Bendix
NIOSH CERTIFICATION NUMBER TC-84-014
Has been granted For Carbon Monoxide tube No. ILa for use with the BENDIX/GASTEC PRECISION PUMP
Effective September 10, 1973
PRECISION GAS DETECTOR SYSTEM
The introduction of this new system is the result of Bendix/Gastec exper ience and engineering superiority, combining the two proven most effective components for the precise sampling and detection of toxic gases, vapors
. (1) accurate readings are made directly on the tube's calibrated scale and (2) a piston-type volumetric pump.
No other system offers this combination of pump and tubes, producing ease of reading and reproducible, reliable results.
Tube No.
81 151 171
191 3H 3M 31 181
12! 142 2H 21 2LL 13
Detector Tube
Acetic Acid Acetone Acetylene Acrylonitrile Ammonia Ammonia Ammonia Aniline Benzene Butyl Acetate Carbon Dioxide Carbon Dioxide Carbon Dioxide Carbon Disulfide
Chemical Formula T.L V.
ch3 cooh (CH3)2C0 c2h2
ch2chcn nh3 nh3 nh3 C6Hs C,,Hs CH3C00C3H9 C02
co2
CO, CSa
10 PPM 1000 PPM 1 PPM
20 PPM 25 PPM 25 PPM 25 PPM 5 PPM 25 PPM 150 PPM 5000 PPM 5000 PPM 5000 PPM 20 PPM
Calibration Scale
2-40 PPM .01-0.8% 0.2-2.0%
10-500 PPM 1.0-16% 50-500 PPM 2-30 PPM 2-30 PPM
10-200 PPM .01-0.8% 1 0-10% 0.1-3.0% 300 5000 PPM 5-50 PPM
Measurable Concentration
1-80 PPM .01-1.6% 0.1-4%
10-500 PPM 0.2-32% 50-1000 PPM 1-60 PPM 2-30 PPM 10-200 PPM .01-0.8% 1.0-20% 0.1-6.0% 300-5000 PPM 5-50 PPM
Pump Strokes for Measurable Concentration
1/2 -2 1-2 1/2 2
5 Strokes Only 1/2 -5 1/2 -1 1/2 -2 2 Strokes Only
1 Stroke Only 2 Strokes Only 1/2 -1 1/2 -1 1 Siroke Only 1 Stroke Only
Reagent ColorChange
Pink Brown White
Yellow Green Brown
Yellow Pink Purple Purple Yellow White Brown Orange Orange White Pink
Orange Blue Yellow Yellow Greer) Green Green Yellow Yellow Purple Yellow
hEMl 00uio*
Tube
No 1H 1L 1 La ILL 1M 8L 103 141 112 125 161 72 163 91 101 102H 102L 14L* 12H 12L 4H 4L 4HH 4LL 113 100A 111
Detector Tube
Carbon Monoxide
Carbon Monoxide
Carbon Monoxide Carbon Monoxide Carbon Monoxide
JC-84-014
Chlorine
Cyclohexane
Ethyl Acetate Ethyl Alcohol (Ethanol)
Ethyl Benzene Ethyl Ether (Ether)
Ethyl Mercaptan
Ethylene Oxide
Formaldehyde Gasoline
n-Hexane n-Hexane Hydrogen Chloride
Hydrogen Cyanide Hydrogen Cyanide
Hydrogen Sulfide
Hydrogen Sulfide
Hydrogen Sulfide
Hydrogen Sulfide Isopropyl Alcohol (Isopropanol)
L.P. Gas
Methyl Alcohol (Methanol)
Chemical Formula T.L V
CO CO CO CO CO cl2 c6h,, ch3cooc2h5 c2h6 oh c6h5c2h5 <c2h5)2o c2hs sh (CH2)2 0 HCHO CnHm CeH 14 ,CtHM HCL HCN HCN H2S h2s h2s h2s (CH3)2CH0H c3hb ch3oh
50 PPM 50 PPM 50 PPM 50 PPM 50 PPM 1 PPM 300 PPM 400 PPM 1000 PPM 200 PPM 400 PPM 20 PPM 50 PPM 5 PPM
500 PPM 500 PPM 5 PPM 10 PPM 10 PPM 10 PPM 10 PPM 10 PPM 10 PPM 400 PPM 1000 PPM 200 PPM
Calibration Scale
0.2-5 0% 50-1000 PPM 25-600 PPM 5-50 PPM 0.1-2 0% 1-30 PPM 0.03-0.6% 0.04-1.5% 0.1-2.5% 20-250 PPM 0.04-1.0% 10-120 PPM 0.1-3.0% 2-20 PPM 0.03-0.6% 0.03-0.6% 50-1200 PPM 2-20 PPM 0.05-2% 5-15 PPM 100-1600 PPM 10-120 PPM 0.1-2.0% 5-60 PPM 0.04-2.5% 0.02-0.8% 0.02-1.5%
/
Measurable Concentration
0.2-10% 50-2000 PPM 8-1200 PPM 5-50 PPM 0.1-4% 0.5-6D PPM 0.015-1.2% 0.04-1.5% 0.05-5% 10-500 PPM 0.04-1.0% 5-120 PPM 0.1-3.0% 2-20 PPM 0.015-1.2% 0.015-1.2% 50-1200 PPM 0.2-40 PPM 0.05-2% 2.5-30 PPM 100-3200 PPM 10-240 PPM 0.1-2.0% 0.5-6 PPM 0.02-5% 0.02-0.8% 0.01-3%
Pump Strokes for Measurable Concentration
1/2 -1 1/2 -1 1/2 -3 2 Strokes Only 1/2 -1 1/2 -2 1/2 -2 1 Stroke Only 1/2 -2 1/2 -2 1 Stroke Only 1 -2 1 Stroke Only 2 Strokes Only 1/2 -2 1/2 -2 1 Stroke Only 1/2 -10 1 Stroke Only 1/2 -2 1/2 -1 1/2 -1 1 Stroke Only 1 -10 1/2 -2 1 Stroke Only 1/2 -2
White Yellow Yellow Yellow White White Brown Brown Rose White Orange White Orange White Brown Orange Orange Yellow Yellow Yellow White White Blue White Rose Orange Rose
Reagent Color Change
Green Brown Brown Brown Brawn Orange Green Green Blue Brown Green Yellow Green Yellow Green Green Green Purple White Pink Black Black Brown Brown Blue Green Blue
ijENC 0 00 270
Tube No. 136 135 152 153 71 15L" 9L 111 13L 133 16 7 124 5H 5M
5L 122 132H
132L 131
6
123
Detector Tube
Methyl Bromide Methyl Chloroform Methly Ethyl Ketone Methyl Isobutyl Ketone Methyl Mercaptan Nitric Acid Nitrogen Dioxide Nitrogen Oxides Ozone Perohloroethylene Phosgene Phosphine Styrene Sulfur Dioxide Sulfur Dioxide
Sulfur Dioxide Toluene Trichloroethylene Trichloroethylene Vinyl Chloride Water Vapor Xyfene
Chemical Formula
TLV
CH,BR
15 PPM
ch3ccl3
350 PPM
CHaCO^H..,
200 PPM
CH2 CQCH,, CHICFUU 100 PPM
CH3SH
10 PPM
hno3
2PPM
no2 no+no2 03
5 PPM
NO-25 PPM NOz-5 PPM
0.1 PPM
CCL2:CCL2 cocl2 ph3 CeHs CHCH2 S02 S02
so2
c6hs ch3 CHCL:CCL2
100 PPM 0.1 PPM 0.3 PPM 100 PPM 5 PPM 5 PPM
5 PPM 200 PPM 100 PPM
CHCL:CCL2 ch2chcl h2o CaH,,(CH3)2
100 PPM 500 PPM
100 PPM
Calibration Scale
10-100 PPM 100-500 PPM 0.02-0.6% 0.01-0.6% 5-70 PPM 2-20 PPM 30-100 PPM 2-100 PPM 0.5-3 PPM 50-200 PPM 0.1-10 PPM 50-500 PPM 20-500 PPM 0.5-4.0% 100-1800 PPM
5-100 PPM 20-250 PPM 50-200 PPM
2-25 PPM 0.05-1.0% 2-18 MG/L 20-250 PPM
Measurable Concentration 10-200 PPM 100-500 PPM 0.02-0.6% 0.01-0.6% 2.5-70 PPM 0.2-40 PPM 15-100 PPM 2-100 PPM .05-3 PPM 5-200 PPM
0.1-90 PPM 5-1000 PPM 10-1000 PPM 0.05-8.0% 100-1800 PPM
1-200 PPM 10-500 PPM 50-200 PPM
1-50 PPM 0.025-2% 1-36 MG/L 10-500 PPM
Pump Strokes for Measurable Concentration
1/2 -1 1 Stroke Only 2 Strokes Only 2 Strokes Only 1 -2 1/2 -10 1-2 1 Stroke Only 1 -10 1 -10 1/2 -5 1/2 -10 1/2 -2 1/2 -10 1 Stroke Only
1/2 -5 1/2 -2 1 Stroke Only
1/2 -2 1/2 -2 1/2 -2 1/2 -2
Reagent Color Change
White White Brown Brown White Yellow White White Blue Yellow White White White Orange Pink
Yeilow Orange Green Green Yellow Purple Orange Yellow White Pink Red Yellow Yellow Green Yellow
Pink White Yellow
Yellow Brown Pink
Yellow Brown Green White
Pink Green Purple Black
All tubes should be refrigerated below 10 C (50 F)
Each box of Detector Tubes contains Quality' Control Number, T.L.V., Shelf Life, and Interferences.
" Since the indication of the tubes is based on water content in the test air, measurement of water content is required before test. Use Water Vapor Tube No. 6.
j jr 0 00 21
PRICE LIST AND ORDERING INFORMATION
NUMBER
QUANTITY
Pump Kit
1-5
2417534
6 or more
Detector Tubes 10 per box
1-5
6 or more bxs
$75 00 72 00
9 85 9 55
THE BENDIX/GASTEC PUMP KIT INCLUDES Pump, carrying case, spare parts kit, & laminated instruction card
2417536 2417538
2417539 2417535-0023 2417535-0021 2417535-0008 2417535-0022 2417535-0007
REPLACEMENT PARTS
Carrying case Spare parts kit contains
2 Rubber Tube Holders 1 Lubricant 1 Piston Ring Seal Instruction Card Lubricant PistonRingSeal Tube Holder retainer nut PumpCylinderSeal Rubber Tube Holders
8 90 8 95
1 20 3 60 4 50 1.50 1.25
45
Bendix/Gastec offers a wide selection of tubes for sampling a variety of gases and vapors, each displaying a precision, direct reading calibration scale. Every tube and tube box displays a quality control number and chemical symbol and unit of measure as required by the Federal Register, Vol. 38, No. 88,5/18/73.
The compact Bendix/Gastec Precision Detector System is enclosed in a durable zippered case which can be conveniently carried in a pocket or worn on the belt.
The case provides ample space forthe pump, accessories, laminated instruction card and supply of tubes.
Uniformly small grain-sizeof absorbing media insures uniform flow rate and uniform flow distribution. Sensitive reagent with high reaction rate provides clear line of demarca tion of color stain Controlled inner diameter of tube insures consistently accurate tube readings.
ALL BENDIX/GASTEC TUBES ARE IN STOCK FOR IMMEDIATE SHIPMENT
BENDIX/GASTEC PUMP GUARANTEED 5 YEARS.
A fifteen foot long extension hose is available as an accessory. This hose is used for taking remote samples from manholes, tanks, con duits or other areas which must be sampled prior to entry
A deluxe shoulder bag carrying case holds the Detector Pump, a large quantity of tubes and the extension hose.
The Hot Probefnot shown) is used to take a sample of hot gas or vapor, and cool it down before the gas enters the detector tube
2417541 2417542 2417540
ACCESSORIES
Hot Probe 15 foot Extension Hose Shoulder Bag Carrying Case
31 50 39 50 23 00
NATIONAL ENVIRONMENTAL INSTRUMENTS, INC.
OCCUPATIONAL HEALTH. AIR POLLUTION & SAI'ETV INS THUMENTATION P.O. Box 690, Warwick, R. I. 02888 Tel. {401) 738-3710 TWX 710-387-1548