Document X7XaJzgJ0rYXY6ZRDGmqK2Ddx

Industrial Hygiene Digest - 43 January, 1950 control of hazarda are combined In this department, vith .the full cooperation of operating and medical staffs of each division. Dust counting and ordinary chemical analyses are conducted by the department; x-ray diffraction ^ spectrographlc analyses are contracted out to other laboratories, and related animal experimentation 1b turned over to a university medical school. Ibis plan has proved successful. 139 Pension and Profit-Sharing Piarm. A.S. Hansen. Taxes (Dec. 1949); Labor Lav J. 1, 219-225 (Dec. 1949). Pension and profit-sharing plans are considered especially In relation to Income tax and for the Bureau of Internal Revenue. The lav of 1942 covers both types of plan, although they differ greats In purpose and In method of administration.."Basically, pension and profit-sharing plans perform different functions.. Unfortunately, If they are combined In one plan, the result takes on the bad rather than the good features of each." A pension plan Is generally applicable to an older, established company, and a profit-sharing plan to new companies or those vith relatively young employees.* He matters of employee contributions, separate car consolidated plans, permanency, partial terminations. Integration with revised Boclal security, Bureau attitudes Ana rulings, and others, are also considered. Accidents and Prevention (Fire and Explosion Hazards, Etc.) l4o Precautionary Fire and Explosion Safeguards In the Use of Chlorine Dioxide for' Industrial Bleaching. NJ3.F.U. Research'Rept. No. National Board of Fire Underwriters, 85 John St., N.T. N.Y. 23pp. (1949), . Chlorine.dioxide Is nov commercially prepared as a chemical bleach ing agent In tallow and fat rendering plants. It is considered In the same general category vith regard to toxicity and chemical reactivity as chlorine, but Is also explosive under excessive temperatures and concen trations . Sodium chlorite, used in the preparation of the dioxide, Is violently reactive vith organic matter under some conditions. The produc tion of chlorine dioxide from chlorine and sodium chlorite Is arranged to give a concentration of 6f> In the vet process and 4$ In the dry process. It must In all cases be kept below the explosion limit of 10$, and the chlorine concentration must be kept below 5$ In the dry process, or the rate of combination will be too high. A nuinber of precautions are . recommended for location of generators, handling and storage of sodium chlorite, and supervision, management, and instruction. l4l Inflammability of Liquids. J.H. Burgoyne and 0. Williams-Lelr. Fuel 28; 145-150 (July, '1949), ' The conceptions of flash and fire.points as applied to single liquids are examined and a number of values of the former characteristic are cal culated from standard flammability data for the vapors. In general, values