Document XO2Roy2Ez0J42yGw6NBxOoo4y

yv UJU D.P- Diamond Shamrock Interoffice Correspondence To: From: Date: V. F. Pisani D. R. Muehlenbrock December 14, 1983 7m_________ ^ 7f2 / 1 'i* Subject: Safety, Environmental and VCM Reduction Report - November, 1983 L D 118-D cc: D. E. Bli B ._hta4s"tenson7L ms /R. Stannard - GCA Henderson/G. Clark - ^aTety D. C. Parkhill G. 0. Rabbe - EC J. Worthington - Dallas D. P. Tech File - 16.03B (2) I. Personnel VCM Exposure Personnel sampling during the month is summarized in this section of the report. There was one TWA value recorded during the month which was abov 1 ppm.* On November 22, an operator at #3 plant was exposed to 1.01 ppm w dropping polys. Records indicate respiratory protective equipment was wc during the sampling period. TWA EXPOSURE (PPM) Department Resin LPS Lab Maintenance Tech., Adm., & Plant Overall Plant High 1.01 0.49 0.40 0.75 0.36 1.01 Low 0.03 0.15 0.30 0.22 0.05 0.03 Average 0.37 0.30 0.35 0.40 ~U721 0.33 Samples 5 4 2 6 4 21 Residuals Product PVC 426 PVC 450 PVC 470 PVC 500 Exp. & 0G Resins High 37.79 5.79 7.38 73.94 32.79 Low 0.20 0.02 0.06 0.05 0.74 Average 8.30 1.27 1.66 7.39 13.95 Samples- 12 10 11 53 4 OCC 11620 Safety, Environmental and VCM Reduction Report - November, 1983 Page 2 III* Environmental Air f .... A. Leak Patrol There were a total of 677 points checked and there were two new leaks detected. Both of the new leaks were fixed, leaving no leaks still needing repair at month's end. B. There were no reportable VCM releases during the month. C. There were no reactor openings above the standard during the month. IV. Environmental Water i A. The highest level of VCM recorded for any of the process water sewers during the month was 9.79 ppm. This was the effluent from the No. 1-4 Plant Sump. The highest level of VCM in the storm sewers was 0.05 ppm. B. There were no violations at No. 004 Outfall during the month. C. Wastewater Stripping There were no violations of the 10 ppm standard during the month. V. Reclaim System/Flare Flare Use in Hours ^Permit year is 2/1 to 2/1. Month 0 Permit Y-T-D* 8 Hr. 45 Min. VI. Environmental Statistics A. Suspension Stripping Daily Average (ppm) Days Above Standard Limits B. Wastewater Stripping Daily Average (ppm) Days Above Standard Month 88.3 0 Month 1.36 0 Y-T-D 69.2 2 Y-T-D 1.41 7 OCC 11621 Safety, Environmental and VCM Reduction Report - November, 1983 Page 3 C. Reactor Openings Number of Charges Number of Reactors Sampled Number of Above Standard Limits Percent Above Standard Limits Charges/Openings 1,689 24 0 0 1/1 Total Reportable VCM Releases Number of Releases 0 E. Outfall 004 Number of Samples Above NPDES Permit 0 18,350 253 6 2.4 1/1 2 ,3 VII. Total VCM Emissions from Stripping and Reactor Openings Suspension Resin Stripping Month Y-T-D EPA Permitted Emissions - lbs. *Texas Permitted Emissions - lbs. Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas) 4,430 1,329 978 (351) 48,150 14,445 8,381 (6,064) ^Permitted based on 280 MM Ib/yr. production by State of Texas (allowable residual @ 120 ppm). Reactor Openings Permitted VCM Emissions - lbs. Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas) 221 157 (64) 2,406 1,951 (455) Totals EPA Permitted Emissions - lbs. Texas Permitted Emissions - lbs. Actual VCM Emissions - lbs. Over/(Under) - lbs. (Texas) % of Permitted Emissions (Texas) 4,651 1,550 1,135 (415) 73.2 50,556 16,781 10,332 (6,449) 61.6 OCC 11622 Safety, Environmental and VCM Reduction Report - November, 1983 Page 4 MUU Injury Report Resin #3/4 Maintenance Lab LPS Tech & Admin. Lost Time Cases MO. YTD 00 00 00 00 00 Lost Work Cases MO. YTD 00 00 00 00 00 Recordable Cases MO. YTD 00 00 00 00 00 First Aid Cases MO. YTD 2 24 02 00 01 00 Total PVC 0 0 0 0 0 0 2 27 /bsf D. R. Muehlenbrock OCC 11623