Document XOrVmoDDe7N14y65r0a9xrw5J

cn tu w w oh-> ^ vO K ~J 0 cn M Qj c o rt w f-! O O t* c i-S CD 03 PLAINTIFF'S EXHIBIT SGP 0023081 1972 gypsum wanooara ' for wall and celling systems n jj O N. S' ^; 9a 2? 33 U A. 31 r: o a<8. 9 9awOi a i 1 i ( i - -i. m SGP 0023082 INDEX Q-P Wallboard Products Description........................... 3,4,5 Q-P Wallboard Edga Oascription .........................................5 Q-P Joint Systam Products Oascription.......................... 5, a Wall & Column Construction Data............7,8,9,10,11 Floor & Calling Construction Dats..................................... 12 Specification Directory..........................................................13 Systam Installation Details................... 14,15,16,17,18,19 Water Resistant Wallboard................................................. 20 Column Fireproofing ............................................................20 Masonry Wall Application................................................... 21 Specifications for wood or metal framing......................... 22 Orywall Nails and Screws................................................... 23 Etemawailr'< Vinyl Surfaced Wallboard............................. 24 Q-P Shaft Liner"*............................. 25,28,27,28,29,30,31 Qeorgia-Paciflc Distribution Centers.................. back cover aCOVER: 40 Mery First Nttlonsl Bank Building. Portland, Oregon. Charts* Utekman Aaaoeiataa, AreAltacta, Lo* Angsts*. California WARRANTY / . ^ r The assemblies shown in this brochure and information there-to, have been developed with due regard to practical construction methods. However, since the Georgia-Pacific Gypsum Oivisfon does not have any prior knowledge of a specific building design and its construction or the methods of application used with its products, no warranty of per formance is made. All test results have been obtained under controlled laboratory testing conditions where environmental variables are reduced to a minimum. In the field, such lab oratory conditions are not always met, since many other variables may be Introduced. Laboratory results may exceed field test results but the laboratory tests under controlled conditions are the only logical way to compare the perform ance of different assemblies. The Gypsum Division of the Georgia-Pacific Corporation makes no warranty that the performance of assemblies in the field will have a performance equal to or better than that developed In the test TESTING FACILITIES 3 Georgla-Pacific's major research and development center, a showplace for the nation's gypsum industry, is located at Tigard, Oregon. The two buildings house research, technical operations and the administrative offices. Since most of the research work is of a confidential nature, there are no "public tours" such as the company conducts at many of its manufacturing plants. The new facility replaces former research and development facilities located for many years at Paoli, Pa., near Philadel phia, where G-P's gypsum division headquarters were located before they were moved to Portland. The two adjacent structures, with 16,868 square feet of floor area, are equipped with many types of research and testing devices. Sixteen staff technicians under the direction of a research and development manager, and a technical manager, de velop new products and maintain quality-control for prod ucts ranging from gypsum wallboard, Firestop with fire rat ings up to three hours, sound deadening board, Denscote plasters, to joint systems and even dental plasters. G-P holds patents on several developments such as use of glass fibers to strengthen gypsum wallboards, high strength ensite piaster and special lath for veneer piaster. Other patents are applied for, and the lab is carrying on a vigorous product development program. The technical department conducts field and manufacturing plant services, solving difficult technical problems and de velops Improved manufacturing methods; Gypsum products are tested several ways at the Tigard lab. Wallboards are subjected to severe stresses and extreme temperatures to make stronger and more fire resistant gyp sum products. Sound tests are conducted to develop wall and floor/ceiling systems to assure "sound privacy" for today's residential and commercial construction. Basic research includes gypsum crystal studies and the mechanics of hydration. Technicians continually check such G-P gypsum products as Tile Backer board for installations where water is preva lent, insulating boards, vinyl-surfaced Etemawall, and other products including partition assemblies, plasters, pottery and metal moulding plasters and agricultural gypsum for farm applications. LIMITATIONS ^ Georgia-Pacific interior gypsum wallboards are non-load bearing panels and are not recommended for use under extremely moist conditions. G-P Tile Backer Board, how ever, is the only exception to the moisture limitation. Vs" wallboard should only be used as an application over exist ing walls. Maximum framing spacing for gypsum wallboard up to thick is 16" on center. Maximum framing spacing for Vi" and % " panels is 24" on center. Because of the limitations of manufacturing equipment, the maximum length available In gypsum wallboard is 16 feet E/2 SGP 0023083 WALLBOARD PRODUCTS 7 Georgia-Pacific Gypsum Division manufactures a full range of products to meet the needs of the construction industry both specific and general. The versatile gypsum product provides builders with lightweight construction materials that are workable, fire and noise resistant and time saving. G-P research facilities have responded to the industry's requests and have developed the following multi-use, highly reliable, low cost products. G-P WALLBOARD EDGES T--Tapered S--Square RE--Tapered with Round Edge B--Beveled (Special Order) T & G--Tongue end Groove V--Modified Beveled Edge PRODUCT DESCRIPTION G-P REGULAR WALLBOARD G-P Regular Gypsum Wallboard is faced with a strong, cream-colored paper which will accommo date any type of decorative treatment. The back paper, which is gray, is as strong as the fact paper. The Vi' and %" wallboard with Tapered Round edges are recommended for single layer application in new construction. They are designed to be rainfOrcad with G-P Joint System prod ucts resulting in a smooth, seamless surfaca. Square edges are recommended for use where exposed joints are acceptable. The resistance to fire exposure and sound transmission increase with the use of greater board thickness and the number of layers of board used. Bevel edge can be used where a panel effect is desired. TMctam Widths Lengths p. :/ K" 4' r Vi" H" \--V" ' * - ^ 6'to 16' T,S,B,RE in even i feet 1 G-P^FIRESTOP^WALLBOARD G-P Firestop carries e 45 minute to 3 hour fire resistant rating in various wood and steel wail and floor/esiling assemblies. Unexpended vermiculite in the core balances gypsum shrinkage by expanding when exposed to heat while the textile glass filaments keep the core intact even after its chemically combined water has been released, giving a thermal stabilized core. -V r 4' 6'to 16' T, S, B, RE r in eves feet j G-P>/4'SiGYPSUM SOUND DEADENING BOARD G-P l/" Incombustible Gypsum Sound Deadening Board meets the requirements of the most sophisticated sound control systems available with the added convenience of being one of the easiest sound control materials to install. It is designed and formulated for high sound trans ( mission loss, structural strength and incombustibility. It has a distinctive green face paper. When applied over 2Vi" steel studs or 2x4 wood studs, one layer of Vi" G-P Firestop Type XXX over one layer of */" Gypsum Sound Deadening Board gives a 1-hour fire resistive wall and a 45 S.T.C. W' *.v 8' G-P REGULAR TILE BACKER BOARD This is a water-resistant gypsum product with a light blue face paper, designed for use as a base for the adhesive application of ceramic, metal or plastic tile. The gypsum core consists of incom bustible gypsum rock, combined with an emulsion giving high water resistance. Ideal for bath rooms. kitchens, powder rooms and other moisture areas. G-P Tile Backer Board can ba erected as easily as regular wallboard and requires no finishing of joints or nail heads with joint treatment nor further waterproofing under tile applied adhesively unless required by local code. r 4' 8'to 12' G>P;FIRESTOP"*riLE'BACKER BOARD Same as Regular Tile 8acker Board plus the addition of unexpended vermiculite and glass fiber H" 4' 8' to 12' reinforcement which gives increased fire protection end strength. Where fire rated assemblies are required in arees subject to moisture, such as partitions between bathrooms and other interior areas, most building codes allow the use of G-P Firestop Tile Backer Board. The use of %" Firestop Tile Backer will give the same fire resistant rating as other firestop board. G-PiREGULAR INSULATING WALLBOARD ^ Regular Insulating Gypsum Wallboard is regular gypsum wallboard, with bright aluminum foil laminated to the back surface. In a single layer application it provides the advantages of regular gypsum wallboard plus having effective insulation and vapor barrier qualities. A separate and continuous vapor barrier is sup plied on the werm side of the wall when G-P Insulating Gypsum Wallboard is installed. The aluminum foil, facing a Vi" minimum space, reflects 90% of radiant heat, providing insula tion qualities equal to Vt ~ of fiberboard insulation (tested by U. S. Bureau of Standards). Panels must be installed with foil side against the studs. To have reflective insulation value, FHA requires the foil to face a minimum air space of Vi'- ( KT-P^FIRESTOPTHNSULATING WALLBOARD r 4' 6' to 16' T, S, RE w r This is the regular insulating gypsum wallboard with the addition to the core of unexpended vermiculite and glass fiber content for increased fire protection. Through the proper use of this product desired fire-rated assemblies can be achieved. r . 4' 6' to 16' T, S, RE E/3 SGP 0023084 PRODUCT DESCRIPTION T G-P REGULAR ETERNAWALLTM--VINYL SURFACED WALLBOARD Standard Uim Colon Avocado. Sold, Flu, Whitt, Beige, Stucco, Buff. Wlllnr Orton, Fawn, Snowdrift White, Alabaster, Tangerine, Chany, Ptcan and American Walnut This panal has tha vinyl surfact factory laminatad to Regular Gypsum Wallboarl Availabla in a variety of colon and textures, it providas beauty and utility to commercial, institutional and homo Interiors, Etamawall is strong and resilient The solid gypsum core is incombustible. Etemswalt colon won't fade. The deep linen-textured vinyl surface can be scrubbed without damage to color, texture or design. Bacausa of its ability to taka hard wear and to resist stains, Etemawall is ideal for restau rants, hotels, dubs; and hospitals as well as homo use. It Is also ideally suited for moveble partitions. > 4' r (Spadai ontor ra*.* 4' 8' (Other lengths available on special order.) V G-P FIRESTOP' ETERNAWALLTM--VINYL SURFACED WALLBOARD : t_* V* This panel has the vinyl surface factory laminated to a FIrestop panel which has unexpended vermicuiits and glass fibers added to tha core to give it additional fin resistance. With this tech nically designed gypsum con, a 1 hour or greater fin rating may bo obtained on wall assemblies. Same colon available as with regular EtamawaH. . 1- h L 4' 8' (Other lengths available order.) G-P FIRESTOP* GYPSUM SHEATHING - Treated C-P Firestop Gypsum Sheathing consists of incombustible gypsum rock combined with an asphalt emulsion to provide high resistance to water. All G-P Firestop Gypsum Sheathing meets ASTM C79-67, induding requirement for water resistance. This eliminates the need for building paper (except when required by local building code). An untreated gypsum sheathing is available. The 2' wide sheathing is made with precision-cut tongue and groove edges to provide a structurally strong and stable wall. "V" tongue and groove edges fit snugly, minimizing wind infiltration. The 4' wide square edge sheathing, applied vertically, completely eliminates the need for comer brac ing. It is designed to meet requirements of FKA Technical Circular 12. Vs--S' - " ctv-. . ry r'g ' ' * -* .7 ' r 4' V V V T4G S G-P GYPSUM FIRESTOP BACKER BOARD - G-P H' Firestop Gypsum Backer is used as a backing for decorative surface treatments of acoustical plasters, tile, plywood and various veneers. A single layer application of %* G-P Fire stop Gypsum Backer on both sides of wood or steel framing, enables loadbearing or non-loadbearing wall assemblies to resist temperatures rising to 1700* F. in the ASTM standard time temperature curve lor one hour. Firestop Gypsum Backer consists of a gypsum core with unexpended vermiculite, reinforced with literally miles of high tensile strength glass fibres, firmly bonded to a fibrous gray paper on both sides. - 1 rt 4' 8'to 16' S.T4G G-P REGULAR BACKER BOARD G-P Gypsum Backer, designed for first or base layers in field lamination of gypsum wailbeards. for acoustical tile and other compatible materials. Provides low cost even surfaces for further decorative treatments. It may be applied over loadbearing or non-loadbearing wood or metal framing with nails, screws or staples. ; \ % 2* *4' 8'to 16' S.T4G PREDECTM TEXTURED GYPSUM This combination of non-combustible gypsum wailboard with factory applied, distinctive, evenly balanced textures is a new development in the construction industry. The textures are baked on and are available in 2 patterns. Tha panels are ft', V4* and %* thick with square edges. The texture is a thermo-set water resistant paint availabla in beige, yellow, white and light green. This product eliminates job site finishing and installation time. It is impact and abrasion resistant and ideal for residential construction, factory built mobile and modular homes and movable or fixed partition* It can be cleaned with a damp doth and mild soap and watar. PREDEC has a flame spread rating of 20. 5/16* special order) v. f \\ 4' cut to sizs S SHAFT-LIN ERTM i .-r : G-P Shaft Liner is a solid, laminated gypsum board partition for enclosing elevator shafts, stairs, smoke towers and air ducts. It is a non load bearing wall, designed for resistance to air pressures without excess deflection. This system can save over 20 lbs. per squsra foot over mesonry and is noncombustible, can be erected from one side and eliminates the need for scaffolding. The partition consists of a basic preiarninated core 1H" thick by 24* wide which fits into a top metal "J" track and bottom "L" runner. Metal`T* splines separata each core unit; and the shaft liner is then secured to the 'T' splines and both top and bottom runners. This system was fire tested in accordance with ASTM El 19-67. G-P shaft liners available in lengths up to 16', but with G-P's own auxiliary bracing system heights beyond 16' are attainable. Various fire resistive ratings available. : 1H* Core plus facing layers 1 1 r ait to size s 1 1 E/4 SGP 0023085 PRODUCT DESCRIPTION G-P 1" COREBOARD 1 * Gypsum Coreboard is available in two stylo. a. A homogenous com with a tongue and grooved joint b. Two layan of backer board, laminated. 1' Gypsum Coreboard is used forth* core material in various, all-gypsum partition assemblies. G-P SOFFIT BOARD G-P Gypsum Soffit Board is used on exterior soffits where not exposed directly to the weather. It's an inexpensive soffit material for schools, shopping canter mails, apartments and houses. It finishes and decorates like interior gypsumboard with no nails or joints showing. It has light blue face paper for identification. G-P FIRE FIGHTER GYPSUMBOARD New product designed for us* on roofs, over rafters, and under sheathing and roof covering. Tests I prove it blocks roof (Ires from entering attic and living areas. It has a special core and paper. TNckaess WMlUt \ * *' " , , *- *'^v' - r *. i- t lengths cut up to 14' Edge S.T4G r -;: - - -:r - 4' 8' RE i *' - . r 8' S TAPERED EDGE: r*~'T: * 1 _______________ The tapered edge was originally called the "recessed edge" but Is now commonly callsd tapered, because of the Incline from the edge to about 2" Into the board. This taper allows for tape and joint treatment to be applied and the completed job will be flat, smooth and monolithic. BEVELED EDGE: r^-rr-n The beveled edge is a suitable edge to give a paneled effect After fasteners are covered with a compound the board Is ready for paint with grooves exposed. TAPERED w/ROUND EDGE: ^ Georgia-Pacific round edge (RE) gypsum wallboard can be used for wail and ceilings In both new construction and remodeling. It Is designed to reduce the beading and ridg ing problems commonly associated with standard type wallboard. This edge forma tion provides a stronger, more rigid joint and results in a smoother wall surface. "V" GROOVED EDGE: v s* Georgie-Pacifle'a "V' groove edge (some times referred to as the "tongue and groove" edge) was developed especially tor sheath ing and backer boards, to block moisture (sheathing) or fire (backer board). SQUARE EDGE: * --*; - MODIFIED BEVELED EDGE fr ' - L-. . -3 The gypsum wallboard square edge was the original wallboard edge. Initially designed to be a base with a final covering such as wallpaper, paneling, or tile, square edge can be finished with joint compounds to form a clean monothic wall suitable for paint Also can be used where an exposed joint la ac ceptable. The modified beveled edge is available only on Etemawall panels. This particular edge more readily accommodates the vinyl sur face decoration, which is delivered com pletely edge wrapped. The vinyt surface material Is available in 15 patterns and colors. JOINT SYSTEM PRODUCTS G-P Joint System products are designed to conceal joints and nail heads and "surface-weld" wallboard panels togather. Properly used, these products assure smooth, seam- G-P BEDDING COMPOUND . ^ Bedding Compound is designed to provide maximum ad hesion of tape to the joints and for initial application to nail heads and comer bead. It spreads smoothly and may be G-P^TOPPINGrCOM POUND G-P Topping Compound is specifically designed for the second and third coats over the bedding compound. Since it is used only for topping, we are able to reduce the amount of adhesive and incorporate other materials which reduce less appearance of walls and ceilings, with joints as strong as the wallboard Itself, - ; hand or machine applied. Coverage: 15 lbs. per 1,000 sq. ft (Used in conjunction with 45 lbs. of Topping Compound.) 25 lb. bags. the shrinkage and make it easier to sand and work. Coverage is approximately 45 lbs. per 1,000 square feet. Available in 25 and 50 lb. bags, SGP 0023086 E/5 G-P TRIPLE DUTYTM JOINT COMPOUND G-P Triple Duty Wallboard Joint Compound Is a vinyl multi purpose* joint system product. A single bag offers taping, topping and texturing. It can be used for all coats in the re inforcing and concealing of joints in gypsum wallboard con struction. The binder in Triple Duty, being a vinyl, gives this product a wet life of 30 to 60 days duration. This allows pre mixing in large quantities prior to application. Triple Duty can be applied using standard hand or mechanical tools. There is low shrinkage and it is easily sanded. When the application is completed, the surface is ready for priming and decoration as desired with no further preparation neces sary. Coverage: 60 lbs. per 1,000 sq. ft. (12-50 lbs. per 1,000 sq. ft. when used as a texturing material.) 25 and 50 lb. bags. G-P READY MIX JOINT COMPOUND Ready Mix Joint Compound Is an easy-working material for embedding the joint reinforcing tape and the filling and fin ishing of joints in gypsum wallboard construction. Furnished in cans and cartons ready to use, this stable, all-purpose compound is also excellent for use in covering nail heads and forming interior and exterior angles. Ready Mix Joint Compound assures a standard mixture for uniform worka bility throughout the job. It has a long wet life and will not spoil even when the container is left open. Ready Mix Joint Compound produces an excellent surface for any type of decoration. For best results, the surface should be primed before being decorated. Coverage: 5 gal. per 1,000 sq. ft. Package--1 and 5 gal. cans, 4 gal. cartons. G-P ALL PURPOSE JOINT COMPOUND G-P All Purpose Joint Compound is used for bedding tape, topping, comer bead, nail spotting and texturing. When taping be sure the compound under the tape, and the first coat over the tape is thoroughly dry before applying the next coat over the joints. When used for texturing, for best re sults, apply a vinyl primer to the entire area before texturing. The texture may be applied with a roller, sponge, brush or sprayed, depending on the type of configuration desired. Coverage: 60 lbs. per 1,000 sq. ft. 25 lb. bag and packaged 18 lbs. of compound plus 250' roll of tape. G-P SPEED SETTM G-P Speed Set Joint Compound makes possible the taping and finishing of all wallboard joints within a single day. It can be used for all coats. Speed Set is a setting rather than a drying type of compound, and will not shrink. Comes in two ways--"1 Hour Working Time" and "2 Hour Working Time". For best results, use a primer sealer over surface before painting or texturing. 25 lb. bags. G-P LAMINATING COMPOUND G-P Laminating Compound is an exclusive product formu lated to assure adhesion between sheets of wallboard. it is a casein base dry powder product, requiring addition of water only. Easy to mix and easy to apply, it forms a perma .-I*/*-,* ^ nent, positive bond. G-P Laminating Compound has been proven effective through many years of actual field use. Coverage: Approx. 35 lbs. per 1,000 sq. ft. 25 Lb. Package CEILING & WALL TEXTURES G-P Wall texture is an unaggregated texture compound for hand tool or spray application. When applied with a spray, a splatter or orange peel texture is formed. When applied by hand, a stipple, swirl, or brocade texture can be produced. G-P Wall texture can be applied immediately after G-P Ceil ing overspray wipedown. It is made for fast, volume applica tion. Because of its formulation, G-P Wall texture matches G-P Ceiling textures, without overlap discoloration. G-P Ceiling textures are designed for spray application over ceilings constructed with gypsum wallboard or concrete. The resulting texture simulates acoustical texture finish. Especially designed for volume operations, these products give unsurpassed economy. The texture dries harder and tighter. The texture maintains a high quality white decora tive finish. This texture gives exceptional coverage if used as instructed. Coverage: 12-50 lbs. per 1,000 sq. ft. depend ing upon texture. 25 Lb. Package wall, 40 Lb. ceiling. G-PaGRABITTM v ' 'v1 ~ ' G-P Grabit is an adhesive which permits direct attachment of gypsum wallboard to masonry walls. It may be used on poured concrete, cinder block or concrete block walls which are reasonably straight and true and are free from surface treatment, decorations, or protrusions. Grabit may be used on exterior walls which are above grade level with out waterproofing. Grabit can be used to adhere gypsum wallboard to polystyrene insulation material. Adhesion Is secure and permanent, with no need for furring strips or fasteners. After being mixed with water as directed, G-PjWALLBOARDTAPE G-P Tape is a full 2' width, "Miracle Crease" spark perforated tape with skived edges and sanded surface both Grabit can be applied with blade or caulking gun. Only four 1' ribbons are needed for each 4' wide wallboard panel. The adhesive fills in all normal irregularities in the masonry. In 3 to 4 hours, Grabit sets hard, and join taping and finishing operations may then be started. This adhesive may be used wherever there is need to attach gypsum wallboard to ma sonry wails: in homes, apartments, hotels, offices, and plants. Coverage: Up to Vi lb. per sq. ft depending on roughness of base surface. 50 Lb. Package. I) sides. Excellent bonding qualities. Stabilized against shrink* age and movement. E/6 SGP 0023087 TEcnmibHb um>n nn*v................... ......... AATtM !r'T33 .jskm3L rttnrurL nc 1 TUT urn. iCmOaT / ; THSHOICtTKl.- WAIIMSOMT SC. FT. WOOD PARTITIONS (2" x 4 " Studs---16" O.C.) wAusumcs 25 min. EST 31 EST 90 4H' 51 ft" G-P Gypsum Wallboard Both Sides i 40 min. EST - BS-234 ; 100 4*" 5.9 ft" G-P Gypsum Wallboard Both Sides rsi UCAMMR! mx # OCTAfl fmArMa _ Vr?:'-- ABC t ABC - - 45 min. U.L 1 32 EST 110 4ft" 5.9 ft" G-P Firestop Both Sides BC - - lhr. U. 501 34 QR-64-8 115 4ft" 7.0 ft" G-P Firestop Both Sides (U.L 5) 1 hr. U. 501 34 OR-64-8 125 4ft" 7.0 ft" G-P Firestop Tile-Backer Board (U.L 5) Both Sides lhr. GA - BS-225 135 5ft" 8.2 ft" G-P Gypsum Wallboard, 2 layers. Both Sides 1% hr. EST 37 CR-64-11 135 5ft" 9.5 ft" G-P Firestop, 1 Layer, One Side, 2 Layers Other Side 1% hr. G.A. 39 NBS 140 5*" 9.9 ft" G-P Gypsum Wallboard, 2 Layers, Both Sides ABC - - ; ABC - - A-- --- A-- 2hrs. T-194 41 OR-64-12 180 6ft" 12.0 ft" G-P Firestop, 2 Layers, Both Sides WOOD PARTITIONS (2" x 4 lhr. U. 312 45 8W-27-FT (U.L 30) lhr. U. 312 47 BW-28-ST (U.L 30) lhr. EST 47 8W-29-ST lhr. U. 312 50 (U.L 30) BW-35 lhr. EST 50 BW-31ST lhr. EST 52 BW-30-ST lhr. EST 55 BW-32-ST 16"^O.C. with Vi "-Gypsum Sound Deadening Board) '***. 145 5ft" 7.96 ft" G-P Firestop, 1 Layer Strip Laminated Over ft" Gypsum Sound Oeadening Board, 2 Sides 160 5ft" 175 7ft" 175 5*" 225 ioy" 160 7ft" 240 ioyr ! 8.3 ft" G-P Firestop, 1 Layer Laminated over ft" Gypsum Sound Deadening Board, Both Sides ft" G-P Firestop, 1 Layer Over ft" Sound 8.79 Deadening Board, Both Sides Laminated, Staggered Studs 8.7 ft" G-P Firestop Type X, 1 Layer Strip Laminated over ft" Gypsum Sound Deadening Board, 2 Sides, 1ft" insulation ft" G-P Firestop, 1 Layer Laminated over 9.14 ft" Gypsum Sound Deadening Board, Both Sides double studs ft" G-P Firestop, 1 Layer over ft" 8.92 Gypsum Sound Deadening Board, 2 Sides, Ift" insulation ft" G-P Firestop, 1 Layer Laminated over 9.29 ft" Gypsum Sound Deadening Board, 2 Sides, 1ft" insulation, double studs ABC 110 E/15 ABC 100 E/14 ABC 102 E/14 ABC 104 E/14 ABC 106 E/14 ABC 108 E/14 ABC ABC - E/7 SGP 0023088 UTIM JSSKbIL iSa. 116 uTrOeTa. - rtaenn WOOD STUDS/Resilient Channels nPnUcTa.Hin 1 hr. T-3127 44 OR-64-7 . 135 5K" WIIMT AM U. FT. wer> imm IIBJHUJA..IJJUI. WAUStMTACt 6.3 H " G-P firestop, 1 Layer Nailed 1 Side, 1 Layer on Resilient furring other side l%hr- EST 43 OR-64-15 155 8.8 ft" G-P firestop, 2 Layer 1 Side, 1 Layer on Resilient furring other side WOOD STUDS/Resilient Channels/lnsulating Blankets ft" G-P Firestop. 1 Layer Nailed 1 Side, lhr. T-3127 50 OR-64-16 150 5ft" 6.4 I Layer on Resilient tuning other side, plus fiberglass insulation in stud space WOOD STUDS/lnsulating Blankets lhr. BMS-92 39 EST 110 4ft" 6.0 ft" G-P Gypsum Wallboard, Both Sides with Mineral Wool in Stud Space STAGGERED STUD WALLS 1ft hr. - 43 OR-OO-O 175 7ft" 11.0 ft" G-P Regular, 2 layers, Both Sides eMi mr. KTia INTO # PMt ABC 112 E/15 114 E/15 ABC 116 E/15 - 2 hr* U.L 47 II-69-2I0 190 8ft" 12.7 ft" G-P firestop, 2 layers, Both Sides - - - Based on lhr. U. 501 48 (U.L 5) EST 140 6ft" 7.0 ft " Firestop. 1 layer each side, 2x6 plate, ift" insulation DOUBLE WOOD STUDS ft" firestop, 1 layer each side double row lhr. EST 50 EST 215 9ft" 7.5 of studs r apart on separate 2x4 plates, insulation in stud space WOOD*STUDS/Fiber Sound Board lhr. T-3006 46 0R-64-73 165 - - r-v-.u' 1 5ft" 8.5 ft" G-P firestop, 1 layer over ft" fiber Sound Oeadening Board Both Sides ABC - - |. ABC 118 E/15 EXTERIOR-WALLS lhr. T-99 BMS- 191-192 2hrs. U.L23 -<-> 5%' ft" G-P Firestop, interior 1 layer ft" Gypsum Sheathing and Plywood or Wood Siding-Exterior ft" G-P firestop, 2 layers interior, ft" Gypsum Sheathing, T x 8" TAG Brick Wall Exterior ABC ABC Many of these ere new numbers assigned by Underwriters' Laboratories (old numbers are in parentheses). COST INOEX BASIS: For wood and gypsum partitions, 100 is for 2x4 studs, 16' o.c.. Vi" Regular wallboard each side. For metal stud partitions. 100 is for 2 >4' studs. 24' o.c., H" Firestop each side. Other assemblies are rated against those two. Allowances should be made for the fact each location may have differing labor and material cost conditions. E/8 NOTE: This table is a summary only, based on tests at Underwriters' Lab., National Bureau of Standards, Univ. of Calif., Ohio State Univ., Geiger and Hammes, Riverbank Lab. and/or Ohio Research Corp. sponsored by the G-P Gypsum Division. Gypsum Association, or others. Fire rating, weight, and sound characteristics are based on a combination of specific details as tested and published. Where carpet and pad is used in sound tests, carpet is 44 oz. and pad 40 or weights. * 4 SGP 0023089 dI*sJ8 I UTIM uTnOTi. ne TOT uni. iCnOnT TPNMUUCTSa.- WJOMI1.SOFKTT. WAUL SURNkCt [ SEMI-SOLID GYPSUM PARTITIONS (Non-loadbearing 1" x 6"--2%" x 3"--%" x 6") - 1 1 KcuaMsre. mwr. * Si oINmTOs rue 1 hr. U.L 10 35 8W-8-FT 75 244" 7.2 1 hr. EST 51 OR-65-19 125 444" 72 44" G-P Firestop, 1 layer each side, height limit 12 ft based on 1/120,5 lbs. PSF ABC t %" G-P Firestop, 1 layer 1 side, other side screwed to resilient channels plus 2" fiberglass instil, in stud space - 1 hr. T-3128 51 0R-64-57 150 444" 7.9 44" G-P Firestop, 1 layer over 44" G-P S.D. board AB both sides ' SOLID GYPSUMBOARD PARTITIONS (Non-loadbearing) < - v-aSST - - 2 hrs. EST 36 GA 100 244" 9.1 44 " G-P Firestop, 1" Layer Each Side, 1" Coreboard 2 hrs. GA 37 GA 95 r 2 ha GA 39 GA 90 r 44" G-PGypsumboard, 1 Layer Each Side, 8.1 1" Coreboard, height limit 9 ft based on L/120, 5 lbs. PSF 44" G-P Firestop, 1 Layer Each Side, 8.1 r Coreboard, height limit 9 ft based on L/120, 5 lbs. PSF DOUBLE SOLID GYPSUMBOARD PARTITIONS (Non-loadbearing) >. ; - V^r---=' - 1% hr. U.L - 0R-64-39 - 6" 9.5 44" G-P Gypsumboard over H" G-P Firestop Each Side, 1" Coreboard ;- ABC -- --- - -- 3 ha U.L 5 - TR-57-43 - 5" 13.4 44" G-P Firestop, 2 Layers Each Side, 1" Rib Coreboard ABC - - 2 ha U.L 7 35 TR-57-42 - 4" 13.4 G-P Firestop, 2 Layers Each Side, 1" Rib Coreboard ABC - - 2 ha T-2575 47 0R-64-39 - 6" 13 G-P Gypsumboard over 1" Coreboard Each Side of 3" air space ABC 200 E/16 TRIPLE'SOUDtGYPSUMBOARD PARTITIONS 4 3 ha EST 51 OR-64-58 - 6" 17 44" G-PGypsumboard, 1 Layer over 1" Coreboard both side of 3" air space with 1" Coreboard 44" G-P Gypsumboard, 1 Layer over 1" Coreb'd. Each 3 ha EST 58 OR-64-59 - 6" 172 side of 3" air space with 1" Coreb'd centered in air space and fiberglass insulation in space on 1 side. TRIPLE SOLIO GYPSUMBOARD PARTITIONS (Non-loadbearing) 2 ha T-4958 - - - 244" 10.5 G-P 144" core unit plus two face layer 44" G-P regular screw-laminated, track and vertical T' splines 2 ha Chase T-4991 Wall - 144 hr. T-4982 - - - rr 9.0 - ivc 8.4 G-P 144" core unit, angle runnea 244" metal studs, one facing layer of 44" Firestop screwed to studs G-P 144" core unit, plus face layer 44" Firestop screw-laminated. Track and vertical "V splines on 24" centers - - 202 E/16 sm\ --- - ii - - -i * E/` SGP 0023090 1 hr. ESI 41 OR-66-5 110 3r 4.3 ft" G-P Firestop, 1 layer each side, 2" fiber glass instil, in stud space, 2ft" studs - K) 1 1 hr. - 44 OR-64-81 115 0.0 1 hr. - T-4848 48 OR-66-6 125 5%' 7.0 1% hr. EST 48 0R-64-80 145 3X* 7.2 Hw G-P Firestop, plus 1%" fiber glass instil, in stud space, 1ft" studs ft" G-P Firestop, 1 layer 1 side, ft" regular G-P gypsumboard, 2 layers other side (insulation in cavity for STC), 3%" studs ft " G-P Firestop, 1 layer 1 side, 2 layers other side 1%" fiber glass insui. in stud space, \ft" studs ; 300 E/16 316 E/18 -- 1% hr. EST 48 OR-66-6 130 4" 6.3 2 hrs. T-3218 48 BW-12-R 155 4tf" 8.0 ft" G-P Rrestop, 1 layer 1 side. 2 layers other side plus 2" fiber glass insui. in stud space, 2ft" studs ) -- ft" G-P Firestop, 2 layers each side, STC based on L 310 E/17 2" insui. in stud space, 2ft" studs 1% hr. T-3126 SO OR-64-51 150 5ft" 8.0 ft" G-P Firestop, 1 layer 1 side, 2 layer other side AB 318 E/18 plus 3" fiber glass insui. in stud space, 3ft" studs 2 hrs. T-2557 52 0R-64-50 170 6H' 11.1 ft" G-P Firestop, 2 layers both sides pluslH" fiberglass in stud space, 3ft "studs i _ 324 E/18 METALiSTUDS/GYPSUMlSOUND DEADENING.BOARD Sfifc; 1 hr. U410 45 BW-16-FT 130 4" 7.0 ft" G-P Firestop, 1 layer, laminated over ft" S.D. (U.L 32) board, both sides screw attached, 2ft" studs 1 hr. U410 (U.L 32) 50 BW-17-R 140 4" 7.12 ft" G-P Firestop, both sides 1 layer, laminated to S.D. board, screw attached, 2" fiber glass friction fit in stud space, 1ft" studs 1 hr. U410 (U.L 32) 54 BW-18-R 145 4tr 8.12 ft" G-P Firestop, both sides, 1 layer laminated to ft" S.0. board screw attached, 2" fiber glass friction fit in stud space, 2ft" studs ______________ METALSSTUDS/FIBERBOARDISOUND DEADENINGBOARD ABC 304 E/16 ABC 306 E/17 ABC 308 E/17 EB ISl 1 hr. EST 44 OR-65-10 125 5H" 5.75 ft" G-P Firestop, 1 layer 1 side, other side, 1 layer over ft" fiber S.0. board, 3%" studs - 320 E/W| 1 hr. EST 49 OR-65-11 135 - ft" G-P Firestop, 1 layer over ft" fiber S.D. board, both sides 3%" studs -- - FIRE HAZARD CLASSIFICATION: Official UndwwriUrs' Tests. Vi' *nd %' 6-P Firestop, 10-15 (labeled); yh". and H" G-P. 10-15 (Not Labeled). Mora complete listings and details are available. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. 1. STC under sound characteristics is Sound Transmission Class. 2. Official Underwriters' Tests have proven joint finishing is not required for the rating in assemblies of Firestop. E/10 3. Under "Model Building Code Approvals" (A) refers to International Confer ence of Building Officials: (B) refers to Southern Building Code Congress (C) refers to Building Officials Conference of America. Additional approval requested. NOTE: All systems are ranked by S.T.C. number in each category. SGP 0023091 p UTIM 1 TOT E tuu. TUT nia MMX 1 METAL STUD PARTITIONS 35 min. EST 35 OR-65-2 90 TnuKuninau. WitMtrIMMrT. w- wiumenci : ft" G-P Gypsumboard, 1 layer each side, 2ft" studs 1 BcmUooMt. mMr. MimT1II MU -< 1 hr. T-2316 35 Tl-62-72 95 2ft" 52 ft* G-P Hrestop, 1 layer each side, 1ft" studs ABC 302 E/16 1 hr. T-2898 35 OR-64-65 130 3ft" - ft" G-P Firestop, Etemawall, 1 layer each side, 2ft" studs AB - - lhr. T-2069 39 0R-63-1 100 3ft" - ft" G-P Firestop, 1 layer each side, 2ft" studs A -- lhr. T-2016 42 OR-63-11 105 4ft" 1% hr. EST 43 OR-63-2 135 4ft" 6.0 7.5 1ft hr. EST 43 OR-64-32 140 5ft" 8.0 2 hr. T-2557 46 EST 150 5" 10.4 ft" G-P Firestop, 1 layer each side, 3ft* studs ABC - - ft" G-P Firestop, 1 layer 1 side, 2 layers other side, 2ft" studs ft" G-P Firestop, 1 layer 1 side, 2 layers other side, 3ft" studs -312 E/17 ft " G-P Firestop, 2 layers, 2 sides, 2% " studs AB 314 E/17 2 hr. T-2557 47 OR-64-52 6ft" 11.0 ft" G-P Firestop, 2 layers, 2 sides, 3ft" studs - 322 E/18 2 hr. T-2406 47 EST - 6ft" 10.4 ft " G-P Firestop, 2 layers, 2 sides (face layer-- Etemawall), 3ft" studs ABC - STEEUSTUD CHASE.WAL1/(1 %'SMelal Studs 24" o.c.:-^6" x.12"--%'%Gypsumhoard Spacers) i--- I lhr. EST 47 BW-335T 7ft" 6.69 ft" G-P Firestop, 1 layer laminated over ft" S.D. board, both sides A 326 E/18 lhr. EST 52 BW-345T - 7ft" 6.84 STEEL^COLUMNiFIREPROOFING - lhr. lhr. 1ft hr. 2 hr. 2 hr. 3 hr. 3 hr. 4 hr. GA EST GA X520 (U.L20) X517 (U.L8) X513 (U.L 39) X509 (U.L 18) X501 (U.L 26) _ - - -- - -- - -- -- -- -- _ -- -- -- -- -- - -- -- -- - -- -- -- ft " G-P Firestop, 1 layer laminated over ft " S.D. board both sides, plus 1ft" insul. in stud space ft" G-P Gypsumboard, 2 layers ft" G-P Firestop, 1 layer ft" G-P Gypsumboard, 3 layers ft" G-P Firestop, 1 layer A 326 E/18 3fev* _---- AB - -------- ft" G-P Firestop, 2 layers ABC ft" G-P Firestop, 2 layers * ft" G-P Firestop, 3 layers ABC ft" G-P Firestop, 4 layers AB ** E/ll SGP 0023092 TECHNICAL DATA floor/ceiling construction SOUND CONTROL & FIRE RESISTANCE Technical Data'-:- r WilMT SttJM UTIM isjm. rr. I utim TUT Hr. nu UMSTMCI UTIM TUT W.' WOOD JOISTS 16" o.c. finished floor on rough sub-floor, except as noted. H* G-P Regular, 1 layer V4' G-P Regular, 1 layer 14' G-P Firestop, 1 layer H' G-P Fimtop, 1 layer H' G-P Fimtop, 1 layer nailed; 2nd layer 44' Fimtop applied to miliefit furring channel 24' ox. between layers H' G-P Fimtop, 1 layer nailed 14' G-P Fimtop applied to resilient metal furring 24' ox. 44' G-P Regular, 2 layers 14' G-P Regular, 2 layers 14' G-P Fimtop, 1 layer, laminated and nailed to 14' G-P Gypsum Sound Deadening Board, with floor of 44' CD plywood, 14' partideboard underlayment, carpet and pad H' G-P Firestop, 1 layer laminated and nailed to 14' G-P Gypsum Sound Deadening Board with floor of 44' CD plywood, 14' partideboard underlayment, carpet and pad 44' G-P Firestop, 3' insulation, resilient furring, carpet and pad 11.4 11.4 12.0 16.0 13.0 13.0 -- -- -- -- -- -- -- STC, 38, INI8--16 (Est) ' c-- fc ^ 1-- -- . STC 47 t, TLS+155 -- -- STC 41/ ; INR + 25 BW-2MT STC 42/ NNR + 25 f- STC 48/ INR + 18 (Est) 1-224* 364 15 mill. 25 mill. 45mm. 1 hr. 2 hr. 1 hr. lhr. 30mhi. lhr. lhr. lhr. lhr. PREFABRICATED FLOOR PANELS spaced 12" o.c.--Combustible wmm mm Ul. No. 1 1501 (Ul. No. 1) 1505 (Ul. No. 217) 150300. No. 46) L502 (Ul. No. 33) Est Est Est Est Est MODCL SUIIXIM C00I ABC ABC AB AB ABC ABC ABC ABC ABC _ v-s, ... 14' G-P Firestop. one layer over 14' sound deadening board (direct attached) 6.5 I 1 hr. I Ul. No. 47 I 2"-CONCRETE FLOOR ON METAL LATH over Steel Bar Joists 24" o.c --Incombustible * I 44' G-P Firestop nailed or screwed to metal furring 16' o.c. 44' G-P Firestop Backer, nailed or screwed to metal furring 16' ox. 44' G-P Firestop, 1 layer, metal furring 24' ox. 14* G-P Firestop, metal furring 24'o.& 44' G-P Firestop, metal furring24'ox. H' G-P Firestop metal deck 44' G-P Firestop, nailed, 144' lightweight concrete, 44' plywood, wood joists 16' o.c. insulation, resilient furring, carpet and pad 44' G-P Firestop, nailed, 1H' lightweight concrete, 14' plywood, wood joists 16' o.c., insulation, carpet and pad________________________ 34.2 34.2 32.0 33.9 36.4 -- -- -- --* -- L^ ---- ---- - ( STC53/ > INR + 23 ; STC 47/ INR+ 15 -- ---- ---- ---- -- 1-224* 27628 L-224* 29630 11 hhrr.. llhhrr.. lhr. 1)H4 hr. 2 hr. 2 hr. 1 hr. lhr. UUll..NNoo..22 UUll..NNoo..22 GS01 (Ul. No. 19) G5S02 ((UUJl_. No. 17) GS05 (U.L. No. 259) Ul. File R4024-12 Est Est ABC ABC ABC ABC IVz "^CONCRETE FLOOR ON METAL LATH over Steel Bar Joists, 24">o.c^-lncombustible 14' G-P Firestop, metal furring 24' ox. 44' G-P Firestop, metal furring 24' o.c. STEEL-WOOD COMBINATION JOISTS 38.5 rr 39.3 ^- 44' G-P Firestop, 18' deep combination steel-wood joists 32' ox, 3* insulation, resilient furring, carpet and pad, 114' plywood sub-floor 44' G-P Firestop, 18' deep combination steel-wood joists 16' ox.. 3' insulation, H' plywood, lightweight concrete deck, carpet and pad BEAM PROTECTION STC 47/ INR +18 STC 46/ INR + 11 L-22435 & 36 L-224* 37 6 38 V G-P Firestop, turn layers \- - `Many of these are new numbers assigned by Underwriters' Laboratories. (Old'numbers are in parenthesis) SOUNO CHARACTERISTICS--References: Geiger and Harnma, Inc.; Riverbank Labs; Koderas. (A) UNDER MOOEL BUILDING COOE APPROVALS. A--Refers to international Conference of Building Officials. B--Refers to Southern Building Code Congress. C--Refers to Building Officials Conference of Amaria. Additional Approvals Requested. FIRE HAZARO CLASSIFICATION: Official Underwriters' Tests. 14' and %' G-P Firestop, 10-15 (Labeled); 14'. 14', and H' G-P, 10-15 (Not labeled). More complete listings and details are available. Inconsistencies in test results are due to tests over a period of many years and variations in laboratory facilities. 1. STC under sound characteristics is Sound Transmission Class. 2. Official Underwriters' Tests have proven joint finishing is not required for the rating in assemblies of Firestop. 3. Under "Model Building Code Approvals" (A) refers to International Conference of Building Officials; (B) refers to Southern Building Code Congress; (0 refers to Building Officials Conference of Ameria. Additional approvals requested. NOTE 1. This table is a summary only, based on tests at Underwriters' Laboratories, National Bureau of Standards, University of California, Ohio State University, sponsored by the Georgia-Pacific Gypsum Division, Gypsum Association, or others. The fire rating, weights and sound characteristics are based on a combination of specific details as tested and published. NOTE 2. Combustible Assemblies--For all 45 minute and 1 hour ratings 44" structural interior plywood underlayment grade, over building paper, over xh" structural interior plywood with exterior glue C-D grade may be used over the wood joists with ceilings as detailed. NOTE 3. Incombustible Assemblies--Ceilings for all 1 hour, 1% hour and 2 hour incombustible floor and ceiling construction assemblies with 2" or 2V4" concrete floor on metal lath over steel bar joints, unless otherwise specified, may be directly attached or suspended. G-P Firestop is listed by Underwriters and carries the UL Label for 45 minutes, 1, 2 and 3 hour Fire Resistance in various designs and with a Fire Heard Classification of 10-15. E/12 SGP 0023093 jfcpk SPECIFICATION UiKCb i Uh i GYPSUM DUAnu rnuuuwia PfOOUCT G-P REGULAR WALLBOARD Tapered Edge Square, Tapered or Round Edge G-P INSULATING WALLBOARD Square, Tapered Edge or Round Edge rNaOceS- WIPTM i 94' r 94" %* r : 94' 4' 4' 4' 4' 4' 4' 4' G-P ETERNAWALLTM Modified Beveled Edge 94' 4' %" 4' G-P FIRESTOP* WALLBOARD Square, Tapered Edge or Round Edge 94m 94' G-P FIRESTOP* INSULATING WALLBOARD Square, Tapered Edge or Round Edge r 94' G-P TILE BACKER BOARD Tapered Edge 94' 94' G-P GYPSUM SOUND DEADENING BOARD Square Edge 94' G-P BACKER BOARD Square or T & G Edge 94' 94' 94' G-P FIRESTOP* GYPSUM SHEATHING Long edges Square Edge Core-treated or non core-treated Tongue and Groove Core-treated or non core-treated tStandard Ltftett--Otter Lngtta M Otter. 94' r 94' 4' 4' 4' 4' 4' 4' 4' 4' r r 4' r G-P G-P WOOPCT JOINT SYSTEM MATERIALS METRO-MIXTM G-P FORM BOARD UNBTN asm sTMune 6'to 12* 6'to 16' 6'to 16' 6'to 16' | C 35-61 6'to 16' 6'to 16' 6'to 16' | C 36-68 SKncairctncua.iim aUmNiHcet SS-L-30C Type Ill-Grade R 3/20/67 ANSI A97.1 SS-L-30c Type Ill-Grade R 3/20/67 ANSI A97.1 8't C 36-68 8't 6'to 16' | C 36-68 6'to 16' 6'to 16' | C 36-68 6'to 16' 8', 11' and 12' C630-70 SS-L-30C Type Ill-Grade R or Grade X Class III 3/20/67 SS-L-30C Type Ill-Grade X 3/20/67 SS-L-30C Type Ill-Grade X 3/20/67 ANSI A97.1 ANSI A97.1 ANSI A97.1 - 8' C442-67 SS-L-30C Type IV--Grade R - 8'Std-t 8'Std.t 8'Std.f | C 442-67 l f SS-L-30C Type IV Grade R Grade X - 8'4 9' 8'Std.t C 79-67 ) SS-L-30C > Type II C 79-67 l Grade R4W - asm namams C 475-64 C 317-64 C 318-67 rtIoMnGa.a SS-J-570a 10/24/66 -- TypeV SS-L-30C Grade R aUmNSicUe ANSI A97.1 ANSI A59.1 ANSI A59.1 Any questions not answered by the information on this sheet or available from local sources should be referred to the General Sales Office. Be sure to give all information as to issuing office, date of specification, job description, location, enforcing party, product involved, description of use if other than normal, amount involved, etc. This is particularly important when special limitations under standard specifications are involved. Gypsum Division field locations have a book of applicable Federal and ASTM Specifications. Each Specification is preceded with a detailed analysis pre pared by the Laboratory of which G-P products meet the specification and any limitations. The Local Sales Office is authorized to write a letter of certification in accordance with the Laboratory analysis. E/13 SGP 0023094 SYSTEM INSTALLATION DETAILS Vj'YG-P FIRESTOP'S LAMINATED TO !4 "'GYPSUM SOUND DEADENING BOARD STC/45 G4HBW27FT FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST U.L U312 (U.L 30) Materials Used 1. 2" x *>" Wood Studs 2. 2* x 4' Wood Plates XV*' Gypsum Sound Deadening 8oard 4. 'h ' Flrestop Typo XXX Wallboard or Flrestop EternawallTM 8. 5d cc Nalls 8. 4d Finish 7. G-P Joint Compound ' x10Q Vfc'tfG-P-FIRESTOPM-AMINATED TO Va" GYPSUM SOUND DEADENING BOARD STC/47 G&H BW 28FT FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST U.L U312 (U.L 30) Materials Usad 1. 2' x 4' Wood Studs 2. 2* x 4' Wood Plates 3. V* ' Gypsum Sound Deadening Board 4. H ' Firostop Type X Wallboard or Flrestop EternswallTM 5. Joint Compound 8. 4d Finishing Nails 7. 5d Nalls -H ^ ^^102 -Vi'YG-P-FIRESTOPNLAMINATED TO '/a-AGYPSUM SOUND.DEADENING BOARD -- . ? .-.-.r- STC/47 G&H BW 29ST STC/52 WITH INSULATION G&H BW 30ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2* x 4' Wood Studs (staggered) 2. 2' x 6' Plata 3. V*' G-P Gypsum Sound Deadening Board 4. Vi" G-P Flrestop Type XXX or Flrestop EternawallTM 5. G-P Joint Compound X 4d Finishing Nails and 4d Common Nails 7. 5d Common Nails 8. 1 Vt' Fiberglass Batts (on BW-30ST for STC/52) %^:p?IRESTOP**rYPE X/S1H-AYER LAMINATED TO Va'iiS.D.B.?2 SIDES WITH1 Vi**INSULATION STC/50 G&H BW 35FT FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST U.L U312 (U.L 30) Materials Used 1. 2" x 4' Wood Studs 2. 2' x 4' Wood Plates XV*' Gypsum Sound Oeadenlng Board 4. %" Firestop Type X Wallboard or Firestop EtemawailTM 5. Joint Compound 3. 4d Finishing Nails .7. 5d Nails 8 1W' Fiberglass Batts. t$Vi^8G?PFIRESTOP^t!AMINATEDTO'%"4GYPSUM SOUND'DEADENING BOARD STC/50 G&H BW 31 ST STC/55 WITH INSULATION G&H pW 32ST FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2' x 4" Wood Studs (double row) 2. 2' x 4" Wood Plates--1 * apart X V* ' G-P Gypsum Sound Deadening Board 4. Vi" G-P Firestop Type XXX or Firestop EtemawallTM S. 4d Finishing Nails, 4d Nalls 8. 5d Nails 7. G-P Joint Compound 8. 1V4 " Fiberglass Batts (on BW 32ST with insulation for STC/55) E/14 SGP 0023095 G-P FIRESTOP\ 2 LAYER 2 SIDES STC/41 SOUND TEST OR 64-12 FIRE RATINQ/2 HR. COMBUSTIBLE/FIRE TEST T-194 Materials UMd 1. 2' x 4' Wood Studs 2. 2" x 4' Wood Plstm X H ' Ffrestop Typo X Gypsum Wallboard 4. 1V4 ' Type W Drywail Screws X Joint or Laminating Compound G-P FIRESTOPMJN RESILIENT CHANNEL STC/44 SOUND TEST OR 64-7 FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST T-3127 Materials Used 1. 2' x 4' Wood Studs 2. 2* x 4" Wood Plates X H * FI restop Type X Qypsum Wallboard 4. Oonn DG-d Resilient Channels X 1Y* ' Type W Drywail Screws X 1* Type S Drywail Screws %'i*G-P FIRESTOP*?2 LAYERS 1 SIDE/1-LAYER ON RESILIENT CHANNEL-MOTHER SIDE STC/48 SOUND TEST OR 64-1S FIRE RATING/1 Yx HR. COMBUSTIBLE/EST. Mstertals Used 1. 2" x 4* Wood Studs 2. 2'x 4'Wood Plates X % * FIrestop Type X Gypsum Wallboard X Donn OG-8 Resilient Channels X 1Y* * Type W Orywall Screws X 1'TypeS Orywall Screws %"*G-P FIRESTOP^ON RESILIENT CHANNELWITH INSULATION IN CAVITY STC/50 SOUND TEST OR 64-16 FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST T-3127 Mstertals Used 1. 2* x 4* Wood Studs X 2* x 4* Wood Plates X H" Flrestop Type X Qypsum Wallboard 4. IV Fiberglass Insulation X Donn DG-8 Resilient Channels X 1 V ' Type W Drywail Screws 7. 1* Type S Orywall Scrsws %'tfGFP'5FIREST0P^40VERTFIBER'SOUND DEADENING BOARD 2 SIDES STC/46 SOUND TEST OR 64-73 FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST T-3006 Materials Used 1. 2" x 4' Wood Studs X 2' x 4' Wood Plates X 2" x 4' Wood Fire Blocks X Yt" Fiber Sound Deadening Board X %' Firestop Type X Qypsum Wallboard X 5d Cement Coated Nails and 8d Box Nails 7. Laminating or Joint Compound -^*114 E/15 SGP 0023096 1iypsum wallboard over coreboard 47 SOUND TEST OR 64-39 RATING/2 HR. COMBUSTIBLE/FIRE TEST T-2575 iliUnd 1 % * Wood Portmotor Framing ongue A Qroovo Coroboard Gypsum Wallboard nating Compound .alia D i I |GYPSUM WALLBOARD OVER COREBOARD WITH INSULATION IN CAVITY 57 SOUND TEST OR 64-89 RATING/3 HR. COMBUSTIBLE/EST. ala Used < 1H' Wood Strips r 24* Tonguo A Qroovo i board Gypsum Wallboard ' Fiberglass Insulation i nating or Joint Compound And 8d Nails * FIRESTOP"SULAYER EACH SIDE >*- -V r .***.-- 4 38 RATING/1 HR. NON-COMBUSTIBLE/FIRE TESTT-2316 ialsUsod i" Stool Studs, 24" o.c. i * Floor and Coiling Track Firestop Typo X Gypsum 'Iboard Typo "S" Drywall Screws ' ^>7^02 IRESTOP*EACH^IDEWlTH INSULATION IN CAVITY ^ - <- '44 ND TEST OR 64-61 : RATING/1 HR. NON-COMBUSTIBLE/FIRE TEST T-2316 ala Used i" Stool Studs, 24' o.c. i' Floor and Ceiling Track " Firestop Typo X Gypsum allboard 4. IVi' Fiberglass Insulation S. 1' Typo "S" Drywall Screws IrFIRESTOPPfOVERTW^GYPSUM SOUND DEADENING BOARD 45 SOUND TEST BW 16FT i RATING/1 HR. NON-COMBUSTIBLE i TEST T-3854 & U410 (U.L. 32) rials Usod i" Stool Studs, 24' o.c. i" Stool Channel " Gypsum Sound Deadening aard Typo "S" Drywall Screws 5. Vi' FirostopTM Typo XXX Wallboard or Firestop Etomawall^ A 1H" Type "S" Drywall Scraws i i SGP 0023097 %">G-P FIRESTOP OVER 'A- GYPSUM SOUND DEADENING BOARD WITH INSULATION IN CAVITY -306 STC/50 SOUND TEST BW17FT FIRE RATING/1 HR. NON-COMBUSTIBLE/FIRE TEST T-3S54 Materials Usad 1. 2Vi * Q-P Steal Studs, 24' o.c. 2. 2Vi * Q-P Steal Channals 3. 2' Friction Fit Fiberglass Insulation 4. Vi> * Q-P Qypsum Sound Daadening Board 5. 1* Q-P Typa "S" Drywall Screws X Vi ' Q-P FireatopTM Typa XXX Wallboard or Firsstop EtamawailTM 7. 1%' Q-P Typa "S" Drywall Screws %-VG-P FIRESTOP* OVER *A*PGYPSUM SOUND DEADENING BOARD WITH INSULATION IN CAVITY ^~308 STC/54 SOUND TEST BW 18FT FIRE RATING/1 HR. NON-COMBUSTIBLE/FIRE TEST T-3854 Materials Usad 1. 2Vi ' Q-P Steal Studs, 24' o.c. X 2Vi' Q-P Steal Channels 3. 2' Friction Fit Fiberglass Insulation 4. V* ' Q-P Gypsum Sound Deadening Board 5. 1' G-P Typa "S" Drywall Screws X H' Q-P Flrestop* Typa "X" Wallboard or Flrastop* Etemawail 7. 1%' Q-P Typa "S" Drywall Screws %"4G-P FIRESTOP**2.LAYERS 2 SIDES WITH INSULATION IN CAVITY vi-. --e--^ - ^ STC/48 SOUND TEST BW 12FT FIRE RATING/2 HR. NON-COMBUSTIBLE/FIRE TEST T-3218 (Fiberglass Insulation not rsquirsd for firs rating) Materials Usad 1. 2Vi' Steal Studs, 24' o.c. 2. 2Vi' Floor and Celling Tracks X Vi ' Flrestop* Typa XXX Qypsum Wallboard 4. 2' Fiberglass Insulation 3. Laminating or Joint Compound X 1'and 1%'Type S Drywall Screws ; Mr^310 %*SG-P FIRESTOP'*1 LAYER 1 SIDE, 2 LAYERS OTHER SIDE v STC/43 SOUND TEST OR 63-2 FIRE RATING/1 % HR. NON-COMBUST1BLE/EST. Materials Usad 1. 2Vi' Steal Studs. 24' o.c. 2. 2Vi " Floor and Ceiling Track X H' Firestop* Typa X Qypsum Wallboard X 1' and 1H " Typa S Drywall Screws %??G-P FIREST0P??2'i3LYERS 2 SIDES STC/48 FIRE RATING/2 HR. NON-COMBUSTIBLE/EST./FIRE TEST T-2557 Materials Usad 1. 2Vi" Steel Studs, 24' o.c. X 2Vi ' Floor & Ceiling Track X %' Firestop, 2 layers each side X 1' & 1 % " Type S Screws E/17 SGP 0023098 V^VG-P FIRESTOPM LAYER 1 SIDE. Vz" G-P REGULAR, 2 LAYERS OTHER SIDE STC/48 (EST) FIRE RATING/1 HR. NON-COMBUSTIBLE/FIRE TEST T-4848 Materials Used 1. 34*' StMl Stud*. 24' o.e. 2. 34* 'Track 3. V* ' Flrestop* Typo XXX Gypsum Wailboard 4. 14' Raguiar Gypsum Wailboard 5. 1W' Fiberglass Insulation (not rsquirsd tor firs rating) 8. 1* & 14*'Type S Screws - -316 %"<G-P FIRESTOP-/2 LAYERS 1 SIDE. 1 LAYER OTHER SIDE WITH INSULATION IN CAVITY STC/50 SOUND TEST OR 64-51 FIRE RATING/1 % HR. NON-COMBUSTIBLE/FIRE TEST T-3126 Matarials Uaad 1. 34* ' Steal Studs. 24' o.c. 2. 34*'Floor and Ceiling Track 2. 4* ' Flrestop* Typo X Gypsum Wailboard 4. 3* Fiberglass Insulation 5. Laminating Compound 6. 1' and 1%' TypoSOrywall Screws - J'*318 %'JG-P-FIRESTOP?.t41:LAYER I'SIDE.'I-LAYER OVER % "-FIBER S.D.-BOARD OTHER SIDE STC/44 SOUND TEST OR 65-10 FIRE RATING/2 HR. COMBUSTIBLE/FIRE TESTT-2557 Matarials Usad 1. 34*' Steel Studs. 24' o.c. 2. 34* * Floor and Ceiling Track 3. V* ' Fiber Sound Deadening Board 4. Laminating Compound 8. 4* * Flrestop* Typo X Gypsum Wailboard 6. 1' and 14**Typo S Drywall Screws - "^320 ttl^P FIRESTOP^-LAYERS^ SIDES STC/47 SOUND TEST OR 64-52 FIRE RATING/2 HR. COMBUSTIBLE/FIRE TESTT-2557 Materials Used 1. 34*' Steel Studs. 24* o.c. 2. 34* ' Floor and Ceilino Track 3. Laminating Compound 4. 4* ' FIrestop* Type X Gypsum Wailboard 8. 1' and 14** Typo S Drywall Screws -%4*G^P FIRESTOP3H-I3AYERSKSIDES WITH INSULATION IN CAVITYl^^v STC/52 SOUND TEST OR 64-50 FIRE RATING/2 HR. NON-COMBUSTIBLE/TEST T-2557 Materials Used 1. 34* ' Steel Studs, 24* o.c. 2. 34*' Floor and Ceiling Track 3. 4*" Firestop Type X Gypsum Wailboard 4. IV* ' Fiberglass Insulation 5. Laminating or Joint Compound 6. 1 * and 14* ' Type S Drywall Screws E/18 at* nooa am ctiuw mm SGP 0023099 |rG-P FIRESTOP*. OVER Ya" gypsum sound deadening board STC/47 & 52 SOUND TESTS: BW 33ST, BW 34ST (WITH INS.) FIRE RATING/1 HR. NON-COMBUSTIBLE Materials Used 1.1%' Steal Studs, 24* o.e. 2. 1%* Track 3. V G-P Vi ' Gypsum Sound Dasdsnlng Board 4. ft * Plrestop* Typo XXX Wallboard or Plrestop* Etarnawall X 1% * Type "S" Drywall Screws X 1 V * Type "S" Drywall Screws 7. Vi' x 6' x 12* Gypsum Board Spacers I. 1 % * Fiberglass Batts (on BW-34ST tor 52 STC) r*G-P FIRESTOP'-OVER V* ^GYPSUM SOUND DEADENING BOARD STC/41 SOUND TEST G&H BW 2-MT INR + 25 (WITH CARPET & PAD) FIRE RATING/1 HR. COMBUSTIBLE/EST. BASED ON L 503 (U.L 46) Materials Used 1. 2* x 10* Wood Joists X Carpet and Pad X Vi * Particleboard Underlayment 4. % * CD Grade Plywood Subfloor 5. V * G-P Gypsum Sound Deadening Board X %* G-P Flrestop* Type XXX Wallboard 7. 4d Ring Shank Nails; 6d Common Nalls; 8d Common Nails b#G7.:FlRESTOPnON RESILIENT METAL FURRING 1E(FL00R/CEILING) STC/47 SOUND TEST TL 64-155 FIRE RATING/1 HR. COMBUSTIBLE/FIRE TEST L502 (U.L 33) Materials Used 1. 2' x 10' Wood Joists 2. Rosin Building Paper X 1 * x 6* Tongue and Groove Subfloortng 4. 1 * x 4* Tongue and Groove Finished Flooring X Donn DG-8 Resilient Channels X % * Flrestop* Type XXX Gypsum Wallboard 7. 1'Type "S" Drywall Screws and 5d Nalls SG-P FIRESTOP^ON RESILIENT METAL FURRING *<FLOOR/CEILING) STC/48 SOUND TEST L-224-4-65 FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2* x 8* Wood Joists--18* o.e. X % ' Plywood X 44 ox Wool Carpet X 40 ox All Hair Pad X 3' Insulation X Resilient Channels 7. %* G-P Flrestop* Type X Wallboard X 8d Nails X 1 * and 1 % * Drywall Screws hafe-P*FlRESTOP1*4NSULATION*WITH>CEILING^INDEPENDENTOF FLOOR INR + 29, STC/51 SOUND TESTS: KAL-224-14-64, KAL-224-1565 FIRE RATING/1 HR. COMBUSTIBLE/EST. Materials Used 1. 2' x 8' Wood Joists XV4'Plywood X 44 ox Wool Carpet 4. 40 ox All Hair Pad 5. 8d Nails X 2' x 4' Joists 7. 3' Insulation X %* G-P Flrestop*TypeX Wallboard SGP 0023100 E/19 Water Resistant Wallboard G-P Til Backer Board is a water-resistant gypsum product with a light blue face paper, designed for use as a base for the adhesive application of ceramic, metal or plastic tile. The gypsum core consists of incombustible gypsum rock, combined with an emulsion giving high water resistance. This new G-P product Is ideal for bathrooms, kitchens, powder rooms and all high moisture areas. For fire rated partitions between bathrooms or interior areas subject to moisture use %' Rrestop Tile Backer proven by Underwriters' Laboratories in a 1-nour assembly over wood studs. The raw edges of Tile Backer Board (end joints, cut edges, cut-outs) are to be caulked with an approved waterproof non-hardening caulking compound. As an alternate to caulking, G-P can provide a special 2Vi" wide self-adher ing vinyl tape to place over edges and cut-outs. : r r : Column Fireproofing Rreproofing with G-P Firestop Gypsum Wallboard provides a fast, efficient and economical method of protecting steel columns. Fire resistant assemblies of two, three and four hours are obtainable depending upon the number of layers of %* or Vi" G-P Rrestop used. These layers are held in place by a combination of screws and metal studs. The two, three and four hour fire rated assemblies of Firestop have passed Official Rre Tests conducted by the Underwriters' Laboratories. Rre Resistance--For three hour protection, two layers of Vi " Firestop Type XXX can be used. Test No. X513 (UL 39-3 hour). Two hour protection can be obtained using 1 layer of Vi' Rrestop Type XXX. Test No. X520 (UL 20-2 hour). These are for heavyweight columns (14 W.F. 228). For lightweight columns (10 W.F. 49) use 4 layers of %' G-P Rrestop Type X for 4 hour protection, 3 layers for 3 hours. Test No. X509 (UL 18) and 2 layers for 2 hour, Test No. 517 (UL 8). Lighter--As compared to other types of fireproofing, a dead load saving of from 50 to 75% can be realized with G-P Rrestop Column Rreproofing. Speed of Erection--G-P Rrestop Gypsum Wallboard can be installed quickly and easily when used for column fire proofing following G-P details. Minimum amount of the wire and adhesives are used. y .. . .... I. . . - ....... . -- i ------------- - ; L I SHOWER RECEPTOR ILLUSTRATION--THREE-HOUR Are rated steel column assembly with % " Firestop. X509 (UL 18). For tire and sound relad construction ms Tils Bscksr Board must sstsnd to ttts Hoot. E/20 ILLUSTRATION--TWO HOUR fire rated steel column assembly with %" Firestop. X517 (UL8). SGP 0023101 Application Over Masonry Wails On masonry walls either above or below grade, be sure the wall is properly waterproofed before studding of furring is applied. Although moisture barrier gypsum wallboards are available--they are no substitute for proper waterproofing. Wood Stripe or Metal Channels: Apply furring horizontally or vertically. Space 16' o.c. for ft* and ft* wallboard, and 24* o.c. for ft' and ft* wallboard. Use concrete stub nails or power driven fasteners to install furring. Wallboard should be applied at right angles to furring. Use Georgia-Pacific Insulating Wallboard. Installation Details Application of Rigid Predecorated Panels to Gypsum Substrate Use ft in. or ft in. gypsum wallboard. Attach to studs with 1 ft In. wallboard nails, 1 in. drywail screws (metal studs) or drywail stud adhesive. Joints need not be taped or sealed. Install the gypsum wallboard vertically with the edges cen tered on the framing members. The rigid predecorated panels should be applied using a bead of panel adhesive over each stud. Secure paneling at top and bottom plates with 4d. finishing nails 12 in. o.c. and one at mid-height per stud. The addition of gypsum wallboard as a substrate when using predecorated panels provides increased FIRE RESISTANCE and SOUND CONTROL Test Results (Ns Oys--) Bum thru Time Better Sound Rating Better Impact Resistance 8 min. 26STC 26 Sawllna WWi * I*. eye*-- 42 min. 40STC 82 San*lls With to In. Oys--n 73 min. (pfua) 40STC 82 Georgia-Pacific GrabitTM, a Masonry Adhesive: Apply 1* ribbons of Grabit to each edge and 16* o.c. in field of back of each piece of wallboard. Be sure surface to be covered is reasonably straight, and free of fragments of mortar or other protrusions. The adhesive fills in irregularities in the masonry surface. Grabit may also be used to apply wailboard to polystyrene insulation material that has been used against the masonry. Grabit may be used without water proofing on exterior walls which are above grade. Tem porary fasteners or bracing may be necessary until Grabit sets. 4m- i-i * i "iir ,1. * TrS K1 xUIIg. E/27 SGP 0023102 Wood and Steel Stud Application There are many different kinds of construction systems and all are based on the requirements of your particular build ing installation. Basically, the main considerations are us ually: Fire Resistance, Sound Transmission, Relative Strength of the installation. Dimensional Restrictions and lastly Economy. After the wall and floor and ceiling constructions have been selected, it is important that they be installed property. The following precautions should be taken during installation to avoid situations or conditions which will detract from the sound control properties of the assembly: Avoid connecting plenum chambers, ducts, vents, etc. These permit the unrestricted flow of sound. Corrective measures are to make partitions full height, and use ducts lined with absorbent material. Materials: Alt gypsum wallboards, metal runners and ac cessories, joint system products used, shall be G-P Gypsum Wallboard %', Vi" or thick Regular or Firestop, 4' wide x ceiling height for vertical application or up to 16' long for horizontal application, tapered edge. Framing: Prior to the gypsum board application, all framing members should be true and firmly nailed in a plane sur face. Provide double studs at all corners. Both inside and outside intersections are formed by extending one edge of a panel over the other edge in a flush position and covering with tape and joint treatment. In singly ply installation, all ends and joints of gypsum wallboard shall occur over fram ing members, except that this is not required for treated joints at right angles to framing members. Application: Gypsum wallboard may be applied horizontally or vertically to framing with nails or screws. (Alternate meth od-stud adhesive may be applied to studs before applying gypsum wallboard.) The gypsum wallboard shall be attached with nails meeting ASTM-C514 or with iy" long G-P Type "W" drywall screws--1' long G-P type "S" Drywall screws. Solid and Semi-Solid Gypsum Partitions Oher systems of drywall construction consists of the ab sence of wood or metal studs, either of which has its par ticular fire resistance deficiency value. In the following four systems (partially explained below) the common factor in each is that they are all constructed (except for floor ceiling runners) entirely of some form of gypsum incombustible material. 2" Solid Laminated-- (Non-Load Bearing) A 1' gypsum core board with a V4' gypsum laminated to each side; no air space, a 2' solid wall. Has a 2 hour fire rating, economical to buy and construct, an STC rating of 35, creates smooth monolithic walls and creates extra usable floor space. 2" Solid Laminated Floor and SINGLE PLY GYPSUM WALLBOARD MAXIMUM FRAMING SPACING Wallboard Thickness Application %' sidewalls.........................................Horizontal or Vertical Yt" sidewalls......................................... Horizontal or Vertical H' sidewalls.........................................Horizontal or Vertical NAILING OR SCREW SPACING FOR SINGLE-PLY GYPSUM WALLBOARD 2Va" Semi-Solid Laminated Gypsum Wallboard IS'o.c. 2% Semi-Solid Laminated--(Non-Load Bearing)--A cen 24'o.c. ter vertical rib (or stud) composed of 2 layers of gypsum 24'o.c. laminated (1' x 6" rib, 24' o.c.) is the base upon which % ' gypsum wallboards are laminated to each side. This leaves intermittent 1' dead spaces for wiring. Has a 1 hour fire rating, simplicity of installation saves money, a 30 decibel STC, creates smooth walls and provides extra floor space. Wallboard ThlckiMss (Framing 18' o.c.) Single Nailing Double Nailing %' sidewalls.......................... 8' o.c. Max........................ 12' o.c. Max. V4" sidewalls.......................... 8' o.c. Max........................ 12' o.c. Max. H' sidewalls........................ 8' o.c. Max......................... 12' o.c. Max. Framing 18" o.c. Framing 24' o.c. Wallboard Thickness Screw Spacing Screw Spacing sidewalls......................18'o.c. Max........................ -- V4' sidewalls........................ 16' o.c. Max.........................12" o.c. Max. H' sidewalls.......................16' o.c. Max......................... 12' o.c. Max. NOTE: Nails or screws should be driven not less than H' from edges or ends of panels. While fasteners are being driven, the wallboard shall be held in firm contact with the underlying sup ports. Preferably, application of fasteners should proceed from the central portion of the wallboard to the ends and edge. Dimple nails or screws without breaking the face paper. Joints: All joints should be taped and finished with tape and joint compound, nail or screw heads should be finished with joint compound. Exterior angles are covered with G-P Metal Casing Beads and finished with joint compound. Double Solid Laminated-- (Non-Load Bearing) Consists of laminating Vi" gypsum wallboard to a 1' tongue and groove coreboard homogenous or laminated on each side of a 3' air space. There is absolutely no connection over the air space except at the jambs. Has a 2 hour fire rating, greater strength than standard frame or thin solid wall, a 47 decibel STC and smooth wall surface. Triple Solid Laminated-- (Non-Load Bearing) The center piece is a 1' gypsum core panel running the height and length of wall, on one side of which is dead space the other side is filled with fiberglass insulation. Outer sec tion of wall (on both sides) is a Vi" wallboard laminated to 1" coreboard (this gives a 1 Vi" wall on both sides of center section). This gives a three hour fire rating, a 57 decibel STC and smooth monolithic walls. E/22 SGP 0023103 %" Firestop*--2 Hr. RatingIncombustible, Floor/Ceiling 2' SAND-GRAVEL CONCRETE U.L. Design Q505 (UL 259)--2 Hr. (with 2' concrsts) G-P produces lighter weight board and better fire resist* ancei %" Firestop Gypsum Wailboard reinforced with glass fibers covers all ratings listed by Underwriters' Laboratories for the %' thick material. This means that G-P %' fire-rated board can be used In all kinds of wall, floor and ceiling assemblies. The 10% reduction in weight can result In savings in labor and materials in multiple story construction. Firettop V FI RfSTOP Metal furring ChtnMl riaiMta H' fiwstop res > Oil-- Wee V rmtSTOF Drywall Nails & Screws Selector Guide | . __________ . r Peearlatlea ApgHeetloee m'em-MAiMBK Hint Kill 12V* (a.; wit* alight taper to a mall fllltf it shank. (right flnfMi mac diamond at V*'. H* and V* VYtllbdMdi V*' and Vfe* Gypaum Sactar teard to wood frama IV*" Aamilar Rlnc MU (Sum at GWS-S4 xcept for length) *** Wailboard ta wood fraaw 2*** 7d MH 13 V*' diamond haad H* Fiiaatap wailboard faca layara avar v*' Baatwall Sound Oaadanlng Soard ar 2 layara H' Fimtap ta woad Jtuda lVMMUUfi, V*' diamond hood V*' sna t*' willboaid mv mating surface, wood frama V*' dliiawd Mad %' flrwtoe nraitboart to mtihmm ;1 a-saaa- V*' Flrattap Wailboard to woadfraoN IV*' Matching Color Pradacerated Gypaum Wall- ;' Haad NaU (Stddl) boardi ta wood frama ovar ailftlns turfacn, wood trama Pradaeoratad Gypaum (Mi1 Mar Haad Mil (Sriat) board (coton) to wood (mm Wflberd la Matal Framtaf A ^=sammmm 1' OrywMI 1cm Typo 3 IV** Dryunll Jem. I?? Drywall Jem* trous 1H* Orywall Jem. Mafia layer Wailboard ta 23 gauga staal Jtuda. wailboard to Ratmaat Chaanal. wailboard ta Matal Furring. 1' earn ualta to l Kumar in 2* Solid and Soml-JolM Partition Syatama. Oouble-Uver wailboard ta 23nu(o Stoat Jtuda. Doubla-layar wallbaatd ta Matal Furring. ^^SSeeMBddMMM Drywall Jem. Paubla Uyar Wailboard. kkanooBM ' 1* Drywall Jemr Typo J-u AIM tvallaWa la V*', IW S 1*4* langtht For tingle ar multWtyer application of wailboard to heavy faua ataat (us ta 12 gauge). WaHMardM Wood IV*' Drywall Jem. PraaUap ngniot Typo w Slnfla Laytr Wailboard to wood Framing. Wailboard ta aysaum Rlba ittmttltM IV*' Drywall Jcraw TypuG wailboard to Gypaum Riba in Sami-Solid Partition Syatama. Wood Trial a Matal Praams A 9----------- 1H* Dnrwall Jcraw Typo J Trim Head 2V** Drywall Jem. Typo J Trim Haad wood trim over tingle layer of wailboard on 23 louse Steal Jtuda. Wood trim ovar double layer Wailboard on 23 gauge Staal Stud*. Matal Stada la Oaor Fraawa aad Himaara d)* V*'Drywall Jem. J-12 Pan Haad Matal Odor from* to 12 gauga (max.) Steal Jtuda. Matal Stada ta Matal Runner*. Matal Trim Door Hlaaa V*' Typo J-ll Oval Haad Door hinges to door frama MMatal Pramlas Alia availafila in V**, and aluminum components I tCCXBMM IV*' S 1H' laRftht ta matal. Harttaatal aad Yartical tpplleatiaai TYP J AND G--Matal atuda ar furring spaced 24' on cantar. Scrawl mould bo spaetd 12* on canttr union otftarwiaa nottd In lira dalailad aasampliaa mown in Georgia-Pacific litaratura. TYPt w--wood atuda 16' or 24' on cantar. Scrawl mould bt spaetd 12'on cantar unltu oUitrwitt noted In tire detailed aaaemoiits shown in G-P litaratura. Salactlon at ttie propar nail for each application It astramaly important, par ticularly for fira-rattd construction!. The nailt racommandad comply with parformanca standarda adoptad by tho Gypsum Auociatlan. SGP 0023104 E/23 ETERINIAWALL" VINYL SURFACED GYPSUM Combines gypsum wallboard with the beauty of sheet vinyl These fire-resistant panels are factory laminated with a quality, washable vinyl sheet providing a permanent scuff, crack and chip-resistant surface. Colors are fade-resistant and the texture or design will not be impaired when cleaned. Etemawall panels are available In 12 standard colors and 3 simulated woodgrains. The long edge is completely wrapped with vinyl and eased to form a modified beveled edge. Georgia-Pacific FIrestop* Etemawall"' Is available when the wall construction requires the wallboard to be of fire rated construction. Firestop* EtemawallTM has a wallboard base containing greater glass fiber reinforcement and unex panded vermiculite. Specifications All vinyl surfaced gypsum wallboard indicated on the draw ings shall be Georgia-Pacific EtemawallTM as manufactured by the Gypsum Division of Georgia-Pacific Corporation. The panel construction shall consist of an unsupported vinyl sheeting of wall surfacing grade factory laminated to G-P Regular or Firestop* Gypsum Wallboard. The long panel edges shall be a modified bevel and completely wrapped with vinyl. The colors and patterns shall be as selected from the Standard Une of Etemawall. PRODUCT DATA Thickness: ft', ft', Vi" and H" Regular Gypsum Wallboard, Vi' and ft' Firestop* Gypsum Wallboard. Vi" Regu lar EtemawallTM Is the stock thickness. Sizes: 4' x 7* to 4' x Iff in one foot increments. Special lengths on request. Special size (length and width) Etema wallTM partition board available on special order basis. 4' x ff and 4' x 10' are the stock sizes. FIRE HAZARO CLASSIFICATION ft', Vt' and ft* wallboard consisting of gypsum core, sur faced on both sides with paper or with a vinyl facing on one side. Pin Hoar# ClessMeatfon eele Soars Win Vinyl Paatof Flame Spread 15 25 Fuel Contributed Smoke Developed 15 10 0 20-50 Classified by Undarwrltora' laboratories, Inc. EDGE DETAIL Modified Bavolad Edge Color coated stainless steel nails are available to match ail Standard colors and woodg rains. Trim accessories are available in ff x 10' lengths to match all standard colors and woodgrains. TRIM ACCESSORIES Snap-On Comar Bead Snap-On IntariorTrim The above trim accessories and color coated stainless steel nails are available to match all Standard colors and wood- grains. SOUND CONTROL PARTITIONS--EtemawallTM Surfaced These fire and sound rated vinyl-surfaced wallboard sys tems eliminate the need for battens. G-P Firestop* Etema wallTM is laminated directly to G-P ft' Incombustible Gyp sum Sound Deadening Board. They are not only simple to install but they are inexpensive and provide a very durable wall. TANaEftlNC Application Demountable wall systems are Installed by using any of the appropriate or approved color-matched moldings. To lami nate to existing wall surfaces, use G-P Laminating Com pound and secure panels mechanically at top and bottom plates. Panels may be applied with adhesive directly to metal studs, wood framing or furring strips. For application directly to masonry walls, use G-P GrabitTM Masonry Adhesive. E/24 U.L. Design No. 30 Firs Rating--1 Hour Combustible STC-4S U.L Design No. 32 Fire Rating--1 Hour Incombustible STC-45 SGP 0023105 Metal Components Laminated Gypsum Enclosure System Description Georgia-Pacific Shaft Liner Is a solid gypsum board parti tion for enclosing elevator shafts, stairs, smoke towers and other such shafts. It Is a non-load bearing wall, designed for resistance to uniform wind loads without excess deflection. Important advantages of the system are: 1. Much lighter weight than masonry, Z Non-combustible and economical, 3. Can be completely erected from one side, 4. Practically eliminates the need for scaffolding, 5. Panels can be individually removed for backside maintenance, 6. Minimum clean-up. 2 HOUR SHAFT WALL PARTITION The partition consists of a basic pre-laminated core unit 1 % ' thick by 24" wide, which fits into a top metal "J" track and bottom "L" runner. Metal "T" splines are inserted be tween each core unit. The core units are subsequently se cured to the "T" splines, and top and bottom runners. Installation of the facing layers and surface finishing can be accomplished later to coincide with interior partitions. This system meets the ATSM El 19 requirements for 1 4 2 Hour Fire Resistive Classifications. It is also designed and tested to meet a variety of wind loads at various heights. The standard gauge of the metal components is 20 gauge. However, other than the 20 gauge may be used, as shown in the table on the following page for various wall heights, deflections and wind loads. The facing generally consists of 2 layers of % ' G-P gypsum board. The exposed layer may be %' Dens-Cote Base and Dens-Cote Veneer Plaster, or Vi' G-P Tile Backer. G-P Shaft Liner System has passed the following fire tests: 1 Vi Hour System--Ohio State Univ. T-4982 2 Hour System--Ohio State Univ. T-4958 2 Hour Chase Wall--Ohio State Univ. T-4991 2 Hour Alternate Wall Underwriters Lab. Design 42. Components of the Georgia-Pacific Shaft Liner conform to the following specifications: Wallboard, Vi' and % ' Wallboard, 1' Dens-Cote Base, Vt" and %' Dens-Cote Veneer Plastic Tile Backer Metal for Components ASTMC 36 ASTM C442 ASTM C588 ASTM C567 ASTM C630 ASTM C446 Installation Basie 2 Hour System (T-495S) Install the perimeter framing first which consists of the top metal "J" and bottom "L" tracks. These components are to be secured with power driven fasteners, or equivalent, at 24' maximum centers. The 1%' Shaft Liner core units are inserted top first into the "J" track and pushed flush against the bottom angle runner. These core units are sep arated by the "T" splines, which are positioned so the flat, or flange, side faces the shaft. Type S-12 drill point screws 2'-2%" long are used, 24' o.c., to fasten the core to the "T" splines. At the extreme top and bottom, screw the core to the runners, at points 2* on each side of the spline, using the drill point screws. Screws will protrude slightly on the unfinished shaft side. Two layers of Vi ' Georgia-Pacific Regular Wallboard, 4 ft. wide by partition height are applied to the face side. Each is installed parallel to the Shaft Liner panels. The first layer is offset from the "T" spline by 12', and the second layer staggered 24' from the first. Installation is by %' beads of adhesive, or full lamination. For improved sound isolation, adhesive should fill the joints at each "T" spline. The fac'ng sheets are also secured with 1%' Type G screws spaced 24' o.c. at edges and center (1st layer) and 16* o.c. at edges and center (2nd layer). Finish joints and screw heads in nor mal manner in preparation for the final decoration. SGP 0023106 E/25 Itemate 2 Hour System (UL42-2 Hour) he "L", "J" and `T' metal components and the 1H ' core nit are erected in the same manner as the basic system, wo layers of %' G-P FIrestop* wallboard 4' wide by partion height are then applied to the face side. Use adhesive )r laminating compound) and screws as described in the asic system. Use 1%' screws on finish layer into "T" dines. See page E/31 for details. Hour Chase Wail (T-4991) iter erecting metal components and 1H ' core unit, install i-P "L" angle runner horizontally on 40' centers through ore unit to "T" spline. Erect 2Vi", 25 gauge steel studs and ack 3' from core unit. Brace studs with angle runner, pply one layer of H' Rrestop* to studs. See page E/31 or details. 1% Hour Wall (T-4982) The "L", "J" and "T" components and the 1H' core unit are erected in the same manner as in the basic 2 Hour system. The one layer of H" G-P Rrestop* is screw-lami nated to the core unit and metal components. Offset joints from "T" splines by 12'. The Georgia-Pacific Shaft Liner System is designed for versatile performance. Ease of construction from one side makes this wail ideal for use in locations other than vertical openings (such as stairwells). The system takes much less space than masonry or stud walls. Both sides can be finished by adding a layer of regular board over the "T" flanges on the back side. However, if the back side is to be finished, the wallboard should be applied first before screw attaching the Shaft Liner panels to the metal components. :. INSTALLING FLOOR TRACK. 3. ATTACHING CORK TO T-SFLINt. E/26 SGP 0023107 4x shaft Oner HEIGHT SELECTION TABLE syoMm 1% Hour Wall Vertical Qiygi f. 22 fti_ :t f 20 jr` Deflection L/120 L/240 L/120 L/240 HEIGHT BASED ON POUNDS PER SQUARE FOOT S 7J* 10 124* 10 10' 9 9* w 8' -- -- -- 14'4* 11'4' 12* 10' 10'1* 11'4* 9* 10'7' 8' 1* 9'10* 7'10* 2 Hour Basic Wall 22 r L/120 10' 10* 10* 10* 9 L/240 10' 10* 9 8' -- f 20 L/120 L/240 ir 13' 9' 15' 4' 12' 3* 13' 8* io* ir 12*10' 9'7' 19 8' 6' v 18 16 14 L/240 14' 12* 8' 11' 9*8' 8' 8' L/240 L/240 15' 18' 13' 12* 10* 14' 12*8' 11' 9 19 2 Hour Chase Wall 16 ga. 3%' Steel Stud L/120 23' 20' V 18'3' 171* 15*11' 25 ga. 2%' Steel Stud 16ga.3%' Steel Stud L/240 14' 18'3' 12* 18' 4' 10* 14'8* 8* 13'7' -- 12*8' 2 Hour Alternate Wall r. 1 22 20 L/120 L/240 L/120 L/240 10' 10* 19' 15' r 10' 10' ire* 13'6' 10' 9 15' 11'11* 10' 8' 14' 11'2* 10' -- 13'2* 10' 5' NOTE: 22 ga. "T" splines should not bo used over Iff 0' 'Haight soloction table based on tests by Wiss, Jannoy, Elstner & Associates General Working Conditions During cold weather, temperatures In the building should be maintained at not less than 50F during application of adhesives or joint treatment. There should be adequate ventilation to dispose of excessive moisture during these periods. For steel frame construction, installation of top "J" track should be completed before application of any spray-on fireproofing. The poured concrete floor should be reasonably smooth in the area where the "L" track is to be installed. If the "L" track is installed close to the edge, the concrete may spall unless a fastening plate is set into the concrete to which the track can then be applied. The "T" spline and Shaft Liner panels should be no shorter than %' less than height of the shaft opening. Limitations 1. Georgia-Pacific Shaft Liner walls are non-load bearing.' 2. Do not use in areas of unusually high moisture conditions. 3. Electrical or mechanical piping, wiring, etc. should not be incorporated unless furred construction is used. 4. Adhere to gauges and heights shown in table. 5. Provide control joints at maximum 30 ft. intervals. 6. When hand rails or other heavy items are anchored to the Shaft Liner System, install 22 gauge metal strip be tween the Shaft Liner panels and facing layers. SGP 0023108 E/27 Concrete Beam DETAILS 2 HR. FIRE RATED WALL Wall Intersection HV Q-P ANGLE RUNNER OR T1 ' 'r''' , * ' *. * .1 1 ... - * . M *. 1 V- - - <! -J* .t , ^ Top ^--------- CAULK AS REQUIRED / -- SCREW ATTACH / A *A / 1-- G-P "J" TRACK 1*' G-P LAMINATED CORE UNIT End Bottom W"G-P GYPSUM WALLBOARD Corner G-P ANGLE RUNNER SCREW ATTACH CAULK AS REQUIRED E/28 SGP 0023109 Steel Beam Handrail Attachments Column Bypass 1H' METAL TRACK. 25 ga. 1H" METAL STUD, 25 ga. Corner Column E/29 Rough Door Opening Duct Opening Section "A" Elevator Door Head Section "A-A" Duet Opening ACCESSORIES TO BE SUPPORTED SEPARATELY E/30 SGP 0023111 Expansion Joint Wall Assemblies Outlet Box Chase Wall SGP 0023112 E/31 distribution centers hmingham 3400 Ball St 440 Magaztna Ava. IDAHO 3451 Geciyia-Paeifle Ava. A Betttlne Hwy. MOIMOMfy 4542 Baldwin Ava. ARIZONA 4aoi*We Cottar SL 3101 Dugan St CALIFORNIA S19E. Kataila Ava. Sarkatay 800QrayaonSL LoaAngaiaa 14750 Nelson Ava. City of Induatry 5286 E. Home Ava. NvarMda 1460 Citrus SL 2951 Oranga Grove Ava. North HigMands fmiTnduatnal Ava. 2200Hatfly St National City 7891 DaartngAva. CanogaPark San Joes 660 East Gish Rd. COLORADO 1575 Commarca Ava. IOWA 5831 Northaast 17Th St. 10450 Wavatand Ava. Franklin Park 17040 Lathrop Ava. Harvay 208 Waal Camp St INDIANA Elkhart 225 Collins Rd. 520 N. CongraasAva. Fort Wayna 7803 Nalaon Road inRanapoBa 310 So. KltlayAva. Wichita S755S. Hoovar KENTUCKY 4820 Allmend Ava. LOUISIANA Evangeline Thruway, S. NawOrtaana 7500 Almonastar Ava. Mwtslieid Read at Valley View P.O. Baa 8287 1506 W. Third Ava. CONNICT1CUT WaMngford 805 N. Colony St DELAWARE Wilmington Marina Tarminal PLORIOA JackeonvBie 1333 Halnaa St 32oTn.W. 110th St 2721 Regent Ava. Tattahaaaaa 889 Mabry St Tanga 3701 E. Columbus Dr. Wttf Nin dtedi 900 W. 15th RlviaraBaaeh QIOROIA 1013 Worth SL Atlanta 125 Otttay Ortva, N.E. YffGordon Highway 508 Warren Ava. MARYLAND 6813 Quad Ava. MASSACHUSETTS 60 Kendrick St Needham Heighte MICHIGAN Grand Raplda 825 Buchanan Ava- 3.W. 126 East HudaonSt Royal Oak MINNESOTA 3101 East Harmspm Ava. MISSISSIPPI 555 Gulf Una Rd. MISSOURI SLLaula 602SByaaaeeOr. Hazelwood Kansas City 1445 Taney St N. Kansas City MONTANA Billings 600 Dsniel St Great FaNa 901 River Orlva South NEBRASKA 545 "L" St NEW HAMPSHIRE 300 Gay SL pfMMnh Hunker Rd. A Rt 119 Now Stanton- 801 First Ava. King of Prussia SL Oak P.O. Bos 37 RHOOS ISLAND 170 Jefferson Blvd. rar-------- 1-. Clifton 400 Allwood Rd. NEW MEXICO 4021 Edith Blvd., N.E. SOUTH CAROLINA Corner Brookwood Dr. A Duval SL Haywood Rd. NEW YORK Albany Brown A Industrial Roads Buffalo 2585 Walden Ava. Rochester 1480 E. Henrietta Rd. 175 Underhill Blvd. Syoaaat 100 Paty Industrial Blvd. ?East2MhSL ta--jm. MBIVilV 1301 MftcheM St. NX 20S7KaNoggAve. NasbvMa 331 28th Avenue N. Midler Park Dr. Syracuse 75 Tuekahoa Rd. NORTH CAROLINA Chartotta 3300 Parkslda Rd. Orasnabata 2704 Patterson Or. Raleigh 3501 Tarheel Drive P.O. Drawer 250 TEXAS 1800 John Cormafty Or. Carrollton o Pin 6990 Marks! SL Fort Worth 400 East Vickery Blvd. 650 Gellhom Or. 702 E. 44th St SanAntanla 535 No. W. W. Whita Rd. OHIO Akran 2644 Gilchrist Rd. Cincinnati 5402 Vina St 19100 Holland Rd. UTAH SaRlakeCHy 2875 South Second. West Lynchburg Groves Mill Rd. at Timberlake Rd. 2100 Refugee Rd. Dayton 4395 Springfield St Totada 2815 HUI Ava. OKLAHOMA Oklahoma City 5519 N.W. Fourth SL Tuiaa 8531 East 44th OREGON lugifll 885 McKinley St Portland 330 S.E. Division PI. PENNSYLVANIA LjMflflllr 549 W. Roseville Rd- 3587 Argonne Ava. ComerOabneyA Bethlehem Rds. WASHINGTON 12815 N.E. 178lh SL Woodinvflle 4320 E. Trent Ava. 2302RossWsy WASHINGTON, O.C. 8121 Ardmore-Ardwick Rd. Landovar, Md. WISCONSIN MHwmhf 5059 N. 119th St Ws Support ThGss Associations I GYPSUM AMOCXATXON GYPSUM SALES OFFICES CAUFORNU Los Angeles--213/968-8581 DELAWARE Wilmington--102/658/7221 GEORGIA Atlanta--404/673-6361 ILLINOIS Chicago--312/678-2273 KAMSAS Kmsm City--21 I/S42-33M MICHIGAN Detroit--313/664-4806 TEXAS OellM--214/242-4221 WASHINGTON Woodtnvttle--206/466-6146 WASHINGTON. O.C. Landovar, Md.--301/773-3320 GeorgiaFfedfic ^ GROWING FORESTS FOREVER SGP 0023113 Uthofrsplifd In U.S.A. sn 6-P Kslsmstoo Coronet tnamtl 70 lb.