Document XOGr10pMa5g0abwey7qd8MoBx

Vista Chemical Company 15990 N. Barker's Landing Rd. Post Office Box 19029 Houston,Texas 77224 Phone (713)531-3200 October 6, 1986 'r! Ms. Nicky Smith Legal Department Conoco Inc. 600 N. Dairy Ashford McLean Building Houston* TX 77252 Dear Nicky: As we discussed, below are proposed answers to the interrogatory questions for which no previous answer has been given. These answers are based on my knowledge and experience since 1980. Interrogatory No. 15 - This answer should be reviewed by someone in manufacturing. The Company's products are produced to meet certain internal product specifications, or specifications agreed to by the customer and the company. Manufacturing and process controls are utilized to meet these specifications. Specification parameters are routinely measured for the finished product to assure desired specifications are met. Interrogatory No, 16 The defendant has no specific records involving personal injury from the alleged toxic nature of said chemical products. Information used to produce product literature and labels was obtained from the open scientific literature and toxicity testing. Interrogatory No, 17 The Company has maintained a file of alleged health effects for it's products since November 21, 1983, in accordance with the Toxic Substance Control Act, Section 8(c) regulations. No allegation regarding the toxic nature of PVC or Cresylic Acid has been received. Interrogatory No. 20 VVV 00001552* No record of any conversation or statements are known to exist regarding the facts of the plaintiffs chemical exposures. As we discussed, other questions and document production requests covered in your letter of September 30 will be referred to marketing or are adequately covered by previous responses. Also, our Newark files were sent to Conoco/DuPont at their request, soon after Vista closing. Ms. Nicky Smith Page 2 October 6, 1986 Notice to Produce - No. 16 Below is a list of applicable governmental documents in our files. March 5, 1980 - Human Exposure to Atmospheric Concentrations of Selected Chemicals; Systems Applications, Inc. EPA Contractor Report ACGIH TLV Booklet - purchased annually ACGIH Documentation of TLV's NIOSH Criteria for a Recommended Standard - Occupational Exposure to Cresol CFR Wednesday, October 12, 1977, Part IV - Council on Environmental Quality TSCA Interagency Testing Committee; Initial Report to the Administrator Regarding the Material Safety Data Sheets you attached to your letter, these MSDS1s were revised versions we began using during late 1980. They are four page documents but you only sent me two pages for each. If you do not have a four page document for each, please contact me. I have enclosed the MSDS's that were in use prior to the revised four page documents. To ray knowledge these were used from 1973 to 1980. Sincerely, Thomas G. Grumbles, C.I.H. Environmental Quality Manager ajo/9 cc P. Carey vvv U.S. DEPARTMENT OF LABOR Occupational Safety and Health Administration MATERIAL SAFETY DATA SHEET t-con OMH Ne. 44-UUH; - SECTION 1 MANUFACTURER'S NAME EMERGENCY TELEPHONE NO. Pitt--Consol Chemical Company 201/344-3800 Aooat ss (Sumbtr, Street. City, Slate, and ZIP Code) 191 Doremus Avenue, Newark. NJ CHEMICAL. NAM^ AND SYNONYMS phenol ana methylated phenols CHEMICAU. FAMILY phenol, cresols, xylenols and trimecftvi pnenols SECTION II 07.103___ TRADE NAME ANO SYNONYMS Cresvlic Acid FORMULAc6H5OH + CCH3)nC6E5 OH: n " 1 3 - HAZARDOUS INGREDIENTS _______________________________ PAINTS, PRESERVATIVES, ft SOLVENTS TLV % (Unitit ALLOYS ANO METALLIC COATINGS TLV % (Unit*) PIGMENTS BASE METAL CATALYST VEHICLE SOLVENTS ADDITIVES 'TMERS ALLOYS METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX . .. OTHERS / :r.yrr-"?T-rr--; -- -- -----------------:----------------------------------- -- - HAZAROOUSMtXTURES OF OTHER LIQUIDS. SOLIDS. OR GASES - -- ----------------- V .... ..... i.v.: : % " .... TLV (Unit*! - '-! ---------------------------- --------------------------------------- ......_______________________---------------------------------------------------------------------------------------------------- -------------------------------- -------------- ------- ... -. . SECTION III - PHYSICAL DATA --------~----- -------- __ BOILING POINT (*F.| VAPOR PRESSURE (mm Hf.) VAPOR OENSITV (AIR-1) SOLUBILITY IN WATER 375-413#F >3.0 trace SPECIFIC GRAVITY <H30-1) " . PERCENT. VOLATILE BY VOLUME f%> EVAPORATION RATE < Ml freezing point ' ... appi arance and ooor Clear liquid with sweet tarry odor :7 .................. 1.03 r* ^40F SECTION IV - FIRE AND EXPLOSION HAZARD DATA uwd)flash point (Maine* 210*F PM FLAMMABLE LIMITS Lai Utl EXTINGUISHING MEDIA Water, sfog^ , or spray - cfoam ..(.N..F..P, A ,,Co, de 2) SPECIAL FIRE .FIGHTING PROCEDURES ireat with same precautions as high boiling hydrocarbons fapp Mf?A sn--481 ----------- ---------- . . .. ----------.... UNUSUAL FIRE ANO EXPLOSION HAZARDS , . ... .............. -.... VVV 000015526 PAGE (1) {Continued on revere* side) Form OSHA-2Q R*. May 72 SECTION V * HEALTH HAZARD DATA THRrSMOLO LIMIT VALUE 5 ppm Corrosive to any tissue, will cause severe burns and is KFFECTS OF OVEREXPOSURE / ---------------- ---------------------------------------------------------------------------- cause dermatitis and chronic poisoning. TMERGENCY AND FIRST AIO PROCEDURES Call phvsician immediatelv. Wash skin contact with laree amount of soapy --wate-r r wash with alcohol-water mixture if available. Wash eyes with water. For in- gestion give large amount of salt water, sodium bicarbonate solution or milk. roow~wit:n"raw egg wnites or corn starcn paste, induce vomiting. SECTION VI - REACTIVITY DATA STABILITY UNSTABLE CONDITIONS TO AVOID STABLE INCOMPATABILlTY (Materials to avoid) X HAZARDOUS DECOMPOSITION PRODUCTS , Not dangerously reactive HAZARDOUS POLYMERIZATION MAY OCCUR will Not occur CONDITIONS TO AVOIO X SECTION VII * SPILL OR LEAK PROCEDURES STEPS TO 8C TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED Pick, up mechanically________________________________ WASTE OISPOSAL METHOD Biological oxidation or incinerate according to established federal procedures SECTION VIII - SPECIAL PROTECTION INFORMATION respiratory protection (Specify type) When using hot material, use masks ventilation LOCAL EXHAUST approved by U.S. .......... ...... . - - Bureau special of Mines ecHAN,downdraft OTHER PROTECTIVE GLOVES rubber OTHER PROTECTIVE EQUIPMENT EYE PROTECTION --Fui l,l ,leng.th pro^tective c,loth_ i,ng chemical safety goggles SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO RE TAKEN IN HANOLINO ANO STORING . ... . ' ' -.- OTHER PRECAUTIONS -- PAGE (21 PO 1)4.110 ................. The above data are based on tests and experience which Continental believes reliable and are supplied for informational purposes only. 5527 1 Form OSHA-20 Raw. May 72 U.S. DEPARTMENT OF LABOR Occupational Safety and Health Administration MATERIAL SAFETY DATA SHEET l*orm Aepi.wcU OMB No. 44-KIJi; MANUFACTURER'S NAME SECTION 1 EMERGENCY TELEPHONE NO. Conoco Chemicals ' ............. 601/369-8111 AOORE5& (Number, Street, City, Slate, and ZIP Codef P. 0. Box 91. Aberdeen. Mississiooi 39730 CHEMICAL NAME ANO 5VNONvM Polyvinylchloride, PVC TRADE NAME ANO SYNONYMS CONOCO PVC Comoound CHEMICAL FAMILY POAmula (-CH2yH-)x Vinyl Polymers____________ _________________________ SECTION II HAZARDOUS INGREDIENTS . PAINTS, PRESERVATIVES. fc SOLVENTS % TLV (Unit*) ALLOYS ANO METALLIC COATINGS PIGMENTS BASE METAL CATALYST ALLOYS VEHICLE SOLVENTS AOOITIVES <ERS --------------- ' METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX OTHERS - ' HAZARDOUS MIXTURES OP OTHER LIQUIDS. SOLIDS. OR OASES Vinyl Chloride Monomer: less than 1.0 ppm - % * % TLV (Units) --. . TLV (Units) , . .................................... '..................... : ._ - - - ....-- - BOILING POINT (*F.) VAPOR PRESSURE 4mm Hf.) VAPOR OCNSITV (AlRl) SOLUBILITY IN WATER APPEARANCE AMO ODOR SECTION III - PHYSICAL DATA solid solid solid nil SPECIFIC GRAVITY (HsOt) PERCENT. VOLATILE BY VOLUME Ok) EVAPORATION RATE i -11 <0.52 solid SECTION IV - FIRE AND EXPLOSION HAZARD DATA FLASH POINT (MBtne* utM) Not aoolicable FLAMMABLE LIMITS LF UP EXTINGUISHING MEOIA Water. COi. dry chemical---------------- ------------------------------------- ------------ ___________________________ _______ SPECIAL FIRE mOHTINO PROCEOURC3 Uhen fiahtino fires in confined spaces, self-contained breathing apparatus should used. UNUSUAL FIRE AND EXPLOSION HAZARDS Evolves hydrogen chloride and other toxic oases when burned products should be avoided. Exposure to combustion PAGE (1) .JJ'N 1 (Continued on rovers* side) Form OSHA-20 r*v. Mbit 7* SECTION V - HEALTH HAZARD DATA TMftFSHOLD LIMIT VALUE None established. ACGIH TLV of O 10 mq/irr total dust recommended EFFECTS OR OVEREXPOSURE 'Exposure to FVC as such poses no overt hazard. In confined usaqe or storaae areas, use adeauate ventilation. fMCRGENCV ANO FIRST AIO PROCEDURES Flush eves with larae amounts of water. - SECTION VI - REACTIVITY DATA STABILITY UNSTABLE CONDITIONS TO AVOlO STABLE (NCOMPAT ABILITY (Materials to ovoid) X HAZARDOUS DECOMPOSITION PRODUCTS HAZARDOUS POLYMERIZATION MAY OCCUR WILL f*OT OCCUR CONDITIONS TO AVOID --3L- .. *e SECTION VII SPILL OB LEAK PROCEDURES STEPS TO SC TAKEN IN CASE MATERIAL. IS RELEASED OR SPILLED Sweep ua. WASTE OISPOSAL METHOD Prefer landfill rather than incineration. SECTION VIII - SPECIAL PROTECTION INFORMATION respiratory protection (Specif* tvpe) ___ NTHCM annrnwoH duct ppsniratnr for dus-tv .operations. VENTILATION LOCAL EXHAUST SPECIAL MECHANICAL (Gtnwi) If andicable for dust PROTECTIVE GLOVES None * OTHER PROTECTIVE EQUIPMENT Ground lines on transfer eauioment control. OTHER EYE PROTECTION Safetv classes - *.... . --.....- - - ... ... ... SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO BE TAKEN IN HANOLINO ANO STORING . . l In Title. 29. CFR. Part 1910.1017. 1-A S m - .................................... PAGE (2) jl ere ti4.no The above d^ta are baaed pa tests and experience which Continental believes reliable and are supplied for informational purposes only. VVV UOOOl 5529 ...... ' Form OSHA-20