Reprinted from CHEMICAL ENGINEERING PROGRESS, May 1963
CEP feature
High temperature
heating media
niininuimniiaimnai
Therminol FR-2 heat transfer systems
Engineering design data are given for the design of high temperature systems using chlorinated biphenyls.
Therminol fr-2 is a mixture of
chlorinated biphenyls used as a heat transfer fluid to a maximum bulk temperature of 600F because of its excellent thermal stability, fire-resist ance, and high boiling point The fluid was previously designated Aroclor 1248. Physical properties of this heat transfer fluid are given in Table 1.
Thermal stability
When Therminol FR-2 is heated ibove 600F, the fluid forms polymers of chlorinated biphenyl with the liber ation of gaseous HC1. The higher molecular weight polymers are mod erately soluble in the fluid, and the only measure of thermal degradation is the increased viscosity. Figure 1 shows the results of static thermal stability tests carried ont under isothermal conditions.
W. J. Davis and P. G. Benignus Monsanto Chemical Co.
St. Louis, Mo.
The polymer formation was found
to be first order following Equation 1
until the viscosity increased from 20
centipoises to 30 centipoises measured
at 130F.
log (Ve/Vt) = 0.434 K,t
(1)
Using Equation 1 together with the
experimental rate constants, the inter
mediate viscosity curves for other tem
peratures were plotted on Figure 1.
When the calculated values deviated
from the experimental curves, inter
mediate values determined from special
cross-plots were used to smooth die
curves.
CHEMICAL ENGINEERING PROGRESS, (Vol. 59, No. S)
DSW 433897
May 1963
39
STLCOPCB4087003
The equivalent cold plane surface aAep is the product of a plane A^ replacing the heater tube bank and an effectiveness factor which is the ratio of radiation reception by the actual tube surface to the reception by the continuous plane. A plot of a based on data by Hottel is presented in Mc Adams^).
Figure 1. Effect of temperature and time on the viscosity of Therminol FR-2.
When fluid bulk or film tempera tures exceed 630F, the fluid viscosity increases rapidly with temperature. In a properly designed commercial heater operating at a bulk temperature of 600F, with film temperatures below 630-640F, the over-all rate of poly mer formation is extremely low. This conclusion is substantiated from field results of several operating heaters.
Heater study
A field study of several Therminol heaters was made to establish engineer ing design data such as allowable heat fluxes, maximum film temperatures, fluid stability rates, etc. The test heat ers included ones where tube failures occurred shortly after startup and heat ers which had been in successful oper ation for a number of years.
The Lobo and Evans (I) method seemed most applicable to evaluate heater performance since it had al ready been used to test many heaters. The method was based on the Stephan-Boltzmann equation and previous ly published data by Hottel and co-workers (2, 3). More rigorous methods published prior to 1958 ap peared too rigorous for easy applica tion and the rough data available did not justify a more rigorous approach. A method was needed to distinguish between a heater which would operate satisfactorily and one which would be a problem, even though the method was empirical.
Equation 2 is the Stephan-Boltzmann equation used by Lobo and Evans with an added convection term.
is dependent upon the flame emissivity, eF, and the ratio of the effective refractory surface An (total refractory surface A( less aAcp) and the equivalent cold plane surface aAcp. Lobo and Evans presented a <f> factor plot in their article.
Flame emissivity eF has been de fined by Hottel (4) as:
tp = U0 -- ao(Ts/Tg4]/
[1 - (TB/Ta)*]
(3)
Values of the combustion gas emissivities and absoiptivities can be obtained from radiation charts (4) for C02 and HzO.
Maximum heat flux
Equation 2 together with the over all heat balance, Equation 4, can be solved for the maximum heat flux
Qa/aAcp by assuming values for Ta until Equation 4 is satisfied. Assume 2% of the heat input as losses.
Q (Input) = Qa (Absorbed) +
Q0( Exhaust Gases ) + QL
(Heat Losses)
(4)
In applying the previous equations to evaluate the field test heaters, a trial value for Q(input) was assumed. If the calculated absorption rate did not agree with the actual rate within 1% after Equations 1 through 4 were satisfied, a new value for Q(input) was used until the calculated and the actual duties were equal. This pro cedure yielded values for T0 and QJ aAcp maximum. Heater efficiency esti mated by this procedure is incorrect due to the basic assumption that the radiating gas temperature T0 is uni form throughout the heater. The final value of Tg must be adjusted by sub tracting 200 to 250F to T0 for esti mating the heat content of the com bustion gases leaving the heater (5).
Qa = 0.173^ [(To/100)<(r,/ioo)]Av + hcA(T0 -- Ts)
(2) A Therminol FR-2 high temperature heater installation.
DSW 433898
40 May 1963
CHEMICAL ENGINEERING PROGRESS, (Vol. 59, No. 5)
STLCOPCB4087004
CEP feature
Maximum film temperatures were estimated by calculating the outside fluid heat transfer coefficient using Equations 5 and 6 and solving Equaton 7 for the temperature of the film,
r,.
fcA/*=0.027 (Dfit/fi)0 *
(5) (6)
QiJa ^cp = (?M)mo = h<o A T =
K{T,-Tb)
(7)
Table 2 is a summary of the data obtained on several of the test heaters. The tubes in units 1 through 4 burned out shortly after startup. The calcu lated film temperatures in each case were approximately 700F. Inspection of Figure 1 shows that the fluid de composition rate at 700F temperature is very rapid. High polymeric tars rapidly form which settle out and cause blockage of orifices, control valves, headers, etc., and eventual tube failures.
Units 5 through 17 represent heat ers which have been in successful operation for the number of years des ignated and where the fluid is still the original charge. In each case the esti mated film temperatures were 640F or less which correlates very well with the thermal stability data on Figure 1.
Cylindrical heaters
Lobo and Evans' method was based
on the well-stirred furnace chamber model. Kern (6) recommended that in applying the method to cylindrical heaters that the unit be zoned with a maximum zone length of 1.5 coil diameters.
It can be shown that calculated flux rates are much higher in the lower half of a cylindrical heater if the unit is zoned rather than treating it as an isothermal single zone. For this reason each of the cylindrical heaters in the
study were analyzed with both single zoned and multi-zoned calculations to determine the film temperatures. The majority of the film temperatures cal culated using a lower zone L/D of 2 agreed with the fluid life data and with comparable results obtained in box heaters. When film temperatures ap
proached or exceeded 700F, tube burn-out or severe fluid damage oc curred. Excellent fluid life was ex perienced in heaters where the film temperatures were below 640F.
The design of a liquid heating sys tem can be broken down into two major parts. These are: 1. heater de sign, and 2. system design.
Heater design
There have been two types of heaters used for Therminol FR-2 serv ice. These are the floor-fired cylin drical heater and the box heater. Each is of the forced-circulation type; natural circulation heaters should not be used because of the non-boiling characteristics of the fluid. Forced circulation provides positive fluid cir culation for controlling the film tem perature of the fluid near the coil surface.
A single coil heater is preferred to the multi-pass heater from the stand point of positive circulation. How ever, by proper design of the multi tube units to assure uniform distri bution of liquid flow, excellent per formance can be obtained. In many cases pressure drop across the unit must be low and multipass tube ar rangements even in cylindrical heaters must be used.
The use of a convection section in creases the heater efficiency from 60 652 to 75-78%, depending upon the design. Although the initial cost of the heater is significantly higher with the added convection section, usually the fuel savings yields a short write
A
i A|
VENT I TANK 1
3] PURGE
LINE
l
!l
i
!
] USER SYSTEM
a1J| _jlVy -
1 SECONDARY LOOP
U/"H
COOLING PUHP
--Ah
FLUID 1 COOLER CV
'
I1!-1. :
** : rd
HAW LOOP
< LOOP . CONNECTOR
FUEL ~rrw,
|----------
pump
---------------------------
(Xpn--
Figure 2. Typical system for heating and cooling cycles with Therminol FR-2.
High temperature
heating media
off period. In many cases where a convection section is being used, it is advantageous to introduce the cold fluid into the radiant coil rather than to use the conventional countercurrent flow pattern. The AT across the coil is usually 60F or less and with a maximum fluid limit of 600F, little efficiency will be lost due to the re duced temperature approach. How ever, the effect is significant in the radiant section, because lower bulk temperatures permit higher heat fluxes to maintain Hie maximum film tem perature. Where excessive decomposi tion is occurring in existing heaters, reversing the fluid in this manner would be most beneficial with very little cost involved.
The Lobo-Evans' method (1) al ready discussed, can be used for rat ing heater designs. The maximum allowable film temperature recom mended is 640F based on the max imum flux rate (Q/aACp) determined by the method. Cylindrical heaters should be treated with a 2-zone cal culation (6) with the length of the lower zone equal to 2D. The zone calculation results in slightly higher coil areas to allow for uneven tem perature distribution in the heater and is not representative of actual thermal conditions. Box heaters can be treated with a single-zone calculation.
Burner selection
The type of burner to be used should be carefully selected by the designer. It has been found that the low pressure combination oil-gas forced draft unit is the most satisfac tory unit both from design and opera tional considerations. The initial cost is many more times that of the high pressure, natural induced type, but the advantages of better temperature control due to its higher turn-down ratio can readily be seen, especially when the heat load fluctuates widely. Most forced drafts units operate at turn-down ratios of 9:1 compared to 4:1 for the induced type. Since each application differs, it should be re membered that the burner is an im portant component of the system and should be carefully selected for the particular application.
CHEMICAL ENGINEERING PROGRESS, (Vol. 59, No. 5)
DSW 433899
May 1963
41
STLCOPCB4087005
System design
.. . ...
flow rate through the heater. It is
Figure 2 illustrates a typical heat
ing system. Major items are the heater,
circulating pump, vent tank, primary
and secondary loops, and control in
strumentation.
The circulating pumps should be
high temperature continuous duty
steel centrifugal-type pumps. The
C should be installed near the ` at floor level for easy main
B or cooling water in the same jacket
tenance accessibility. Either indooroor rcoil.
outside installations can be used.
The main circulating loop supplies
The vent tank can be sized either hot fluid to the users and returns the
to allow for system expansion or to cold fluid to the heater. It is not
contain the entire charge of fluid. It recommended even in small installa
can be fabricated from mild steel and tions that the users be placed in series
should be insulated to prevent con with the loop. Always install the user
densation of water vapors and HC1 in parallel or provide a by-pass around
above the liquid level. A 1-in. surge the user.
line should be installed connecting
Direct fired heaters are usually pro
the high temperature-high pressure vided with instrumentation to obtain:
side of the main circulating loop to 1. adequate operational control and 2.
the vent tank as shown in Figure 2. safety controls which will satisfy Fac
Hot fluid should be recirculated to tory Insurance Association (FIA) ap
the vent tank (above liquid level) con proval for direct-fired heaters.
tinuously or intermittently to remove
Figure 2 shows the fluid tempera
traces of water and HC1. Caution ture-controller output regulating the
should be exercised never to use fuel supply and the flow by-pass con
Therminol intermittently with steam troller which maintains the design
strongly recommended that the by pass control valve be installed close to the furnace to minimize time lags and excessive pressure drop in the loop piping. The recirculation rate through the heater does not necessar ily have to be the same as through the piping system; in most cases, it is larger. These two controllers are the most important portion of the in strument package to assure troublefree heater performance.
A booklet on good practices has been published by the FIA (7). Ap proval by FIA is usually obtained during the design stage of any directfired heater installation.
ACKNOWLEDGMENTS
The authors wish to extend their personal gratitude to Monsanto Chem ical Co. for their permission to pre sent these data. They particularly wish to thank A. M. Ellenburg and H. D. Bamstarflf for their much ap preciated data on thermal stability.
Notation
A--area, sq. ft. C--fluid specific heat, Btu/lb.-F.
Table 1. Physical properties of Therminol FR-2.
D--diameter, ft. G--mass flow rate, lb./hr.-sq-ft.
Temp., *F
100 150 200 250 800 350 400 450 500 550 600
Thermal
Sp. ht.,
Conductivity,
Btu/lb.-F* 1 11 Btu/hr.-F-ft.
0.281 0.289 0.297 0.305 0.313 0.321 0.329 0.837 0.388 0.341 0.349
0.0585 0.0580 0.0579 0.0575 0.0570 0.0566 0.0560 0.0555 0.0549 0.0542 0.0536
Density, lb./gal.
12.00 11.75 11.63 11.29 11.06 10.83 10.60 10.37 10.14 9.90 9.67
Viscosity, cp.
62.4 11.50 4.95 2.87 1.87 1.32 0.99 0.78 0.63 0.53 0.45
rate constant. he--convective heat transfer coefficient,
Btu/hr.-F-sq.-ft. tube-side fluid heat transfer coeffi cient, Btu/hr.-F-sq.-ft. tube-side fluid heat transfer coeffi cient based on out-side tube area, Btu/hr.-F-sq.-ft. k--fluid thermal conductivity, Btu/hr.F-ft. /--time, hr. Ta~temperature of the combustion gases, R.
Tg--tube wall temperature, R.
Table 2. Therminol FR-2 field heater study.
V0--initial fluid viscosity, cp. Vt--fluid viscosity at time (/), cp.
Unit
1 2 S 4 5 6 7 8 9 10 11 12 13 14 15 16 17 B. O.
Capacity, Btu/hr.
6,000,000 20,000,000 5,000,000 8,000,000 6,000,000 2,000,000 1,000,000 3,000,000 6,000,000 10,000,000 5,000,000 3,000,000 1,500,000 3,000,000 3,000,000 6,000,000 9,000,000
Bulk temp.
600 600 430 600 600 600 530 650 585 475 550 650 600 570 635 600 590
Flux btu/hb.-sq. ft.
Max. Avg.
19,200 9,950 22,400 10,000 21,400 13,700 18,350 7,650 19,200 9,950 48,800 20,000 7,400 3,600 12,900 6,700 17,850 9,300 23,300 13,200 21,400 11,600 18,350 7,550 10,000 6,400 19,150 9,950 27,400 17,800 19,600 12,500
Max.
film
TEMP* *F
696 705 694 726 640 675 593 627 631 573 631 640 635 640 595 656 646
Fluid VELOCITY nr./sec.
* 3.9
3.9 1.6 6.0 7.8 8.6 2.5 8.8 10.3 3.2 4.0 6.7 5.8 8.0 12 9.7 6.0
Fluid life TO
DATE, YR.
B.O. B.O. B.O. B.O.
4 7 11 8 4 4 7 8 6 5 2 2 1
Greek letters
.
to--gas emissivity. fir-fluid viscosity, lb./hr,-ft. ^-over-all furnace emissivity.
LITERATURE CITED
I. Lobo, W. E., and J. F. Evans, Tran. Am. Intt. Chem, Engra. 55, p. 748-78 (1989).
2. Hottel, H. C., Trane. Am. Inst. Cham. Engra., 18, p. 178 (1927).
8. Hottel, H. C., Tran*. Am. Soc. Mach. Engra., 68, (14), p. 26S (1981).
4. McAdams, W. H., "Heat Transmission,*' McGraw-Hill Book Co., 2nd Ed. p. 70 (1942).
5. Hottel, H. C., J. Inst. Fual, p. 220-284 (1961).
6. Kern, D. Q.. "Process Heat Transfer," Mc Graw-Hill Book Go., 1st Ed. (1950).
7. "Recommended good practice for heat transfer mediums in closed systems/' Fac tory Insurance Association, Chicago, HL (June. 1964).