Document XOJ7QpoXGx8YOM3NOQ8Qqmv8w
M. A. F o r c e 3 ~ I " "7^
FC-143 Objective: Determine the fate of FC-143 in the Teflon process.
Status : 90% of FC-143 is absorbed on or incorporated in Teflon. FC-143 is probably decomposed in sintering. Tightly bound FC-143 goes to the customer in I product. Air samples taken at SM-3 and I process show FC-143 to be < 50 ppb in operator breathing zone.
000C04
SPR000555
EID714467
FC-143 DATA
2200 PPM ADDED TO DISPERSION
PP&R Samples Supernatant Liquid Raw Dispersion - 35% Solids Concentrated Dispersion H2O Control
PPM Level of FC-143 in _____ Liquid Phase
220 125 180
3000
Teilori8 Process Wash Reel Water Regeneration Bath
50 Not Detectable
Air Samples
Roll 2 Roll 11 Roll 15 Operations Desk Induction Dryer Exit Above Induction Dryer
Approximate Temp. F 250
690 - 700 680 - 700
75
Level of FC-^143 ppb < 50
NOTE: Air samples were taken 18 inches from the face of the machine and 5 feet high.
000005
SPR000556
EID714468
FIGURE I
'ash Reel 167 g. H20 per g. Yarn
FIGURE 2 "I'1 YARN PROCESS
Vent
000006
SPR000557