I. Personnel VCM Exposure
Personnel sampling during the month is summarized in this section of the report. There was one TWA value recorded during the month which was abov 1 ppm.* On November 22, an operator at #3 plant was exposed to 1.01 ppm w dropping polys. Records indicate respiratory protective equipment was wc during the sampling period.
TWA EXPOSURE (PPM)
Department
Resin LPS Lab Maintenance Tech., Adm., & Plant Overall Plant
High
1.01 0.49 0.40 0.75 0.36 1.01
Low
0.03 0.15 0.30 0.22 0.05 0.03
Average
0.37 0.30 0.35 0.40 ~U721 0.33
Samples
5 4 2 6 4 21
Residuals
Product
PVC 426 PVC 450 PVC 470 PVC 500 Exp. & 0G Resins
High
37.79 5.79 7.38
73.94 32.79
Low
0.20 0.02 0.06 0.05 0.74
Average
8.30 1.27 1.66 7.39 13.95
Samples-
12 10 11 53
4
OCC 11620
Safety, Environmental and VCM Reduction Report - November, 1983 Page 2
III* Environmental Air f .... A. Leak Patrol
There were a total of 677 points checked and there were two new leaks detected. Both of the new leaks were fixed, leaving no leaks still needing repair at month's end.
B. There were no reportable VCM releases during the month.
C. There were no reactor openings above the standard during the month.
IV. Environmental Water
i
A. The highest level of VCM recorded for any of the process water sewers during the month was 9.79 ppm. This was the effluent from the No. 1-4 Plant Sump.
The highest level of VCM in the storm sewers was 0.05 ppm.
B. There were no violations at No. 004 Outfall during the month.
C. Wastewater Stripping
There were no violations of the 10 ppm standard during the month.
V. Reclaim System/Flare
Flare Use in Hours ^Permit year is 2/1 to 2/1.
Month 0
Permit Y-T-D* 8 Hr. 45 Min.
VI. Environmental Statistics
A. Suspension Stripping Daily Average (ppm) Days Above Standard Limits
B. Wastewater Stripping
Daily Average (ppm) Days Above Standard
Month
88.3
0
Month 1.36 0
Y-T-D
69.2
2
Y-T-D 1.41 7
OCC 11621
Safety, Environmental and VCM Reduction Report - November, 1983 Page 3
C. Reactor Openings
Number of Charges Number of Reactors Sampled Number of Above Standard Limits Percent Above Standard Limits Charges/Openings
1,689 24
0 0 1/1
Total Reportable VCM Releases
Number of Releases
0
E. Outfall 004
Number of Samples Above NPDES Permit 0
18,350 253 6 2.4 1/1
2
,3
VII. Total VCM Emissions from Stripping and Reactor Openings
Suspension Resin Stripping
Month
Y-T-D
EPA Permitted Emissions - lbs. *Texas Permitted Emissions - lbs.
Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas)
4,430 1,329
978 (351)
48,150 14,445
8,381 (6,064)
^Permitted based on 280 MM Ib/yr. production by State of Texas (allowable residual @ 120 ppm).
Reactor Openings
Permitted VCM Emissions - lbs. Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas)
221 157 (64)
2,406 1,951
(455)
Totals
EPA Permitted Emissions - lbs. Texas Permitted Emissions - lbs. Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas) % of Permitted Emissions (Texas)
4,651 1,550 1,135
(415) 73.2
50,556 16,781 10,332 (6,449)
61.6
OCC 11622
Safety, Environmental and VCM Reduction Report - November, 1983 Page 4
MUU Injury Report
Resin #3/4 Maintenance Lab LPS Tech & Admin.
Lost Time Cases
MO. YTD
00 00 00 00 00
Lost Work Cases
MO. YTD
00 00 00 00 00
Recordable
Cases
MO.
YTD
00 00 00 00 00
First Aid Cases
MO. YTD
2 24 02 00 01 00
Total PVC
0 0 0 0 0 0 2 27
/bsf
D. R. Muehlenbrock
OCC 11623