bcc C. Paton/D. E. Roush P. W. aann 1070 H. R. Ford 1070 C. L. Clay January 10, 1972 western Electric 801 Merritt Drive Dept. 317130 Oreensboro, n.C. 27^*07 Attention Mr. Bill Cox Dear Mr. Cox: Enclosed la our literature ooverlng Thermlnol 53 heat transfer fluid as a replacement for Thermlnol PR-1. We suggest that you drain all the Thermlnol PR-1 from the sys tem and refill with Thermlnol 55. Operate the system at tem perature for a oouple of weeks to thoroughly flush the Inner surfaces of the system and again drain all this flushing fluid. Both the used PR-1 and flushing fluid should be returned to use freight colleot for disposal. Then refill with a new charge of Thermlnol 55. Labels are enolosed that can be affixed to the drums for the return of the fluid to our Sauget, 111. plant. We would suggest that oontact be made with your safety depart ment and insuring company regarding fire protective devices for your system since Thermlnol 55 Is not fire resistant. We would also suggest the use of either an Inert gas blanket or a oold seal as outlined In the enclosed bulletin to prevent air oontact and oxidation. Orders for Thermlnol 55 can be plaoed by calling toll free 800-325-3850. In quantities of 5-39 drums the price Is $.975/ gallon POB Alvin, Texas. Please call If you have any questions. Sincerely, MQNS 092323 J. J. Roder Produot Supervisor os Heat Transfer Plulds