Document XLdy9kvMRN2kNNYX0ym1GRby

Operation Report Dept. 246 - Aroclor March - 1965 PRODUCTION SUMMARY (Current Month) Scheduled - 2,480,000# Actual - - 2,489,050# # of Schedule - 100# PRODUCTION SUMMARY (year to date) Aroclor Current Month 1242 1248 1254 1260 1262 Total - 1,065,365# 475,013# 469,588# 454,844# 24,240# 2,489,050# Year to Date 2,828,872# 1,936,428# 1,527,952# 1,210,166# 35,820# 7,539,238# : Average Monthly Production - 2,513*079# Availabilities Repair - 89.78# Total - 80.91# ... Process - 94.62# . Other - 96.51# The reasons for the outages for this month are summarized below. Repair 34 Hrs. . (4.57#) Rate of No. 1 still reduced because of broken condenser (This was repaired on 3/22/65) 10 Hrs. (1.34#) Fuse burned out on filter pump. ' 17 Hrs. (2.28#) Change #2 still pump. 15 Hrs. (2.02#) (3 Hr.) Plastic cover was left on a replacement valve on #4 chlorinator. (2 Hr.) Leaking tee in off-gas line on #4 chlorinator, (3 Hr.) Leaking flange on #2 still coil (1 Hr.) Replace wiring on biphenyl transfer pump motoi (6 Hr.) Repair leak In 200# steam line. Process 9 Hrs. (1,21#) Rate of No. 1 still reduced by plugged condenser on water side. 6 Hrs. (o.8l#) Operating error. Wrong chlorinator pumped into blow tank. 11 Hrs. (1.48#) Circulating line plugged on #1 still. 7 Hrs. (94#) (3 Hrs.) (4 Hrs.) Operating error delayed chlorinator. Changed plugged furnace furnace. charging No. 4 coil on No. 2 still ........................ DSW 296462 STLCOPCB4066406 A / Dept, 246 (cont.) 2- - Other 18 Hrs. (2.42$) 8 Hrs. (1.073*) Changing products (l hr.) - Project group installing line between stills. (5 hrs.)- Plant tests on quality (2 hrs.)- No biphenyl due to late switching. YIELDS $ Theory on Biphenyl - Standard 95.50$ Actual 96.76$ YTD 96.79$ Significant Items This Month This month's production was second only to January's record production. Quality Two lots of electrical grade 1242 Aroclor were produced this month with thermal-chemical stabilities of 0.34 ppm and 0.55 ppm. The distillate from the stills at the end of each 1242 run was kept separate. The material with the 0.55 ppm stability was made during a plant test in which the two stills were run in series. The material was fed to the first still where a 10$ cut was made and then the other 90$ was sent to the second still which was operated in the usual manner. The test was run to determine if low boilers could be removed in the first still and improve the thermal-chemical stability. Although some low boilers were removed in this manner the stability for this run was actually worse than for the regular run. This could have been due to factors at other steps which affect quality. The cause for the O.55 ppm is being investigated by the Process Research Group and Technical Services. The 1242 thermal-chemical stabilities are summarized below for the first quarter of 1965* Date Lot No. Thermal-Chemical Stability 1-9-65 KE-401 0.62 ppm 1-21-65 KE-405 0.48 ppm 1-27-65 KE-4o6 0.52 ppm 2-5-65 KE-407 0.46 ppm -g=z-65 2-25-55 KE-409 -KE-412--------------- 0.52 ppm 0.44 ppm ... 2-27-65 KE-413 0.28 ppm 3-15-65 ke-4i6 0.34 ppm 4-2-65 KE-420 0.55 ppm H-n VP- Hvl o,Ho TP* Beginning with Lot KE-412 all 1242 was produced by separating the dis- tillate near the end of the run for non-electrical material, and the sensing points for the vacuum controllers on the still systems were changed from the receivers to the stills. H-Li Ot Z pp h7 DSW 296463 STLCOPCB4066407 Dept. 246 (cont.) 3- The back pressure on the HC1 off-gas line was erratic near the end of the month making it necessary to sewer HC1 gas for about eight hours. The fluctuation in back pressure is not indicative of a plugged line, but indicates that the automatic valve which distributes gas between Depts. 217 and F-218 may be causing the back pressure. The nuclear density gauge on No. 4 chlorinator was standardized and gauge readings compared with hydrometer readings. There is a large difference between the two readings which prevents the use of the density gauge as an indication of when a batch is finished. Stock Position Product Aroclor 1st of Mo. Last of Mo. Whse. Stock 1,575,018# 1,566,205# \ Dept. Stock 842,191 607,307 2,417,209# 2,173,512# ghw D. E. Harris f' DSW 296464 STLCOPCB4066408