Document X8RVBEKYwY2Eavb0j0OrXR0g
Monsanto
Ga/WT^T'7 -0
MONSANTO INDUSTRIAL CHEMICALS CO800 N. Lindbergh Boulevard St. Louis, Missouri 631S6 Phone: (3U) 634-1000
October 24, 1975
Dr. Robert A. Stenger General Electric Co. John Street Hudson Falls, N.Y. 12839
Dear Bob:
I just received your 10-17-75 letter posing two questions about our recent analyses of water for PCBs. Regarding the first question about the two values we obtained on the Ft. Edward bridge sample, we feel confident that the lower value is more accurate. In my 10-16-75 letter to you, I did not include the higher value. As I indicated during our phone conversation, we feel the higher value was in error because of cross contamination from water sample "B" sent to Dr. Crow. We were unaware of the very high (3200 ppb) concentration of PCB in "B" and did not take special precautions to prevent PCB migration through lab air, which probably contaminated nearby samples concurrently being extracted. This emphasizes the care which must be exercised when sampling and analyzing for ppb levels of PCBs in the presence of potential sources of contamination.
As a matter of principle when analyzing for PCBs, we always use multiple (3) extractions on unfiltered water. We also extract (rinse) the container thoroughly. These precautions help insure accurate sampling and analysis. Woodson-Tenent Laboratories assure us that they also follow these procedures, as outlined in ASTM Method D 3304.
I hope this answers your questions.
Sincerely
ss
bcc: W. C. Hammann R. E. Keller W. B. Papageorge
Dr. James P. Mieure Research Group Leader
W. R. Richard J. C. Weber D. Wood
MONS 093504
unit Of Momii Company