Document XOJq8M0mNbD04989v8DXG7YGG
z,e`
4
i O Wilt?
MON-2523
MUNDY INDUSTRIAL MAINTENANCE INC.
c/.O'
< <11.4119 p. a. box m HOUSTON. TEXAS 770X7
July 12, 1976
Mr. Byron Bums Group Foreman Monsanto Polymers & Petrochemicals Co. P. O. Box 711 Alvin, Texas 77511
Dear Byron:
As a result of our meeting Thursday, We would like to make several recommendations for immediate implementation with regard to our asbestos safety program.
^ 1. Comprehensive pre-employment, annual and post employment medical examinations to be made.
2. Respirators, coveralls and gloves to be worn during all insulation stripping lobs.
3. Old asbestos insulation to be disposed of in Monsanto's dump rather than in dumpsters.
4. Monsanto to conduct a monitoring program for air borne asbestos fibers during stripping jobs.
We will immediately implement Number 1 and request your help in implementing Numbers 2, 3 and 4. As we discussed, we will develop a written compliance procedure incorporating these and other items by October 1st.
Very truly yours,
MUNDY INDUSTRIAL MAINTENANCE INC.
DM.-BIS
cc: Ken McBryde Franklin Poston
David Marchand Division Manager
c 003176
LAM022816