Johns-Manville
5
onxoiu.o
|
NO. 3000* 4000,5000 & 0000 l
LOW COST, HIGH TEMPERATURE ASBESTOS ELECTRICAL INSULATION FOR SAFE, LONG-LIFE EQUIPMENT DESIGN.
DESCRIPTION
Quinorgo Electrical Insulations are high temperature di electric papers available in a thickness range from 3 to 15 mils. Principally inorganic, they contain over 80% selected Canadian Chrysotile asbestos fibers. Selected organic bind ers are added to impart specific product features. Different styles vary in stiffness, stretch, saturability and other phy sical properties. All types are noted for outstanding retention of dielectric strength after long term exposure to high oper ating temperatures. Low cost and excellent performance in electrical apparatus and related service have made Quinorgo an industry standard of recognized quality.
NO. 3000 & 4000 QUINORGO
These heat resistant dielectric sheet materials contain over 83% specially processed, highly purified asbestos fiber. A unique treating process leaves the asbestos fibers free of dirt, dust and water soluble electrolytes. These two Quinorgo in sulations may be readily treated or combined with organic or inorganic reinforcing materials such as glass cloth or plastic film. No. 3000 Quinorgo is absorbent, especially in the thinner calipers. This permits thorough impregnation with any of the various resins, varnishes or fluid dielectrics in use today. No. 4000 Quinorgo is practically identical to No. 3000 except that it contains about 3% resin added to reduce its absorption and penetration characteristics. This combination provides ao ideal laminating materiaL One sur face may be coated with shellac or varnish to permit bonding or cementing to inorganic woven cloth, mica or organic films. The bonding coat that is applied does not tend to strike through to the other side. Thus, the untreated surface is left ready to absorb the varnishes used in further process ing of equipment.
NO. 5000 QUINORGO
This is a thin, flexible, heat-resistant electrical insulation composed of purified asbestos fiber and a small amount of high temperature rubber binder. The sheet is formed by a special fiber cleaning and wet felting process. This results in a thin, tightly matted and highly uniform material. Ther mal stability and lasting dielectric strength are characteristic. Actual tests conducted at 200*C show no loss of dielectric strength with temperature exposure, however, binder deter ioration above 150*C is apparent under humid conditions.
No. 5000 Quinorgo may be applied "as is" or used as a base sheet for treating with a variety of resins and varnishes. It may also be combined with films and fabrics for extra strength. Because of the rubber binder, it has more resis tance to moisture than the usual untreated asbestos paper. Good stretch properties compensate for lower tensile giving an extra flexible but tough sheet. Available in a selection of thicknesses. No. 5000 Quinorgo can be supplied in tapes, cut pieces and 36" wide roils.
NO. 6000 QUINORGO
'
This newest addition to the Quinorgo product group has the lowest organic binder content (maximum 5% acrylic resin). Low in basis weight, the sheet has an open structure which makes it very easy to saturate. The minimum binder content permits highest temperature service, following proper resin treatment.
J-M and other composite insulation manufacturers combine No. 6000 with glass doth and organic Aims, in addition, manufacturers of rigid plastic laminates use this porous sheet as a substitute for glass doth and mat. It produces a plastic sheet with comparable physical characteristics plus out standing thermal and dimensional stability. Available In 5 and 7 mil thicknesses.
TEMPERATURE CLASSIFICATION AND DESIGN CONSIDERATIONS
All the different styles of Quinorgo require further treatment for optimum performance in electrical insulation systems. Treatment by varnish impregnation, unit encapsulation, or impregnation and coating are necessary to insure maximum moisture resistance. However, impregnation can be readily accomplished with suitable equipment.
Use tests and other performance data indicate that well im pregnated Quinorgo sheets assume the thermal aging char acteristics of the saturating resin. J-M initially classifies all basic Quinorgo styles as Class 130. This arbitrary classifi cation is based solely on the known temperature stability of the organic binders.
C311133J
HIJBB-0005820
*=?
U--a
0
f^1
Quinorgo turn insulation being trimmed on edge wound field coils. Dry type transformer winding using Quinorgo layer insulation.
APPLICATIONS
Electrical
Transformers, coils and reactors --layer and barrier Insulation.
Lifting magnets--turn insulation, strap wound pancake colls.
Motor field coils, edge wound coils--turn insulation (See Note
1).
Hydro generator rotor colls--turn insulation.
Bobbin colls--layer and wrapper insulation.
Electrical insulation, coaters-- base sheets for saturating and coating.
Electrical insulation composite manufacturers--film and cloth combinations (See Note 2).
Electrical laminates--base sheet for saturating and pressing, high and low pressure laminates.
Round and rectangular tubes-- transformer cores, coil cores and bobbins, cartridge fuses, control devices, reactor cores, etc. (A Hat of tube manufactur ers is available on request.)
General
Optical--lens retainer during fusing of bifocal or trifocal tens blanks.
Gaskets--high temperature.
Wentmcatlon-flre proof labels.
e Chemical service filtration.
Note 1. For Insulating/bonding applications seadata stoats onJ-M No.4S6 Quinorgo.
Notes. J-M and other leading electrical in sulation manufacturers offer a broad line of Quinterra and Quinorgo compos ites for transformer, motor, electronic and cable applications.
C31113GG
H0BB-0005821
TYPICAL TEST DATA (All tests msda attar conditioning at 23*C, 50% RJ1.)
,-=n >---*
NO. 3000 QUINORGO ,
4 5 7
10 15
S.6-4.4 4.S-5.5 6.3-7.T 9.0-11.0 13.S-16.5
1.6 7
2.1 9 3.2 11
4.3 ; 16 6.3 18
5 850 7 1100
8 1 1500
12 ; , 2000 14 : 2900
1400 1800 2400
3300
110
Less
140
than
220
1% 375
| 575
Akl I|IAIJA4#AVfiAUAAvA i 1 i
3 5 7
10 15
2.7-3.3 !
4.5-5.5 6.3-7.7 |
9.0-11.0 13.5-16.5
1.1 2.0 3.0 4.2
6.5
i__________
i
6 6 600 !
14
10 | 1100
1500 j Less
17
IS > 1600 i 1900
than
20
20
2000 ! 2400
1%
23 ! 25
2900 j 3300 .
110 190 350 600
900
!
;1 34
27-3.3 3.6-4.4 1
1.2 1.4 7 17 1 2.2 1 8
NO. 5000 i
5
4.S-5.5
2.3
3.5
8
QUINORGO i
7
6.3-77
3.5
5.0 11
l 10
9.0-11.0
4.9
6.5 13
; 15
13.5-16.5,
7.3
7.5 15
550 750 1000 1500 2200
3100
650 850 1110 1850 2500 3450
I | : 1
i
5.0
6.0 10 6.5 18 6.0 39 5.0 ! 60
4.0 j 136
ii
NO. 6000 ;
5
4.5-5.5
1.5
2
4 950 1200 1.5
QUINORGO , 1
7
6.3-77
2.3
3
5
; ]
1200
| 1400 !
15
ELECTRICAL PROPERTIES AFTER AGING (Typical average laboratory test values--nottor specification)
Dielectric Strength, Volts/Mil, Standard Com.
Dielectric Strength Retained, After 168 Hrs. at 175*C
Dielectric Strength Retained, After 168 Mrs. at 200*C
230 250 240 95% 95% 100%
- 102%
Dielectric Constant, 60 CPS. Standard Ccnd.
Dielectric Constant, After 168 Hrs.at17S*C
Dielectric Constant, After 168 Hrs. at 200*C
8.9 8.7 15.1 9.0 4.8 3.9 - - 3.5
Dissipation Factor, 60 CPS, Standard Cond.
Dissipation Factor, 60 CPS, After 188 Hrs. at 17S*C
Dissipation Factor, 80 CPS, After 168 Mrs. at 200*C
.35 .27 .82 .42 .20 - - .17
Volume Resistivity, OHM-CM, Stand. 3.5x10* 2.9x10* 2.1x10*
`COMSCTtONlMQ; Sttn4r4-CoMKI9<*4 40 Jw*./*C/S0 RH OtoWeiric Strength tt4fl t Aging ttmpertter*. OtoMctric ConUf>t 4M DiMipatlen Factor Wttrt at SUnOard.
210 105% 108%
20.3 4.1 6.5
.89
.39 1.5x10*
TEST METHODS
C*//per--TAPPl,T-441 (RettMeth od) or ASTM 0*374 Method C
Breaking Load, BurstingStrength, Stretch--ASTM 0*202
Clark Stiffness--TAPPl T-451
Dielectric Strength-ASTU 0*149 (short tints tost mttttod) using 2" dlamstsr brass slsctrodss at IS psi in air. Ths minimum Dielectric Breakdown Strsngth of ths matorial is ths loweat average valus for any intfitriduef lotThs average Oislsctric Brsakdown Strsngth is ths normal quafltjr level which ths matsrial will average.
Volume Resistivity--ASTU 0*257
Dielectric Constant t Dissipation Factor--A8TM 0*190
Not*:
These insulations may be stocked over long periods without deterioration. Being natu rally porous, however, they should be either maintained in a dry or heated storage space or should be dried before impregnation. When rolls of these materials have been impregnated or treated before storage, they should be given a slight drying cycle be fore using. This drying would depend upon the known protective ability of tne particu
lar varnish used and efficiency of the storage facilities to preclude moisture absorption.
C3111307
HWB8-BBB5818
u"""
>
Charles B. Yuill
Sale# Representative
Electrical Insulation Industrial Products Division
Johns-Manvflle
Sales Corporation
P. 0. Box 517 Toledo. Ohio 43693 (412) 922-2206
Home: R. D. *1 Claysville. Pa. 1S323 (412) 948-3737
03111304
f7=5T