Document X7ybOLzg9E9Ved3adN4M20MZ4
506
CHAPTER 22
1950 Guide
Table 5. Ratings fob Cast-Iron Radiant Baseboard
Rating in Btc per Linear Foot
Ttpe and Height
Radiator Temperature--Fahrenheit
215 210 205 200 195 190 185 180 175
Type R, Low height................. 300 285 271 257 245 231 219 206 * 194 Type R, High height................ 425 404 384 365 347 328 310 292 274 Type RC. Low height.............. 500 475 452 429 408 385 365 344 323 Type RC. High height............. 700 605 633 601 572 640 610 481 . 452
170
182 258 304 426
sure! for their heat output. Cast-iron radiant baseboards may be either
(1) a full radiant, called Type R, or (2) a radiant convector, called Type
RC. The Type RC unit, in addition to the radiant front face, has ex
tended convection heating surface on the rear face to increase its output.
The convector type of baseboards includes finned tube units with which
enclosures are used. The front of the enclosure supplies radiant heat.
Advantages claimed for baseboard radiators are: They are inconspic
uous; they are clean in operation; they offer a minimum of interference
with furniture placement, and, they distribute the heat near the floor.
This last characteristic reduces the floor to ceiling temperature gradient
to about 2 F deg and tends to produce uniform temperatures throughout
the room. It also makes baseboard radiators especially adaptable to base
mentless homes, where cold floors, are prevalent.*
Heat loss calculations for baseboard heating systems are the same as
those used for other types of radiation. The procedure for designing
baseboard heating systems is given in I-B-R Installation Guide No. 5.1
Ratings for baseboard radiation are expressed in Btu per linear foot:
The ratings for cast-iron baseboard units have been standardized1 and are
given in Table 5. Ratings of finned-tube units are listed in manufacturers'
catalogs:
.
* Pipe coils are assemblies of standard pipe or tubing (1 in. to 2 in.) which
are used as radiators.. In older practice these coils were commonly used
in factory buildings, but are not often found in this service today. When
coils are used, the miter type assembly is preferable, as it readily permits
expansion in the pipe.
The heat emission of pipe coils placed vertically on a wall, with the pipes
horizontal, is given in Table 6, which has been developed from available
data and does not represent definite results of tests. For such coils the
heat emission varies as the height of the coil. The heat emission of each
Table 6. Heat Emission of Pipe Coils Placed Vertically on. a Wall (Pipes Horizontal) Containing Steam at 215 F and Surrounded with Air at 70 F
Btu -per linear foot of coil per hour (not linear feet, of pipe)-
Sox or Pipe
Single row________ ___ ___________
Twa_ ..
__ ___ __
Four__
. --------
-------
Sit
RtphL. ______ _ _____ __________ ____
Twelve_____________________ __ ___
1 In.
132 252 440 567 651 732 . . 812
IKI.
162 312 545 702 796 907 1005
1141s.
- 185 348 616 793 907 1020 1135
1 1 i
I
Radiators and Convectors
507
pipe of ceiling coils, placed horizontally, is about 126 Btu, 156 Btu, and
175 Btu per linear foot of pipe, respectively, for l-in., lj-in., and l j-in. coils.
CONVECTORS
Convectors are space heating devices composed of a casing with outlet grille, and an extended surface heating element of fin-tube or cast-iron fin surface. The casing usually contains a damper. The air enters the en closure near the floor line below the heating element, is heated in passing through the element and delivered to the room through the outlet grille located near the top of the enclosure. The room air movement thus established accomplishes a reduction in floor to ceiling temperature dif ferential and tends to assure comfort in the living zone. A typical re cessed convector is shown in Fig. 1. Factory-assembled units comprised of a heating element, casing and outlet grille with damper are widely used. Grilles may be used over the air inlets.
In cases where enclosure's are to be used but are not furnished by the heater manufacturer, it is important that the proportions of the cabinet and the grilles be so designed that they will not impair the performance of the assembled convector. It is desirable, that the enclosure1 or housing for the convector fit as snugly as possible so that the. air to be heated cannot by-pass, the heating element in passing through the enclosure.
Gast-iron heating units may be concealed in a cabinet or enclosure for appearance. In such cases a greater percentage of heat is conveyed to the room by convection thereby resulting in a form of gravity convector.
The output of a convector, for any given length and depth, is a function of the height of the discharge grille above the heating element. Therefore, the published ratings are generally given, in terms of square feet of Equiv alent Direct Radiation, EDR. For steam convectors, as for radiators, 240 Btu per hr may be taken as an equivalent square foot of radiation. When more than one heating unit is used, one mounted above the other in -the same cabinet, the output of the upper unit, or units will be materially less than that of the bottom unit..