November 21, 1972
PCB ANALYSIS OP H.D.P.E. BOTTLES
" R. E. Keller - TIB -----J. C. Landes - C3SA W. B. Papageorge - B2NA C. R. Schrock - C2SE
E. S. Tucker - T2F
R. L. Maute Texas City - 1890
S-P
As requested in our phone conversation this morning, I have enclosed copies of my 11-9-72 memo to W. B. Papageorge and the chromatograms from the analysis of the H.D.P.E. bottles for PCBs. In addition, you will find a copy of our Analytical Chemistry Method No. 71-35.
I am sure you will agree the chromatograms clearly indicate
the presence of PCBs in the bottles. Nevertheless, the
.
amount found is a factor of 16 below the proposed FDA guide
line of 5 ppm.
'
If we can be of any further assistance to you in tracing the source of the PCBs in the bottles, please feel free to contact us.
db Enel.
U/,
H. M. Mees
im.i fttv. li es