Document XOJz5gNyXQQXMx9VJaMKoYOmy
V. B. PAPAGEORQE - ST. LOUIS November 11, 1970
Letter Dated Oct, 27/ 1970, R. P, Casey, Ohio Edison to P. a. Benignus
P. 0. Benignus
,
ra)fEX/VHOIB. I<Tftx
Below are ray comments concerning Mr, Casey's letter.
1. Item 2 of Don Olson's letter was appropriate in February because there was no evidence that PCB's with lower chlorine content were being discovered in the environment. Since then, there has been increasing evidence that PCB's similar to Aroolor 1248 arid Aroclor 1242 are being identified es pecially near industrial plant effluents. There is also evidence that these lower chlorinated materials are having adverse effects on some species of wildlife.
2. As you know a high percentage of the Aroclors we produced had a chlorine content less than 54#.
3. Testing of new formulations continues. MCS 1016 is an example of a formulation which reduoes the more objectionable PCB's. Samples have been forwarded to capaoitor customers for evaluation. We have not discussed the use of MCS 1016 in transformers. Perhaps a discussion should be held soon with Market ing, Research and Manufacturing.
4. Installation of the Krummrich incinerator is esti mated to oost close to one-half million dollars. Installation of a properly designed and instrumented smaller unit may cost a quarter million dollars. To Justify even the small unit, the quantity of askarel to be destroyed must be substantial. In my opinion very few of our customers will be able to Justify an incinerator of their own.
5* Solid waste soaked with askarel can be safely dies- ' troyed with properly designed equipment which is also very oostly. We are now getting ready to test
the practicality of decomposition by pyrolysis, destruction of the resulting gases at high temper atures and scrubbing of the stack gases to absorb the HC1 which is formed. The economics is not now known. I estimate that the cost to handle, ship and destroy solid waste will be discouragingly high. I recommend using properly operated landfills until they are declared Illegal.
TRAN 036330
HARTOLDMON0024850
-2
6. The capacitor manufacturers have discouraged the utilities from using landfills. I can understand their concern, which I suspect Is legally motivated, but for the time being landfills are the only practical
solution anyone has to offer.
1 hope the above oomments are helpful in responding
to Mr. Casey's letter.
V.
;
ms -
' ' .. . ..
' . W. B. PAPAOEORQB . ' v..'
/.
TRAN 036331
HARTOLDMON0024851