Document X7bLdaop6gZOYoDkvNvqQODwK

wimoN" S4ffrr pwooucts P.O. Box 622. Reading, PA 19603 (215) 376-6161 DATE: May 10, 1985 TO: All Willson Distributors FROM: Technical Service Department SUBJECT: TECH-85-05 REMOVAL OF THE ASBESTOS APPROVAL FROM THE RIO, Rll AND R13 FILTERS, AND THE 1410 DISPOSABLE RESPIRATOR Willson has contacted NIOSH and requested that the asbestos approval be removed on the RIO, Rll and R13 filters, and the 1410 Disposable Respirator. The protection provided by thtese filters and respirators has in no- way changed. Currently NIOSH will still approve these types of filters and respirators for protection against asbestos; however, Willson has taken the above action because we feel that the R12 high efficiency filter, the only remaining filter approved for asbestos, provides the highest degree of protection available in an air purifying filter. n its April 10, 1984 proposed rule for asbestos, OSHA is con sidering requiring the use of high efficiency filters in applications where air purifying respirators can be used. OSHA notes that at both proposal levels (0.2 fibers/cc and 0.5 fibers/ cc) the NIOSH/MSHA certification criteria appears to require the use of high efficiency filters. The R10, Rll, R13 filters, and the 1410 disposable respirators are not high efficiency filters, when OSHA lowers the PEL, the certification of other than high efficiency filters becomes questionable. Using a conversion factor* the Time Weighted Average (TWA) of 0.5 f/cc equates to*"* 0.015 mg/m3, well below the cut-off of 0.50 mg/m3 for other them high efficiency filters as stated in 30 CFR Part II. A TWA of 0.2 f/cc equates to 0.006 mg/m3. What the above actually means is that the legislation is moving towards requiring the use of high efficiency filters where air borne asbestos is present and air purifying respirators are appropriate. Although this is not law yet, Willson Safety Products agrees with the intent of using only high efficiency filters for asbestos in these situations, and has taken steps to modify its product line appropriately to achieve this philosophy. Chronic Hazard Advisory Panel on Asbestos of the Consumer Product Safety Commission. A Division of WGM Safety Corp. _ 41 - (over) TX TINER RMC0062960 TECH-85-05 . Page 2 The following Willson respirators no longer carry an asbestos approval. These respirators should rio longer be recommended for protection against asbestos. The appropriate respirator that now should be used is also shown. NO LONGER APPROVED FOR ASBESTOS Model Number 1210 1211 122110 122113 122410 122510 1410 1610/1710 1611/1711 162113/172113 162110/172110 162410/172410 162510/172S10 3010 3011 302410 302510 302110 302113 3110/3210 3111/3211 312410/322410 312510/322510 312110/322110 312113/322113 1510 1511 152110 152113 152410 152510 3510 3511 352110 352113 352410 352510 TC Number 21C-140 21C-141 23C-51 23052 23C-71 23C-77 21C-214 210182 210183 230131 230134 230140 230142 210253 210255 230378 230380 230389 23C-391 210254 210 256 230379 230381 230388 230390 210307 210309 230567 230569 230575 230577 210308 210310 230568 230570 230576 230578 NEW RECOMMENDATION Model Number 1212 1212 123112 123112 123412 123512 1212 1612/1712 1612/1712 163112/173112 163112/173112 163412/173412 163512/173512 3012 3012 303412 303512 303112 303112 3112/3212 3112/3212 313412/323412 313512/323512 313112/323112 313112/323112 1512 1512 153112 153112 153412 153512 3512 3512 353112 353112 353412 353512 TC Number * 210142 210142 230294 230294 230291 23C-299 210142 210184 210184 23C-296 230296 230292 230301 210257 210257 23C-385 230387 230383 230383 21C-258 210258 230385 230387 23038 3 23C-383 210313 210313 23C-579 230579 230581 23C-583 210314 210314 23C-580 120580 230582 23C-584 TX TINER RMC0062961