbearing or non-loadbearing wood or metal framing with nails, screws or staples. 1----------------------- Thickn*** Width* Length* | Cdfl* %' 2'4 4*? 8' to 16' ! S.T4G Vi' _________ J 29 SGP 0023831 PREDEC " TEXTURED GYPSUM BOARD This combination of non-combustible gypsum board with factory applied, distinctive, evenly balanced textures is a new development in the construction industry. The textures are baked on and are available in 2 patterns, sand and stucco. The panels are ft*", Va" and V" thick with square edges. The texture is a thermo-set in White, Beige, Gold and Light Green water resistant paint. This product eliminates job site finishing and instal lation time. It is impact and abrasion resistant and ideal for residential construction, factory built mobile and modular homes and movable or fixed partitions. It can be cleaned with a damp cloth and mild soap and water. PreDec has a flame spread rating of 20. Samples available on request. This product also available without the texture under the name "PreDec Blanks." Thlckn*** 5/16' [Va " & H " special order) Width* 4' Length* cut to size Edge S SENTINEL BOARD Developed particularly for mobile homes, Sentinel board has a tough, stain resistant, special decorated paper face laminated to the wallboard. It has a 20 flame spread rating and its noncombustibility makes this product highly desirable for mobile homes. Patterns are Oak and Pecan designs. Thlckn*** 5/16" Width* 4' Length* cut to size Edge S SHAFT LINER ' SYSTEMS The shaft liner systems are non-load bearing gypsum board partitions for enclosing elevator shafts, stairs, smoke towers and other vertical openings. They are designed for resistance to air pressure (lateral force) without excess deflection. These systems can reduce weight over 20 lbs. per sq. ft., compared to masonry, are non-combustible and can be erected from one side, eliminating the need for scaffolding. They are also excellent fire rated separation wails. "T" Spline System: The partition consists of a basic factory or field laminated ITner panel 1 y*" thick by 24" wide which fits into a top metal "J" track and bottom "L" runner. Metal "T" splines separate each panel which is then screw attached to the "T" splines and top and bottom runners. The required facing layers are attached to the liner panel for the solid type, to furring channel for the cavity type, or to metal studs for the chase wall. G-P shaft liner panels are available in lengths up to 16 ft. With splicing and auxiliary bracing, heights beyond 16 ft. are attain able. Various fire resistant ratings in accordance with ASTM E-119 and sound ratings in accordance with ASTM E-90 are available. Fire tests were con ducted by UL and Ohio State University. "I" stud System: This partition consists of a single shaft liner board 1" thick by 24" wide which fits into a top metal "J" track and bottom "U" track. Metal "I" studs 2Va" deep separate each shaft liner board and have opposed tabs 12" o.c. The 1" shaft liner panels are secured by a friction fit between the tabs and the flange of the T' stud. A cavity space 1 Va" deep is provided and the cut-outs in the studs facili tate horizontal services. The required 5/a " Firestop facing layers are screw attached to the face of the "I" stud. Height limit varies depending upon gauge metal and depth of stud. Fire resistance rating is two hours based on ASTME-119 test. Thickne* 1%" or r Core plus facing layers Width* 2' Length* cut to size Edg* S G-P 1" COREBOARD 1" Gypsum Coreboard is available in two styles. a. A homogenous core with a tongue and grooved joint. b. Two layers of Va" backer board, laminated. 1" Gypsum Coreboard is used for the core material in various, all-gypsum partition assemblies. Thlckn*** | Width* i 1" j 2' Length* Custom cut up to 14' Edg* S.T&G ____ G-P SOFFIT BOARD G-P Gypsum Soffit Board is used on exterior soffits where not exposed directly to the weather. It's an in expensive soffit material for schools, shopping cen ter malls, apartments and houses. It finishes and decorates like interior gypsum board with no nails or joints showing. It has light blue face paper for identification. Thlckn*** Widths ______________ i Lsngths CD Edg* RE G-P FIRE FIGHTER GYPSUM BOARD New product designed for use on roofs, over rafters, and under sheathing and roof covering. Tests prove it blocks roof fires from entering attic and living areas. It has a special core and paper. Thlckn*** Width* Length* Edg* %" 2' 8' 5 DENS-COTE GYPSUM PLASTER BASE A 4' wide, long length, tapered edge, plaster base. For use as a base layer for G-P Dens-Cote* veneer plaster. It has a highly absorbent face with pinholed surface. 30 SGP 0023832 Georgiaftcific ^ 9.6/Ge Thick imm 3/s". Vi" %'' Reg. and Vt " and % " Fi restop r Widths 4' Lengths 8\ 10', 12' Edgs T DENS-COTE* VENEER PLASTER One coat and two coat systems give a strong dur able finish with maximum speed and minimum ma terial. Apply total thickness of ft;". Available in smooth or textured finishes. 80 lb. bags. TAPERED EDGE: ------------------- The tapered edge was originally l r' I called the "recessed edge" but is now commonly called tapered. because of the incline from the edge to about 2" into the board. This taper allows space for tape and joint treatment to be applied and the completed job will be flat, smooth and monolithic. SQUARE EDGE: r~~^ The gypsum board square edge t 1- -- was the original wallboard edge. Initially designed to be a base with -------------------a final covering such as wallpaper, paneling, or tile, square edge can be finished with joint compounds to form a clean monolithic wall suitable for paint. Also can be used where an exposed joint is desired. TAPERED w/ROUND EDGE: Georgia-Pacific round edge (RE) gypsum board can be used for wall and ceilings in both new construc tion and remodeling. It is designed to reduce the beading and ridging problems commonly associated with standard type gypsum board. The edge forma tion provides a stronger, more rigid joint and reduces joint beading or ridging. BEVELED EDGE: The beveled edge is a suitable r~ edge to give a paneled effect. After fasteners are covered with joint compound the board is ready for paint with grooves exposed. "T & G" EDGE/ Georgia-Pacjfic's "tongue and groove" edge is used on 2' wide sheathing and backer boards. MODIFIED BEVELED EDGE: The modified beveled edge is T--1 available only on Eternawairu panels. This particular edge more readily accommodates the vinyl surface decoration, which is delivered completely edge wrapped. The vinyl surface material is available in 15 standard patterns and colors and 15 new colors and textures. vwim 9T9IBIW PRODUCTS G-P Joint System products are designed to conceal joints and nail heads and "surface-weld" gypsum board panels together. Properly used, these products assure smooth, seamless appearance of walls whnahrHan.,n2?*Ls;rtrMthyf^LinP,sfi0si,nrot ns9yse,relmhapnrothaeug^yspscuomme cn"k ""h G-P BEDDING COMPOUND Bedding Compound is designed to orovide maxi OlicatfodnhtoSn0^ihf ,a2,0 ,he |0in,s and for mitfal ap- 2? 0 5 heads and corner bead It soreads Coveraa."^ lasnbithand or machine applied, coverage. 15 to 20 lbs. per 1,000 sq ft (Used in 45 ISs-01 G-P TOPPING COMPOUND G-P Topping Compound is specifically designed for the second and third coats over the bedding com pound. Since it is used only for topping, the amount of adhesive can be reduced and other materials in corporated which reduce the shrinkage and make it easier to sand and work. Coverage is approximately 40 to 45 lbs. per 1,000 square feet. (Used in con junction with 15-20 lbs. of G-P Bedding.) Available in 25 lb. bags. TRIPLE DUTY " JOINT COMPOUND Triple Duty Gypsum board Joint Compound is a vinyl multipurpose joint system product. A single bag offers taping, topping and texturing. It can be used for all coats in the reinforcing and concealing of joints in gypsumboard construction. The binder, a vinyl, gives this product a wet life of 30 to 60 days duration. This allows premixing in large quantities prior to application. Triple Duty can be applied using standard hand or mechanical tools. There is low shrinkage and it is easily sanded. When the applica tion is completed, the surface is ready for priming and decoration as desired with no further prepara tion necessary. Coverage: 60 lbs. per 1,000 sq. ft. 25 and 50 lb. bags. Can be used as a Texture. Cov erage: 12-50 lbs. per 1,000 sq. ft. G-P READY MIX JOINT COMPOUND Ready Mix Joint Compound is an easy-working ma terial for embedding the joint reinforcing tape and the filling and finishing of joints in gypsum board construction. Furnished in cans and cartons ready to use, this stable, all-purpose compound is also ex cellent for use in covering nail heads and forming interior and exterior angles. Ready Mix Joint Com pound assures a standard mixture for uniform work ability throughout the job. it has a long wet life and will not spoil even when the container is left open. Ready Mix Joint Compound produces an excellent surface for any type of decoration. Ready Mix Topping Compound also available. For best results, the surface should be primed before being deco rated. Coverage: 5 gal. per 1,000 sq. ft. Package-- 1 and 5 gal. cans, 4 gal. cartons. G-P ALL PURPOSE JOINT COMPOUND G-P All Purpose Joint Compound is used for bed ding tape, topping, corner bead, nail spotting and texturing. When taping be sure the compound under the tape, and the first coat over the tape is thorough ly dry before applying the next coat over the joints. When used for texturing, for best results, apply a 31 SGP 0023833 befo roller, on the I bs^er *>l [A 40 lb. bag of this aggregate is avail- in 3 lie sizes (fine, medium and coarse). An ideal p. TMict for concealing surface defects. Coverage: 2j#-300 sq. ft. per bag. Texture samples available oinSquest. mpound me^B possible the /X Speed SefJ- taping and of all gyflSUOLboard joints within a single ^ty; tats. Spi is a setting if comp and will not mes in ways--for 1 tear eed Si for 2 hour 150. 2S Lb. Beg. Wall Texture is an umggregaterfti ' for hand tool or spray applicati ith a spray, a splatter or oral . When applied by hand, a ie texture can be produced. e com- ten ap-i I texture^ :swirl, or __ I Texture can be ap # G-PCeHing overspray wip< "lfttrtiiteli~iti~n Bacau_ Wall matches'S-P C__. lows ttSfcto blend togethee^ ter tmade for fast, G-P al- Coverage: 12-50 lbs. pari ,000 sq. ft. -upon teodugyflm. Ba$ CEIUN#Y|AIURE9 ^ G^CeHingflBRires are designed ^spfqya^fr cation oveafflfings constructed wil^gypsum board"" or concreta^toreaulting texture simulates acousti cal texture finish. Ttftfityr^-A new powder product in a 32 lb. bag. richwraj| texture finish has strong adhesion aximuflt coverage and excellent hiding qualie fragments of this very rough texture retain e andahape during mechanical mixing. Cov"0-^3 sq. ft. per bag. !y designed for volume operations, these give unsurpassed economy. The texture hatde^nd tighter. The texture maintains a high Itty whitifflecorative finish, and gives exceptional jaweragejljped as instructed. OARD TAPE _ffull 2' width, "Miracle Crease" spark State wit skived edges and sanded surfac*boffi rafts. Ex .ellent bonding qualities. Avafaaleln 60', 25 and 500' lengths. |S--Smooth (no agfFegate) ^"l^^Medlum 32 20 minutes. Remix and adjust to Ided, per bag, to impart color. SGP 0023834 ETERNAWALL" GYPSUM BOARD COMBINES GYPSUM BOARD WITH THE BEAUTY OF SHEET VINYL 3? These fire-resistant panels are factory laminaterf=- with a quality, washable vinyl sheet providingaoeT-* manent scuff, crack and chip-resistant surface Col *- ors are fade-resistant and the texture or desiqn win* not be impaired when cleaned. - Etemawall panels are available in 16 standard ? colors; 2 simulated woodgrains plus 14 new vinyl colors and fixtures. The long edge is completely wrapped with vinyl and eased to form a modified. beveled edge*. Georgia-Pacific Firestop* EternawallTM Gypsum' 'in board is available for use when the wall construe-^* tion requires the gypsum board to be of fire rated ' construction. Firestop* Etemawall'*1 has a gypsfun board base containing greater glass fiber reinfi ment. J*. Classified tar U UL labeled ttei SPECIFICATIONS ^^ All vinyl surfaced gyps'.m board scheduled and/ort indicated on the drawir gs shall be Georgia-Pacific EternawallTM as manufactured by the Gypsum Divi sion of Georgia-Pacific Corporation. The panel con struction shall consist of supported or unsupported ^ vinyl of "wall surfacing grade" factory laminated G-P Regular or Firestop^ Gypsum board. The fong^ panel edges shall be a modified bevel and completely wrapped with vinyl. The colors and patterns shall be as selected from the Eternawallru Gypsum board Standard Line or special new colors and ' textures. (See page 34 for colors.) ~ Modified Beveled Edge Color coated stainless steel nails are available to match all Standard colors and woodgrains. Trim ac cessories are available in 8' and 10' lengths to match all standard colors and woodgrains. Snap-On Comer Bead Snap-On I ^ Etemawall"* , Gypsumboard StSgpMjHM&re and sound rated vinyl-surfiSSd gyjjRHfi boanlllfbNms eliminate the nee^Bp battens. Firestp*=ftern&waH'M is laminateawecHy to G-P 'A^lncomStNfile Gypsum SouoCDeadenfhg Board. They are not only simple to-ftwtalt but they are inexpensive and provide a very durable wall, and vtsf high STC- ratings. i* 'tGUtNO INSULATION DEMOUNTABLE PARTITIONS ^ Demountable wall systems are installed by using arty of the appropriate or approved color-matchedmo ings. To laminate to existing wall surfaces, use G-PLaminating Compound and secure panels meef ically at top and bottom plates. Panels may be applied with adhesive directly to metal studs, framing or furring strips. Swatches are available by writing Georgia-Pacific Corporation, 900 S.W. Fifth, Portland, Oregon 97204. Fire Test U.L. t*2 Fire Rating--1 Hou. __________ STC 50 System5KB 3jT' -- * InsulatiorwtBt required fMu rating Fire Test I Fire I__ STC 50' _ _____ Incombustible System #30& SGP 0023835 ETERNAWALLM vinyl surfaced gypsum board Stucco GP-705 Group I Group II Alabaster GP-703 Group It -- - ,-ag - - Fiel&Grass GP-808 Grot/a // Autumn Thatch GP-809 Group II Golden Reed GP-810 Group II Espana GP-811 Group It SGP 0023836 GtoorgiaJtocific ^ U.3. AND CANADIAN SPECIFICATION DIRieU%> QY^flf BOARD PRODUCTS 9.6/G0 Q-P REGULAR GYPSUM BOARD Square, Tapered or Round Edge Q-P INSULATING GYPSUM BOARD Square, Tapered Edge or Round Edge ETERNAWALL" GYPSUM BOARD Modified Beveled Edge FIRESTOP GYPSUM BOARD Square, Tapered Edge or Round Edge y` W V* ' " ' %' V2" %' 4' 4' 4' 4' 4' 4' 4' Vi" 4* ' tb 12' 6' to 16' 6'to 16' 6'to 16' 6'to 16' 6' to 16' 6'to 16' MTMACSA Standard* C 36 CSA -32.27 8' Std.t USDS I ... SpBCMdttOII SS-L-30d Type III--Grade R SS-L-30d Type III--Grade R SS-L-30d Type III--Grade R or Grade X Class III SS-l-30d Type til--Grade X FIRESTOP INSULATING GYPSUM BOARD Square, Tapered Edge or Round Edge tStandard Length--Other Length* on Order. All ASTM Standard*--Per Uteat Revision. All Canedlan Slandarda In Blue CC CODE ACCEPTABILITY CERTIFICATION WARRANTY The assemblies and information in this brochure hava been developed on practical construction mtthods. However. smea tha Georgia*Pscific Gypsum Division dots not hava any prior knowledge of a spacific building design and its construction or tha mtthods of application usad with its products, no warranty of parformanca is SGP 0023837 DI3TRISUT10N CENTERS 690 Qstihom Or. (713) I7S-1721 f 702 Essi 441* St. (606) 747*3020 tM IhtSSlS 339 North IN W Whit* Ad. Tjtsr<512) 333-S110 9OtwhoSmtroswsnt A Lswnon Avs. (214) 677-3101 UTAH Salt Lsk# City 297$ S 300 W. '901) 460-6201 vepmont P'9^4*ir Short Roof Shaibums, Vt. (902) 909-2911 VlftaiNIA G'tvos Mill Ad. Timos risks (604) 230-0241 Norfolk 200 Pneo Si Virginia Bosch '904) 460-S901 Comor Osknsy A Bothiohom Rot. 1604) 399-9107 WASMINOTON 929 Cornwall Avsnus '2001 733-0000 12019 HE. tTOth St. Woodirmlis (206) 4004741 Sssksss 901$ C. Missos (506)920-3030 2302 Ross Wsr 200) 303-4970 WASHINGTON. D.C. WasMsoiss. B.6. 6121 Afdwick-Artfrssrs Rood isnddvsr. Maryland (301) 322-2270 Wool WmMMMS. 0.6. 11600 Bolts Ford Ad. Mtnossss. Virginia 1703) 301-9147 WCBT VIRGINIA 7061 CSHOOS P (213)007- OsoshoiJsSMSSOMiriio. (400) 267-r um 3417 (707) $44-3040 COIOAAOO 3000 USI4A St. (303) 371-1900 LOUISIANA slss RSSfS iQli loatvui* St. (904) 343-7401 2969 Wsidsn Avs. (716) 669-2323 i Hudson River Or. 1914) 2714201 Mi ITM DAKOTA Otoss Polls 4501 NO 4|h (MSI 336-6300 trlslsl iQO Paty Indus. B>vd. (619) 606-4121 Rock 0ranch Ind. Ph. Poes. W. vs. t304) 7994193 WIOCOMOIH *33 Mayfair Avs. 6001 241-3074 Mllwaaln* 5059 North 116th St *14) 404-7600 909 S 92nd Avs. 715) 942-0051 Canadian (randwt Gtorgis-Pscifie Outiding Maisriais. LTO. C* 770 North Mats 0. MSSChSStSf^eORR. <12031 -------------- GeorgiaFfecific 900 S.W. Fifth Avenue Portland, Oregon 97204 ^ SGP 0023838 Liths in U.5.A.