Document X7Or9g5Ky16DRoqG8E5xjOOLy

..'. . ^ k ojffwiivj'~ *\fl a y ; Krci^ortic Heating Equipment trade price book *Hydronics ... the science of heating and cooling with water. PRODUCTS Boilers: Gas--Packaged Units Boilers Only Electronic Control Systems Oil --Packaged Units Boiler--Burner Units Boilers Only Stoker Boilers Hand fired Boilers Radiation: Baseboard Panels --Radiantrim --Heatrim Convectors --Multifin --Arco --Cabinet Extras Radiators--Arco, Sunrad, Peerless Oil Burners and Controls Zone Control Sets Gas Conversion* Burners Repair Parts Discounts Terms General Information PAGE 3-d 7-14 15 16-17 18-29 18-29 34-35 36-38 40 42-43 44-46 41 47 39 30-32 30 33 2 48 2 f HH-3 JUNE 4, 1962 notice: The Trode Prices shown herein do not include freight or cartage. Ame rican-Standard PLUMBING AND HEATING OIVISION AMERICAN RADIATOR 4 STANOARO SANITART CORPORATION 40 WEST 40TH STREET NEW TORK IR, NEW YORK PLAINTIFF'S EXHIBIT 01616 AMERiCAN-tStandard GENERAL INFORMATION HYDRONIC Hlf/TfKO ___________________________ __L-r. '......................................................... ..... . BOILER RATlii Boiler ratings ("net I=B=R ratings of Mbh and sq ft of steam", "net rating sq ft water" and "installed radiation", wnere snowni represent the maximum net ioads that may be connected to tne boilers. Steam sq ft ratings are based on 240 Btu per sq ft and water sq ft ratings on 150 Btu (170* water) per sq ft. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heat ing domestic hot water under the following conditions: It is not necessary to increase the boiler size for domestic hot water supply when not more than two bathrooms are to be served or if the use of domestic hot water does not exceed seventy-five gallons in twenty-four hours. Sufficient radiation must be installed for the requirements of the building. In order to select the proper size boiler calculate the heat loss of the building, then divide this figure by 1,000 to get the heat lcs? "cr.ressed in Mbh. Select a steam or water oouer which >, - J net Mbh rating equal to or greater than this flgi ; u :-, appropriate steam or water column. See cn -ent literature for determining the size of radiators and convectors for hot water systems. For an installation where unusual conditions such as large pipe losses, intermittent heating, unbalanced systems, etc . are encountered, it is suggested to calculate the actual piping loss and estimate the pick-up factor to adjust the load and then select the boiler from the published gross output in Mbh (1.000 Btu per hour). GAS FIRED BOILERS The input and output ratings are approved by the American Gas Association. Ratings shown are for installations at sea level and at eleva tions up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. OIL FIRED BOILERS The firing rates or I=B=R burner capacity--gallons per hourare based on the use of oil having 140.000 Btu per gallon heat value, and with 10% COi in the flue gas. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. When Built-in Tankless Heater is used increase the boiler size 12 Mbh for each bathroom in excess of two. STOKER FIRED BOILERS The firing rates or I=B=R burner capacity pounds per hourare based on the use of coal having 13,000 Btu per pound heat value. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. HAND FIRED BOILERS The ratings (installed radiation sq ft) are based on the use of stove or nut size bituminous coal, anthracite coal or coke with 13.000 Btu per pound heat value. See table below for select ing proper size boiler when using coal with less than 13.000 Btu per pound. When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity. BUILT-IN WATER HEATERS (for Arcoliner, Oakmont, Severn, Exbrook Boilers) All tank type Built-in water heaters are rated on the basis of raising the temperature of the domestic hot water 100*F. in three hours with a minimum boiler water temperature of 180* F. on automatically fired boilers and 212*F. on hand fired boilers. All tankless type Built-in water heaters are rated in gallons per minute on the basts of a minimum boiler water tempera ture of 180-F. on oil fired boilers. The maintaining of 180*F. boiler water temperature with rated Sow through a tank less type Built-in water heater is dependent on the oil firing rate for the boiler. In those areas where excessive lime exists in the water, use of Built-in Tankless Type water heater is not recommended except when provision is made for regularly cleaning the heater. Use of Tank Type heater is recommended in hard water areas. WHEN PIPING LOSS IS NEGLIGIBLE The load connected to steam boilers (all fuels) and coal (hand fired) water boilers may be increased by the percentages shown below when the piping loss of the installation is negli gible. The load connected to automatically fired water boilers may be increased by 12`7> when the piping loss of the installa tion is negligible. load installed radiation a<| ft Sttam (all fuals) Watar coal (hand flrad) ineraaao load hy up to 250 251- 500 501-1000 1001-1500 1501-2000 2001-3000 3001-4000 over 4000 up to 400 401- 800 801-1600 1601-2400 2401-3200 3201-4800 4801-6400 over 6400 30% 28% 24% 21% 18% 15% 13% 12% WHERE COAL HAS LESS THAN 13,000 BTU CONTENT When selecting hand fired boilers for burning coal of lower heating value than 13,000 Btu per pound the following correc tion factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq ft). hasting value of coal correction factor 13.000 ........................................................... 1.00 12.500 ........................................................... 1.04 12.000 ........................................................... 1.08 11.500 ........................................................... 1-13 11.000 1.18 10.500 ........................................................... 1.24 10.000 1-30 9,500 9,000 137 1.44 REPAIR PARTS-TRADE PRICES -- Boilers (all fuels) ...................................................................................................................................Lis* Price, less 25% Gas Conversion Burners .............................................. ........................................ . - Lf*J Price, less 25% For List Prices see "American-Standard Radiator Heating Repair Parts Catalog 1956 Edition. Oil Burners................................................................................................................ ............ .U*t Price, (ess 25% For List Prices see "American-Standard Arcoflame Oil Burner Repair Parts Catalog" 1956 Edition. MH 3 P|i 2 01617 AMERiCAN-<Standard At H V ?. |ONIC HE ATI KG packaged borers GAS f!RED W*T,, PACKAGED "GPR" American-Standard GAS BOILERS rui Nuturui, mixeu/ iViuiiwiu.iwrcu cine IP Gases Designed and equipped with controls for tent-s^us forced circulation Factory assembled and crated. Built-in air-separator m top section. ^ A G.A. approved for combustible floors and closet installations WATER ONLY packaged boiler number GPR-60 GPR-80 WATER ONLY GPR-60 GPR 80 FOR NATURAL, MFD., MIXED GASES ONLY A.G.A. Input Mbh 75 100 A.G.A. output Mbh 60 80 not isBsR Mbh* 45 60 not rating sq. ft. watr 300 400 Trad* Price with standard equipment $225.00 245.00 chimney size diameter inches 5 5 height feet 20 20 FOR PROPANE AND BUTANE GASES ONLY 70 56 42 280 $225.00 5 20 95 76 57 380 245.00 5 20 epproz. shipping weight 205 235 205 235 Standard equipment all boilers: V-600 combination diaphragm gas valve furnished for all gases V-600 fea tures built-in gas pressure regulator (except for LP gas) and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated round jacket; Transformer; ASME relief valve (30 lbs); Theraltimeter (30 lbs); Wiring harness; 1" circulator; CB-580 thermostat; AY-553 limit control Controls regularly furnished are for 115 volt. 60 cycle current. Not*: Packaged boilers are shipped with jacket, all controls (except thermo stat), circulator, mam burners and manifold controls and piping factory in stalled and wired. CB-580 thermostat, manual shut-off valve, relief valve and drafthood shipped inside boiler crate. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. For ordering instructions for gas boilers, see page 15. Optional Equipment: (only those below available) Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Zone Control Valve Sets available for water boilers, for details and prices, see page 30. Self-energizing controls (consist of special gas valve, thermostat, pilot burner, limit control) for all gases listed above, available when specified on order at no additional charge. Not*: in areas where manual opening feature is normally desired, we will furnish "GPR" boilers with Self-energizmg controls as shown above. V-600 gas valves with manual opening for "GPR" not available. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 3 01618 HH 3 packaged boilers GAS FIRED WATS* American-^Standard HYDRO NIC HE (VINO PACKAGED G-2 "FPB" AiWERiCAN-^tandard GAS BOILERS Fui' Nuiuiu', mixeu, manufactured Gases Designed and equipped with controls tor forced circulation. Factory assembled and crated. Flush jacket only. ''Elimtnaire" (cast-in air eliminator in left end sectionl WATER ONLY packaged bailer number G23-FPB G-24FPB G-25-FP6 G-26FPB G-27FPB A.OJL input Mbh 60 90 120 150 180 A.OJi. output Mbh 48 72 96 120 144 nat l=B=R rating Mbh 36 54 72 90 108 nat rating aq. ft. water 240 360 480 600 720 Trade Price with standard equipment $255.00 283.00 319.00 361.00 412.00 chimney size diameter inchea 4 5 6 6 6 height faet 20 20 20 20 20 approx. hipping weight 317 377 457 542 632 Standard equipment all boilers: V-600 combination diaphragm gas valve furnished with Natural. Manufac tured. Mixed gas boilers. V-600 features built-in gas pressure regulator and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; 1V*" circulator. CB-580 thermostat, CB-6S5 immersion limit control. Left hand end section without tankless heater opening. Controls regularly furnished are for 115 volt, 60 cycle current. Note: Packaged boilers are shipped with jacket, all controls (except thermo stat) , circulator, main burners and manifold controls and piping factory in stalled and wired. CB-580 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea leveL For ordering instructions for gas boilers, see page 15. Optional Equipment: (only those below available) Runner Type Pilot Ignition for use with listed gases furnished at no charge when specified on order to meet local utility codes. Floor Shield for Combustible Flooring. Add suffix letter "C" to boiler num ber and add 83.00 to Trade Price of boiler. Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual Opening Feature on V-600 gas valve furnished at no additional charge when specified on order to meet local utility codes. Zone Control Valve Sets available for water boilers, for details and prices, see page 30. For complete information on boiler retings, see page 2. For discount on repaid** tee page 2. HH-3 Page 4 01619 AMERiCAN-<Standard HYDRONIC H E A ? -** PACKAGED BOILERS ^AS FIRED WATT* PACKAGED G-2 AMEniCAN-<$tandard GAS BOILERS Designed and equipped with controls lor forced circulation. Factory asssmbled and crated. Flush or Deluxe jacket. Sections tested for 30 lbs. water working pressure. "Eliminaire1' (cast-in air eliminator in left end section). WATER ONLY packagad bolter numbtr A.GUA. input MWi oAu.OtpAu.t Mbti tanUatft A haatar IsWsrH numbar ratine Mfd,, Note Mlxad and LP Oat; LP*Alr Gas 525*1400 Btu nat l=B=ft ratine Mbh nat ratine aqft water Trada Prica with atandard aquipmant fluah Jacfcat dafuia Jackal chlmnay tlza dlamatar Haight inchat fa at approx. hipping waigtit Packaged boiler* without tankless heater G-23P G-24-*P G-25-*P G-26-*P G-27-*P 60 90 120 150 180 48 72 96 120 144 36 240 $271.00 $285.00 4 20 315 54 360 328.00 342.00 5 20 375 72 480 372.00 386.00 6 20 455 90 600 413.00 427.00 6 20 540 108 720 449.00 463.00 6 20 630 Packaged boilers with factory installed tankless heater G-24-*PT 90 72 218 2Vz 54 360 $361.00 $375.00 5 20 390 G-25-*PT 120 96 222 3 72 480 407.00 421.00 6 20 470 G-26-*PT 150 120 222 3l/< 90 600 448.00 462.00 6 20 550 G-27-*PT 180 144 222 3'A 108 720 484.00 498.00 6 20 642 AGallons of water par minute heated from 40F to 140F with 200F boiler water temperature. "Subetitute letter *'p' for flush or *'0" for deluxe jacket. Standard equipment all boilers: (see options, page 9) V-600 combination diaphragm gas valve furnished for Natural, Manufactured, Mixed. LP-Air, and LP gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; 1 Vs" circulator with piping. Controls regularly furnished are for US volt. 60 cycle current. Additional standard equipment for boilers with heater: Tankless heater as listed above. RS-116-F combination immersion control (high and low limits, circulator operation, transformer and built-in relay). CB-520 thermostat. Additional standard equipment for boilers less heater: CB-520 thermostat, combination immersion high limit and reverse acting control. Left hand end section without tankless heater opening. Note: Packaged boilers are shipped with jacket, all controls (except thermostat), cir culator and piping, main burners and manifold controls and piping factory installed and wired. CB-520 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton for flush jacketed boiler and G-23-DP. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. For ordering instructions for gas boilers, see page 15. i For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 5 HH-3 01620 PACKAGED BOILERS GAS FIRED WATII AMEMCANvStandard HYDRONIC HEATING n m ^t/ a rwaMvitu MLL -PURPOSE G-2 AMtRiCASi Standard GAS BOiLERS Designed for forced or gravity circulation. Factory assembled and crated. Deluxe Jacket. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section) WATER ONLY packaged toiler number G-23DPG G-24DPG G-25DPG G-26DPG G-27DPG A.G.A. Input Mbh A.G.A. output Mbh Mfd., Nat., Mixed and LP Gat; LP-Air Gat 525-MOO Btu net IsBsR rating Mbh 60 48 36 90 72 54 120 96 72 150 120 90 180 144 108 net rating 4 ft water 240 360 480 600 720 Trade Price with standard equipment chimney size diameter inches height feet $208.50 4 20 265.50 5 20 309.50 6 20 350.50 6 20 386.50 6 20 approx. shipping weight 317 377 457 542 632 Standard equipment: (see options, page 9) V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.UJL); boiler drain; draft hood; insulated jacket; transformer. G-23-DPG furnished without heater opening in left end section. Water only: Theraltimeter; ASME relief valve; CB-6S5 immersion limit control. Controls regularly furnished are for 115 volt, 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet, above sea level. For ordering instructions for gas boilers, see page 15. a For complete information on ratings, see page 2. For discount on repairs, see page 2. HH-3 Page 6 01621 AMERiCAN-<Slandard HYDRONIC HEATING BOILERS--GAS FIRED STEAA? and WATER G-2 ALL-PURPOSE AMERiCAN-fStandard GAS BOILERS Designed (or water (forced or gravity) or steam. Flush or Deluxe jacket. Factory Assembled Sections. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section) WATER (Available with factory installed Tankless heater, see options, page 9.) boiler number A.(LA. Input Mb* A.GJta output MM- Nat- Milad and LP Gee; LP-Air Ga* 525-1400 Btu B nat l8R rating Mbh nat rating aq ft watar Trada Price with standard aquipmant flush Jacket deluxe jacket G-23--G 60 48 36 G-24-G 90 72 54 G-25-*G 120 96 72 G-26--G 150 120 90 G-27-*G 180 144 108 G-28--G 210 168 126 G-29-G 240 192 144 G-210-G 270 216 162 G 211-G 300 240 180 240 360 480 600 720 840 960 1080 1200 $187.00 244.00 288.00 329.00 365.00 407.00 449.00 480.00 526.00 $201.00 258.00 302.00 343.00 379.00 421.00 463.00 494.00 540.00 chimney size diamatar Inchat height feat 4 20 5 20 6 20 6 20 6 20 7 20 7 20 7 20 7 20 STEAM boiler G-23-*G G-24--G G-25-G G-26-G G-27--G G-28-'G G 29-G G-210-G G-211-G A.GJL input Mbh A.GJt. output Mbh Mfd- Nat- Mixed end LP Gas; LP-AIr Gas 525-1400 Btu 60 48 90 72 120 96 150 120 180 144 210 168 240 192 270 216 300 240 nat IsBsR rating Mbh 36 54 72 90 108 126 144 162 180 sq ft 150 225 300 375 450 525 600 675 750 'Substitute letter "F" for flush or "O'* for deluxe jacket. Trada Priea with standard equipment flush jacket datuxa Jacket $224.00 281.00 325.00 366.00 402.00 444.00 486.00 517.00 563.00 $238.00 295.00 339.00 380.00 416.00 458.00 500.00 531.00 577.00 chimney size diameter inches 4 5 6 6 6 7 7 7 7 height feet 20 20 20 20 20 20 20 20 20 Standard equipment: (see options/ page 9) V-600 combination diaphragm gas valve furnished with G-23 througn G-29 Natural, Mixed, LP-Air. LP gas boilers and G-Z3 through G-27 Manufac tured gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-S32 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); boiler drain; draft hood; insulated jacket; transformer. Water only: Theraltimeter; ASMS relief valve; CB-6S5 immersion limit control. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off; floor pan. Controls regularly furnished are for US volt. 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. For ordering instructions for gas boilers, see page IS. For complete information on ratmgs, see page 2. For discount on repairs, see page 2. Pat* 7 approx. shipping weight 277 353 428 490 553 629 697 761 841 approx. weight 287 363 438 500 563 639 707 771 851 HH 3 01622 BOILERS--OAS FIRED WAT* AMO fTlAM AMERiCAN-cStandard HYDRONIC R EATING' G-2 ALL-PURPOSE AMERiCAJtf-<$tandard GAS BOILERS DIRECT TYPE -- Water boilers for hot water supply Flush or Deluxe Jacket. Hydrostatically tested at 200 lbs. Working pressure 80 lbs. Not recommended (or use in hard water areas. boiler number A.G.A. Input Mbh A.GJL rating--gallons weter per hour output Mbh 60* rise 80* rise 100* rite U(d Nat. Mixed and LP Oat; LP-AIr Cat 525-1400 Btu Trade Price with "OW* equipment flueh Jacket If approx. shipping weight G-23*G 60 48 G-24-*G 90 72 G-25-*G 120 96 G-26-'G G-27*G G-28-*G 150 120 180 144 210 168 G-29-*G 240 192 G-210-*G 270 216 G-211-*G 300 240 96 72 144 108 192 144 240 180 288 216 336 252 384 288 432 324 480 360 58 86 115 144 173 201 230 260 288 $201.00 258.00 302.00 343.00 379.00 421.00 463.00 494.00 540.00 $215.00 272.00 316.00 357.00 393.00 435.00 477.00 508.00 554.00 277 353 428 490 553 629 697 761 841 'Substitute letter "F" for flush or "0" for deluxe jacket. "DW" standard equipment: (see options, page 9) In addition to boiler (or water with "standard equipment" page 7. "DW" boilers are furnished with Ther-pressure-meter instead of Theraltimeter; 80 lb. ASMS relief valve instead of 30 lb. valve; immersion operating control for use in storage tank; tank ther mometer; name and rating plate for 80 lbs. working pressure. For ordering instructions for gas boilers, see page 15. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. FOR USE WITH "IS" EQUIPMENT INDIRECT TYPE --Sfeom boilers for hot water supply Flush or Deluxe jacket. boiler number A.GJL Input Mbh A.GJL. rating--gallons water per hour output Mbh 60* rise 80* rise 100* rise Mfd- Nat, Mixed and LP Gas; LP-AIr Gas 525-1400 Btu Trade Price with MiSH equipment flush Jecket deluxe Jecket approx. shipping weight G-23-*G G-24--G G-25-*G G-26-G G-27*G G 28-*G G 29 *G G-210-'G G-211-G 60 90 120 150 180 210 240 270 300 48 72 96 120 144 168 192 216 240 96 72 144 108 192 144 240 180 288 216 336 252 384 288 432 324 480 360 58 86 115 144 173 201 230 259 288 $234.00 291.00 335.00 376.00 412.00 454.00 496.00 527.00 573.00 $248.00 305.00 349.00 390.00 426.00 468.00 510.00 541.00 587.00 287 363 438 500 563 639 707 771 851 'Substitute letter "F" for flush or "0" for deluxe jecket. "IS" standard equipment: (see options, page 9) In addition to boiler for steam with "standard equipment" page 7, "IS" boilers are furnished with immersion operating control for use in storage tank. For ordering instructions for gas boilers, see page 15. Controls regularly furnished are for 115 volt. 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. * For discount on repairs, see page 2. HH-J Page g 01623 American-Standard HYDRO NIC HEATING BOILERS--GAS FIRED STEAM AND WATER G-2 OPTIONAL EQUIPMENT ALL BOILERS (Pages 5 thru 8): Runner type pilot ignition (or use with listed gases furnished at no charge when specified on order to meet local Utility codes. Push button electric ignition (or use with listed gases. Not available with self-energizing controls. Specify on order and add $11.85 to Trade Price of boiler. Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add $3.00 to Trade Price of boiler. Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual opening feature on V-600 or V-532 gas valves fur nished at no additional charge when specified on order to meet local utility codes. Zone control valve sets available for water boilers, for details and prices, see page 30. PACKAGED GAS BOILERS (Page 5 only): only those options listed above applicable to these boilers. PACKAGED ALL-PURPOSE BOILERS (Page 6 only): Tankless heaters: when boilers (4 thru 7 section) are to be used for forced circulation I=W=H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately only at the "sold separate" Trade Prices shown below. Self-energizing controls (consists of special gas valve, pilot burner, limit control) for mfd.. natural and mixed gas. avail able when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32. Room thermostat prices shown on page 32. ALL-PURPOSE BOILERS (Page 7 only): WATER BOILERS ONLY: Factory installed tankless heaters: when boilers (4 thru 11 sec tion) are to be used for forced circulation I=W=H tankless heaters can be specified factory installed, but limited to cer tain boiler sizes. See table below for I=W=H ratings and applicable boiler size. If desired, add suffix letter "T" to boiler number and "factory installed" Trade Prices shown below. ALL-PURPOSE BOILERS (Page 7 only): WATER BOILERS ONLY: (continued) Tankless heaters: when boilers (4 thru 11 section) are to be used for forced circulation I=W=H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below. STEAM BOILERS ONLY: McOonnell-Miller No. 101-24V Electric Water Feeder can be added to the No. 67 Low Water Cut-off furnished with G-2 All-Purpose Steam Boilers to provide Low Water Cut-off and Feeder Combination. If desired specify on order and add $37.07 to Trade Price of Steam Boiler. Side Outlet Pop Valve may be substituted at no additional charge if specified on order to meet local code requirements. WATER OR STEAM BOILERS: Self-energizing controls (consists of special gas valve, pilot burner, limit control, low water cut-off for steam boilers) for mfd., nat. and mixed gas, available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32. Room thermostat prices shown on page 32. Dual-gas boilers: available for both natural and propane gases. See below for added charges. Boiler prices on Page 7 boiler no. G-23 G-24 G-2S G-26 G-27 added charge $50.00 52.00 54.00 56.00 58.00 boiler no. G-28 G 29 G-210 G-211 added charge $60.00 62.00 64.00 66.00 Equipment includes in addition to standard trim two V-532 gas valves, two manifolds with spuds factory assembled, outdoor changeover control. G-2 Tankless Heaters boiler number G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211 Ratings A.CUL Input Btu/hr. heater i 218 IsWsH Rating e heater 222 heater 226 heater 4 232 90.000 120.000 150,000 180,000 210.000 240,000 270,000 300,000 2 Vi -- -- -- --3 ---- -- 3% -- -- -- 3 Vi 4 -- -- 3 Vi 4 Vi -- -- 3 Vi 4 Vi 4 Vi -- 3 Vi 4Vi 4% -- 3Vi 4Vi 5 Gallons watsr per minute heated from 40*F to 140*F with 200*F boiler water temperature. A lost two digits designate lineal feat of Tru Fin tubing in heater coil. Trad* Prices heater number 218 222 226 232 factory installed $41.00 43.00 51.00 55.00 sold separate $19.00 21.00 29.00 33.00 Factory installed additional price includes RS-116-F packed in tnm boa. Page 9 HH-3 01624 TOILERS--GAS FIRED fTCA* AND WATCt American-Standard HYDRONIC HEATING WATER boiler nvmhar 6403 6404 6-405 6-406 6407 6408 6409 64010 STEAM better amber 6403 6404 6405 6406 6407 6408 6409 64010 WATER bailer number 6403 6404 6405 6406 6407 6408 6409 64010 STEAM boiler amber 6403 6404 6405 6406 6407 6408 6409 64010 A.C.A. input Mbti 150 225 300 375 450 525 600 675 A.C.A. inpet Mbh 150 225 300 375 450 525 600 675 JLC.A. input Mbh 120 180 240 300 360 420 480 540 A.C.A. fnpat Mbh 120 180 240 300 360 420 480 540 G-40 AMERicAN-<Slandard CAS boilers For Built-In Water Heater Arrangement, see page II. Deluxe jacket. Tested and equipped for 50 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section). FOR NATURAL, A C A. output Mbh not l = B = Pt ratinf Mbh MFD., MIXED, GASES net ratine *0- tt. water Trade Price with standard equipment ONLY chimney sue diam. inches ht. ft. 120 900 600 $360 00 180 135 0 900 462.00 240 180.0 1200 567.00 300 225.1 1500 693.00 360 270.1 1800 788 00 420 315.1 2100 893.00 480 360.1 2400 977.00 540 405 1 2700 1071.00 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 A.C.A. tftput Mbh att 1 = 1 = A ratine Mbh sq. ft. Trade Price with standard equipment chimney sue diam. inches ht. ft. 120 90.0 180 135.0 240 180.0 300 225.1 375 $397.00 563 499.00 750 604.00 938 730.00 6 20 7 20 7 20 8 20 360 270.1 1125 825.00 8 20 420 315.1 1313 930.00 9 20 480 360.1 1500 1014.00 10 20 540 405.1 1688 1108.00 10 20 FOR LP AND LP-AIR GAS ONLY A.C.A. eutput Mbh net ratine Mbh nat ratine sq. ft. water Trade Price with standard equipment chimnay size diam. inches ht. ft. 96 72.0 480 $360.00 144 108.0 720 462.00 192 144.0 960 567.00 240 180.0 1200 693.00 6 20 7 20 7 20 8 20 288 216.1 1440 788.00 8 20 336 252.1 1680 893.00 9 20 384 288.1 1920 977.00 10 20 432 324.1 2160 1071.00 10 20 A.C.A. output Mbh 96 144 192 240 288 336 384 432 net 1 = 1 = R ratine Mbh 72.0 108.0 144.0 1803) 216.1 252.1 288.1 324.1 sq. ft. 300 450 600 750 900 1050 1200 1350 Trade Price with standard equipment $397.00 499.00 604.00 730.00 825.00 930.00 1014.00 1108.00 chimny size diam. Inches ht. ft. 6 20 7 20 7 20 8 20 8 20 9 20 10 20 10 20 apprex. thippinf wti|ht 827 998 1162 1349 1517 1686 1856 2026 epprei. shippmf weifht 858 1027 1195 1370 1544 1713 1880 2050 approx. shippmc weifht 827 998 1162 1349 1517 1686 1856 2026 approx. shippinc weicht 858 1027 1195 1370 1544 1713 1880 2050 Standard equipment includes: (see options, pages 11 and 15) V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves. Optional other gases at no additional charge); manual shut-off valve; pilot filter (mfd gas and SUR); gas pressure regulator (except for LP gas); boiler drains and pilot cocks; insulated jacket; draft hood; water heater opening cover plates. Water only: Theraltimeter; ASME relief valve for 50 lbs.; CB-655 immersion limit control. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off. Controls regularly furnished are for 115 volt. 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of \% tor each 1.000 feet above sea level. ' Room thermostat not included in above prices. For complete information on optional equipment, see pages 11 and 15. For ordering instructions for gas boilers, see page 15. __________________ * For complete information on boiler ratings, see page 2 For discount on repairs, see page 2. mh 3 Page 10 01625 American-(Standard HYDRONIC HEATING BOILERS - GAS FIRED STEAM AMO WATIR G-40 optional equipment BOILERS WITH TAKra.'r,* HEATERS: water (tor forced circulation) and steam boi<eps can be flushed with tankless heaters Some heaters are limited :o certain ooi.er sizes as shown m ratings table below Tankless heaters with controls for water boilers: RS 116 F packed m trim Bo m place o< CB 655 lor stanoaro equipment Tankless heaters with controls for steam boilers: additional CB 666 immersion operating control packed in trim box. If tankless heaters with controls are desired, specify on order with boiler and add to Trade Price of boiler with standard equipment the following charges Tankless heaters less controls will be furnished when specified at the Trade Prices shown below for heaters only. HEATER NO. 216 222 226 232 445 HEATER WITH CONTROLS Water Steam $41 00 43 00 51 00 55 00 72 00 S29 00 31 00 39 00 43 00 60 00 HEATER ONLY Water er Steam $19.00 21 00 29.00 33.00 50 00 Water flow regulators sized for tankless heater involved will be fur nished with heater when specified on order to meet local Utility require ment at S2 00 Trade Price additional charge per heater. Factory assembled sections: G-403 through G-406 can be shipped with sections factory assembled when specified on order. If desired less tankless heater, add SIS.00 to Trade Price of boiler if desired with fac tory installed tankless heater, specify heater number, and add 515.00 plus price of heater to Trade Price of boiler Dual Gas Equipment: available with steam or water boilers for use with Natural and Propane gases only In addition to standard trim, dual gas equipment includes tube withm a tube manifold, two V-S32 gas valves, gas pressure regulator (natural gas only), two manual shut-off valves, ribbon burners. 100% shut-off (consists of Baso combination pilot valve and switch with auxiliary Baso pilot valves), pilot cock, outdoor thermostatic adjustable changeover control. Boiler selection should be based on the A.G.A and i-BbR ratings shown for LP gas. If desired specify on order and add to Trade Price of boiler with standard trim the following charge: Boiler Number G-403 G-404 G-40S C-406 Add to Biller Trade Price 560 00 62.00 64 00 66 00 Boiler Number G-407 G-408 G-40 9 G-4010 Add to Boiler Trade Price $68.00 70 00 72.00 74.00 Electronic Control Systems: available with steam or water boilers. If desired refer to page 25 for complete details end additional Trade Price charges. F.M. and F.I.A. equipment: requires EG O or EPG-O electronic control system and special gas control equipment. Available price on appli cation. Tri-cock tappings and valves: if desired for steam boilers to meet local code specify on order and add 54 00 to Trade Price of steam boiler. Self-energizing controls: available for steam or water (gravity) less tankless heater for natural and mixed gases only Eouipment includes special gas valve, pilot burner, limit control, low water cut off for steam boilers Furnished at no additional charge when specified on order. Special room thermostat required, lor Trade Price see Page 32. McOonnell-Miller No. 101*24 Volt Electric Water Feeder can be added to No 67-GAR low water cut-off furnished with G-40 Steam Boilers to provide low water cut-off and feeder combination. If desired specify on order and add 537 07 to Trade Price of steam boiler McOonnell-Miller No. 47-2 low water cut-off and feeder combination may be specified in place of regularly furnished No. 67-GAR for steam boilers. If desired specify on order and add 533 00 to Trade Price of steam boiler. McOonnell-Miller No. 247-2 lew water cut-off and feeder combination for water boilers is available with G-40 Water Gas Boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price of this item shown m the current McOonnell-Miller Price Sheet. Runner type pilot ignition: all sizes of G-40 are available with Runner type pilot ignition for mfd., nat. and mixed gas non-100% shut-off at no additional charge when specified on order to meet local Utility codes Push button electne ignition: alt sizes of G-40 are available with push button electric ignition for use with mfd., nat. and mixed gas non-100% shut-off and will be furnished when specified on order at 511-65 added charge. Pilot filters for G-40 for natural and mixed gases available at no addi tionai charge when specified on order to meet local utility codes. Room thermostats available at Trade Prices shown on Page 32. "IS" Equipment: G-40 Gas Boilers can be furnished for use with In direct Steam Hot Water Supply systems. CB-666 immersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on Page 32. V-532 Diaphragm Gas Valve without manual opening may be substi tuted for V-531 Gas Valve with manual opening at no additional charge. If desired, specify on order. Side Outlet Steam Pop Valves may be substituted at no additional charge if specified on order to meet local code requirements. Jacket Extension: covers all controls on left end of boiler. If desired, specify on order and add $25.00 to Trade Price of Boiler. G-40 Tankless Heater Ratings (Gallons per minute9) Boiler 6-403 6-404 6-409 6-401 6-407 6-401 C-40B 6-4010 HEATER 211 Steam Water 34 3V5r 4 3V* 4 4 3V* 4 3Vi 4 3 V2 4 3V^ 4 MUTER 222 Steam _ 4 4 4 4 4 4 4 Water _ 4V* 4V4 46 4V* 4V* AVi 4V* MUTER 226 Stum -- '-- 5V4 5V* 6 6 6 6 Water -- -- 6 6 6Vi 6Vt 6V* 6V* MUTER 232 Steam -- -- -- -- 7 7 V* 7W 7V* Water -- -- -- -- VA 6 8 8 HEATER 44S Steam Water ------ ---- ---- ---- sv* 9 aw 9 8Vt 9 *Go//onf of wofer per minutt roued from 40*F. fo I40*F. toff two digits of heater numbers indicofe fineof feef of Tru-fin tubing in beater coif. Page 11 01626 HH 3 ftOlUfcS ---GAS -HUD fTtAJA tfATCft American-Standard :** C-V??-* O N I C ?H'CAT-1-Na 6-60 A'iEniCAN-Standard GAS BOILERS WATER Mlr number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G6031 G-6033 G-6037 G-6041 STEAM boilar number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G.6037 G-6041 A.CLA. Input Mbh 725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 S220 5800 A.GJt. input Mbh 725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800 ff r/ttfrea!. Mixed. Manufactured Gases Jacketed. Tested and equipped tor 50 lbs. water working pressure. Available tor 50 lbs. working pressure on special order. A.OJL output Mbh 580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640 not lsB=R ratine Mbh 435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5 net ratine sq ft wator 2900 3480 4060 4640 5220 5800 7030 8320 9590 10805 12010 12610 14410 16200 18010 19205 21635 24015 Trad* Price standard equipment $ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00 ehimnay il diam. in. ht ft n 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 A.GJt. output Mbh 580 696 812 928 1044 1160 1392 1624 1856 2088 2320 2436 2784 3132 3480 3712 4176 4640 not l=B =R ratine Mbh tq ft 435.1 522.1 609.2 696.2 783.2 870.2 1054.5 1248.3 1438.8 1621.1 1801.2 1891.3 2161.5 2430.1 2701.9 2880.4 3245.3 3602.5 1813 2176 2538 2901 3263 3626 4394 5201 5995 6755 7505 7880 9006 10126 11258 12002 13522 15010 Trado Price with standard equipment $ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00 ehimnay sizs diam. in. ht ft a 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 approx. weight 2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316 approx. swhiepipgihnte 2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346 Standard equipment includes: (see options, pages 14 and 15) V-S31 diaphragm gas valve with manual opening feature: Baso automatic pilot switch tor non-100% shut-off (100% shut-off controls consisting of Baso combination pilot switch and valve with auxiliary Baso pilot valves, optional at no additional charge); manual shut-off valve; pilot Alter (mfd gas and SUR): gas pressure regulator; boiler drains and pilot cocks; insulated jacket; draft hood; transformer. Water only: Theraltimeter and ASME relief valve for 50 lbs.; CB-655 immersion limit control. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are lor installations at sea level and at elevations up to 2.000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 14 and 15. For ordering instructions for gas boilers, see page 15. ___ For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-3 Page 12 01627 American-Standard HVhUOMIC HEATIN6 BOILUS-GAS FUtED rrtA* am wars* G-60 AMKRiCAN-f$tandard GAS BOILERS far Lr ana Lr-Air Sa vniy Jacketed. Tested and equipped for 50 lbs. water working pressure. Available for BO lbs. working pressure on special order. WATER Mltr number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G 6028 G-6031 G-6033 G-6037 G-6041 STEAM boiler number G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041 A. (LA. 'SSh 650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200 A.G.A. Input Mbh 650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200 A.GJL. output Mbh 520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160 A.Q.A. output Mbh 520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160 not l=6=R rating Mbh 390.1 468.1 546.1 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8 nt ratine q. ft. water 2600 3120 3640 4160 4680 5200 6240 7385 8545 9680 10765 11305 12920 14535 16150 17235 19360 21530 nat l=B sR rating Mbh 390.1 468.1 546.1 624.2 702.2 780.2 936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8 sq. ft. 1625 1950 2276 2601 2926 3251 3901 4617 5342 6051 6729 7065 8075 9084 10093 10773 12099 13458 Trad* Price with standard aqulpmant $ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00 2092.00 2408.00 2711.00 3020.00 3329.00 3533.00 3967.00 4296.00 4895.00 5184.00 5803.00 6421.00 chimnsy tlra diam. in. ht. ft. n 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 Trade Price with standard equipment $ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00 2129.00 2445.00 2748.00 3057.00 3366.00 3570.00 4004.00 4333.00 4932.00 5221.00 5840.00 6458.00 chimney tixe diam. in. ht. ft. ii 20 12 20 13 20 13 20 14 20 15 20 15 20 16 20 16 30 17 30 18 30 19 30 20 30 21 30 22 30 24 30 26 30 26 30 approx. shipping weight 2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316 approx. shipping weight 2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346 Standard equipment includes: (see options, pages 14 and IS) V-531 diaphragm gas valve with manual opening; 100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves); manual shut-off valve; gas pressure regulator (except for LP-gas); boiler drains and pilot cocks; insulated jacket; draft hood; transformer. Water only: Theraltimeter and ASME relief valve for 50 lbs.; CB-655 immersion limit control. Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For eleva tions above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 14 and 15. For ordering instructions for gas boilers, see page 15. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. P>( 13 HH-3 01628 BOILERS--GAS FIRED ITtAM AND WATIt Am e rican -Standard EtYDRONIC HEATING G-60 OPTIONAL EQUIPMENT Push button electric ignition: all sizes of G-60 are availabli with push button electric ignition for use with mfd.. nat and mixed gas non-lOO^c shut-off. and will be furnished when specified on order at the following added charges: boiler size added charge G-606 thru G-6011 $11.85 G-6013 thru G-6021 23.70 G-6022 thru G-6031 35.55 G-6033 thru G-6041 47.40 Pilot filters for G-60 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes. Room thermostats available at Trade Prices shown on page 32. McDonnell-Miller Low Water Cut-off No. 67-AR external type can be substituted for the regular No. 69 Low Water Cut-off on G-60 steam gas boilers at no additional charge. If desired, specify on order. `MS" Equipment: G-60 gas boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. CB-666 im mersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 32. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers. Tri-cock tappings and valves; if desired for steam boiler to meet local code specify on order and add $4.00 to Trade Price of steam boiler. G-60 available tested at 80 lbs. water working pressure when specified on order. Add S3 00 per section to Trade Price of water boiler. McDonnell-Miller No. 47*2 and 51*2 Low Water Cut-off and Feider combinations are available with G-60 steam gas boil ers m place of regularly furnished No 69 low water cut-off. when specified on order, at the following added charges to Trade Price of steam boilers with regular equipment: boiler number G-606 thru G-6011 G-6013 thru G-6041 combination number 47-2 51 2 added chargee $33.00 46.00 McDonnell-Miller No. 247-2 and 51-2 low water Cut-off and Feeder combinations for water boilers are available with G-60 water gas boilers when specified on order Add to the Trade Price of the water boiler with regular equipment the current Trade Price for these items shown m the current McDonnellMiller price sheet. F.M. and F.I.A. equipment: requires EG-0 or EPG-0 electronic control system and special gas control equipment. Available price on application. V-532 Diaphragm gas valve without manual opening may be substituted for V-531 Gas valve with manual opening at no additional charge. If desired specify on order. Side Outlet Steam Pop Valves may be substituted at no addi tional charge if specified on order to meet local code require ments. G-60 external water heater tappings: maximum size all sec tions IV4". Add to Trade Price of boiler $2 00 per section tap ping and $2.00 per jacket tapping. G-60 Right end steam trim tappings for pressure gauge and water column gauge glass furnished when specified on order at Trade Price additional charge of $10.00 per boiler. G-60 DUAL GAS BOILERS Natural and Propane Gases G-60 steam or water boilers are available with dual gas equipment using natural and propane gases. If desired specify on order and add the charge shown below to boiler with standard equipment. Selection of the boiler should be based on the A.G.A. and I=B=R ratings shown on page 12. boiler number add to boiler Trade Price boiler number add to boiler Trado Price G-606 G-607 G-608 G-609 G 6010 G-6011 G-6013 G 6015 G-6017 $ 95.00 100.00 105.00 110.00 115.00 120.00 145.00 165.00 185.00 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G 6037 G-6041 $205.00 225.00 240.00 270.00 300.00 350.00 375.00 445.00 480.00 Dual gas equipment: In addition to boiler with standard trim, dual gas boilers include: Two V-532 diaphragm gas valves: two manifolds; gas pres sure regulator (natural gas only); manual shut-off valves; ribbon burners; 100% safety shut-off (consists of Baso com bination pilot switch and valve with auxiliary Baso pilot valves); pilot cock; outdoor thermostatic adjustable change over control. Room thermostat not included in above prices. For ordering instructions for gas boilers, see page 15. HH3 Page U 01629 AMERiCAN-cStandard H Y FS R O N I C H E A T 1 ft1 /> BOILERS-GAS FIRED STUM AND WATt* G-40 AND G-60 ELECTRONIC CONTROL PANEL SYSTEMS Panel System EPG-0: Provides electronic supervision of each mittent elcclnc ignition of all pilots Complete automatic op eration of boiler. 100% safety shut-off Equipment includes: one main control pane! with 1 to 3 auxiliary panels pre-wired and factory assembled. Q-179-A flame rod and electric ig nition pilots, ignition transformer; V-495-B pilot solenoid valves RA-890-E electronic relay for each panel with 8 sec ond response timing and alarm contacts Sec additional charges below off Available for al! gases Electronic supervision of a pn- (T.I.M any bup^iuitun ot ail auxiliary pilots Mair.-cpTTor ana pilot burner gas supply turned off on pilot fj'lurf Cont'nucus flame pilot operation Equipment includes ore tr,;n control panel and for certain boiler sizes one auxiharv panel factory wired and assembled to main panel, Q-179-B rlamn rod primarv pilot <si with special adapter for thermocouple Baso auxiliary pilot burners; Baso 817-F-ll pilot valves with tRcrnocouples. RA-890-E elec tronic relay for each panel with d second response timing and alarm contacts See additional charges below Panel System EPG-1: Provides manual ignition, non-100%- shut-off Available for Natural. Mixed and Manufactured Gas only Electronic supervision of a primary pilot and thermo couple supervision of all auxiliary pilots. Mam burner gas supply onlv turned off on pilot failure. Continuous flame pilot operation Equipment includes- one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel. Q-179-B flame rod primary piloUs*. Baso auxiliary pilot burners: Baso 850-1 switches with ther mocouples; RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts See additional charges below Panel System EPG-2: Provides manual ignition. 100r; shut Panel System EPG-3: Provides intermittent electric ignition on a primary pilot and continuous flame auxiliary pilots with 100% shut-off Available for all gases Electronic supervision of a primary pilot and thermocouple supervision of auxiliary pilots Mam burner and pilot burner gas supply shut-off on pilot failure. Equipment includes- one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel, Q-179-A flame rod and electric ignition primary pilot's), primary pilot solenoid valves' V-495-B; Baso auxiliary pilot burner; Baso 817-F-ll pilot valves with thermocouples; 6000 volt secondary ignition trans former^); RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts See additional charges below. ADDITIONAL CHARGES--Trade Price Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment Panel System EPG-0 boiler number added charge Panel System EPG-1 boiler number added charge Panel System EPG-2 boiler number added charge Panel System EPG-3 botler number added charge G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G 6033 thru 6041 $163.00 177 00 177 00 359.00 538 00 718 00 G- 403 thru 4010 $150.00 G- 606 thru 6037 150.00 G-6041 281.00 Mfd gas only G 6028 thru 6037 $281.00 G- 403 thru 4010 $171.00 G- 606 thru 6037 171.00 G-6041 283 00 Mfd. gas only: G-6028 thru 6037 $283 00 G- 403 thru 4010 $185 00 G- 606 thru 6037 185 00 G-6041 334 00 Mfd. gas only: G-6028 thru 6037 $334.00 Panel System EPG-1 available for Natural. Mixed and Manufactured gases only Balance for all gases. G-40 AND G-60 ELECTRONIC CONTROL SYSTEMS (less Panels) The following systems <EG-0. EG-1. EG-2 and EG-3) are also available. but do not include factory wired and assembled control panel These systems provide the same function and are equipped with thesame basic parts 'less panel) as described for EPG-0. EPG-1.EPG-2. and EPG-3 System EG-0: (Same function as EPG-0 less panel ) See additional charges below System EG-1: (Same function as EPG-1 less panel.) See additional charges below. System EG-2: (Same function as EPG-2 less panel.) See additional charges below System EG-3: (Same function as EPG-3 less panel ) See additional charges below ADDITIONAL CHARGE$-Trade Price Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment Control System EG-0 boiler number added charge G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G 6013 thru 6021 G 6022 thru 6031 G-6033 thru 6041 $108.00 140.00 140.00 280.00 420.00 560.00 Control System EG-1 better number added charge G- 403 thru 4010 $ 86.00 G- 606 thru 6037 86.00 G 6041 173.00 Mfd. gas only: G 6028 thru 6037 $173.00 Control System EG-2 boiler number added charge G- 403 thru 4010 $ 96.00 G- 606 thru 6037 96.00 G-6041 175.00 Mfd. gas only: G 6028 thru 6037 $175.00 Control System EG-3 boiler number added charge G- 403 thru 4010 $113.00 G- 606 thru 6037 113 00 G-6041 227 00 Mfd. gas only: G 6028 thru 6037 $227 00 Control System EG-1 available for Natural, Mixed and Manufactured gases only. Balance for all gases. Ignition Cable: Trade Price per foot .... Flame rod wire: Trade Price per foot . . ................................................ $0.70 $0.40 Orders must specify: GAS BOILERS--Instructions for Ordering tl> Complete Boiler Number < 2 < Steam or water. <3) Equipment desired: Regular. "DW" or TS". etc (4) Type of gas <If LP-gas. whether butane or propane) 51 Btu (heat value of gas) and specific gravity '6> Elevation at point of installation if in excess of 2 000 feet. 17 * Pressure available at outlet of gas meter. Page 15 HH 3 01630 PACKAGED BOILER-BURNER UNITS WATIt Am e rican-^tan d ard H YDRONIC HEATING "APR" PACKAGED BOILER-BURNER UNITS Designed and equipped with controls for continuous forced circulation. Factory assembled with jacket and crated. Built-in air-separator in top section. WATER ONLY packaged unit number APR-72 APR-90 grots laflsR output Mbh e IssBsR burner capacity gph 72 0.70 90 0.90 nat IsBsR rating Mbh 54.0 67.5 not rating sq ft water 360 450 Trado Price with standard equipment $315.00 340.00 chimney size 8x8x 15 8x8x 15 Nozzle sizes, gph, furnished with APR packaged units: APR-72. 0.7S-60*S; APR-90. 0.8S-60*S. approz. shipping weight 306 344 Standard equipment all Units: Model DH-5R Arcoflame oil burner with sling mounting and factory installed 956 light sensing flame detector. CB-66815 constant ignition light sensing primary control. Unitized ceramic fiber refractory combustion chamber. Draft stabilizer. ASME relief valve. 1" circulator. Wiring harness and junction box. Drain valve and theraltimeter CB-580 thermostat and AY-553 limit control. Motors and controls regularly furnished for 115 volt. 60 cycle current. Note: APR units are shipped with jacket and electrical controls (except thermostat), com bustion chamber, circulator, factory assembled and wired. Arcoflame oil burner shipped separately. Draft stabilizer, relief valve and thermostat are secured inside boiler crate. Units furnished only as listed above. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-3 Page 16 01631 BOILER-BURNER UNITS OIL FIRED BOILERS UII Am e RicAN-<St andard HYDRONIC HEATING ARCOLEADER BOILER-BURNER UNITS Designed and equipped with controls for forced circulation. Flush jacket. Factory assembled sections "Elimmaire" (cast-in air eliminator in front section). WATER ONLY boiierbumcr unit number gross l = B=R output Mbh i=b=r burner capacity gph tankless heater number A l=W=H rating Units less factory installed tankless heater A1-3-B A1-4-B Al-5 B A1 6 B A1-7-B 100 0.95 136 1.30 173 1.65 208 1.95 244 2.30 Units with factory installed tankless heater A1-3-BT A1 4 BT A1-5-BT Al-6 BT Al-7 BT 100 0.95 732 3 Vx 136 1.30 732 4`/i 173 1.65 743 5`/2 208 1.95 743 6 244 2.30 743 6 net l=B=R rating Mbh 75 0 102.0 129 8 156 0 183.0 75.0 102.0 129.8 156.0 183.0 net rating sq ft water 500 680 865 1040 1220 500 680 865 1040 1220 Trade Price with standard equipment $351.00 420.00 497.00 561.00 637 00 $386.00 455.00 551.00 615.00 691.00 chimney size 8 x 8 x 15 8 x 8 x 15 8x8x15 8x8x15 8x12x15 8x8x 15 8x 8 x 15 8 x 8 x 15 8x8x 15 8 x 12 x 15 approa. shipping weight 586 726 882 1051 1197 596 740 906 1087 1233 Nozzle sizes, gph. 60* furnished with Arco'eader boiler burner units: A1-3-B. 0.90--H; A1-4B. 1.25-H; A1-5-B. 1 50-S. AI-6-B. 1.7S-S; A1-7-B. 2.00-S. AGallons of water per minute heated from 4CF to 140F with 200F boiler water temperature. Standard equipment all Units: (see options, page 19) Model DH-5 Arcoflame oil burner with sling mounting CB-704 constant ignition primary control. Draft stabilizer. ASME relief valve. Theraltimeter. Heat Lib-O-Rator high tempera ture steel combustion chamber Motors and controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for units with tankless heaters: Tankless heater as shown above factory installed in section assembly. No 36 Arcoflame control set (CB-520 thermostat, CB-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle. Additional standard equipment for units less heater: No 34 Arcoflame control set (CB-520 thermostat, CB-851 combination immersion controlhigh limit and circulator control) and nozzle. Heater opening cover plate. WATER ONLY ARCOLEADER OIL FIRED BOILERS Wet base construction Factory assembled sections. Flush jacket. `'Eliminaire" (cast-m air eliminator in front section) boiler number gross l=BsR output Mbh l=B=R burner capacity gph tankless heater number l = A W=H rating Boiler less factory installed tankless heater Al-3 A1-4 Al-5 Al-6 Al-7 100 0.95 136 1.30 173 1.65 208 1.95 244 2.30 Boiler with factory installed tankless heater A1-3-T A1-4-T A1-5-T Al-6 T A1 7 T 100 0.95 732 3 V. 136 1.30 732 4 >4 173 1.65 743 5>/2 208 1.95 743 6 244 2.30 743 6 net i=B=R rating Mbh 75 0 102.0 129.8 156.0 183 0 75.0 102.0 129.8 156 0 183 0 net rating q ft watar 500 680 865 1040 1220 500 680 865 1040 1220 Trade Price $230.00 299.00 376.00 440.00 516.00 $256 00 325.00 421 00 485.00 561.00 chimney size approa. shipping weight 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8x 12x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x12 x15 583 730 894 992 1138 593 744 919 1022 1168 AGallons of water per minute heated from 40F to MOF with 200F boiler water temperature. Standard equipment all boilers: (see options, page 19) Heat Lib-O-Rator high temperature steel combustion chamber. ASME Relief Valve. Theraltimeter Additional standard equipment boilers with tankless heaters: Tankless healer as listed above factory installed in section assembly. Not: Boilers less factory installs tankli-ss heater are shipped less water heater opening cover unless specified on order For complete information on boiler ratings, sec page 2 For discount on repairs, see page 2 01632 AMERiCAN-^Standard HYDRONIC HEATING PACKAGED BOILER-BURNER UNITS WATIR ARCOLEADER PACKAGED BOILER-BURNER UNITS Designed and equipped with controls for forced circulation. Factory assembled and crated. Wet base construction. Flush Jacket. "Eliminaire" (cast-in air eliminator in front section). WATER ONLY packaiid unit number grot* 1=B=R output Mm IsSsR humor capacity gph tankleaa hoator number l=W=H rating nat IsSsR rating Mbh not rating oq ft water Trade Price wtth ctandard equipment chimney also approx. shipping weight Packaged units less tankless heater A1-3P A1-4-P A1-5-P 100. 0.95 136 1.30 173 1.65 75.0 500 5447.00 8(8x 15 661 102.0 680 516.00 8x8 x 15 811 129.8 865 588.00 8x8x 15 959 Packaged units with factory installed tankless heater A1-3-PT A1-4PT A1-5-PT 100 0.95 732 3% 136 1.30 732 4Vi 173 1.65 743 5>/z 75.0 102.0 129.8 500 680 865 5478.00 548.00 633.00 Nozzle sizes, gph. 60* furnih*d with Arcoleadar packaged units: A1-3-P, 0.90--H; A1-4P. 1.25-H: A1-5-P. 1.50-S. Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. 8x8 x 15 8x8x 15 8x8x15 673 824 991 Standard equipment all Units: (see options, page 19) Model DH-5 Arcoflame oil burner with sling mounting. CB-706 constant ignition primary control. Draft stabilizer. ASME relief valve. Heat Lib-O-Rator high temperature steel com bustion chamber. iy" circulator with piping. Wiring harness. Drain valve. Theraltimeter. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for units with factory installed heater Built-in tankless heater as listed above. No. 36 Arcoflame control set (CB-520 thermostat, CB-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle. Additional standard equipment for units less heater No 34 Arcoflame control set (CB-520 thermostat, CB-851 combination immersion controlhigh limit and circulator control) and nozzle. Heater opening cover plate. NotcUnits are shipped with flush jacket and with all electrical controls (except thermostat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft stabilizer, relief valve and thermostat are secured inside boiler crate. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 17 HH-3 01633 : .^r jLXMsaatxm American-Standard HYDRONIC HEATING BOILER-BURNER UNITS OIL FIR5H BOILERS WATIK ARCOLEADER OPTIONAL EQUIPMENT PACKAGED BOILER-BURNER UNITS only: Jacket extension; it desired specify on order and add $28 00 to Trade Price of boiler Jacket extension, shipped in separate carton, provides 15^4" enclosure in front for concealment of oil burner and controls; approximate shipping weight 35 lbs. Two-stage fuel unit will be furnished when specified on order at $5 00 Trade Price extra Add-on No. 36-Z Arcoflame control set will be furnished when specified on order at $20 35 Trade Price extra lAdd-on zone Use only with No. 36 control set > Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30. BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following charges: Control Sot With Hoator Water control set No. 13 -- Water control set No. 36 -- Water control set No. 36-Z $20.35 (Add on zone Use only with No 36 control set.) Lets Hoator * $ 9.10 20.35 Boiler burner units less heater can be ordered tor use on gravity systems: Specify No. 13 Arcoflame control set and deduct $S 90 from Trade Price of unit less heater and specify water heater opening cover plate with 3** tapping. Detailed description of Arcoflame control sets is shown on page 32. CB-703 intermittent ignition primary control is available at $3.00 Trade Price extra. Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; it desired specify on order and add $28 00 to Trade Price ot boiler. Jacket extension provides 153/" enclosure in front for concealment of oil burner and controls. Approximate shipping weight 35 lbs. Oil fired boiler heater opening cover plate: furnished only when specified on order at no charge. If specified on order cover plate can be tapped 3" for gravity installations. BUILT-IN HEATERS: Built-in tankless heaters can be ordered for separate shipment with Boiler-Burner units or Oil Fired Boilers less factory installed tankless heaters at the following Trade Prices: Heater number 723 732 743 Trade Price $25.00 27.10 47.70 NOTE: for i--W--H ratings and boilers with which heaters can be used, see table below. Water mixing valves: for prices, see page 32. ARCOLEADER |=W=H RATED TANKLESS HEATERS Heaters tested with boilers. Built-in tankless heaters for Arcoleader Boiler-Burner units and Oil Boilers can be ordered for separate shipment with units or boilers specified less tankless heaters See Trade Prices above. Select heater desired from table below. unit or boiler size l=B = R burner capacity gph haatar 723 l=W=H rating haatar 732 haatar 743 Al-3 0 95 3 Vi 3% Al-4 1.30 3'/ 4 Vi Al-5 1.65 3 Vi 4 Vi Al-6 1.95 3 Vi 41,4 Al-7 2 30 3 Vi 4 Vi 5>/2 6 6 A Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature. For discount on repairs, see page 2. Page 19 HH-3 01634 BOILER-BURNER UNITS OIL FIRED BOILERS ITtAJN AND WATS! Am e rican and ard HYDRONIC HEATING ARCOLINER BOILER-BURNER UNITS Wet base construction. Flush jacket. Factory assembled sections. Arranged for but less Built-in Tank or Tankless Type Water Heater boiler-bumer unit numbtr STEAM WATER great l=8=R output Mbh l=8=R burner capacity nat l=B =R rating M ft stoam Mbh not rating *q ft water Trade Price wttti standard equipment WIDE BACK TYPE SO-153-B-T S-0-154-8T S-0155-B-T S-0156-BT W-0-153-BT W-0-154-B-T W-0-155-B-T W-0-156-B-T 97 1.00 303 72.8 485 132 1.35 413 99.0 660 164 1.60 513 123.0 820 188 1.80 588 141.0 940 $354.00 417.00 492.00 537.00 Nozzle SIMS, iph, 60*. furnished with Arcoliner Boiler-Burner Units ere is follows: No. 153. 0.90--H; No. 154, 1.25-H: No. 155. 1.50-S; No. 156. 1.65-S. Chimney alia 8 x 8 x 20 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25 approi. shipping weight 851 1010 1163 1394 Standard equipment: (see options, next page) Model DH-5 Arcoflame oil burner with sling mounting. CB-704 constant ignition primary control. Draft stabilizer. Heat Lib-O-Rator high temperature steel combustion chamber (no deduction for omission). Motors and controls regularly furnished are for 115 volt, 60 cycle current. Water only: No. 13 Arcoflame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve. Steam only: No. ll Arcoflame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings. ARCOLINER OIL FIRED BOILERS Wet base construction. Flush jacket. Factory assembled sections. Arranged for but less Built-in Tank or Tankless Type Water Heater boiler number STEAM WATER WIDE BACK TYPE greet l=8=R output Mbh l=8=R burner capacity ___ e*<____ net IsB =R rating aq ft ateam Mbh net rating eft water SO-153-T S-0154-T S-0-155-T S-0-156-T W-0-153-T WO-154T W-0-155-T W-0-156-T 97 1.00 303 72.8 485 132 1.35 413 99.0 660 164 1.60 513 123.0 820 188 1.80 588 141.0 940 Trade Price with tanderd equipment $228.00 291.00 365.00 410.00 Standard equipment: (see options, next page) Water. Theraltimeter and ASME relief valve. Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Chimney ixe 8 x 8 x 20 8x8x20 8 x 8 x 25 8 x 8 x 25 approx. shipping weight 772 930 1083 1234 Jacket extension shown a For complete Information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-4 Page 20 01635 American-^Standard hydronic heatinq BOILER-BURNER UNITS OIL FIRED BOILERS ST1AJA ANO WATII ARCOLINER OPTIONAL EQUIPMENT BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges: Control oot Added Charge Steam control setNo.12 .......................... $10.15 Water control setNo. 15............................. 22.75 Water control setNo. 16............................. 24.40 Water control set No. 16Z........................... 53.20 Water control setNo. 26............................. 24.40 Water control setNo. 34............................. 5.90 Detailed description of Arcoflame control sets is shown on page 32. CB-703 intermittent ignition primary control is available at $3.00 Trade Price extra. Two-stage fuel unit will be furnished when specified on order at $5 00 Trade Price extra. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. 450-BC-l Vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units see page 31 for added charge. The Heat Lib-O-Rator molded refractory type combustion chamber shown below for Arcoliner Boilers may be specified in place of steel chambers regularly furnished at no charge for No. 153-B-T or 154-B-T. Add to Trade Price for boiler No. 155-B-T $2.85 and for No. 156-B-T $5.75. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $27 SO to Trade Price of boiler Jacket extension provides 20W" en closure in front for concealment of oil burner and controls. Approximate shipping weight 47 lbs. Water mixing valves: for prices, see page 32. For low water cut-off lor use with steam units, see page 32. Molded refractory combustion chambers: available for Oil Boilers at Trade Prices below when specified on order. Cover plate for water heater opening will be furnished if specified on order at added Trade Price charge of $4.00. BUILT-IN HEATERS: Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Arcoliner Units. For detailed information on ratings, see page 2. Hooter No. 587 589 596 Hooter Typo tank tankless tankless Hooter Ratings gals. copocJty 85 3 per minute 3Vz per minute Trodo Prlco $22.60 29.90 35.00 approx. shipping walght 23 25 27 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS bollor numbor 153-T) 154-TJ 155-T 156-T Hoot Ub-O-Rotor modal no. No. 4 No. 5 No. 6 For discount on repairs, see page 2. max. firing rate gal. par hour 1.35 1.65 2.00 Troda Prtca $10.95 14.70 17.60 Page 21 approx. shipping wolght 77 86 90 HH-3 01636 BOILER-fiURNEBrllNITS' OIL FIREDjBOILER* JUHU)M:erMWW HO * ------- jiCaCit. t>o4lr-6umer unit number STEAM WATER (TOM l=B=R. output Mbh l=B=R bumor capacity *ph A net 1=8 =R rating o ft teem Mbh net retinc BO ft water Trade ` Price with standard equipment Arranged tor but less Built-in Tank or Tankless Type Water Heater chimney size approx. hipping weight S-84-OB S-85-OB S-86-OB S-87-OB S-88-OB S-89-OB W-84-OB W-85-OB W-86-OB W-87-OB W-88-OB W-89-OB 143 1.40 447 107.3 715 $456.00 175 1.75 547 131.3 875 520.00 202 2.00 631 151.5 1010 577.00 230 2.30 719 172.5 1150 261 2.55 816 195.8 1305 288 2.80 900 216.1 1440 636.00 704.00 760.00 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25 8 x 12 x 30 8 x 12 x 30 8x 12 x35 1338 1479 1603 1746 1863 2007 Nozzle Izet, fph, 60* $. furnished with Oakmont boiler-burner units: No. 84, 1-35; No. 65. 1.65; No. 86. 2.00; No. 87. 2.25; No. 88. 2.50; No. 89. 2.75. Standard equipment: (fee options, next page) Model OH-5 Arcoflame oil burner with sling mounting tor rear firing. CB-704 constant ignition primary control. Draft stabilizer. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omis sion listed on page 23. Motors and controls regularly furnished are for 115 volt, 60 cycle current Steam only: No. 11 Arcoflame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASMS safety valve, gauge glass and trimmings. Water only: No. 13 Arcoflame control set (CB-520 thermostat CB-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve. OAKMONT OIL FIRED BOILERS Flush jacket Arranged for but less Built-in Tank or Tankless Type Water Heater boiler number STEAM S-84 S-85 S-86 S-87 S-88 S89 WATER W-84 W-85 W-86 W-87 W-88 W-89 groee l=B=R output Mbh l=B=R bumor capacity CPh net 1=1 =R rating JSn team Mbh 143 1.40 447 107.3 175 1.75 547 131.3 202 2.00 631 151.5 230 2.30 719 172.5 261 2.55 816 195.8 288 2.80 900 216.1 a net rating *d water 715 875 1010 1150 1305 1440 Trade Price with standard equipment $323.00 386.00 441.00 498.00 566.00 622.00 chimney size 8x8x20 8 x 8 x 25 8 x 8 x 25 8 x 12 x 30 8x 12 x30 8 x 12x35 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water: Theraltimeter and ASME relief valve. approx. shipping weight 1109 1245 1352 1485 1602 1746 For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH3 Pag* 22 01637 Ame RTc^'^t an dafd H Y D R O N I C HEAT IN Q BOlLER.BURNkRtiNrrS OIL firEd boiIers IT tAJ*'AND'WAT I* OAKMONT OPTIONAL EQUIPMENT BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when speci fied on order at the following added charges: Centre! Set Added Ouip Steam control set Water control set Water control set Water control set Water control set Water control set No.12............................. $10.15 No.15............................ 22.75 No.16............................ 24.40 No.16-Z......................... 53.20 No.26............................ 24.40 No.34............................ 5.90 Detailed description of Arcoflame control sets is shown on page 32. CB-703 Intermittent ignition primary control is available at $3.00 Trade Price extra. Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. 450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam unitssee page 31 for added charge. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $3325 to Trade Price of boiler. Jacket extension provides 15%' en closure at rear for concealment of oil burner and controls. Approximate shipping weight 51 lbs. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32. Molded refractory combustion chambers; added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omis sion" Prices shown below and will be furnished when specified. Cover plate for water heater opening will be furnished if specified on order at added Trade Price charge of $4.50. BUILT-IN HEATERS: Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Oakmont units. For detailed information on ratings, see page 2. Heater No. 598 599 583 585 597 Heater Type tank tank tankless tankless tankless Heater Ratings gala, capacity 40 100 3 per minute 3 Vi per minute 4Vi Per minute Trada Prica $16.00 24.20 38.00 40.50 60.00 approx. shipping weight 23 27 83 104 92 unit number 84 85 86 871 88> 891 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS Heet Ub-O-Rator model No. Included No. 00 No. 1 No. 2 No. 3 maximum firing rate gallons per hour 1.50 1.75 2.25 3.00 deduct for omission $17.85 18.85 20.85 22.85 approx. shipping weight 148 153 170 180 For discount on repairs, see page 2. Page 23 HH3 01638 BOlUg-BURijEJL UNITS OILf^RED;OILERS ITIAMAND.W^IU HYDRONIC HEAT I N 0 SEVMcK TOILER-BURNER UNITS Flush jacket. bollsr-burner unit number -- -- - -i 1 STEAM I WATCH | i e>w>> ' i output 1 t.Sbh NOT TAPPED FOR BUILT-IN TAKH S I 7 0S S-210B S-25-OB S-29-OB S-33-OB S-37-OB W17-OB W-210B W250B W-29-OB W-33-OB W-37-OB 146 168 188 216 247 278 ]* < uiug | ' rata 1 n>h , _ Installed radiation ^ q ft atoam Mbh aq ft water WATER H EATER (se a options) 1.5 1.7 1.9 2.2 2.5 2.8 456 525 588 675 772 869 109.5 126.0 141.0 162.0 185.3 208.6 730 840 940 1080 1235 1390 | I | _ Trade_ standard equipment $489.00 529.00 570.00 613.00 677.00 735.00 j | shipping 1 weight 1303 1458 1570 1710 1815 1975 ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER S-17-OB-T W-17-OB-T 146 1.5 456 109.5 730 $495.00 S-210B-T W-21-OBT 168 1.7 525 126.0 840 535.00 S-250BT W-25-OBT 188 1.9 588 141.0 940 576.00 S-29-08-T W-29-OB-T 216 2.2 675 162.0 1080 619.00 S-3308-T W-33-OB-T 247 2.5 772 185.3 1235 683.00 S37-OB-T W-37-OB-T 278 2.8 869 208.6 1390 741.00 *Nozzle sues, *Ph 60*$. furnished with Severn boiler-burner units: No. 17. 145; No. 21. 1.50; No. 25. 1.75; No. 29. 2.00; No. 33. 2.25; No. 37. 2.50. 1312 1461 1579 1719 1824 1984 Standard equipment: (see options, next page) Model DH-6 Arcaflaroe oil burner with sling mounting tor front firing. CB-704 constant ignition primary control. Draft stabilizer. Heat Lib-O-Rator refractory combustion chamber: model number and deduction for omis sion listed on page 25. Motors and controls regularly furnished are for 115 volt. 60 cycle current. Steam only: No. 11 Arcoflame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge. ASMS safety valve, gauge glass and trimmings. Water only: No. 13 Arcoflame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve. SEVERN OIL FIRED BOILERS Flush jacket. boiler-number STEAM | , WATER Mrtput Mbh rate installed radiation sqtt steam Mbh sq ft water NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (ee options) S-17-0 S-21-0 S-25-0 S-29-0 S 33 0 S-37-O W-17-0 W-21-0 W-25-0 W-29-0 W-33-O W-37-0 146 1.5 456 109.5 730 168 1.7 525 126.0 840 188 1.9 588 141.0 940 216 2.2 675 162.0 1080 247 2.5 772 185.3 1235 278 2.8 869 208.6 1390 ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER S-17-0-T S-21-0-T S-25-O-T S-29-0-T S-33-0-T S 37-O-T. W-17-O-T W-21-O-T W-25-0-T W-29-OT W-33-O T ` W-37C 146 168 188 216 247 278 1.5 1.7 1.9 . 2.2 2.5 2.8 456 525 588 . 675 772 869 109.5 126.0 141.0 162.0 165.3 208.6 730 840 940 1080 1235 1390 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water. Theraltimeter and ASME relief valve. Trade Price with standard equipment $355.00 395.00 434.00 477.00 539.00 597.00 $361.00 401.00 440.00 483.00 545.00 603.00 a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-l Pag. 24 ppm. shipping wight 1075 1230 1325 1465 1560 1720 1084 1239 1334 1474 1569 1729 01639 --r-r~V-p: \ AME^ieAN-^tand^rd HYDROKICHEATINO ---- -*-**--,-------------------- ------- ------- .-v <- : SEVERN OPTIONAL EQUIPMENT BOILER-BURNER-UNITS OIL FIREDj BOILERS fTIAM AND WATI* BOILER-BURNER UNITS only: Arcoflame control sets other than those included In Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges: Control Sat Added Charge Steam control set No. 12.............................. $10.15 Water control set No. 15............................. 22.75 Water control set No. 16............................. 24.40 Water control set No. 16-Z........................... 53.20 Water control set No. 26 .............................. 24.40 Water control set No. 34............................. 5.90 Detailed description of Arcoflame control sets is shown on page 32. CB-703 Intermittent Ignition primary control is available at $3.00 Trade Price extra. Two-ttage fuel unit will be furnished when specified on order at $5.00 Trade Price extra. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. 450-BC-l vapor limit control: If desired in place of 450-BA-l pressure limit control regularly furnished for steam unitssee page 31 for added charge. BOILER-BURNER UNITS or OIL FIRED BOILERS: Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32. Molded refractory combustion chamber added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omission" Prices shown below and will be furnished when specified. Cover plate for water heater opening will be furnished if specified on order lor "T" type boiler at an added Trade Price charge of $3.T0. BUILT-IN HEATERS: If 2>/' right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of unit or boiler. Below are the ratings and Trade Prices covering Built-in tank or tanlrl> heaters available for Severn units. For detailed information on ratings, see page 2. Haator No. 703 594 595 590 Haator Typo tank tank tank tankless Hoatar Ratings gal*, capacity 66 100 160 3V4 per minute Trada Plica $ 9.00 48.00 42.50 36.00 approx. shipping walgtit 7 54 51 60 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit rmmiar Haat UMMtator modal No. Ineludod maximum firing rata gallon* par hour doduct for ml talon approx. flipping waifht 17, 21 25. 29 33. 37 No. 1 No. 2 No. 3 1.75 2.25 3.00 $18.85 20.85 22.85 153 170 180 For discount on repairs, see page 2. Page U HH3 01640 AA*ERipAN-<$tandard HYDRO NIC. HEAT!?: O BOIUR-BURNER UNITS OIL FIRED-BOILERS STUM AND WATU.' A-5 OPTIONAL EQUIPMENT BOILER-BURNER UNITS onlyt Arcoflame control seta other than thoae Included In Trade Price of boiler-burner unite will be furnished when specified on order at the following added charges: Central Set Added Chaise Steam control set No. 12.................... $10.15 Water control set No. 34.................... 5.90 Water control set No. 36 ................... 15.05 Water control set No. 36-Z................. 20.35 (Add-on zona. Usa only with No. 36 control sot) Detailed description of Arcoflame control sets is shown on page 32. C8-703 intermittent Ignition primary control is available in stead of CB-704 for A-504 thru A-509 at $3.00 Trade Price extra. Electronic flame safeguard equipment* 62A-70KF ell burner with electronic flame safeguard control Is avail able instead of 62A-70S6 burner for A-507, A-SOt and A-SOS boiler, burner units st added Trado Prlca charge of $93.00. The electronic con trol consist! of C7013A photocall Installed in burner. Q270A safety switch base mounted on burner housing, RA690E safety switch packed with burner delayed oil valve Installed between fuel unit and drawer assembly. For installations requiring Factory Mutual Approval and in statea and municipalities with regulations more stringent than Underwriters' Lab oratories. Inc., oil burners are available with special electronic flame safeguard controls for A-S boiler-burner units as follows: 62-A-70S6 FFM oil burner for A-507. A-509 and A-509 boiler-burner units, at addtd Trad# Prlca charga of $133.00. 96-7507 oil burner for A-S10 and A-511 boiler-burner units at addtd Trade Price charge of $30.00. Motors and controls regularly fumishad are for 115 volt. 60 cycle. 450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units-- see page 31 for added charge. Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30. Two-stage fuel unit for DH-5 Arcoflame oil burner will be furnished when specified on order at $5.00 Trade Price extra. BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; if desired specify on order and add $33.85 to Trade Price of boiler. Jacket extension provides 25' en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbf. Water mixing valves; for prices, see page 32. For tow water cut-off for use with steam units, see page 32. Molded n;W.!.y t-.ibustion chambers for A-5 boilers: Trade Prices re sr me ui "Deduct for Omission" Prices shown below. If desired, provision for tankless heaters is available at no additional charge. When suffix letter "T** is added on order to unit or boiler numbers, the following number of openings in center sections will be furnished. UnK No. Openings A-504-T 2 A-505-T thru A-508-T 3 A-509-T thru A-511-T 4 Note: Additional openings can be specified on order. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $3.35 each. NO. 530 TANKLESS HEATER: No. 530 tankless heater available In single or quantity lot price at $30.65 Trade Price each. The following table shows the recommended number of heat ers to be used with each boiler and the ratings attained if more than one heater is connected in parallel: boilar no. All Sizes All Sizes A-505--A-511 A-508--A-511 A-510--A-511 na. of hastars 1 2 3 4 5 raUng-gpm 4 7 10 13 16 Note: Additions! haatart can ba addtd H tha Matari ara aarving diffarnt systams and It is not llkaly that hsatare will all ba in usa at tha aama tima. -Gallons of watar par mlnuts raisad from 40 F to 140 F with 200 F boilar watar tamparatura. Copper pipe manifolds factory assembled for multiple heater parallel hookup shipped in boxes of two manifold assemblies per box when specified with heaters are available at the fol lowing charges: Manifold astombfy 2 heater 3 heater 4 heater Trado Prlca par Box $4.80 6.80 8.80 HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit numbor A-504 A-505 A-506, A-507. A-508 A-509. A-510. A-511 Haat Ub-O-IUtor modal No. Indudod 14-A 15-A 16-A 17-A maximum firing rata gallon* par hour 2.55 3.30' 5.55 7.65 daduct for omission $24.85 25.00 33.00 38.00 approx. shipping walght 158 163 180 200 For discount on repairs, see page 2. Page 27 HH-3 01642 BOILER-BURNER UNITS OIL FIRED'BOILERS mu AND WATIt A^ERicAk-^tand^rd K VTRONIC HE?Ar.i:0 A-5 BOILER-BURNER UNITS bollrvbumr unit number STEAM | WATER Flush ticket Tested and equipped for SO lbs. water rrooVing pressure. grow IsBsR output MMi e IsBsR buffnor capacity not IsBrR rating attain Mbh ratifiC watir Trad* Prica wtth qulpmtnt chlmnay alia appro*. shipping weight For Built-In Water Heater Arrangement, see page 27. A-504-SB A-505-SB A-506-SB A-507-SB A-508-SB A-509-SB A-510-SB A-511-SB A-504-WB A-505-WB A-506-WB A-507-WB A-508WB A-509-WB A-510-WB A-511-WB 261 2.55 816 195.8 1305 346 3.30 1082 259.6 1731 426 4.00 1332 319.6 2131 508 4.75 1588 381.1 2541 588 5.55 1838 441.1 2941 668 6.30 2088 501.1 3341 748 7.00 2338 561.1 3741 830 7.65 2594 622.7 4151 $ 700.00 844.00 952.00 1068.00 1153.00 1248.00 1443.00 1528.00 8x 12 x 15 8 x 12 x 20 12 x 12 x 20 12 x 12 x 20 12 x 16x25 12 x 16 x 25 12 x 16 x 25 16 x 16 x 30 1702 1969 2286 2563 2807 3107 3382 3684 Nozzl. il, sph. furnished with A-S units srs as follows: No. A-S04. 1 2.SO 60*S: A-505. 2 1.65 70*S; A-506 2 2.00 70*S: A-507 1 2.25 4 l 2.50 S0*S: A-508 2 2.75 S0*S: A-509, 1 3.00 4 1 3.25 60*$; A-510 2 3.50 80*S; A SU 1 3.50 4 1 4.00 80*S. Standard equipment: (see options, next page) DH-S sling mounted oil burner for A-504, with 1-stage fuel unit. 4SW-3606 oil burner for A-505, A-506; 62A-7056 oil burner for A-507, A-508, A-509; 45W-3606 and C2A.-70M, flange mounted, with 2-stage fuel unit. The above burners are furnished with CB-704 constant ignition primary control. 96-7506 oil burner for A-510, A-511; flange mounted, with 2-stage fuel unit; electronic flame safeguard control consisting of C7013A photocell installed in burner; Q270A safety switch base mounted on burner housing; RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly. Draft stabilizer. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omission listed on page 27. Motors and controls regularly furnished are for 115 volt. 60 cycle current. Steam only: No. 11 Arcoflame control set (CB-520 thermostat. 450-BA-l pressure limit control) and nozzle (s). Steam gauge. ASME safety valve, gauge glass and trimmings. Water only: No. 13 Arcoflame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzle (a). Theraltimeter and ASMS relief valve for 50 lbs. A-5 OIL FIRED BOILERS Flush jacket. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER IsCfrolsaRs output IsBsR burner capacity CPU a*sti=B =R rating sen staam Mbh nst rating water Trada Met For Built-in Water Heater Arrangement, see page 27. A-504-S A-505-S A-506-S A-507-S A-508S A-509-S A-510-S A-511S A-504-W A-505-W A-506-W A-507-W A-508-W A-509-W A-510-W A-511-W 261 2.55 346 3.30 426 4.00 816. 1082 1332 195.8 259.6 319.6 1305 1731 2131 $ 560.00 660.00 760.00 508 4.75 1588 381.1 2541 588 5.55 1838 441.1 2941 668 6.30 2088 501.1 3341 860.00 945.00 1030.00 748 7.00 2338 561.1 3741 830 7.65 2594 622.7 4151 1115.00 1200.00 Standard equipment: (see options, next page) Steam: Steam gauge, ASMS safety valve, gauge glass and trimmings. Water. Theraltimeter and ASME relief* valve for 50 lbs.___________ eFor complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-3 Page 26 chlmnay size 8x 12 x 15 8 x 12 x 20 12 x 12 x 20 12 x 12 x 20 12 x 16 x 25 12 x 16 x 25 12x16x25 16 x 16 x 30 appro*. shipping weight 1489 1750 2050 2306 2550 2825 3075 3377 01641 BOILER-BURNER UNITS OIL FIRED BOILERS fTUM AMD WATII Am e rican-Standard HYPBOHIC HEAT IK 01 A-7 BOILER-BURNER UNITS Jacketed and unjacketed Tested and equipped lor SO IDs. water worKing pressure. boiler-burner unit number STEAM WATER grots IsBeR output Mbh l=B=R burner capacity net 1= B = R rating sq ft steam Mbh net rating sq ft water chimney size unjacketed jacketed Trade Price appro t. Trade Price approx. with standard zhlppmg witn standard shipping equipment weight equipment weight A-705 SOB A-706-SOB A-7Q7-SO-B A-708SO-B A-709SO-B A-710-SO-B A-711-SO-B A-712SOB A-713S0-B A-714 SO B A-705-WOB A-706-WO-8 A-707-WO-B A-708-W0-B A-709-W0-B A-710-WO-B A-711-WO-B A-712-W0-B A-713-WO-B A-714-WO-B 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 4331 5061 5981 6944 8020 9075 10125 11118 12112 13105 16 x 16x28 16 x 16x30 16 x 20 x 36 16 x 20 x 42 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 $163300 175300 1928.00 2277.00 2429.00 2607.00 2804.00 2974.00 3297.00 3469.00 4231 4883 5532 6283 6919 7603 8195 8871 9613 [0341 51714.00 1846.00 2033.00 2394.00 2558.00 2748.00 2957.00 3139.00 3474.00 3658.00 4403 5058 5715 6492 7134 7822 8456 9169 9883 10611 Nozzle sizes, sph. 80*S. furnished with A-7 units are as follows: A-70S. 2 4.00; A-706. 1 4.50, 1 5.00; A-707, 2 5 50; A-708 1 4.00. 2 4.50; A-709. 1 4.50. 2 5.00; A-710. 1 5.00. 2 5-50; A-711. 3 6.00; A-712. 3 6.S0; A-713, 2 5.00. 1 11.00; A-714, 2 5.50. 1 12.00. Standard equipment: (see options/ next page) 96-7508 oil burner for A-705, A-706. A-707; 97-7606 oil burner for A-708, A-709, A-710. 98-7706 oil burner for A-711, A-712; 97A Hi-Lo 7668 for A-713, A-714. All with pedestal mounting; two-stage fuel unit; electronic flame safeguard control consisting of C7013A photocell installed in burner. On model 96-7508 burner, Q270A safety switch base is mounted on burner housing. On models 97-7606. 98-7706 and 97A Hi-Lo 7668, W415B1 panel is furnished with Q270A safety switch base and R408E load relay. On all models, RA890E safety switch is packed with burner; delayed oil valve on models 96. 97 and 98 installed between fuel unit and drawer assembly. 3 delayed oil valves installed on model 97A Hi-Lo. Draft stabilizer. Steel pedestal base in addition to regular 12" base: 8" height for 5 through 7 section; 10" height for 8 through 14 section. Steam only: No. 11 Arcofiame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzles. Steam gauge, ASME safety valve, gauge glass and trimmings. Water only: No. 13 Arcofiame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzles. Theraltimeter and ASME relief valve for 50 lbs. Combustion chamber not furnished. See Installation-Operation and Maintenance Man ual for combustion chambers for A-7 boiler-burner units. A-7 OIL FIRED BOILERS Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER grots |=B = R output Mbh IsBsR burner capacity fph net 1 = B = R rating sq ft steam Mbh net rating sq ft water A-705SO A-706SO A-707-SO A-708SO A-709 SO A-710-SO A-711-SO A-712-SO A-713-SO A-714S0 A-705-WO A-706-WO A-707WO A-708W0 A-709-WO A-710WO A-711-WO A-712-WO A-713W0 A-714-WO 866 1012 1196 1376 1570 1760 1956 2148 2340 2532 8.15 9.55 11.25 12.90 14.65 16.30 18.00 19.65 21.45 23.20 2707 3163 3738 4340 5013 5672 6328 6949 7570 8191 649.7 759.2 897.2 1041.6 1203.1 1361.2 1518.6 1667.7 1816.8 1965.8 4331 5061 5981 6944 8020 9075 10125 11118 12112 13105 chimney size 16 x 16x28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80 unjscketed jacketed approz. approz. Trade Price shipping Trade Price shipping weight weight $1260.00 1380.00 1555.00 1725.00 1877 00 2055.00 2227.00 2397.00 2567.00 2739.00 3882 4518 5149 5720 6330 6990 7556 8208 8912 9616 $1341.00 1473.00 1660.00 1842.00 2006.00 2196.00 2380.00 2562.00 2744.00 2928.00 4054 4693 5332 5929 6545 7209 7817 8506 9182 9886 Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water. Theraltimeter and ASME relief valve for 50 lbs. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 28 01643 American-cStandard HYDRONIC HEATING BOILER-BURNER UNITS OIL FIRED BOILERS ITIAM AND WATIt A-7 optional equipment BOILER-BURNER UNITS only: Electronic flame safeguard equipment: For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories, Inc., oil burners are available with special electronic flame safeguard controls for A-7 boiler-burner units as follows: 96-7509 oil burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00. 97-7607 oil burner for A-708, A-709 and A-710. 98-7707 for A-711 and A-712, and 97A Hi-Lo 7669 for A-713 and A-714 boiler-bumer units at added Trade Price charge of $13.50. 450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units-see page 31 for added charge. Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30. Arcoflame control sets: detailed description is shown on page 32. BOILER-BURNER UNITS or OIL FIRED BOILERS: Water mixing valves: for prices see page 32. McDonnell-Miller No. 47-2 and No. 51-2 low water cut-off and feeder combinations: No. 47-2 used with A-705 through A-707 and No. 51-2 used with balance of sizes. Special equalizer tap ping for bottom connection of No. 51-2 located 6 inches below water line on front section. Specify No. 47-2 or No. 51-2 on order and add to Trade Price of steam boilers with standard equipment Trade Price for these items shown in the current McDonnell-Miller price sheet. For No. 369 low water cut-off for use with steam units, see page 32. OIL FIRED BOILERS only: Steel pedestal bases for installation under the regularly furnished 12" base for greater base heights will be furnished when specified on order at the following added charges: taction tJza 5 through 7 6 through 14 bat* 8" 10" addad eharffo $46.00 76.00 Pin 29 01644 HH- 3 OIL BURNERS ZONE CONTROL SETS Ame rican-$t an dard HYORONIC HEATING OIL BURNERS for 115 volt 60 cycle current For Arcoleader, Arcoliner, Oakmont, Severn, A-5 and A-7 boilerburner units modal number gil. par hour air tube length diem. mounting Trade Price approK. shipping waight including CB-704 constant ignition primary control DH-5 .65- 3.00 5 4 sling DH-6 .65- 3.00 6 4 sling 45W-3606 3.00- 4.00 7V, 4>/* flange 62A-7056 4.00- 7.00 10`/ 6>/s flange 62A-7056 4.00- 7.00 10`/s 6% flange $115.15 115.15 159.00 175.00 180.00 55 55 56 77 82 including electronic flame safeguard control 96-7506 6.00-12.00 ioy 6*/g 96-7508 6.00-12.00 10/s 6>/g 97-7606 10.00-17.00 ioy* 7 98-7706 14.00-20.00 10V4 8 97A Hi-Lo 7668 10.00-24.00 10'/a 7 Vi flange pedestal pedestal pedestal pedestal 290.00 327.00 476.00 501.00 654.00 107 145 208 208 223 The above prices are for oil burners with primary control as shown. No. 11 steam or No. 13 water basic control set with CB-520 thermostat, and nozzle (s). 62A-7056 burner supplied with 9" dralt stabilizer lor A-507 and A-508. and with 12* dralt stabilizer lor A-509 boilerburner units. OH-5 burner for Arcoleader, Arcoliner and Oakmont boilerburner units is shipped with pressure ring only. Primary control is shipped installed with Arcoleader Packaged units and is a separate shipping component with Arcoleader, Arco liner and Oakmont boiler-burner units. DH-5 burner for A-504 boiler-burner unit is shipped with CB-704 primary control and mounting accessories. DH-6 burner for Severn boiler-burner units is shipped with CB-704 primary control. Accessories for Severn are shipped in a separate box. 45W-3606 burner for A-505 and A-506. and 62A-7056 burner for A-507 through A-509 boiler-burner units are shipped with CB-704 primary control and mounting accessories. 96-7506 burner for A-510 and A-511, and 96-7508 burner for A-705 through A-707 boiler-burner units are shipped with electronic flame safeguard control consisting of C7013A photo cell installed in burner. Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner. 97-7606 burner for A-708 through A-710, 98-7706 burner for A-711 and A-712, 97A Hi-Lo 7668 burner for A-713 and A-714 boiler-burner units are shipped with electronic flame safe guard controls consisting of C7013A photocell installed in burner. W415B1 panel furnished with Q270A safety switch base and R488E load relay; RA890E safety switch packed with burner. Delayed oil valve on 96, 97 and 98 burners is installed be tween fuel unit and drawer assembly; 3 delayed oil valves installed on 97A Hi-Lo burner. OPTIONAL ELECTRONIC FLAME SAFEGUARD CON TROL EQUIPMENT: 62A-7056F burner with electronic flame safeguard control is available instead of 62A-7056 burner for A-507, A-508 and A-509 boiler-burner units at added Trade Price charge of $93.00. The electronic control consists of C7013A photocell in stalled in burner, Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly. For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories. Inc., oil burners are avail able with special electronic flame safeguard controls for boiler-burner units as follows: 62A-7056FFM burner for A-507, A-508 and A-509 boilerburner units at added Trade Price charge of $133.00. 96-7507 burner for A-510 and A-511, 96-7509 burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00. 97-7607 burner for A-708, A-709 and A-710, 98-7707 burner for A-711 and A-712, 97A Hi-Lo 7669 burner for A-713 and A-714 boiler-bumer units at added Trade Price charge of $13.50. Two-stage fuel unit is available for DH oil burners at $5.00 Trade Price extra. Two-stage fuel unit is regularly furnished with 45W, 62A, 96, 97, 97A Hi-Lo and 98 oil burners. Delayed oil valves are standard on all the above burners with electronic controls. V4001A valve is available installed on 45W and 62A burners at $13.00 Trade Price extra. If CB-703 intermittent ignition primary control is wanted, add $3 00 to Trade Price of boiler-burner unit regularly fur nished with CB-704 or CB-706 control. For optional control sets and added charges, see page 32. ZONE CONTROL SETS: Using Hydronic Zone Valves Two-zone and three-zone control sets uUlize one CB-520 thermostat furnished with Packaged G-2 Gas Boilers and Arcoleader Packaged boiler-burner unlta. When these sets are to be used with other forced hot water installations using circulator, it will be necessary to secure an addiUonal CB-520 thermostat to control the first zone. Sat No. 2-Z For Two Zonoo Sot No. 3-Z For Three Zones Sat No. 4-Z For Each Zone in Addition to Three Zones ContanU of Sat No. 2-Z: 1 CB-520 Round Thermostat 2 V8031B V sweat M-H Zone Valves 1 40VA Transformer Contents of Set No. 3*Z: 2 CB-520 Round Thermostats 3 V8031B sweat M-H Zone Valves 1 40VA Transformer Contents of Add-on Set No. 4-Z: 1 CB-520 Round Thermostat 1 V8031B sweat M-H Zone Valve 1 40VA Transformer Trade Price $45.19 Trade Price $70-57 Trade Price $27.45 HH-3 Page 30 01645 AMERicAN-cSlandard HYDRONIC HEATING OIL BURNERS OIL BURNERS for 115 volt 60 cycle current For conversion and replacement model number capacity sal. par hour air tuba length diam. including CB-704 constant ignition primary control mounting (pacify If pedestal or flange ft wanted for OH and 52A burners.) with control set Trade Price with primary controi and nozzle(s) only app- ship, welxht burner with no2il*(*) only e with controi set DH 8 .65-3.00 8 4 / pedestal 1 $115.15 DH-15 .65-3.00 15 4 ) or 1 117.15 DH-23 52A .65-3.00 23 4] 1 3.00-4.00 7% or 103/ 4`/a ( flange / 118.15 155.00 62-1-7000 4.00-7.00 16% 6% pedestal 170.00 $100 50 102.50 103.50 139.00 154.00 $ 75.00 77.00 78.00 113.50 128.50 60 65 65 65 73 NOTE: Optional air tuba length* are available for 52A burner. Add to Trade Price for 16V" length $3 50; for 22*/" length $5.50. including electronic flame safeguard control 62-2-7002 5.00- 8.00 96-7501 6 00-12.00 97-7601 10.00-17.00 98-7701 14.00-20.00 97A Hi-Lo 7650 10.00-24.00 16% 16% 16>/t 16% 16% 6% pedestal 275.00 259.00 6% pedestal 290.00 274.00 7 pedestal 476.00 460.00 8 pedestal 501.00 485.00 7l/a pedestal 654.00 638.00 _ 83 -- 91 -- 168 -- 168 -- 180 Deduct from shipping weight of burner with control set: Less control set 3 lbs. Less control set and less primary control 9 lbs. The above prices for burners with control set include primary control as shown; No 11 steam. No. 13 or No. 14 water, or No 19 warm air control set with CB-520 thermostat, as speci fied on order. For optional control sets and added charges, see page 32. For burners shown above with primary control and nozzle(s) only, and with nozzle(s) only, additional controls are available at Trade Prices shown on page 32. DH-8, DH-15, DH-23, 52A and 621-7000 burners are fur nished with CB-704 constant ignition primary control. On models with electronic flame safeguard controls, C7013A photocell is installed on burner. On 62-2-7002 and 96-7501, Q270A safety switch base is mounted on burner housing. On 97-7601, 98-7701 and 97A Hi-Lo 7650 burners, W415B1 panel is furnished with Q270A safety switch base and R488E load relay; RA890E safety switch is packed with burner. Delayed oil valve on 96, 97 and 98 burners is installed be tween fuel unit and drawer assembly; 3 delayed oil valves installed on 97A Hi-Lo burner. OPTIONAL ELECTRONIC FLAME SAFEGUARD CON TROL EQUIPMENT: 52A-4322F burner is available with electronic flame safe guard control consisting of C7013A photocell installed in burner. Q270A safety switch base mounted on burner housing and RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly at $93 00 addition to Trade Price of 52A burner. For installations with firing rates above 4.00 gph requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Labora tories. Inc., oil burners are available with special electronic flame safeguard controls as follows: 62-2-7003 burner at $30.00 addition to Trade Price of model 62-2-7002. 96-7502 burner at $30 00 addition to Trade Price of model 96-7501. 97-7602, 98-7702 or 97A Hi-Lo 7651 burner at $13.50 addition to respective Trade Price of models 97-7601, 98-7701 or 97A Hi-Lo 7650. Two-stage fuel unit is available for DH oil burners at $5 00 Trade Price extra. Two-stage fuel unit is standard on 52A, 62, 96, 97, 98, and 97A Hi-Lo oil burners. Delayed oil valves are standard on all the above burners with electronic controls. V4001A oil valve is available installed on 52A and 62-1-7000 burners at $13 00 Trade Price extra. When ordering oil burners be sure to specify nozzle sizes wanted. One nozzle is furnished with DH, two nozzles with 52A, 62, and 96, and three nozzles with 97, 98 and 97A Hi-Lo oil burners. Nozzles and strainers are as follows: For DH: Hollow cone. 60*, 0 65-1 25 gph. Solid cone, 60*, 1 35-3.00 gph. For 52A, 62, 96, 97, 98, and 97A Hi-Lo: Solid cone. 70*, 1.50-2.00 gph. Solid cone, 80*, 2.25-6.50 gph. Vapor Installations: Substitute 450-BC-l vapor limit control for 450-BA-l pressure limit control with No. 11 or No. 12 con trol sets and add $10.99 to Trade Price. Electric Clock Thermostat: Substitute T852A for CB-520 ther mostat; specify on order control set number with suffix "B", and add $27 17 to Trade Price. Substitute CB-580 for CB-520 thermostat: Deduct $2 83 from Trade Price with control set shown above. If CB-703 intermittent ignition primary control is wanted, add $3 00 to Trade Price of oil burner regularly furnished with CB-704 control. Models DH-8, DH-15 and DH-23 conversion and replacement Oil burners are available with light-sensing constant ignition primary control consisting of factory mounted series 956 flame detector and CB-66815 relay (for jacket mounting only) shipped with burner at same Trade Prices as shown above with control set or with primary control set and nozzle only. Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters and comply with Commer cial Standard CS-75. Capacities of oil burners using No. 1 or No. 2 fueloil are for installations at sea level and at elevations up to 1.000 feet. Reduce by 4% for each additional 1.000 feet above sea level. For discount on repairs, see page Z. Page 31 HH3 01646 OIL BURNER CONTROL SETS CONTROLS American-cStandard HYDRONIC HEATING control tot for control number eontmti of control ut description add to Trad# Price of oil burner with basic eontml set NO. 11 Steam No. 12 Steam No. 13 Wttor No. 14 Water No. 15 Water No. 16 Wator No. 16-Z Water No- 19 Warm Air No. 20 Warm Air No. 26 Wator No. 34 Wator No. 36 Wator No. 36-Z Wator Boiler without domestic hot water. Boiler with year-round domestic hot water, built-in heater. Boiler without domestic hot water, im mersion control. Boiler without domestic hot water, surface mount control. Boiler with year-round domestic hot water, storage tank heater, using cir culator. Boiler with year-round domestic hot water, built-in tankless heater, using circulator. 2-Zone control, for boiler with yearround domestic hot water, built-in tankless heater, using circulators. Note: For each additional zone, add 1 CB-520 thermostat and 1 CB-262 relay transformer at current prices. Gravity furnace. Forced warm air unit. Boiler with year-round domestic hot water, built-in tankless heater, using circulator. Boiler without domestic hot water, constant circulator operation. Arcoleader and A-5 units ONLY with year-round domestic hot water, builtin tankless heater, using circulator. Arcoleader and A-5 units ONLY. (1 No. 36-Z set is required for each zone in addition to the first zone which is controlled by the No. 36 control set.) CB-520 450-6A-1 CB-520 450-BA-l CB-666 CB-520 CB-655 CB-520 LA409A CB-520 CB-6S5 CB-666 CB-262 CB-520 CB-655 CB-666-DT CB-262 2 CB-520 CB-655 CB-666 CB-666-R 2 CB-262 CB-520 CB-644 CB-520 CB-840-S CB-520 CB-655 CB-666-AD CB-262 CB-520 CB-851 CB-520 CB-610 CB-520 CB-260 thermostat limit control thermostat limit control 1mm. operating control thermostat limit control thermostat limit control thermostat limit control 1mm. operating control relay transformer thermostat limit control imm. control double throw switch relay transformer thermostats limit control 1mm. operating control rev. acting low limit control relay transformers thermostat limit control thermostat fan and limit control thermostat limit control imm. control double throw switch, ad], differential relay transformer thermostat circulator-limit imm. control thermostat imm. control relay combination thermostat zone control relay $10.15 $22.75 $24.40 $53.20 $ 1.35 $24.40 $ 5.90 $15.05 Add-on zone (Use only with No. 36 set) $20.35 Controls - Regularly furnished are for IIS volt 60 cycle current number description Trade Price CB-520 C8-S20100 C8 520102 AMERICAN-STANDARO thermostat. ROUND, low voltage wall plate for CB-520 wall plate for vertical wait box for CB-520 S 7.74 .45 .71 CB-S80 CB-44002 thermostat, low voltage thermostat, line voltage, heating only 4.91 X2.1I 450-8A-1 450-BC 1 pressure limit control. 0-10 lbs. vapor limit controL 0-3*,$ lbs. 11.59 22.58 CB-610 CB-260 CB-262 immersion control relay combination add-on zone control relay (use only with CB-610) relay transformer 23 48 12.60 12.60 CB-655 CB 655 SE CB-656 CB-656-OT immersion timit control imm. limit control (for millivolt circuit) imm. limit control imm. hot water control, double throw switch 8.44 8.44 8.44 10.13 CB 666 C8-666-R CB-666-DT CB-666 AO immersion operating control reverse acting low limit control 1mm. hot water control, double throw switch imm. hot water control, double throw switch. adjustable differential 10.13 10.13 11.81 11.81 number description CB-66815 CB-703 CB-704 CB-706 CB-840-S CB-844 CB-851 RS-116-F AMERICAN-STANDARD (continued) light-sensing primary control, constant primary control, intermittent Ignition primary control, constant ignition primary control, constant ignition fan and limit control warm air limit control circulator-limit immersion control immersion control relay combination Price $25.80 27.30 25.80 24.83 9.77 8.36 14.36 24.90 T80A GENERAL CONTROLS thermostat (for millivolt circuit) 521 T86A T832A T852A LA409A HONEYWELL thermostat, low voltage thermostat, low voltage, manual turn-down thermostat, electric clock surface mount water limit control 7.80 20.96 34 91 8.03 No. 369 McDonnell fc Miller low water cut-off for automati cally fired steam Arcoliner. Oakmont. Severn, Exbrook, A-S and A-7 boilers and/or boiler-burner units.......................... Trade Price each $16.75 number VD-203 HH-3 Pace 32 Vematherm water mixing valves description sirs adjustable V4* */i* Trade Price $11.48 12.06 01647 American-Standard HYDRONIC HEATING INSHOT GAS BURNERS INSHOT GAS CONVERSION BURNER -- Factory assembled controls regularly furnished are for IIS volt, 60 cycle current A.G.A. ratlngs-BUi Input par hour modal numbor IN-150 IN-245 IN-275 input* (min ) max (min |max (min (max Nit snd Mxd. Gii 80.000 150,000 130.000 245.000 130.000 275.000 Mfd. Gii 80,000) 150,000) not ) available) not ) available) Trado Price with standard equipment Nat and Mxd. Gat Mfd. Gat $68.00 $73.25 approx. shipping weight 20 $74.50 $83.75 not available not available 21 21 Gas viivc sixas: vh" for IN-150 Nat. and Mxd. Gas, Vi' for alt othar sizes. Sheet metal mounting plate required for all other conversions except Arcoleeder and Arcoliner Wet Base oil boilers. This plate to be furnished by installer. If CB-520 thermostat not desired, deduct $7.74 from Trade Price shown above. INSHOT GAS BURNER MAXIMUM INPUTS FOR ARCOIEADER AND ARCOLINER BOILERS Burner Model: Type of gas: IN-150 Nat. Mxd. Mfd. IN-245 Nat. Mxd. only IN-275 Nat. Mxd. only IN-275 Nat Mxd. only Boiler Model Arcoleader Arcoliner Maximum Gas Inputs -- Btu/hr. 3 lection 4 *get!on 115.000 120.000 160.000 170,000 5 section 210,000 200,000 6 lection 260,000 6-Section Arcoliner is not recommended for gee firing Standard equipment includes: CB-520 thermostat. Runner pilot ignition. Manual shut-off valve. Control housing. Stainless steel flame spreader. Pilot throttling valve. Pilot filter--with mfd. gas burners only. Two main burner orifices: one drilled for minimum input, factory installed; the second, also drilled for minimum input, is provided. Models IN-150 and IN-245 V-600 series combination gas valve, pressure regulator and safety pilot switch, transformer, manual opener. Model IN-275 General Controls KX3H quiet solenoid gas valve, plug-in safety pilot switch, transformer, manual opener. Gas pressure regulator. Optional equipment: Self-energizing control.i General Controls T80A thermostat, B-60 gas valve and PG9 pilot generator-if desired, specify on order: Burner Model IN-150 IN-150 IN-245 IN-275 Nat and Mxd. Mfd. Nat. and Mxd. Nat. and Mxd. Trade Charge No extra cost Add $2.75 Add 2.75 No extra cost Salad from list below special limit control which mutt bo usad with salf-energlzing controls. 100% safety shut-off, all models, specify on order and add $2.00 to Trade Price above. Pilot filter-regularly furnished only for Mfd. gas. If desired for Nat. and Mxd. gas, specify on order and add $1.50 to Trade Price above. Optional controls for self-energizing (millivolt) application: Number L-52A30A1A L-39PA412 S45A1A3A3 S45A5AM3 Description General Controls immersion limit control ............... General Controls pressure boiler limit control, scale 0-10 lbs..................................................................... General Controls warm air limit control................. General Controls fan and limit control.................... For other optional control., *ee page 32. Trade Price $10.05 11.44 3.30 6.71 Orders must specify: GAS CONVERSION BURNERS-lnstructions for Ordering 1- Type of gas. 2. Btu (heat value of gas) and specific gravity. For discount on repairs, see pope 2. 3. Pressure available at outlet of gas meter. 4. Optional controls, if desired. Page 33 HH-3 01648 STOKER FIREl> BOILERS ITIAJN ANO WAT American-Standard HYDRONIC HEATING SEVERN STOKER FIRED BOILERS Flush Jacket STEAM j WATER output Mbh flrtitg pounds porheur not taotaffod rating q steam Mbh *0 ft water Not adcptetf. re:- ^ .it-in Water Heater (see options below) SC-17 SC-21 SC-25 SC-29 SC-33 SC-37 WC-17 WC-21 WC-25 WC-29 WC-33 WC-37 146 16 456 109.5 168 18 525 126.0 188 21 588 141.0 730 840 940 216 24 675 162.0 1080 247 27 772 185.3 1235 278 31 869 208.6 1390 .. . Pries 1 annmf 1 shipping WSigtlt $355.00 395.00 434.00 477.00 539.00 597.00 1053 1220 1301 1457 1534 1687 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water: Theraltimeter and ASME relief valve. Optional equipment: Boilers arranged for but less Built-in heaters: If desired, for use with heaters No 590. 594 and 595. add suffix letter "T" to boiler number and add W OO to Trade Price of boiler with standard equipment If 254" right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of boiler. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam Severn boilers, see page 32. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. Below are the ratings and Trade Prices for Built-in heaters available for Severn stoker boilers. For detailed information on ratings, see page 2. Hsatar No. 703 594 595 590 Heater Typo tank tank tank tankless Heater Ratings gals, capacity 66 100 160 3y2 per minute Trad# Pries $ 9.00 48.00 42.50 36.00 approx. shipping woight 7 54 51 60 EXBROOK STOKER FIRED BOILERS STEAM WATER gross output Mbh l=B=R capacity ibs/hr IMtlsS=R rating sqft steam Mbh not rating q ft water Trad* Pries approx. six* shipping woight Not adapted for Built-in Water Heater (see options below) SC-207 SC-208 SC-209 SC-2010 SC-2011 SC-2012 SC-2013 WC-207 WC-208 WC-209 WC-2010 WC-2011 WC-2012 WC-2013 276 30 863 207.1 335 37 1047 251.3 396 43 1238 297.1 452 50 1413 339.1 508 56 1588 381.1 564 62 1763 423.1 620 68 1938 465.1 1380 1675 1980 2261 2541 2821 3101 $604.00 681.00 758.00 835.00 912.00 989.00 1066.00 8x12x25 8x12x25 !2x12x30 12x12x30 12x1.7x35 12x15x40 12x16x40 2150 2313 2628 2821 3134 3309 3641 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve. Optional equipment: Boilers arranged for but less Built-In heater If desired add suffix letter "T" to boiler and add W-00 to Trade Price of boiler with standard equipment. Built-in water heaters are available for use with Exbrook "T" type boilers only. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $425. For low water cut-off for Exbrook steam boilers, see page 32. Below are the ratings and Trade Prices for Built-in heaters available for Exbrook "T" type Stoker boilers. For detailed information on ratings, see page 2. Hoator No. 591 592 For complete information on boiler ratings, see page 2. Hoator Type Hoator Ratings gals, capacity Trado Pries tank 120 $32.50 tank 200 46.50 For discount on repairs, see page 2. approx. shipping woight 35 53 HH-3 Pace 34 01649 boiler numsr STEAM WATER 3 SC 8 3 SC 9 3WC-8 3 WC 9 AMERiCAN-<Standard HYDRONIC HEATING STOKER FIRED BOILERS STtAM AND WATIt output Mbh 706 798 NO. 3 REDFLASH STOKER FIRED BOILERS Jacketed and unjacketed firing rato pounds par hour 78 88 not Installed rating sq ft atoam Mbh sq ft water 2207 2494 529.6 598.6 3531 3991 un|ackated Trade Price approi. shipping weight $1130.00 1255.00 3652 4041 jacketed Trade Price approx. shipping weight $1222.00 1351.00 3827 4224 Standard equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve. Optional equipment: External water heater tappings available at following added charges: Jacket-$2.00 per tapping. Sections-$2.00 per tapping. A-7 STOKER FIRED BOILERS Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure. boiler number STEAM WATER gross IsBsR output Mbh l=B=R burner capacity Ibs/hr net 1 = IsR rating sq ft steam Mbh net reting sq ft water A-705SC A-706SC A-707SC A-705-WC A 706-WC A-707-WC 866 1012 1196 A-708-SC A-709SC A-710-SC A-708WC A-709WC A-710WC 1376 1570 1760 A-711SC A-711-WC 1956 A-712SC A-712WC 2148 A-713-SC A-713WC 2340 A-714SC A-714-WC 2532 95 2707 111 3163 131 3738 151 4340 172 5013 194 5672 215 6328 236 6949 257 7570 278 8191 649.7 759.2 897.2 4331 5061 5981 1041.6 1203.1 1361.2 6944 8020 9075 1518.6 10125 1667.7 11118 1816.8 12112 1965.8 13105 chimney size Trade Price C n eted approx. shipping weight lacket id Trade Price approx. shipping weight 16 x 16 * 28 16 x 16x30 16 x 20 x 36 $1260.00 1380.00 1555.00 3882 4518 5149 $1341.00 1473.00 1660.00 4054 4693 5332 16 x 20 x 42 16 x 20 x 45 20 x 20 x 50 1725.00 1877.00 2055.00 5720 6330 6990 1842.00 2006.00 2196.00 5929 6545 7209 20 x 20 x 55 2227.00 7556 2380.00 7817 20 x 20 x 60 2397.00 8208 2562.00 8506 20 x 24 x 70 2567.00 8912 2744.00 9182 20 x 24 x 80 2739.00 9616 2928.00 9886 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water Theraltimeter and ASME relief valve for 50 lbs. Optional equipment: Steel pedestal bases for installation under the regularly fur nished 12" base for greater base heights, will be furnished when specified on order at the following added charges: section size 5 thru 7 8 thru 14 base heights 8" 10" added charge $46.00 76.00 For low water cut-off for A-7 steam boilers, see page 32. For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Page 35 HH-3 01650 HAND FIRED BOILERS ITIAM AMO WATtP STEAM hollar number WATER S-153D S154-D S-155-D W153-D W154-D W-155-D American-Standard hHronic heating ARCOLINER HAND FIRED BOILERS Factory assembled sections. uiy UOOC uuualrucuuu. Flush jacket. ' grots output Mbh tqft attain not Irntailed rating Mbh tq ft watar Trada Pnca approx. hipping waight 102 180 43.2 288 $300.00 771 152 272 65.3 435 351.00 928 204 373 89.4 596 403.00 1083 Standard Equipment: Steam: Steam gauge. ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Built-in Heaters: If Front Section arranged for but less Built-in screw-in heaters No. 701 or 702 is desired specify on order. Below are the ratings and Trade Prices of Built-in heaters available for Arcoliner.Dry Base steam boilers. For detailed information of ratings, see page 2. Haator No. Type gala, capacity Trada Prlca approx. waight 701 tank 60 $8.50 5 702 tank 40 8.00 4 Note: Built-in water heaters are not recommended for hand fired water boilers. SEVERN HAND FIRED BOILERS Flush jacket. hollar numbar STEAM WATER S-17 S-21 S-25 S-29 S-33 S-37 W-17 W-21 W-25 W-29 W-33 W-37 groat output Mbh aqft ataam not irtstallad rating Mbh *9 watar Trada Prfca approx. shipping waight 194 353 84.7 565 $393.00 1243 244 453 108.7 725 454.00 1413 296 553 132.7 885 519.00 1521 328 630 151.3 1009 364 710 170.5 1137 396 783 187.9 1253 571.00 629.00 678.00 1686 1783 1956 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Built-in Heaters: If 214" right or left side tapping in back section for Built-in screw-in heaters No. 701, 702 or 703 is desired specify on order and add $2.00 per tapping to Trade Price of boiler. Below are the ratings and Trade Prices of Built-in heaters available for Severn hand fired steam boilers. For detailed information on ratings, see page 2. Haatar No. Haatar Typo Haatar ratings gala, capacity Trada Plica approx. shipping waight 701 tank 60 $8.50 702 tank 40 800 703 tank 100 9.00 Note Built-in water heaters are not recommended for hand fired water boilers. 5 4 7 For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. HH-3 Page 3S 01651 STEAM 2 S-6 2 S-7 2-S-8 2-S-9 2-S-10 2-S-ll 2-S-12 Mlr number WATER 2-W-6 2-W-7 2-W-8 2-W-9 2-W-10 2-W-ll 2-W-12 American -.Standard HY PRO NIC HEATING HAND FIRED BOILERS STIAM ANI WAT!* NO. 2 REDFLASK HAND FIRED BOILERS Jacketed and unjacketed. .. p greet output Mbh K net installed rating few - steam * Mbh a ft water unjacketed Trade Price apprex. hipping weight 390 769 184.7 1231 % 626.00 1966 464 940 225.7 1505 704.00 2293 536 1111 266.7 1778 606 1281 307.5 2050 782.00 860.00 2466 2782 676 1453 348.8 2325 938.00 2999 744 1623 389.5 2597 1016.00 3313 812 1794 430.5 2870 1094.00 3503 U Jacketed approx. hipping weight $ 690.00 772.00 854.00 936.00 1018.00 1100.00 1182.00 2091 2390 2572 2897 3122 3446 3644 Standard Equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. STEAM 3 S-6 3-S-7 3-S-8 3-S-9 boiler number WATER 3-W-6 3-W-7 3-W-8 3-W-9 NO. 3 REDFLASH HAND FIRED BOILERS Jacketed and unjacketed. greet output Mbh 696 814 932 1046 net installed rating sq ft steam Mbh sqft water 1503 1799 2100 2400 360.6 431.8 504.1 576.0 2404 2879 3360 3840 unjacketed Trade Price approx. shipping weight $ 958.00 1102.00 1246.00 1390.00 3243 3698 4110 4549 jacketed Trade Price approx. shipping weight $1042.00 1190.00 1338.00 1486.00 3397 3870 4285 4732 Standard Equipment: Steam: Steam gauge. ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Note: Buckwheat coal grate bars will be furnished at no additional charge when specified on order. a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2. Pag* 37 01652 HAND FIRED BOILERS ITLUt AMO WATtt Am e ricAn -<St andafd HVDRONIC HEATH' A-7 HAND FIRED BOII *3S Jacketed and unjacketed. Tested and equipped lor 50 lb3. sr >. o ; lug pressure. bollar number STEAM WATER groaa IsBsR output Mbh not l=B=R tqft to am Mbh A-705-S A-705-W A-706-S A-706-W A-707-S A-707-W A-708-S A-708-W A-709-S A-709-W A-710-S A-710-W A-711-S A-711-W A-712S A-712-W 1122 1298 1510 1708 1910 2108 2288 2456 2606 3101 3725 4342 5008 5681 6326 6947 625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3 not rating aq ft wator chlmnoy aiza unjadoatad Trada Prtca approx. hipping weight Fackatad Trada Prtca approx. hipping weight 4169 16x16x40 4962 16 x 20 x 45 5960 20 x 20 x 50 6947 20 x 20 x 55 8013 20 x 20 x 60 9090 20 x 24 x 65 10122 20 x 24 x 70 11115 24 x 24 x 75 $1393.00 4294 $1474.00 4466 1519.00 5006 1612.00 5181 1696.00 5738 1801.00 5921 1877.00 6392 1994.00 6601 2006.00 7199 2135.00 7334 2164.00 7858 2305.00 8077 2336.00 8506 2489.00 8767 2496.00 9231 2661.00 9529 Standard equipment: Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools. Water Theraltimeter and ASMS relief valve for 50 lbs., automatic damper regulator and firing tools. a For complete information on boiler ratings, see page 2. For discount on repairt, see page 2. HH*3 Page 38 01653 American-Standard HYDRONIC HEATING RADIATORS RADIATOR ACCESSORIES width height. Inch#* q ft per section Trade Price per sq ft 6 tube 3 tube 4. 5, 6 tube 4, 5 tube 4, 6 tube 32 3.7 $1.25 25 1.6 1.25 25 2.0, 2.4. 3.0 1.18 22 1.8. 2.1 1.23 19 1.6, 2.3 1.25 Arco Radiators are regularly furnished with two and one-half inch <2t4") legs but can be supplied on Special Order with four and one-half inch (4ti") legs, or without legs, at no extra charge. Arco Radiators sold only in even number of sections up to a maximum of 56 sections. SUNRAD RADIATORS yp sq ft per section Trade Price per aq ft M 5x20 M 7`/2 x 23 2.25 3.40 $1.49 1.56 Important: Increase size 5% for recessed installation-- air space top and sides. Vi* at back. Increase size 15% for tightly recessed in- stillation-- no clearance top or sides. Vi" air space at back. Sunrad Radiators are regularly furnished with two and threequarter inch (2 V) legs but can be supplied on special order without legs, at no extra charge. Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections. PEERLESS WALL RADIATORS *yp sq ft per section Trade Price per sq ft 11-B Pattern 8-B Pattern ii 8 $1.34 1.41 Extra charge of $0.60 each will be made tor tappings at Nos. 20. SO. 60 and 90 as shown on outline drawings of Peerless Wall and Ceiling Radiators in current literature. Radiators furnished per Figures 840 or 1140 add 52.52 trade extra Radiators furnished per Figures 842 or 1142 add $5.04 trade extra For convenience in handling and shipping. Nos. 8-B and 11-B Radiators will be assembled in lengths not exceeding 4 sections. RADIATOR Arco Brackets: Trade Price *>ch For 3. 4, 5. 6 tube, with Wall Plate............................ $0.83 Arco Radiator Pedestals: Vi' and 1'................................................................ 0.32 Wz" .......................................................................... 0.41 Sunrad Brackets: For M5 x 20 and M7>/2 x 23.................................. 0.65 Peerless Wall and Ceiling Brackets: Adjustable, with Bearing Plate, single spool........... 4.04 Adjustable, with Bearing Plate,double spool........... 7.34 Type L ...................................................................... 0.23 Type M ...................................................................... 0.16 Type MM .................................................................. 0.23 TypeP ...................................................................... 0.49 ACCESSORIES Nipples, Plugs, Bushings, etc.: Trade Price *ach 1", lVi', l'/2" Plugs. Bushings....................... $0.23 3/4". 1", li/," Slip Nipples........................................ 0.23 1 Vi" Hexagon Nipples.............................................. 0.41 Vi' Air Vent Plugs..................................................... 0.01 Radiator Rod Nuts.................................................... 0 01 Radiator Rods.......................................... per section 0.01 Above items available for use only with our Radiator products. Sunrad Grilles Inlet--Stamped Lattice Type....................... per section $0.19 Page 39 HH-3 01654 BASEBOARD PANELS AMERiCAN-^tandard HYDRO NIC HEATIKC RADIANTRIM BASEBOARD PANELS MEMBER New Model B Steam Rating per lineal foot 2.75 sq ft SEE CURRENT LITERATURE FOR APPROVED l = B=R STEAM AND HOT WATER RATINGS per lineal foot Trad* Price-- $3.M $1.12 New Model 8 Radiantnm Panel lengths (24 ft to 30 ft) are made up from the following sections: 1 4 ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 2 ft Double end section New Model 8 Accessories phea Extension Panel and Brackets (Two 6 ft lengths per box) .............................$8.40 Extension Panel Retaining Bracket........................ 0.22 Extension Panel Cover Strip.................................. 0.53 Assembly Clamp . 7.70 Compression Corner Connection ........................... 2.40 Retaining Block...................................................... 0.15 Adjustable Leg ....................................................... 0.20 Tie Bolt ....... .................................................... 0.06 Theta items are regularly furnished as required with New Model 8 Radiantnm Panels and Accessories. Prices are shown for repair or re placement purposes. Packed in quantity of 10 per box price (Available only in this minimum quantity) per bos of 10 Inverted Corner Cover.............................................. $10.50 Extended Inverted Corner Cover.............................. 17.50 Projecting Corner Cover ........................................ 14.20 Valve Enclosure (all R H. or L.H.) ........................... 12.35 End Box (all R.H. or L.H.) ....................................... 7.00 per lineal foot Trad* Price-- $3.81 per tquare foot $1.12 Model 10 Radiantnm Panel lengths (2*4 ft to 30 ft) are made up from the following sections: 14 ft Left hand end section 1 ft Right hand end section 2 ft Left hand end section 2 ft Right hand end section 2 ft Center section Assembly length with legs and tappings at each end: 14 ft Double end section 2 ft Double end section Model 10 Accessories T r*de Price Extension Panel and Brackets (Two 6 ft lengths per box) .................................. $13.10 Extension Panel Retaining Bracket ...................... 0.22 Extension Panel Cover Strip................................. 0 53 Assembly Clamp...................................................... 7.70 Compression Corner Connection......................... 2.40 Retaining Block...................................................... 0.15 Adjustable Leg....................................................... 0 20 Tie Bolt .................................................................... 0.06 These items are regularly furnished as required with Model 10 Raqtantnm Panels and Accessories. Prices are shown for repair qr re placement purposes. Packed in quantity of 10 per box (Available only in this minimum quantity) per box of 10 Inverted Corner Cover.............................................. $13.10 Extended Inverted Corner Cover............................. 23.60 Projecting Corner Cover.......................................... 16.60 Valve Enclosure (all R.H. or L.H.) ........................... 18.35 End Box (all R.H. or L.H.) ....................................... 9.80 Sag No. 0 1 2 EXTRA RADIANTRIM ACCESSORY BAGS For Tratfo Prico Bag No. For Double Leg Section 2>y-6' Panel Length 64 *12' Panel Length t .65 .80 1.80 3 12V4'-18' Panel Length 4 18Vi'-24' Panel Length 5 24V4'-30' Panel Length Sufficient quantities oT these bags are regularly, furnished with Radiantnm Panels Prices shown are for extra bags as may be required. Trade Pnee $2 65 3 50 4 50 SHIPPING WEIGHTS For estimating purposes only, the following approximate weights per square foot may be used for radiators: Arco. 44 pounds: Sunrad. M5 x 20-6 pounds. M74 x 23-64 pounds; Peerless Wall. 64 pounds; New Model B Radiantnm Panels* 4*4 pounds per souare foot. 12 16 pounds per lineal foot; Model 10 Radiantnm Panels: 4V pounds per square foot. 16.15 pounds per lineal foot. For estimating purposes only, the following approximate shipping weights may be used for Convectors and Cabinets: Arco Convectors-elements only-see page 41. Complete Cabinets, for Arco or Multifin Convectors, per sq ft of cabinet output-14 pounds. Multifin Convectors-elements only-see page 44. Multifin Units (convectors shipped mounted in cabinets) per sq ft of cabinet output- "Special Service Line" Types F. R. RC--14 pounds. Type W-14 pounds. .Type FS -14 pounds. Type S-14 pounds. "Stock Moder-1.13 pounds; also see pages 45 and 46. Heatrim Panels see pages 42 and 43. MH 3 Page 40 01655 American-Standard HYDRONIC HEATING COMVrCTORS ARCO CONVECTORS SPECIAL SERVICE LINE when sold in combination with standard cabinets COMBINATION PRICE: The actual output in square feet of catalog rating-Steam (215F> obtained with the cabinet heights furnished deter mines the price of convectors and cabinets sold in combination. The total price of each order equals the irr.c.ir-. jf catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multipled by the total nurr.cer of units ordered cabinet type description Trad* Price per eq ft unit extra charge F Floor Type-free standing .... $1.35 $17.10 FG Floor Type-free standinginlet grille........................... 1.39 W Wall Hung-flat top............... 1.35 17.10 17.10 FS Free Standing-sloping top ... 1.42 17.95 FSG Free Standing-sloping topmlet grille........................... 1.45 17.95 S Wall Hung-sloping top........ 1.35 17.10 R Recessed-ti" flanged edges 1.34 18.15 RG Recessed-4' flanged edgesinlet grille ....................... 1.38 18.15 Standard Cabinets are furnished in: Prime painted sheet steel--reinforced, No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline For illustrations of cabinets, see page 44. For cabinet extras, see page 47. cabinet type description Trade Price per sq ft unit extra charge RGB Recessed-^" flanged edgesinlet grille with bottom overlap .............................. $1.38 $21.30 RC Semi-recessed--24" or 44" flanged edges...................... 1.34 19 75 RCG Semi-recessed-24" or 44" flanged edges-inlet grille 1.38 19.75 RCGB Semi-recessed-24" flanged edges-inlet gnlle-with bottom overlap.................. 1.38 22.90 RCGB Semi-recessed-44" flanged edges-inlet gnlle-with bottom overlap.................. 1.38 22 90 front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate convectors listed in current literature ARCO CONVECTOR -- steam or wafer ELEMENTS ONLY (when sold less cabinets) convector length inches No. 4 31/," depth approx. unit shipping Trade no. weight Price No. 6 5s/a" depth unit no. approx. shipping weight Trade Price No. 8 7%" depth approx. unit shipping Trade no. weight Price No. 10 9`/2" depth approx. unit shipping Trade no. weight Price 18 418 39 $12.41 618 57 $18.28 818 71 523.02 1018 84 $27 76 23 423 50 16.02 623 73 23.57 823 92 29.79 1023 110 35 88 28 428 61 19.62 628 90 28.90 828 113 36.57 1028 136 44 11 33 433 72 23.25 633 106 34.30 833 134 43.33 1033 162 52 23 38 438 83 26.86 638 123 39.62 838 155 49.99 1038 188 60 47 43 443 94 30.36 643 139 44 92 843 176 56 75 1043 213 68 60 48 448 105 33.95 648 146 50.22 848 197 63.53 1048 238 76 83 53 453 107 37.57 653 172 55.51 853 218 70.30 1053 264 85 06 58 458 128 41.19 658 189 60.82 858 239 77.07 1058 289 93 20 63 463 139 44.79 663 206 66.22 863 260 83.82 1063 314 101 30 Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets. For sizes not listed above-price on application. Page 41 MH 3 01656 HEATRIM PANELS AMERiCAN-tStandard HYDRONIC HE ATI NO SEE CURRENT LITERATURE FOR APPROVED I-B-R HOT WATER RATINGS description hipappinpgrowxe. ight COMPLETE UNITS: Model N85-L-Packaged in 3', 4', S', S', and 8' lengths--completely assembled (package contains element, one-piece back and top section, front panel, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. ( per 3 ft. length 1 per 4 ft. length r per 5 ft. length 1 per 6 ft. length 1 per 8 ft. length per lineal foot 8 10 13 16 22 2% Model N85HH-Packaged in 3'. 4', S'. 6', and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. ( per 3 ft. length } per 4 ft. length / per 5 ft. length per 6 ft. length ( per 8 ft. length per lineal foot 10 13 16 20 26 3% HEATING ELEMENTS: Model N50 (H' tube)-Packaged six equal lengths per box. Model N85 (V," tube)-Packaged six equal lengths per box. Model N85 (" tube)-Individually packaged one per box. ( per box of six 3' lengths ] per box of six 4' lengths / per box of six 5' lengths 1 per box of six 6' lengths | per box of six S' lengths per lineal foot per box of six 3' lengths per box of six 4' lengths per box of six 5' lengths per box of six S' lengths per box of six 8' lengths per lineal foot per box of one 3' length per box of one 4' length per box of one S' length per box of one 6' length per box of one 8* length per lineal foot Model N110 (1' tube)-Packaged six equal lengths per box. per box of six 3' lengths per box of six 4' lengths per box of six 5' lengths * per box of six 6' lengths per box of six 8" lengths per lineal foot For comparative and estimating purposes only, HM-3 Page 42 10 13 17 22 28 % 10 13 17 22 28 % 2 3 3 4 5 % 13% 18 22% 27 36 V* Trad* Me* $ S.85 7.80 9.75 11.70 15.60 1.95 7.35 9.80 12.25 14.70 19.60 2.45 16.20 21.60 27.00 32.40 43.20 .90 18.00 24.00 30.00 36.00 48.00 1.00 3.21 4.28 5.35 6.42 8.56 1.07 21.60 28.80 36.00 43.20 57.60 1.20 01657 A*iERiCAN-iStand&rd jH Y D R ON I C< HE AT IN Q HEATRIM BASEBOARD PANEL ACCESSORIES VHCA n^UPPC Model L-Multiple picketed in 3'. 4'. S', S', and 8' lengthsthree equal length! per box (package contain* 3 one-piece back and top section*, 3 front panel*, loose snap-in support bracket*, element slide cradles and 3 seta Joining pieces). Fin ished with white prune coat of paint. Model L-Individually packaged in 3', 4', S', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion. front panel, loose snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint Model HH-Multiple packaged in 3`. 4', 5', 6', and 8' lengths-- three equal lengths per box (package contains 3 one-piece back and top sections. 3 front panels, 3 splitter/dampers, loose snap-in support brackets, element slide cradles and 3 sets joining pieces). Finished with white prime coat of paint. Model HH-Individually packaged in 3', 4', S', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion. front panel, splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint. For comparative and estimating purposes only. per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8* lengths per lineal foot per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 8 ft. length per lineal foot per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8' lengths per lineal foot per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 8 ft. length per lineal toot Description MODEL L ENCLOSURE ACCESSORIES: Inverted Corner Cover--one-piece frontand top section......................packed per box of 10 Inverted Comer Cover-back section only........................................... packed per box of 10 Projecting Comer Cover....................................................................... packed per box of 10 Valve Enclosure-8" wide....................... packed all right hand or all left hand per box of 10 End Cover--4" wide................................. packed all right hand or alt left hand per box of 10 End Cap-114' wide................................. packed all right hand or all left hand per box of 10 Wall End Piece-3 r wide..................................................................... packed per box of 10 One-Foot Filler Pieces-14" wide..........................................................packed per box of 5 Joining Pieces-2" wide.................................................................. packed per box of 20 sets Note: Finished with white prime coat of paint. Dampers for Model L Enclosures: Packaged in twelve equal lengths per box. Not*: Finished with white prime coat of paint. per box of 3 ft. lengths per box of 4 ft. lengths per box of 5 ft. lengths per box of 6 ft. lengths . per box of 8 ft. lengths per lineal foot Replacement parts for Model L enclosures: Enclosure fronts--8 ft. lengths only.......... Snap-in support bracket with slide cradle. each each MODEL HH ENCLOSURE ACCESSORIES: Inverted Comer Cover-one-piece frontand top section........................... packed per box of10 Inverted Comer Cover-back section only................................................. packed per box of10 Projecting Comer Cover............................................................................. packed per box of10 Valve Enclosure-8' wide....................... packed all right hand or all left hand per box of 10 End Cover-4* wide................................packed all right hand or all left hand per box of 10 End Cap-114' wide................................packed all right hand or all left hand per box of 10 Wall End Piece-3 V" wide........................................................................... packed per box of10 One-Foot Filler Pieces-14" wide............................................................... packed per box of5 Joining Pieces-2" wide.................................................................. packed per box of 20 sets Note: Finished with white prime coat of paint. Replacement parts for Model HH Enclosures: Enclosure fronts-8 ft. lengths only..........................................................................................each Snap-in support bracket with slide cradle.............................................................................each For comparative and estimating purposes only. NOTE: Add 25% to accessory unit price when ordered in less than quantities indicated above. Pif* <3 HEATRIM PANEL ACCESSORIES pom. hipping wight 19 24 30 35 47 6 8 11 13 16 24 30 38 46 59 2% 8 11 14 16 21 2 Vi approx. shipping weight 3 4 6 12 10 5 4 9 5 Trttfp Prtc* $ 7.20 9.60 12.00 14.40 19.20 .80 2.70 3.60 4.50 5.40 7.20 .90 12.06 16.08 20.10 24.12 32.16 1.34 4.35 5.80 7.25 8.70 11.60 1.45 Trade Price $ 8.00 4.50 10.00 17.50 12.50 5.00 3.00 6.00 5.00 12 3.60 17 4.80 22 6.00 25 7.20 34 9.60 Vi .10 2.00 .35 4 8.00 6 4.50 7 11.50 16 18.00 12 12.50 6 8.00 6 4.00 12 7.75 6 7.00 2.40 .35 HH-3 01658 CONVECTORS Typ. K (Slock Model) Typo F (Special Service) qBBBBD i Type KC (Stock ModeO Types TypeFS TypeW Type R npntmimniB TypeRC HH-] American-^Standard HYORONIC HEATING MULTIFIN CONVECTORS w*avK1i.ufi..iiuii_v,ii nr.r.itw. .vi The actual output in square feet of catalog ratmg-Steam (215'F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered. cabinst *yp description Trad* Pries per SO ft unit extra charts Stock Model K Floor Type-free standing........................................................ KC Semi-recessed-2Vi" flanged edges......................................... $0.40 .40 $11.00 14.00 Note: For expanded prices, see papes 45 and 46. For cabinet extras, see page 47. special service f FG w FS FSG R RG RGB RC RCG RCGB RCG8 Floor Type--tree standing-inlet grille................................ Free Standing-sloping top-inlet grille............................... Recessed-Vi" flanged edges-inlet grille............................. Recessed-Vi" flanged edges--inlet grille with bottom overlap..................................................................................... Semi-recessed-2Vi" or 4 Vi" flanged edges......................... Semi-recessed-2Vj" or 4Vi" flanged edges inlet grille....... Semi-recessed-2Vi" flanged edges-inlet grille-with botJ tom overlap.......................................................................... Semi-recessed--4Vi" flanged edges-inlet grille-with bot- tom overlap.......................................................................... $ 41 .44 .40 43 .46 .37 .47 .50 .50 .47 .50 .50 .50 $12 00 ' 12.00 12 25 13 75 13.75 12 25 13.75 13.75 16.75 14.75 14.75 17.75 17.75 Note: For cabinet extras, see page 47. Elements only (when sold less cabinets) -- steam or water csnvsctsr HttSSt 20 24 28 32 36 40 44 48 56 64 No. 4 -37/," depth alt as. 420 424 428 432 436 440 444 448 456 464 tpprsx. ttlippfRf TrsSt wslfflt Pries 8 $ 8.40 20 9.10 12 9.80 14 10.40 16 11.15 18 11.85 20 12.40 22 13.10 26 14.50 30 15.90 No. 6 -57/r depth Bit SS. 620 624 628 632 636 640 644 648 656 664 ppm. shipp isf Trais wsifltt Pries 13 110.75 16 11.65 19 12.60 22 13.45 25 14.30 28 15.25 31 16.10 34 16.95 40 18.75 46 20.50 No. i-7y," depth approi. sslt ibippiftf as. WSlftlt 820 15 824 19 828 23 632 27 836 31 840 35 844 39 848 43 856 51 864 59 Trias Fries $13.90 15.10 16.35 17.60 18.80 20.05 21.30 22.55 25.00 27.50 No. 10-9'/," depth ppm. nit tSippiRf Trada as. wiifllt Prtca 1020 21 $19.30 1024 26 20.55 1028 1032 1036 31 36 41 21.85 23.10 24.40 1040 1044 1048 46 51 56 25.60 26.90 28.20 1056 1064 66 76 30.70 33.25 Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee. Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back (K and KC-No. 26 gauge), ends and top rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate con vectors listed in current literature. ONE-PIPE STEAM: Particular reference must be made on order if special service convectors are to be used on onepipe steam systems. Multifin convectors-for two-pipe steam or water systems--cannot be used, or modified, for one-pipe systems. Elements arranged with special one-pipe steam headers--$.06 Trade Price per square foot of cabinet output extra. Page 44 01659 American-Standard HYDRONIC HEATING CONVECTORS MULTIFIN CONVECTORS n/AP TTrE a# K -iiwv#f1/t ftft mwvu - nut gm mniavim4 t*ii Expanded prices For use on two-pipe steam and hot water systems only. (ikitMt iMftk hthn No. 4 depth (4Vi" cabinet) Mil M. n MfRVt HW. WpptH ftiflrt Tnd* 20' cabinet height No. 6 depth (6Vi'cabinet; No. 8 depth (8Vi " cabinet) No. 10 depth (10Vi' cabinet) Mil M. n ft WfMflttppiM MtVt Vftlfllt Trv4* frill Mil ft. n ft *<npi Mm. shippiaf Vtlfllf TnH Rri nil M. H ft tkipp'M viifkl Trde fnii 20'/, 420-20 11.3 18 $15.52 620-20 16.3 21 $17.52 24 Vi 28 Vi 424--20 13.9 20 16.56 .... 624-20 20.1 629-20 23.8 24 27 19.04 20.52 32 Vi 632-20 27.6 29 22.04 832-20 33.6 33 $24.44 36*4 639-20 31.3 33 23.52 836-20 38.1 37 26.24 1036-20 42.4 42 $27.96 40 % 640-20 35.1 34 25-04 840-20 42.7 39 28.08 1040-20 47 6 48 30.04 44*4 644-20 38.8 37 26.52 48*4 56*4 64*4 648-20 656-20 664-20 42.6 50.1 57.6 40 45 52 28.04 848-20 31.04 856-20 34.04 864-20 51.8 60.9 70.0 46 51 59 31.72 1048-20 35.36 1056-20 39.00 1064-20 57 8 68 0 70.2 52 58 64 34.12 38.20 42.28 24' cabinet height 20*/, 24 Vi 28*/, 32Vi 36*4 40*4 44*4 48*4 56*4 64*4 420-24 424-24 428-24 13.1 16.1 19.1 20 22 25 16.24 17.44 18.64 620-24 18.4 624-24 22.7 628-24 26.9 632-24 31.1 636-24 35.4 640-24 39.6 644-24 43.8 648-24 48.1 656-24 56.5 664-24 65.0 23 26 30 33 35 38 42 44 50 57 18.36 20.08 21.76 23.44 832-24 25.16 836-24 26.84 840-24 28.52 30.24 848-24 33.60 856-24 37.00 864-24 37.9 43.0 48.2 58.4 68.7 78.9 38 40 44 50 55 63 26.16 28.20 1036-24 30.28 1040-24 48.6 54 4 45 52 34.36 1048-24 38.48 1056-24 42.56 1064-24 66.1 77.8 89 5 62 64 71 30 44 32.76 37.44 42.12 46.80 32" cabinet height 20% 34 Vi 28 Vi 32'/, 3V4 40 Vi 44 Vi 48 Vi 36 Vi 64 Vi 620-32 19.7 624-32 24.2 628-32 28.7 632-32 33.3 636-32 37.8 640-32 42.3 644-32 46.8 648-32 51.3 656-32 60.4 664-32 69.4 29 32 36 40 43 48 56 58 67 71 18.86 20.66 22.48 24.32 832-32 26.12 836-32 27.92 840-32 29.72 31.52 848-32 35.16 856-32 38.76 664-32 41.2 46.8 52.3 63.5 74.6 85.8 45 46 56 65 73 76 27.48 29.72 1036-32 31.92 1040-32 53.1 59.5 54 59 36.40 1048-32 40.64 1056-32 45.32 1064-32 72.3 85.1 97.9 69 76 84 32.24 34 80 39.92 45.04 50.16 Plugs and bushings are not regularly furnished with Multifln Convectors, but are available for separate sale at prices shown on page 39. Special air vent assemblies, Trade Price.................each $1.80 Metal trim strips, Trade Price................................... eac^ *2-75 Damper, chain type-standard length. Trade Price, each 2.10 Snap-On inlet grille. Trade Price..................................... 2 Page 45 HH-3 01660 CONVECTORS American-Standard HYDRONIC HEATING rnnwiw" cabinot tinitti inch** 20 Vi 24 Vi 28Vi 32 Vi 36 Vi 40 Vi 44 Vi 48 Vi 56 Vi 64 Vi MULTIFIN CONVECTORS TYPE KC - STOCK MODEL - PARTIALLY RECESSED Expanded prices For use on two-pipe steam and hot water systems only. No. 6 depth (6V4" cabinet) with 2Vi" flange unit no. sqft output approx. shipping walght CABINET HEIGHT *O CM 620-20 624-20 628-20 632-20 636-20 640-20 644-20 648-20 656-20 664-20 16.3 20.1 23.8 27.6 31.3 35.1 38.8 42.6 50.1 57.6 26 28 30 33 35 39 40 43 54 59 Trada Met $20.52 22.04 23.52 25.04 26.52 28.04 29.52 31.04 34.04 37.04 cabin#t lanffth Inchas 20 Vi 24 Vi 28Vi 32Vi 36 Vi 40 Vi 44Vi 48Vi 56 Vi 54 Vi No. 6 depth (6V4" cabinet) with 2Vi" flange unit no. 4 ft output approx. hipping woigM 24" CABINET HEIGHT 620-24 624-24 628-24 632-24 636-24 640-24 644-24 648-24 656-24 664-24 18.4 22.7 26.9 31.1 35.4 39.6 43.8 48.1 56.5 65.0 28 33 37 38 39 41 44 55 58 68 Trada Prtca $21.36 23.08 24.76 26.44 28.16 29.84 31.52 33.24 36.60 40.00 Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39. Special air vent assemblies. Trade Price......................................................................... each 91.80 Damper, chain type--standard length, Trade Price.......................................................each 2.10 Snap-On inlet grille, Trade Price .................................................................................... each 2.75 HH-3 Page 46 01661 American-Standard HYORONIC HEATINQ CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS CONVECTORS CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY 1. Chain type dampen .....................................................................................each 2. Metal trim strip* (type K only) .................................................................. each 3. Snap-on inlet grilles......................................................................................each 4. Special air vent assemblies........................................................................... each Trade Pried $2.10 2.75 2.75 1.80 SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS 1. Chain type dampen......................................................................................each 2. Knob type dampen....................................................................................... each 3. Marking or tagging-roomnumber or location............................................ each 4. Access doon-lilt-otl type ...................................................................... each 5. Access doon-piano hinge type ................................................................. each 6. Stool outlet-regular sheet price, plus................................................................ 7. Extra length-per inch or fraction thereof......................................................... 8. Rotary cam locks......................................................................................... each 9. Screws other than standard slotted type--per convector................................. 10. Grille reinforcing angles-6' centen--per grille......................... 11. Heavier gauge cabinets-trade price per iq ft of cabinet output: 2.10 2.90 .20 2.50 2.90 1.40 .60 .70 .30 1.00 (rents only No. 18 gauge ......................................................................... No. 16 gauge ......................................................................... $ . .. .04 No. 14 gauge ......................................................................... .09 12. Insulation--trade price per sq ft of cabinet output: back only Aerocor-1" thick compressible to t4"............................... $0.12 Wood Fiberboard-t4" thick................................................ Asbestos Millboard-Vi" thick............................................ .12 .12 Asbestos Millboard-Vi* thick............................................ .18 13. Front panels only: 50% of complete convector unit price (based on No. 6 depth) 14. Cabinet only: 70% of complete convector unit price 15. Providing round pipe holes or knockouts................................... 16. Providing special shape cutouts................................................... liners only $0.04 .06 .10 back, ends, and tap $0.18 .24 .24 .36 price on application price on application NOTES APPLICABLE TO MULTIFIN CONVECTORS ONLY: Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39. MINIMUM CABINET HEIGHTS WITH DAMPERS Multifin Convectors: Types FS, FSG Chain Typa Dampers 18" for #4 Depth 20" for #6 Depth 24" for #8 8c #10 Depths Knob Type Dampers 18" for #4 Depth 20" for #6 Depth 24'tor #8 6 #10 Depths Type S Arco Convectors: Types F, FG, W 14' for #4 It #6 Depths 18' for #8 (c #10 Depths 20' For All Depths 14' for #4 It #6 Depths 18' for #8 6 #10 Depths 20" For All Depths Types FS, FSG 24' for #4.#6 & #8 Depths 26' for ff 10 Depth 24' for #4.#6 6 #8 Depths 26'for #10 Depth Type S 18" for #4 Depth 20" for #6 Depth 26* for #8 6 # 10 Depths 18' lor #4 Depth 20" for #6 Depth 26" for #8 6 #10 Depths Types R, RG, RGB, RC, RCG. RCGB 24" For All Depths 20* For All Depths NOTE: Minimum heights lor Arco Convectors applicable to X-4 (underneath) connection only. Page 47 01662 HH-3 r- . - : > . '**'5. HRMS ' AMERicAN-^tandard HYDRO NIC HEATING TRADE PRICE BOOICs..r,, Illustrations and descriptions of Plate Nnmh.r* listed != thie price beet Trill tc in u,e current American- SUndard Heatlnf-Coollnf Products Catalog and literature. Items Illustrated In product literature and not Included In this price book are discontinued. The illustrations In this price book although actual representations of certain product In the line, do not necessarily show sizes and details of all products in the line. This book contains suggested Trade Prices for certain Hydronlc Heating products sold by American Radiator & Standard Sanitary Corporation ("American-Standard") through Its Plumbing and Heating Division. (AmericanStandard acting through that Division is hereinafter referred to as the "Seller"). The Seller assumes no obligation to sell to anyone at any price any of the items listed herein. All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein. INVOICE MINIMUM An order for Items for which invoice prices aggregate less than $1.00 will be billed at $1.00. TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH ITS PLUMBING AND HEATING DIVISION All sales of goods by American-Standard through its Plumbing and Heating Division are made subject to terms and conditions printed below, in Its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions are as follows: met Goods told by the Seller will be billed to the Buyer! according to the price* end term* contained in Its current bulletins end price books. In the cese of orders for foods for which no price Is currently in effect, the price will be determined by the Seller end eet forth In the Invoice issued efter shipment of the foods. Taxes. Any tsx or other Government chsrfe now or hereefter levied upon the production, sole, use or shipment of foods ordered or sold, will be chsrftd to and psld for by the Buyer. OIUVIRY Traeipertatlee Risks. Delivery to the initial carrier shell constitute de livery to the Buyer The Seller's responsibility ceeses upon delivery In food order to such earner, end ell foods sre shipped at the Buyer's risk. The Buyer Is urfed to examine ell dettvenes carefully before slgntng transportation receipts If foods are visibly damsfed. the Buyer should Insist that written confirmation of the damafe be noted on the frelfht bill or dray ticket by the afent of the carrier. If damafe Is discovered after unpacking the earner should be notified at once, so that Inspection can be made and the claimed damafe substantiated by the earner. Interference with Delivery. The Seller has no obligation to deliver goods against any order until it has accepted the order by Issuance of Its ac knowledgment of order In any event, the Seller will not be liable for any delay or failure in the delivery or shipment of foods against an accepted order or for any damages suffered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (In manufacture or other wise). fire, flood, not. war. embargo, tabor stoppages. Inadequate trans portation facilities, shortage of material or supplies, delay or default on the part of its vendor*, regulation by Government authortty, or any like or dissimilar cause or causes beyond its control. WARRANTY Except where s different express written warranty has been Issued with respect to particular products, no warranty, express or implied, is extended by the Seller to any person or persons other than its distributors snd other direct Buyer* To direct Buyers, the Seller warrants only that It will furnish by freight a replacement for. or at Its option lepalr. any product of its manufacture or part or portion thereof, proved to Its satis faction to be defective in material or workmanship under normal use and service within one year after installation. The Seller will not be respon sible for any damages whatsoever, or for labor expense, in connection with the replacement of defective products or parts or portions thereof This warranty is In lieu of all other warranties, express or Implied, and of all othe^ obligations or liabilities, on the part of the Seller The Seller neither assumes nor authorizes any other person to assume for it any other liabilities in connection with the sale of Its products except In the case of express wsrranties which may be Issued by It In writing from time to time with respect to particular products. Goods of other manufacturers sold by the Seller are not warranted except by express warranties which may be Issued In writing from time to time, with respect to particular products or particular sales, but the Seller will endeavor to secure for Its direct Buyers the benefits of war ranties extended by the manufacturers of such goods sold but not manu factured by the Seller. CONTIACT with tuna Aeceptaaee ef Orders. Order* will be accepted only by the Seller'* usual acknowledgment of order containing terms and conditions applicable thereto. No terms and conditions appearing In a Buyer s order that are at variance with the Seller's terms and conditions shall be binding upon the Seller unless specifically agreed to by it In writing. Unless the Seller spe cifically so agrees In writing In acknowledging any order, any terms and conditions appearing in a Buyer's order contrary to those stated herein and In such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt objection to the terms and conditions therein and herein set forth, constitutes acceptance by the Buyer of such terms and conditions. Cancellation ef Order*. After the Seller's acknowledgment of order ha* been issued, an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after a commitment has been made or production scheduled. Credit for Returned Geodi. Merchandise may not be returned for credit unleas the Seller has agreed to accept It. Where returns sre accepted, a deduction of 10% will be made for rehandling. All transportation costs for returned goods must be paid by the Buyer. In any event, only salable merchandise of standard manufacture may be returned for credit. Credit Approval. Buyer*' orders are accepted subject to credit Investiga tion and approval, and delivery may be withheld or shipment stopped In transit on accepted order* without any liability on the Seller's part. tf. In its opinion, the Buyer s ability to pay for the merchandise on these term* and conditions is in doubt. SHORTAGCS OR VARIANCCS No claims for variances from or shortages in order* will be considered unleu presented within CO days after receipt of goods. PRODUCT ANO PACKAGING CHAMOIS Faetors beyond the control of the Seller and the need for continuing improvement of product require the making of changes from time to urae in products and their packaging. The right Is reserved to makeressonaoie changes of any kind without notice and to deliver revised designs or moqels of goods against any order, unless on the face of the acknowieagmew* of order this right is specifically waived. The Seller ih.ll hive no reiponUblllty whitever with nitcl t chin made by the manufacturer in product# (or their packaging) aold out om manufactured by the Seller. SHIPPING WIIOHTS The shipping weights given herein are approximate.' lot f . venlcnce only, and are not guaranteed. AMERICAN RADIATOR & STANDARD SANITARY CORPORATION PLUMBING AND HEATING DIVISION Page 41 01663 *