Document X7eNE6VvLXRNOy3NBj3OODGLR

Wtaj % im U> INDUSTRIAL HYGIENE ** ALCOA, ROCKDALE ARD 002850 CONTENTS S' 1. Evaluation Of Catco System^--------------------------------------------------------------------------------------------2. Industrial Hygiene Safeguards----------------------------------------------------------------------------------------- 14-15 3. Area Surveys For Mercury Vapor---------------------------------------------------------------------------------------- 16 4. Hazardous Materials Handling Conmittee Policy On Container Disposal------------------------- 17 5. Indus tial Hygiene Rule 1-000-------------------------------------------------------------------------------------------------------- 18-19 6. Polychlorinated Biphenyls-------------------------------------------------------------------------------------------------------------- 20-^3 ARD 002851 A. G. CLAYTON J. DAMIANO -w E. B. PARKER 1983 January 12 MEMORANDUM 1 RE: EVALUATION OF CATCO SYSTEM - ROCKDALE WORKS Abstract Air samples were collected on 1982 August 31 and September 01 to determine the effectiveness of the Catco System for reducing crane operator exposure to fluorides. The test results indicate that the Catco System offers substantial reductions in breathing zone air contaminant concentrations. Lower protection efficiencies were observed in some samples that can be explained by the horizontal movement of the crane, breaking the air curtain, and hood aprons that were not entirely in place. Temperature measurements were also made. The substantially cooler tempera tures under the air hood suggest a general improvement in working conditions for the crane operators. This is borne out by the many positive comments by the employees. In addition, potroom supervisors have described significant improvements in productivity following installation of the Catco System. Description The Catco System provides positive local ventilation to crane operators without the problems associated with an enclosed crane cab. The system was manufactured by the Crane Air Trac Company of Burlington, Ontario. Figure 1, although not exactly the Rockdale installation, shows how the con cept works. At Rockdale Works, equipment rooms located in the courtyards between the potrooms draw in outside air and deliver cooled, conditioned air to a rectangular duct running the length of each potroom. The bottom of this duct is slotted and equipped with a special.seal which allows each crane to tap into the duct. Air is delivered through a tube to a circular diffuser mounted above the crane operator's seat. An air curtain is formed at the perimeter of the diffuser and conditioned air is introduced inside this curtain to flush out potroom gases. About 500 cfm of conditioned air is delivered to the crane cab at temperatures which vary depending upon ambient conditions. Some degree of comfort control is provided by means of a thermostatically controlled electric heater in the diffuser. Photograph 1 depicts a typical crane cab installation. ARD 002852 Page 2 The Catco System was selected as the most cost effective solution to reducing crane operator exposure to gaseous and particulate fluoride. Enclosed air conditioned crane cabs were considered but not selected due to problems in maintaining visibility for the operator and difficulties in maintaining each air conditioning unit. The Catco System provides nearly unimpeded mobility for the operator with no obstruction of vision. Fewer maintenance difficulties are anticipated in comparison to individually air conditioned crane cabs. Methods Air samples were collected simultaneously under the air hood, close to the operator's breathing zone (Photograph 2), and outside the hood. The "cab" sample was positioned far enough from the hood to avoid the effect of fresh air, but close enough to give a reasonable approximation of the air contaminant concentrations in the area of the crane. The "cab" air sampling instruments were positioned near the ladder (Photograph 3) or on the superstructure of the Catco hood (Photograph 4). Each potroom has two cranes. The sampling instrumentation was mounted on the crane (east or west) intended to be used more often by the crane operator. The air sampling was performed by Jim Richter, Leon Young, and Joe Damiano. The samples were analyzed in the Rockdale Works Laboratory for total particulate, particulate fluoride and gaseous fluoride. Results and Observations ---------------------------------------The test results are shown in Tables 1 and 2. Each table lists the air contaminant concentrations in the "Hood Interior" and for the "cab" (outside the hood). A "percent efficiency" was calculated for each crane in the study. Example: Room 26 West Crane sample (1982 August 31) Cab: Hood Interior: DIFFERENCE Gaseous Fluoride (mg/m3) 2.619 0.520 2.099 2.619 X 100 - 80.11 efficiency The permissible exposure limit for fluorides (gaseous and particulate) is 2.5 mg/m3, as an eight hour average. This particular hood offered a major reduction in gaseous fluoride concentrations from 2.6 mg/m3 to 0.5 mg/m3, an 80.1Z efficiency. Tables 1 and 2 suggest that the Catco System offers effective protection for gaseous and particulate fluoride exposure. The distribution of "percent efficiencies" is shown in Table 3. The variation is probably due to the movement of the crane. The fresh air curtain is broken when the crane is moved. Additionally, on 1982 September 01, the air hood canvas apron was rolled up on the Room 6 East Crane and the Room 22 West Crane, probably resulting in the lower efficiencies revealed through our air sampling. > ARD 002853 Page 3 Prior to the survey, we observed a few crane operators leaning forward and ' - outside of the air curtain perimeter. This problem can be solved by moving the hood forward on its tracks. It is important for each operator to adjust the hood to his or her size and posture. Temperature Measurements Temperature measurements were taken in conjunction with the air samples. Wet bulb measurements were made under the Catco hood and on the crane outside the hood with a Reuter Stokers Model R55-211D "WIBGET" heat stress monitor (Table 4). Earlier measurements made by Jim Richter (1981 September 08) are included (Table 5). The wet bulb temperature measurements reflect reductions in convective heat and humidity; however, the data should not be interpreted as measures of heat stress. Even without the air hoods there is not a "heat stress" hazard for the crane operators because their work involves minimal physical effort. Accordingly, the temperature measurements should be considered in terms of comfort. The cool air certainly represents a general improvement in working conditions for the crane operators. This is borne out by the many positive comments from employees. In addition, potroom supervisors have described significant improvements in productivity following installation of the Catco System. Please contact us with any questions that you may have.. A. G. CLAYTON J. DAMIANO AGC:JD:EBP:cch Attachments Copies: Mr. J. Richter - Rockdale Works Mr. L. Young - Rockdale Works Mr. G. H. Lantz - Rockdale Works Mr. J. L. Roddy - Rockdale Works Mr. J. W. Havins - Rockdale Works Mr. W. J. Drake - Rockdale Works Dr. W. T. Washam - Rockdale Works Dr. L. F. Schaller - Point Comfort Operations Mr. L.. F. Wagner - Point Comfort Operations MTV Mr. E. Rumberger - Pittsburgh 06 E. B. PARKER ARD 002854 s e rie s **1 5a0 0i r S ta in le s s tra e ste 5 Photograph 1 ARD 002856 6 ARD 002857 AFID 28S8 8 Photograph 4 ARD 002859 CATCO SYSTEM EVALUATION ANALYSIS 9 N? 3- ARD 002860 10 ce o CM O Oo CocMno cUcJ. oc s >- CATCO SYSTEM EVALUATION ANALYSIS oo uO o CM CM ABD 002861 m TABLE 3 DISTRIBUTION OF PERCENT EFFICIENCIES CATCO SYSTEM EVALUATION SURVEY DATES: 1982 August 31 and September 01 Efficiency Range 91-100 81- 90 71- 80 61- 70 51- 60 41- 50 31- 40 21- 30 11- 20 0- 10 40 Total Particulate 3 4 3 2 0 3 1 2 0 0 0 Particulate Fluoride 0 5 7 1 0 1 1 1 1 0 1 11 Gaseous Fluoride 6 4 3 1 0 1 0 1 0 1 1 JDamiano:gac 1982 November 05 ARD 002862 ALUMINUM COMPANY OF AMERICA Rockdale Works LABORATORY IIJH Table 4 12 REPORT TO Joe Damiano, Point Comfort DATE 32-09-02 REPORT NO. nn-H _ SAMPLE OF Temperature RECEIVED FROM COPIES TO description E. B. Parker Wet bulb temperature readings taken in potroom crane cabs. Crane Room No. T IME Date Location Temperature Temperature outside OF CRANE UNDER CATCO HOOO CATCO hood influence West 12 East 20 1300 82-08-31 1050 82-08-31 Pot #40 55 V 1 24 45- 76.5* F 77.4 83.5 77.5 77.0 77.0 78.1 83.2 * F 5-3 86.1 35- 86.? 86.3 87.0 East 24 1120 82-08-31 3 72.6 20 69.5 4l 70.5 86.0 86.2 West 128 1330 82-08-31 42 66.0 33 63 66.0 70.2 79- 72.1 88.0 86.5 877-.43 west 24 1320 82-09-01 10 73-4 31 66.9 East 130 1210 82-09-01 4 73-1 23 67.0 4o 63.2 87.6 87.4 83.0 88.7 90.1 West 134 1250 82-09-01 52 66.0 61 69.3 7$ 70.2 87.1 37.3 36.6 5F-IS (MV. S-j) ANALYZED BY APPROVED BY ARD 002863 1382 SEP 0 3 A. . C. fII "r'*- r~ f t v - ruM'HL<wa^!|U _____ IfocUff VO#k S" REPORT TO SAMPLE OP S. J. Spell Air Temperature QF AMERICA" LABORATORY DATE 9i-09-o3 REPORT NO. 1 (o L RECEIVED FROM copies to description E. B. Parker Readings taken on 8l-09-01 from the maintenance bridge OF THE EAST CRANE IN ROOM 22 AT THE BELOW LISTED LOCATIONS. Time 1355 lino 1425 1445 1500 Location Ambient Temp Relative Humidity East Passageway 92* F 56* Pot #1 Pot #12 Pot #24 Pot #36 94 93 95 95 5* 53 55 55 Room ;22 Temperatures Dry Wet Globe Bulb Bulb Bulb 1l8V 117 I33 131 131 86 V 87 89 39 89 119V 120 135 134 134 Dry Bulb Crane Cab w/CATCO 96 V 98 104 102 99 r l u PIMl (M. Ml) APPROVED RY ARD 002864 13M SEP 1 A A. G. U. Industrial Hygiene Technical Bulletin no. 83-i #. Thomas Washan, M.D. Rockdale Works Date: 1983 February 09 RE: VANADIUM EXPOSURES - No. 6 (BUNKER C) FUEL OIL Ref. Industrial Hygiene Safeguards___________________________________________ Periodically, boilers must be shut down to remove the scale that accumulates on the tubes. This removal can be a very dusty operation. Boilers fired with No. 6 (Bunker C) fuel oil can present a significant employee exposure to vanadium pentoxide for those engaged in the cleaning process. Even though vanadium levels in fuel oil can vary, employee exposures to vanadium compounds can be quite excessive regardless of the levels of vanadium present in the feed stock oil. Some personal samples reflecting employee exposure levels during boiler clean-out have ranged as high as 13.5 mg/M^ for vanadium pentoxide. Vanadium levels in the parent fuel oil were only 70 ppm where these airborne exposures occurred. Certain vanadium compounds (e.g. V2O5) are quite toxic by inhalation. Severe upper respiratory tract irritation, bronchitis, emphysema, pulmonary edema, etc. may be observed. For these reasons, we recomnend the following Alcoa exposure limit for vanadium compounds: 0.05 mg/M^ - respirable dust and fume (as V2O5) - time weighted average. As a reminder, OSHA has established a celling limit of 0.50 mg/M^ (as V2O5) for total vanadium dust and a ceiling limit of 0.10 mg/M^ (as V2O5) for total vanadium fume. The Mine Safety and Health Administration (MSHA) limits dictate a celling limit of 0.05 mg/M^ (as V2O5) for total vanadium fume. In light of the above, we recommend that you practice the following safeguards when No. 6 fuel oil boiler clean-out takes place. 1. Work practice controls (l.e. dust suppression techniques, exhaust ventilation, etc.) to minimize employee exposure to boiler dust is recommended where feasible and necessary. The following controls which were developed by Pittsburgh's Power Engineering Division are advised: A. The cleaning of boiler tube surfaces prior to any employee exposure is recommended. Procedures to accomplish this include the following: (1) Prior to removing the boiler from service, all sootblowers should be operated through a complete cycle to clean tube surfaces as best as possible. ARD 002865 Industrial Hygiene Technical Bulletin 1983 February 09 Page 2 (2) Water washing with sootblowers as the boiler is being brought out of service can be tried. Plant condensate would be acceptable to use. The water pressure should be in the 200-400 psi range. Where appropriate, tube metal temperatures should be sufficiently reduced before water washing, typically no greater than 265F. This has proven to be an ideal tube metal temperature limit for this water wash procedure to be effective. (3) In the event that tube surfaces still contain large amounts of dusty, friable ash after the boiler is taken out of service, a manual water wash may be done with the following conditions. (a) A high pH water is used; i.e., pH in the range of 10-11. Plant condensate should be able to meet this requirement. (b) As soon as possible after work is completed, water should be drained and the unit thoroughly dried out. B. Local exhaust ventilation employing portable Venturi-jet type exhausters placed at upper level manholes should also be considered where necessary to reduce excessive dust levels. However, the exhaust from these portable blowers will need to be "piped" away from any occupied areas to avoid exposing other personnel. 2. NIOSH-approved respiratory protection for toxic dusts should be worn when the potential for exceeding the above exposure limits for vanadium exists. Due to the irritative properties of boiler dust, we recommend full face respiratory protection. Moreover, past industrial hygiene exposure measurements for vanadium when boiler clean-out has occurred have indicated that air purifying respiratory protection may not provide an adequate margin of safety. Respirators with a higher protection factor (i.e. supplied-air respirators) appear justified in most instances. These factors, coupled with your particular exposure potential, should be kept in mind when deciding what type of respiratory protection to select for your given situation. 14 ARD 002866 Industrial Hygiene Technical Bulletin 1983 February 09 Page 3 3. Where appropriate, adequate personal protective equipment (i.e. disposable coveralls, eye protection) to minimize skin and eye contact with boiler soot as well as the water used for dust suppression is recommended due to their corrosive properties. 4. It is suggested that employee sampling for vanadium exposures be conducted the next time boiler clean-out takes place. If you have any questions concerning the above, please advise. 15 Distribution: I.H. Distribution List cc: G. J. Celedonia, Pittsburgh WP5 W. L. H&rtner, Pittsburgh WP5 D. E. Jones, Pittsburgh WP5 J. H. Kedrowski, Pittsburgh 19AB J. R. Lynch, Pittsburgh WP5 J. R. Mitchell, Pittsburgh 19AB J. G. Nelson, Pittsburgh WP5 Q ARD 002867 r V E r' ALUMINUM COMPANY OF AMERICA Rockoalt Works LABORATORY REPORT to E. 3. Parker DATE 87-02-10 SAMPLE OF A1R 16 PWlTdO. I 1w i "H RECEIVED FROM copies to Dr. W. T Washam. W. T. Eckert, C. P. Kouba, A. Glaser description Area surveys for mercury vapor. On I9S3 February 07 a qualitative analysis for mercury vapor was perfjsmeo using a Jerome Instrument Corporation Gold Film Mercury Vapor Analyze', Mooel 4oi, in the following areas: 1 Rectifier STAT1 ON, LOWER LEVEL, LUNCHROOM 2 Rectifier STATION, LOWER LEVEL, IMMEDIATE WORK AREA OUTSIDE LUNC.-'DOM 3 Rectifier station, UPPER LEVEL, METER SHOP Areas tested were drains, behind and under cabinets, refrigerators, stoves, WORK TABLES, AND ALONG BASEBOAROS. No MERCURY VAPORS WERE OETECTED IN ANY OF THE AREAS TESTED. NOTE: 1. Instruments borrowed from Alcoa Technical Center. 2. A positive response was obtained when the instrument was exposeo to AN OPEN BOTTLE OF MERCURY. ! IMMI (ftCV. Ml) ANALYZED BY APPROVED BY 1983 FEB 1 4 A. 0. C. ARD 002868 Rockdale's container disposal policy is summarized below. Empty Containers Approved For Release To Employees Type Container Material Contained Fiber Drum Fiber Drum Plastic Pail Plastic Pail Fiber Drum Tabular Alumina Activated Alumina Soap Refractory Cement (Penseal 25) Graphite Supervisors are responsible for insuring that containers to be taken are clean. Their signature on the gate pass attests to the fact that they have inspected and released the containers. It is important that this inspection be thorough in order to avoid incidents which could result in liability claims. No metal containers are on the approved list. Persons, desiring to add specific containers to: the approved list should contact the Hazardous Materials Control Committee. Empty Metal Container Disposal Returnable empty metal containers are accumulated in a designated area in the south yard and sold to a D.O.T.-approved reclaimer. Non-returnable metal containers are accumulated in a separate area in the south yard for ultimate disposal in the Class II landfill. Disposal is accomplished by taking accumulated containers to the landfill at a time when the area is being worked on by IGC's bulldozer. This will facilitate immediate crushing and covering of the containers. Accumulated metal containers are not to be released for any use inside or outside the plant fence because of potential chemical exposure hazards and because severe explosions and/or subsequent fires may result if welding, cutting, or other hot work is done on containers that my not be entirely free of combustible solids, liquids, vapors, dusts and gases. ARD 002869 FROM E. BROOKS PARKER ROCKDALE WORKS -6-; C cL J'J/: HOLDERS OF ROCKDALE WORKS SAFETY MANUAL 18 1983 July 15 RE: INDUSTRIAL HYGIENE RULE I-000 Attached is a revised Frequency of Training table for the referenced rule. The table has been changed to indicate a respiratory protection training requirement for the Atomizer. Please insert the new table in your manual and destroy the old one. ;r EBP/mz Attachment cc: J. E. Richter Q ALCOA ARD 002870 (rcv ua) R adi a t 1on 1 i i 1 i S. 1 1 >1 1 t i- >1 Frequency o f T ra in in g r-- S- o 1 i i >1 i 1 1 1 r-- "-s. 00 CSJ u 1 >1 CM 1 a> r-- So t i i i- s- 1 1 1 r-- >! > JZ CM CM </) CO <-> 1 i t | 1 1 1 1 CL 1 &> CM 1 SI1 oj -a r- o ( i L. 1 1 1 S- i- S- s- 1 3 >i > > >! *" LL r-- r-- >> S- C oo +-> !- 1T3 4-> S- O r- OJ Q.-M c/1 O <U SOC CL s- s. >s > i1 r-- J- S. s- >> 1 u > >* 1 1 O r- 4-> *C ai > c s<- <i> i- oo fl3 C <D O Xo S- s- U L- U i- s- S> > >. > >, r-- r~ - L. >i 1 ai 00 r* i- or E N a> r-- r- E > O S- N O O O O -M <d O 4-> r- O +-> 4-> 0) r* r-- U i- OS-**-- +> o -O -o s- O a. E r-- r- 4-> S- 4-> r-- <-- i- io -o D Ol to o o 4-> > -M T- t-- "O fd *-- o O -- s. +-> O c o o o +* *d a> o a. os CL --* a. Q_ < CL LU O Q. t_) =3 s z ARD 002871 mothoda. p ro o a e i. product* or proceduro* deicnbed or N itU lioM . tx p N or ImpCed are made at to the utility oe effective, doU Alpoa'l ppneh. "m i h not intended to be i recommendation * * **(* l* <* Alcoa. No wartantic. |u M u i or repre Jtooomntandpd herein. ! "M 0 ALCOA Engineering Standard .. Materials and Standards Section Pittsburgh .POLYCHLORINATED BIPHENYLS (PCBs) Urm r' ia score 's<^/ 35.4.9 Jifl1982-03,1 f&u-r-fca 20 r.- This standard provides a brief history of the usage of PCBs in the United States, the action taken by the U.S. Government to have them eliminated from our environment, and Alcoa's past and future responses to the problems which PCBs have created. 2.0 ORICIN OF PCBs 2.1 The polychlorinated biphenyls constitute a family of organic chemicals. They were or iginally developed, manufactured, and sold in the U.S. by Monsanto Chemical Co. or St. Louis, Mo. starting in 1936. Their use in products continued until the third quarter or 1977. On 1979-03-31 any future manufacture of them in the U.S. became illegal. 2.2 Monsanto sold the PCBs under their trade name Aroclor 1240, 1252, etc. when they were Incorporated in a product made by someone other than Monsanto, their presence in the finished product may not have been identified or acknowledged. 2.3 Within Alcoa's manufacturing facilities, the PCBs are most, apt to be present In the fol lowing materials*..- ..t. 1* lctrlcl capacitors .. 2. Transformer dielectric fluid. ->* 3. Phosphate.ester type-firm resistant hydraulic fluid*--' ~~ 4. Oil filled circuit breakers 5. Hot oil:hast transfer systems . GOVERHHgMTAfc-REGULATION Of THE'PCBs 111 3.2 i*i 3.4 4.0 The toxic characteristics of PCBs were unrecognized until the late 60*s and early 70*s. Then, research biologists end environmentalists were beginning to identify the potential danger,that these chemicals presented to the environment^ They also discovered the aore heavily^chlorinated PCBs--to be environmentally- perslatant/.and bloaccumulatlve to soae dogre*^m^%o Mu-rsl- Congress: hak,,no/ aandated. that PCBs,. ba located,. controlled^and#ultimately destroyed. Authailtyl.hm*lbaan.'awarded* to- the*'Ehvlronmmntal-Protmetibrir,Agency^to establish the nec- essay ' ' isifor* ellmlnatlw<r.-thsscontraverxlal^chemicals rrom our en- vi rfd^eu.' mxiinem m ----- ? -***------ Alcos'so'objsctivm.rls` to-.wortc with-ths-Environmental Protection Agency lo developing the detallfaiths' regulation' so that .PCBm-; can_bs-pzoaptly|iandlsd.. end carefully removed froa ou% processes. -"vrj*" t8 in rr - v. i i*- w.- .--O The remainder of this standard will highlight activities in the major areas of concern to Alcoa. PROTECTION OP ALCOA PERSONNEL WHILE HANDLING PCBs 4.1 Employees handling PCB-contemlneted fluids should use good personal hygiehe practices to ainimize skin and eye contact since PCBs are readily absorbed through the skin and eyes. Appropriate impervious protective clothing should be used by employees engaged in work assignments where skin and/or eye contact with PCB-contemlneted fluids is pos sible. Employees who have had potential skin exposure to fluids containing PCBs should be advised to wash before eating, drinking, snaking, or using toilet facilities. 4.2 Air exposure tb PCBs is not likely to present a health hazard since these compounds have a very low vapor pressure. However, where alstlng or elevated temperatures exist, air sampling to insure safe airborne exposure levels is advised. 4.3 Women of child-bearing age should not be assigned to tasks, where periodic skin/eye ex posure or a single extensive skln/eye exposure could occur with a reasonable likeli hood. Considerable Judgment Is necessary in determining whether or not potentially harmful exposures to PCBs far women of child-bearing age can occur for a given task. Plant Industrial hygiene and medical personnel in conjunction with the Pittsburgh Indus trial Hygiene and Medical Divisions should be consulted when decisions are rendered as to whether or not women of child-bearing age should be assigned to particular tasks in volving potential PCB exposures. 4.4 The above recommendation concerning women of child-bearing age refers to day-to-day as signments only and should not be used as a means of disqualifying any female from any classification or otherwise adversely affecting any other tern or condition of employ ment such as promotion, shift assignments, and layoff selections. When the employee re fuses such assignments It is a Justification for an overtime by-pass. T liit iiindarJ ii lk proptny c l AJumlaptp Cbmpaay o f Am tdc* ana mutt be ictumed on * q u t. (I ehtU not b* npeOducM O tropkd, in whole or in part, or med on behalf o f oUwn tbaa A huetonC om paay o f America or its tubddiaiiai, without parmW6o< -rW S ' ;t - ' . Tbit en(incerfni atandard la provided aolaly fgr th f nmtoya o f die* ARD 002872 engineering Standard ALCOA Materials and Standard^ Section* Pittsburgh POLYCHLORINATED BIPHENYLS <PC3s) 35.4.9 . PAGE 2 1982-03 t.? Plant Industrial hygiene personnel should always be consulted ror guidance whenever sit uations arise involving potential employee exposures to PCBs. Industrial Hygiene Tech nical Bulletin #79-1, entitled "PCBs in Electrical, Hydraulic and Heat Exchanger Equip ment ,* dated 1979 October 18 should be consulted by plant industrial hygiene personnel in determining appropriate industrial hygiene controls for PCBs. 3.0 GOVERNMENTAL INSPECTION or ALCOA FACILITIES The legislation provides Tor plant inspections by government representatives bearing the proper credentials. Plant Environmental or Industrial Hygiene representatives oust be available for representing the plant interests for this visit. In addition to courteous treatment, two other major requirements must be handled effectively: 1. Complete notes shall be kept by our representative on the scope, recommenda tion, or mandates covered by the discussions. 2. The inspector may request that samples be taken of chemicals from our proces ses. One large sample must be taken and carefully divided into two portions, one for the inspector and another to be used by Alcoa for further tests. Com plete documentation of the time, place, individuals involved, etc., must be re corded for each sample. i 6.0 ELECTRICAL CAPACITORS. TRANSFORMER DIELECTRICS. AND OIL FILLED CIRCUIT BREAKERS - 6.1 Until 1978, the dielectric fluids in capacitors were usually PCBs. The regulations state that capacitors with more than three pounds of dielectric fluid require special disposal procedures unless the label indicates no PC8s in the fluid. Large capacitors without proper labels can be disposed of in routine fashion after laboratory tests cer tify that no PCBs are present in the fluid. 6.2 A small number of electrical transformers used PCBs as the dielectric fluid. A large number of oil filled transformers were contaminated by- PCBs 'accidentally or through .careless handling at the time of manufacture. Some PCB -contaminated oil has been found -in circuit breakers. ...- ..v .-du- . .3: *--.* - --- i 6.3 Wlttf thl`variety of equipment., applications.-andrfluidsi a* precise'method of testing' for PCBs "was"initiated, by thauAnalytical* .ChemIstryiOivision etvATC-t*Equipaent has been^-pro cured,* analytical methods developed,L and sampling procedural sbqgastetf* In a memorandum that was sent to domestic and foreign locations (see reference 9). 'Within Axcca, riuids in transformer*', and oil . Uiled circuit* breakers^.were ^ested^Tor PCB content -endt re corded. Any unit in doubt.should be- tested and- added to these2 ^records.- A large`amount of correspondence on `these' subjects has been shared between th4 plant :staffs, Messrs^C. L. Pittman and H. E. Church of the Pittsburgh Engineering and Power Oivisions-'respeu- tlvely. (Hr. T. B. Oliver Is now handling Mr. Pittman's correspondence on this subject.) 7.0 7.1 : 7.2 7.3 HYDRAULIC SYSTEMS Monsanto is the only company that has used PCBs to formulate a phosphate ester hydraulic fluid called Pydraul-F9, A200, 623, etc. They discontinued the use of PCBs in' those products In 1970, but residual amounts nay remain in those systems which previously used those products. All fire resistant hydraulic fluids being marketed today are manufac tured without PCBs. Alcoa has assumed that PCBs may still be present In any hydraulic system that used a phosphate ester (fire resistant) fluid prior to 1978. In 1979, samples from all known phosphate ester hydraulic systems, past ur present, were tested at ATC or by an EPA approved laboratory for PCB content. A system with concen tration above 30 ppm was cleaned and refilled with PCB-free fluid. Records of these tests are available at each plant identifying the system, the concentration levels, and which contaminated fluids have been segregated pending ultimate treatment, recovery, or disposal. Two PCB regulations were issued in 1979 (see references 2 and 3) and were not clear in routine checking requirements for the number of hydraulic systems in an industrial com plex. In working with the EPA Alcoa submitted written comments (reference #4) on 1979-12-27 and oral comments at a public hearing in Washington, 0. C. on 1980-01-20. Pending a further ruling by EPA, Alcoa is testing for PCBs on systems as described in 7.2 above. Additional testing should be done on systems which we suspect may have been accidentally contaminated during routine operation or maintenance functions. ARD 002873 ALCOA Engineering Standard Materials and Standards Section Pittsburgh POLYCHLORINATED 31PHENYLS (PCBs) 35.4.9 PAGE 3 1902-03 d o iin i Alcoa*! approach, and i i not intended to be a recommendation for any recipient other than Alcoa. N'o warranties, guaranties or reprelenlatlon!, expret! or implied are made at to the u tility or effectiveness o f the methods, processei, producti or procedures desenbed or recommended herein. 7, k The potential for PCS contamination of process lubricant formulations exists where hy draulic systems containing PCBs may have leaked into such lubricant formulations (i.e. hot mills, continuous rod mills, etc.). Even though these hydraulic systems may cur rently contain less than 50 ppm, past leakage may have already created a concern. Where a hydraulic leakage problem into a process lubricant formulation could have developed, the process lubricants must be checked for PC8 concentrations to insure safe levels. 8.0 RECLAIMING PHOSPHATE ester hydraulic fluids 8.1 Where phosphate ester hydraulic fluids are removed from a system for filtration or reuse the PCB content must be determined. Fluids containing less than 50 ppm of PCS may le gally remain in use. It is imperative that the PCB problem not be extended by adding a reclaimed contaminated fluid containing less than 50 ppm into a system that has no de tectable level of PCBs. 8.2 Any quantities of PCB hydraulic fluids being held in restrictive storage should not be disposed of prematurely. EPA has published a disposal deadline of 1984 January 1 for all fluids taken out of service by 1983 January.1. While these rules are being liti gated, ATC is trying to develop our own process for removing PCBs from these fluids. Final decisions on disposition will be based on our internal capabilities in combination with the EPA timetables. 9.0 HOT OIL HEAT TRANSFER SYSTEMS 9.1 High temperature heat transfer or heating systems are not commonly used in Alcoa's plants. IT one does exist, It must be tested for the presence of PCBs. 9.2 When a petroleum oil was used as the heat transfer media no PCBs should have been pres ent. Exxon's Caloria and Mobil's Mobilthurm, both identified as Alcoa ML 844, were com monly used for this application. Neither of these brands of fluid contained PCBs as part of their formulation but they should be checked to verify that fact. T in, tlm dard it the property o f Aluminum Company o f America and m utt be relumed on re>|ueil. It aha)] not be reproduced o r copied . in whole or in part, or used on behalf o f oilier! than Aluminum Com pany o f America or its subsidiaries without permltiion. This engineering standard Is provided solely for the purpose o f dil- 9.3 Any system that used Monsanto Chemical's Therafnol #1, #2, or #3 consisted of 100* PCS and should be handled accordingly. Monsanto's Aroclor 1242 or 1428 were likewise pure PCB fluids:- 9.4 Any system that used Oow Coming's Oowtherm C, Alcoa ML 646, may contain monochlorinsted biphenyls. In addition to chemical verification of this HCB content, end handling as a PCB fluid, the Oow Chemical Co. should be consulted for further information on these systems. 9.5 Any system using Monsanto's Therminol 55 or Tharminol 66 should be PCB free' (see Alcoa ML 847 and ml 848, unless one of the fluids mentioned in 7.1 and 9.3) had been used previously. r 10.0 TESTING FUR PRESENCE OF PCBs 10.1 Testing for PCB content in any fluids should be conducted at the Analytical''Chereistfy Division, ATC. They have developed standard analytical methods (see reference 8) for use with suspect transformer oils, hydraulic fluids, and other oil matrices. Their testing program has been extended to waters, soils, sediments, and sludges as an out growth of their acceptance by Alcoa plants. Sampling procedures have been prepared (see reference 9) and contact should be made with J. P. Auses at ATC if further assistance is required. Some commercial laboratories, licensed by the EPA, are capable of conducting these tests as an alternate source. REFERENCES 1 Technical Bulletin 079-1 titled "PCBs in Electrical Hydraulic and Heat Exchanger Equip ment" dated 79-10-16. Available from Alcoa plant(s) Industrial Hygiene coordinator or Pittsburgh Industrial Hygiene Dept. , 2 PCB Manufacturing Processing, Distribution in Commerce; and Use Prohibitions. Federal Register 44/106, 79-05-31, P. 31514 - 31568. 3 PCb Manufacturing Processing; Distribution in Commerce; and Use Prohibitions. Testing of Hydraulic Systems. f Federal Reg. 44/231, 79-11-29, P. 68489 - 68491 B 4 Alcoa letter to Documents Control Officer, TS 793, 0PTS-62005, (PCB/Rft-5) EPA. Letter written by J. S. Boyt Alcoa Pgh. Office 79-12-27. 5 Locating, Handling and Disposing of PCBs. Letter by L. L. Corbin, Pgh. to all plant engineering managers, dated 79-10-26. ARD 002874 ^ ALCOA -iiyiiic'-uny OcdllQcirQ Materials and Standards Section Pittsburgh POLYCHLORINATED BIPHENYLS (PCBs) 35.4.9 PAGE A 1922-03 REFERENCES (Cont.) 6 EPA Regulations Pertaining to PCBs in Transformers, Capacitors, Hydraulic and Heat Transfer Systems and in Waste Oil - tetter from J. T. Bunting/C. L. Pittman, Pgh. to all plant engineering managers, date 79-08-23. 7 PCS Contamination of Phosphate Ester Hydraulic Pluids, letter by J. T. Bunting Pgh. to all plant engineering managers, 79-08-20. 8 Cas Chromatographic Analysis - Determination of PCBs in Insulating Fluids, Standard An alytical Method 03042, J. P. Auses Analytical Chem. Oiv. - ATC. 9 PCB Analysis - Analytical Chemistry Division ATC. J. P. Auses to Memorandum 1981/03/04. 10.2 For further and up-to-date Information on PCBs, please contact your Er.vi^p.-.mental 0*partment or your Industrial Hygiene contact. In Pittsburgh, contact any of the fol lowing persons: M. E. Kommer - Environmental Control Department T. 8. Oliver - Electrical Engineering Division H. . Church - Power Engineering Division R. M. James - Industrial Hygiene C. R. Crook - Mechanical Engineering Division ARD 002875 Industrial Hygiene Technical Bulletin No. 84-4 rV. Tho-ns s'u-, !,!,3, Rockdale '.'/arks Date: 1984 June 18 RE: NUISANCE DUST LIMITS In the past, it has been our policy to use the Occupational Safety & Health Administration (OSHA) nuisance dust limits of 15 and 5 mg/M3 for total and respirable dust, respectively. We have recently reviewed our position as relates to these limits and have decided that we will now adopt the American Conference of Governmental Industrial Hygienists (ACGIH) limits of 10 and 5 mg/M3, respectively, for total and respirable fractions. The reasons for adopting these more stringent limits include the following: -r A. Increasing emphasis on respiratory disease and its possible connection with the excessive inhalation of nuisance particulates. In conjunction with the above, recent findings within one of our operations suggest that excessive dust levels are associated with decrements in one pulmonary function parameter; and B. The desire to achieve uniformity throughout Alcoa operations and with our customers as relates to exposure limits for nuisance dust. Mine Safety and Health Administration (MSHA) limits are 10 and 5 mg/M3, respectively, for total and respirable dusts. Several of our facilities are covered by MSHA regulations. Moreover, the ACGIH dust limits of 10 and 5 mg/M* are widely used by various segments of industry and in many countries throughout the world. These new limits for nuisance dust are effective immediately. Where appropriate, we are in the process of implementing these new limits on all of our commercial MSDS sheets as well as internally used materials. If anyone has any questions concerning the above, please do not hesitate to contact us. ROBERT M. JAMES RMJ-.nld Distribution: I. H. Plant Contacts - Domestic & International Medical Directors - Domestic & International I. H. Division (Pittsburgh & ATC) I. H. Technicians 0 ALCOA ARD 002876