506 CHAPTER 22 1950 Guide Table 5. Ratings fob Cast-Iron Radiant Baseboard Rating in Btc per Linear Foot Ttpe and Height Radiator Temperature--Fahrenheit 215 210 205 200 195 190 185 180 175 Type R, Low height................. 300 285 271 257 245 231 219 206 * 194 Type R, High height................ 425 404 384 365 347 328 310 292 274 Type RC. Low height.............. 500 475 452 429 408 385 365 344 323 Type RC. High height............. 700 605 633 601 572 640 610 481 . 452 170 182 258 304 426 sure! for their heat output. Cast-iron radiant baseboards may be either (1) a full radiant, called Type R, or (2) a radiant convector, called Type RC. The Type RC unit, in addition to the radiant front face, has ex tended convection heating surface on the rear face to increase its output. The convector type of baseboards includes finned tube units with which enclosures are used. The front of the enclosure supplies radiant heat. Advantages claimed for baseboard radiators are: They are inconspic uous; they are clean in operation; they offer a minimum of interference with furniture placement, and, they distribute the heat near the floor. This last characteristic reduces the floor to ceiling temperature gradient to about 2 F deg and tends to produce uniform temperatures throughout the room. It also makes baseboard radiators especially adaptable to base mentless homes, where cold floors, are prevalent.* Heat loss calculations for baseboard heating systems are the same as those used for other types of radiation. The procedure for designing baseboard heating systems is given in I-B-R Installation Guide No. 5.1 Ratings for baseboard radiation are expressed in Btu per linear foot: The ratings for cast-iron baseboard units have been standardized1 and are given in Table 5. Ratings of finned-tube units are listed in manufacturers' catalogs: . * Pipe coils are assemblies of standard pipe or tubing (1 in. to 2 in.) which are used as radiators.. In older practice these coils were commonly used in factory buildings, but are not often found in this service today. When coils are used, the miter type assembly is preferable, as it readily permits expansion in the pipe. The heat emission of pipe coils placed vertically on a wall, with the pipes horizontal, is given in Table 6, which has been developed from available data and does not represent definite results of tests. For such coils the heat emission varies as the height of the coil. The heat emission of each Table 6. Heat Emission of Pipe Coils Placed Vertically on. a Wall (Pipes Horizontal) Containing Steam at 215 F and Surrounded with Air at 70 F Btu -per linear foot of coil per hour (not linear feet, of pipe)- Sox or Pipe Single row________ ___ ___________ Twa_ .. __ ___ __ Four__ . -------- ------- Sit RtphL. ______ _ _____ __________ ____ Twelve_____________________ __ ___ 1 In. 132 252 440 567 651 732 . . 812 IKI. 162 312 545 702 796 907 1005 1141s. - 185 348 616 793 907 1020 1135 1 1 i I Radiators and Convectors 507 pipe of ceiling coils, placed horizontally, is about 126 Btu, 156 Btu, and 175 Btu per linear foot of pipe, respectively, for l-in., lj-in., and l j-in. coils. CONVECTORS Convectors are space heating devices composed of a casing with outlet grille, and an extended surface heating element of fin-tube or cast-iron fin surface. The casing usually contains a damper. The air enters the en closure near the floor line below the heating element, is heated in passing through the element and delivered to the room through the outlet grille located near the top of the enclosure. The room air movement thus established accomplishes a reduction in floor to ceiling temperature dif ferential and tends to assure comfort in the living zone. A typical re cessed convector is shown in Fig. 1. Factory-assembled units comprised of a heating element, casing and outlet grille with damper are widely used. Grilles may be used over the air inlets. In cases where enclosure's are to be used but are not furnished by the heater manufacturer, it is important that the proportions of the cabinet and the grilles be so designed that they will not impair the performance of the assembled convector. It is desirable, that the enclosure1 or housing for the convector fit as snugly as possible so that the. air to be heated cannot by-pass, the heating element in passing through the enclosure. Gast-iron heating units may be concealed in a cabinet or enclosure for appearance. In such cases a greater percentage of heat is conveyed to the room by convection thereby resulting in a form of gravity convector. The output of a convector, for any given length and depth, is a function of the height of the discharge grille above the heating element. Therefore, the published ratings are generally given, in terms of square feet of Equiv alent Direct Radiation, EDR. For steam convectors, as for radiators, 240 Btu per hr may be taken as an equivalent square foot of radiation. When more than one heating unit is used, one mounted above the other in -the same cabinet, the output of the upper unit, or units will be materially less than that of the bottom unit..