Document X7Or9g5Ky16DRoqG8E5xjOOLy
..'. . ^
k ojffwiivj'~
*\fl a y ;
Krci^ortic
Heating Equipment
trade price book
*Hydronics ... the science of heating and cooling with water.
PRODUCTS
Boilers:
Gas--Packaged Units
Boilers Only
Electronic Control Systems
Oil --Packaged Units
Boiler--Burner Units
Boilers Only
Stoker Boilers
Hand fired Boilers
Radiation:
Baseboard Panels --Radiantrim
--Heatrim
Convectors
--Multifin
--Arco
--Cabinet Extras
Radiators--Arco, Sunrad, Peerless
Oil Burners and Controls
Zone Control Sets
Gas Conversion* Burners
Repair Parts Discounts
Terms
General Information
PAGE
3-d 7-14
15 16-17 18-29 18-29 34-35 36-38
40 42-43 44-46
41 47 39 30-32 30 33 2 48 2
f
HH-3
JUNE 4, 1962
notice: The Trode Prices shown herein do not include freight or cartage.
Ame rican-Standard
PLUMBING AND HEATING OIVISION
AMERICAN RADIATOR 4 STANOARO SANITART CORPORATION 40 WEST 40TH STREET NEW TORK IR, NEW YORK
PLAINTIFF'S EXHIBIT
01616
AMERiCAN-tStandard
GENERAL INFORMATION
HYDRONIC Hlf/TfKO ___________________________ __L-r. '......................................................... .....
.
BOILER RATlii
Boiler ratings ("net I=B=R ratings of Mbh and sq ft of
steam", "net rating sq ft water" and "installed radiation", wnere snowni represent the maximum net ioads that may be connected to tne boilers. Steam sq ft ratings are based on 240 Btu per sq ft and water sq ft ratings on 150 Btu (170* water) per sq ft. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heat ing domestic hot water under the following conditions:
It is not necessary to increase the boiler size for domestic hot water supply when not more than two bathrooms are to be served or if the use of domestic hot water does not exceed seventy-five gallons in twenty-four hours.
Sufficient radiation must be installed for the requirements of the building.
In order to select the proper size boiler calculate the heat loss of the building, then divide this figure by 1,000 to get the heat lcs? "cr.ressed in Mbh. Select a steam or water oouer which >, - J net Mbh rating equal to or greater than this flgi ; u :-, appropriate steam or water column.
See cn -ent literature for determining the size of radiators and convectors for hot water systems.
For an installation where unusual conditions such as large pipe losses, intermittent heating, unbalanced systems, etc . are encountered, it is suggested to calculate the actual piping loss and estimate the pick-up factor to adjust the load and then select the boiler from the published gross output in Mbh (1.000 Btu per hour).
GAS FIRED BOILERS
The input and output ratings are approved by the American Gas Association.
Ratings shown are for installations at sea level and at eleva tions up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS The firing rates or I=B=R burner capacity--gallons per hourare based on the use of oil having 140.000 Btu per gallon heat value, and with 10% COi in the flue gas.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
When Built-in Tankless Heater is used increase the boiler size 12 Mbh for each bathroom in excess of two.
STOKER FIRED BOILERS
The firing rates or I=B=R burner capacity pounds per hourare based on the use of coal having 13,000 Btu per pound heat value.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
HAND FIRED BOILERS
The ratings (installed radiation sq ft) are based on the use of stove or nut size bituminous coal, anthracite coal or coke with 13.000 Btu per pound heat value. See table below for select ing proper size boiler when using coal with less than 13.000 Btu per pound.
When more than two bathrooms are to be supplied with domestic hot water or when the demand for domestic hot water exceeds seventy-five gallons in twenty-four hours in crease the boiler size 120 Btu per hour for each gallon of stor age tank capacity.
BUILT-IN WATER HEATERS (for Arcoliner, Oakmont, Severn, Exbrook Boilers)
All tank type Built-in water heaters are rated on the basis of raising the temperature of the domestic hot water 100*F. in three hours with a minimum boiler water temperature of 180* F. on automatically fired boilers and 212*F. on hand fired boilers.
All tankless type Built-in water heaters are rated in gallons per minute on the basts of a minimum boiler water tempera ture of 180-F. on oil fired boilers. The maintaining of 180*F.
boiler water temperature with rated Sow through a tank less type Built-in water heater is dependent on the oil firing rate for the boiler.
In those areas where excessive lime exists in the water, use of Built-in Tankless Type water heater is not recommended except when provision is made for regularly cleaning the heater. Use of Tank Type heater is recommended in hard water areas.
WHEN PIPING LOSS IS NEGLIGIBLE
The load connected to steam boilers (all fuels) and coal (hand fired) water boilers may be increased by the percentages shown below when the piping loss of the installation is negli gible. The load connected to automatically fired water boilers may be increased by 12`7> when the piping loss of the installa tion is negligible.
load installed radiation a<| ft
Sttam (all fuals)
Watar coal (hand flrad)
ineraaao load
hy
up to 250 251- 500 501-1000 1001-1500 1501-2000 2001-3000 3001-4000 over 4000
up to 400 401- 800 801-1600 1601-2400 2401-3200 3201-4800 4801-6400 over 6400
30% 28% 24%
21% 18% 15% 13% 12%
WHERE COAL HAS LESS THAN 13,000 BTU CONTENT
When selecting hand fired boilers for burning coal of lower heating value than 13,000 Btu per pound the following correc tion factors should be used. Multiply the net load by the proper factor and select the boiler with the corresponding rating (installed radiation sq ft).
hasting value of coal
correction factor
13.000 ........................................................... 1.00
12.500 ........................................................... 1.04
12.000 ........................................................... 1.08
11.500 ........................................................... 1-13
11.000
1.18
10.500 ........................................................... 1.24
10.000
1-30
9,500 9,000
137 1.44
REPAIR PARTS-TRADE PRICES
--
Boilers (all fuels) ...................................................................................................................................Lis* Price, less 25%
Gas Conversion Burners .............................................. ........................................ . - Lf*J Price, less 25%
For List Prices see "American-Standard Radiator Heating Repair Parts Catalog 1956 Edition.
Oil Burners................................................................................................................ ............ .U*t Price, (ess 25%
For List Prices see "American-Standard Arcoflame Oil Burner Repair Parts Catalog" 1956 Edition.
MH 3
P|i 2
01617
AMERiCAN-<Standard
At
H V ?. |ONIC HE ATI KG
packaged borers
GAS f!RED
W*T,,
PACKAGED "GPR" American-Standard GAS BOILERS
rui Nuturui, mixeu/ iViuiiwiu.iwrcu cine IP Gases
Designed and equipped with controls for tent-s^us forced circulation
Factory assembled and crated. Built-in air-separator m top section.
^
A G.A. approved for combustible floors and closet installations
WATER ONLY
packaged boiler
number
GPR-60 GPR-80 WATER ONLY GPR-60 GPR 80
FOR NATURAL, MFD., MIXED GASES ONLY
A.G.A. Input Mbh
75 100
A.G.A. output
Mbh
60 80
not isBsR
Mbh*
45 60
not rating sq. ft. watr
300
400
Trad* Price with
standard equipment
$225.00
245.00
chimney size
diameter inches
5 5
height feet
20 20
FOR PROPANE AND BUTANE GASES ONLY
70 56 42 280 $225.00 5 20 95 76 57 380 245.00 5 20
epproz. shipping
weight
205 235
205 235
Standard equipment all boilers:
V-600 combination diaphragm gas valve furnished for all gases V-600 fea tures built-in gas pressure regulator (except for LP gas) and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated round jacket; Transformer; ASME relief valve (30 lbs); Theraltimeter (30 lbs); Wiring harness; 1" circulator; CB-580 thermostat; AY-553 limit control
Controls regularly furnished are for 115 volt. 60 cycle current.
Not*: Packaged boilers are shipped with jacket, all controls (except thermo stat), circulator, mam burners and manifold controls and piping factory in stalled and wired. CB-580 thermostat, manual shut-off valve, relief valve and drafthood shipped inside boiler crate.
Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level.
For ordering instructions for gas boilers, see page 15.
Optional Equipment: (only those below available)
Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes.
Zone Control Valve Sets available for water boilers, for details and prices, see page 30.
Self-energizing controls (consist of special gas valve, thermostat, pilot burner, limit control) for all gases listed above, available when specified on order at no additional charge.
Not*: in areas where manual opening feature is normally desired, we will furnish "GPR" boilers with Self-energizmg controls as shown above. V-600 gas valves with manual opening for "GPR" not available.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 3
01618
HH 3
packaged boilers
GAS FIRED
WATS*
American-^Standard
HYDRO NIC HE (VINO
PACKAGED G-2 "FPB" AiWERiCAN-^tandard GAS BOILERS
Fui' Nuiuiu', mixeu, manufactured Gases Designed and equipped with controls tor forced circulation. Factory assembled and crated. Flush jacket only. ''Elimtnaire" (cast-in air eliminator in left end sectionl
WATER ONLY
packaged bailer number
G23-FPB G-24FPB G-25-FP6 G-26FPB G-27FPB
A.OJL input Mbh
60 90 120 150 180
A.OJi. output
Mbh
48 72 96 120 144
nat l=B=R rating
Mbh
36 54 72 90 108
nat rating aq. ft. water
240 360 480 600 720
Trade Price with
standard equipment
$255.00
283.00 319.00 361.00 412.00
chimney size
diameter inchea
4 5 6 6 6
height faet
20 20 20 20 20
approx. hipping
weight
317 377 457 542 632
Standard equipment all boilers:
V-600 combination diaphragm gas valve furnished with Natural. Manufac tured. Mixed gas boilers. V-600 features built-in gas pressure regulator and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; 1V*" circulator.
CB-580 thermostat, CB-6S5 immersion limit control.
Left hand end section without tankless heater opening.
Controls regularly furnished are for 115 volt, 60 cycle current.
Note: Packaged boilers are shipped with jacket, all controls (except thermo stat) , circulator, main burners and manifold controls and piping factory in stalled and wired. CB-580 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea leveL
For ordering instructions for gas boilers, see page 15.
Optional Equipment: (only those below available)
Runner Type Pilot Ignition for use with listed gases furnished at no charge when specified on order to meet local utility codes. Floor Shield for Combustible Flooring. Add suffix letter "C" to boiler num ber and add 83.00 to Trade Price of boiler. Pilot Filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes. Manual Opening Feature on V-600 gas valve furnished at no additional charge when specified on order to meet local utility codes. Zone Control Valve Sets available for water boilers, for details and prices, see page 30.
For complete information on boiler retings, see page 2. For discount on repaid** tee page 2.
HH-3
Page 4
01619
AMERiCAN-<Standard
HYDRONIC H E A ? -**
PACKAGED BOILERS ^AS FIRED
WATT*
PACKAGED G-2 AMEniCAN-<$tandard GAS BOILERS
Designed and equipped with controls lor forced circulation. Factory asssmbled and crated. Flush or Deluxe jacket. Sections tested for 30 lbs. water working pressure. "Eliminaire1' (cast-in air eliminator in left end section).
WATER ONLY
packagad bolter
numbtr
A.GUA. input
MWi
oAu.OtpAu.t
Mbti
tanUatft
A
haatar IsWsrH
numbar ratine
Mfd,, Note Mlxad and LP Oat; LP*Alr Gas 525*1400 Btu
nat l=B=ft
ratine Mbh
nat ratine
aqft water
Trada Prica with atandard
aquipmant
fluah Jacfcat
dafuia Jackal
chlmnay tlza
dlamatar Haight
inchat
fa at
approx. hipping
waigtit
Packaged boiler* without tankless heater
G-23P G-24-*P G-25-*P G-26-*P G-27-*P
60 90 120 150 180
48 72 96 120 144
36 240 $271.00 $285.00 4 20 315 54 360 328.00 342.00 5 20 375 72 480 372.00 386.00 6 20 455 90 600 413.00 427.00 6 20 540 108 720 449.00 463.00 6 20 630
Packaged boilers with factory installed tankless heater
G-24-*PT 90 72 218 2Vz 54 360 $361.00 $375.00 5 20 390
G-25-*PT 120
96 222 3
72 480 407.00 421.00 6 20 470
G-26-*PT 150 120 222 3l/< 90 600 448.00 462.00 6 20 550
G-27-*PT 180 144 222 3'A 108 720 484.00 498.00 6 20 642
AGallons of water par minute heated from 40F to 140F with 200F boiler water temperature. "Subetitute letter *'p' for flush or *'0" for deluxe jacket.
Standard equipment all boilers: (see options, page 9)
V-600 combination diaphragm gas valve furnished for Natural, Manufactured, Mixed. LP-Air, and LP gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. Manual shut-off valve; Pilot cock; Pilot filter (for manufactured gas and S.U.R.); Boiler drain; Draft hood; Insulated jacket; Transformer; ASME relief valve (30 lbs.); Theraltimeter (30 lbs.); Wiring Harness; 1 Vs" circulator with piping. Controls regularly furnished are for US volt. 60 cycle current.
Additional standard equipment for boilers with heater:
Tankless heater as listed above. RS-116-F combination immersion control (high and low limits, circulator operation, transformer and built-in relay). CB-520 thermostat.
Additional standard equipment for boilers less heater: CB-520 thermostat, combination immersion high limit and reverse acting control.
Left hand end section without tankless heater opening.
Note: Packaged boilers are shipped with jacket, all controls (except thermostat), cir culator and piping, main burners and manifold controls and piping factory installed and wired. CB-520 thermostat, manual shut-off valve and relief valve shipped fastened inside boiler crate. Draft hood shipped in separate carton for flush jacketed boiler and G-23-DP.
Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level.
For ordering instructions for gas boilers, see page 15.
i For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 5
HH-3
01620
PACKAGED BOILERS GAS FIRED
WATII
AMEMCANvStandard
HYDRONIC HEATING
n m ^t/ a
rwaMvitu
MLL
-PURPOSE
G-2
AMtRiCASi Standard
GAS
BOiLERS
Designed for forced or gravity circulation. Factory assembled and crated. Deluxe Jacket. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section)
WATER ONLY
packaged toiler
number
G-23DPG G-24DPG G-25DPG G-26DPG G-27DPG
A.G.A.
Input Mbh
A.G.A.
output Mbh
Mfd., Nat., Mixed and LP Gat; LP-Air Gat 525-MOO Btu
net IsBsR rating
Mbh
60 48 36
90 72 54
120 96 72
150 120
90
180 144 108
net rating 4 ft water
240
360
480
600
720
Trade Price with
standard
equipment
chimney size
diameter inches
height feet
$208.50 4 20 265.50 5 20 309.50 6 20 350.50 6 20 386.50 6 20
approx. shipping weight
317
377 457
542 632
Standard equipment: (see options, page 9)
V-600 combination diaphragm gas valve furnished for all gases. V-600 fea tures built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch.
Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.UJL); boiler drain; draft hood; insulated jacket; transformer. G-23-DPG furnished without heater opening in left end section.
Water only:
Theraltimeter; ASME relief valve; CB-6S5 immersion limit control. Controls regularly furnished are for 115 volt, 60 cycle current. Room thermostat not included in above prices.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For elevations above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet, above sea level.
For ordering instructions for gas boilers, see page 15.
a For complete information on ratings, see page 2. For discount on repairs, see page 2.
HH-3
Page 6
01621
AMERiCAN-<Slandard
HYDRONIC HEATING
BOILERS--GAS FIRED STEAA? and WATER
G-2 ALL-PURPOSE AMERiCAN-fStandard GAS BOILERS
Designed (or water (forced or gravity) or steam. Flush or Deluxe jacket. Factory Assembled Sections. Sections tested for 30 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section)
WATER (Available with factory installed Tankless heater, see options, page 9.)
boiler number
A.(LA. Input Mb*
A.GJta output
MM- Nat- Milad
and LP Gee; LP-Air Ga* 525-1400 Btu
B nat l8R rating
Mbh
nat rating
aq ft watar
Trada Price with standard
aquipmant
flush Jacket
deluxe jacket
G-23--G 60 48 36
G-24-G 90 72 54
G-25-*G
120
96
72
G-26--G 150 120
90
G-27-*G 180 144 108
G-28--G 210 168 126
G-29-G 240 192 144
G-210-G 270 216 162 G 211-G 300 240 180
240 360 480
600 720 840
960 1080 1200
$187.00 244.00 288.00
329.00 365.00 407.00
449.00 480.00 526.00
$201.00 258.00 302.00
343.00 379.00 421.00
463.00 494.00 540.00
chimney size
diamatar Inchat
height feat
4 20 5 20 6 20
6 20 6 20 7 20
7 20 7 20 7 20
STEAM
boiler
G-23-*G G-24--G G-25-G G-26-G G-27--G G-28-'G G 29-G G-210-G G-211-G
A.GJL input Mbh
A.GJt. output
Mbh
Mfd- Nat- Mixed end LP Gas; LP-AIr
Gas 525-1400 Btu
60 48 90 72 120 96
150 120 180 144 210 168
240 192 270 216 300 240
nat IsBsR rating
Mbh
36 54 72 90 108 126 144 162 180
sq ft
150 225 300 375 450 525 600 675 750
'Substitute letter "F" for flush or "O'* for deluxe jacket.
Trada Priea with standard
equipment
flush jacket
datuxa Jacket
$224.00 281.00 325.00
366.00 402.00 444.00
486.00 517.00 563.00
$238.00 295.00 339.00
380.00 416.00 458.00
500.00 531.00 577.00
chimney size
diameter inches
4 5 6
6 6 7
7 7 7
height feet
20 20 20
20 20 20
20 20 20
Standard equipment: (see options/ page 9) V-600 combination diaphragm gas valve furnished with G-23 througn G-29 Natural, Mixed, LP-Air. LP gas boilers and G-Z3 through G-27 Manufac tured gas boilers. V-600 features built-in gas pressure regulator (except for LP Gas) and thermocouple type safety pilot switch. V-S32 diaphragm gas valve furnished for all gases for sizes not listed above with separate gas pressure regulator (except LP) and Baso switch. Manual shut-off valve; pilot cock; pilot filter (for manufactured gas and S.U.R.); boiler drain; draft hood; insulated jacket; transformer.
Water only: Theraltimeter; ASMS relief valve; CB-6S5 immersion limit control.
Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; external resetting low water cut-off; floor pan.
Controls regularly furnished are for US volt. 60 cycle current. Room thermostat not included in above prices. Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level. For ordering instructions for gas boilers, see page IS.
For complete information on ratmgs, see page 2. For discount on repairs, see page 2.
Pat* 7
approx. shipping
weight
277 353 428 490 553 629 697 761 841
approx. weight
287 363 438 500 563 639 707 771 851
HH 3
01622
BOILERS--OAS FIRED
WAT* AMO fTlAM
AMERiCAN-cStandard
HYDRONIC R EATING' G-2 ALL-PURPOSE AMERiCAJtf-<$tandard GAS BOILERS
DIRECT TYPE -- Water boilers for hot water supply Flush or Deluxe Jacket. Hydrostatically tested at 200 lbs. Working pressure 80 lbs. Not recommended (or use in hard water areas.
boiler number
A.G.A.
Input Mbh
A.GJL rating--gallons weter per hour output
Mbh 60* rise 80* rise 100* rite
U(d Nat. Mixed and LP Oat; LP-AIr Cat 525-1400 Btu
Trade Price with "OW* equipment
flueh Jacket
If
approx. shipping
weight
G-23*G
60 48
G-24-*G
90 72
G-25-*G 120 96
G-26-'G G-27*G G-28-*G
150 120 180 144 210 168
G-29-*G 240 192 G-210-*G 270 216 G-211-*G 300 240
96 72 144 108 192 144 240 180 288 216 336 252 384 288 432 324 480 360
58 86 115
144 173 201
230 260 288
$201.00 258.00 302.00
343.00 379.00 421.00
463.00 494.00 540.00
$215.00 272.00 316.00
357.00 393.00 435.00
477.00 508.00 554.00
277 353 428
490 553 629
697 761 841
'Substitute letter "F" for flush or "0" for deluxe jacket.
"DW" standard equipment: (see options, page 9)
In addition to boiler (or water with "standard equipment" page 7. "DW" boilers are furnished with Ther-pressure-meter instead of Theraltimeter; 80 lb. ASMS relief valve instead of 30 lb. valve; immersion operating control for use in storage tank; tank ther mometer; name and rating plate for 80 lbs. working pressure.
For ordering instructions for gas boilers, see page 15.
Controls regularly furnished are for 115 volt, 60 cycle current.
Ratings shown are for installations at sea level and at elevations up to 2.000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
FOR USE WITH "IS" EQUIPMENT
INDIRECT TYPE --Sfeom boilers for hot water supply Flush or Deluxe jacket.
boiler number
A.GJL Input Mbh
A.GJL. rating--gallons water per hour output Mbh 60* rise 80* rise 100* rise
Mfd- Nat, Mixed and LP Gas; LP-AIr Gas 525-1400 Btu
Trade Price
with MiSH
equipment
flush Jecket
deluxe Jecket
approx. shipping
weight
G-23-*G G-24--G G-25-*G
G-26-G G-27*G G 28-*G
G 29 *G G-210-'G G-211-G
60 90 120
150 180 210
240 270 300
48 72 96
120 144 168
192 216 240
96 72 144 108 192 144
240 180 288 216 336 252
384 288 432 324 480 360
58 86 115
144 173 201
230 259 288
$234.00 291.00 335.00
376.00 412.00 454.00
496.00 527.00 573.00
$248.00 305.00 349.00
390.00 426.00 468.00
510.00 541.00 587.00
287 363 438 500 563 639 707 771 851
'Substitute letter "F" for flush or "0" for deluxe jecket.
"IS" standard equipment: (see options, page 9)
In addition to boiler for steam with "standard equipment" page 7, "IS" boilers are furnished with immersion operating control for use in storage tank.
For ordering instructions for gas boilers, see page 15.
Controls regularly furnished are for 115 volt. 60 cycle current.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For
altitudes above 2.000 feet, ratings should be reduced at the rate of 4% for each 1,000
feet above sea level.
*
For discount on repairs, see page 2.
HH-J
Page g
01623
American-Standard
HYDRO NIC HEATING
BOILERS--GAS FIRED STEAM AND WATER
G-2 OPTIONAL EQUIPMENT
ALL BOILERS (Pages 5 thru 8): Runner type pilot ignition (or use with listed gases furnished at no charge when specified on order to meet local Utility codes. Push button electric ignition (or use with listed gases. Not available with self-energizing controls. Specify on order and add $11.85 to Trade Price of boiler.
Floor shield for combustible flooring. Add suffix letter "C" to boiler number and add $3.00 to Trade Price of boiler.
Pilot filter for natural or mixed gas furnished at no charge when specified on order to meet local utility codes.
Manual opening feature on V-600 or V-532 gas valves fur nished at no additional charge when specified on order to meet local utility codes.
Zone control valve sets available for water boilers, for details and prices, see page 30.
PACKAGED GAS BOILERS (Page 5 only): only those
options listed above applicable to these boilers.
PACKAGED ALL-PURPOSE BOILERS (Page 6 only): Tankless heaters: when boilers (4 thru 7 section) are to be used for forced circulation I=W=H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately only at the "sold separate" Trade Prices shown below.
Self-energizing controls (consists of special gas valve, pilot burner, limit control) for mfd.. natural and mixed gas. avail able when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32.
Room thermostat prices shown on page 32.
ALL-PURPOSE BOILERS (Page 7 only): WATER BOILERS ONLY:
Factory installed tankless heaters: when boilers (4 thru 11 sec tion) are to be used for forced circulation I=W=H tankless heaters can be specified factory installed, but limited to cer tain boiler sizes. See table below for I=W=H ratings and applicable boiler size. If desired, add suffix letter "T" to boiler number and "factory installed" Trade Prices shown below.
ALL-PURPOSE BOILERS (Page 7 only):
WATER BOILERS ONLY: (continued)
Tankless heaters: when boilers (4 thru 11 section) are to be used for forced circulation I=W=H tankless heaters can be installed in opening used for gravity tapping flange cover, but limited to certain boiler sizes. See table below for I=W=H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
STEAM BOILERS ONLY:
McOonnell-Miller No. 101-24V Electric Water Feeder can be added to the No. 67 Low Water Cut-off furnished with G-2 All-Purpose Steam Boilers to provide Low Water Cut-off and Feeder Combination. If desired specify on order and add $37.07 to Trade Price of Steam Boiler.
Side Outlet Pop Valve may be substituted at no additional charge if specified on order to meet local code requirements.
WATER OR STEAM BOILERS: Self-energizing controls (consists of special gas valve, pilot burner, limit control, low water cut-off for steam boilers) for mfd., nat. and mixed gas, available when specified on order at no additional charge. Special thermostat required, for Trade Price, see page 32.
Room thermostat prices shown on page 32.
Dual-gas boilers: available for both natural and propane gases. See below for added charges. Boiler prices on Page 7
boiler no.
G-23 G-24 G-2S G-26 G-27
added charge
$50.00 52.00 54.00 56.00 58.00
boiler no.
G-28 G 29 G-210 G-211
added
charge
$60.00 62.00 64.00 66.00
Equipment includes in addition to standard trim two V-532 gas valves,
two manifolds with spuds factory assembled, outdoor changeover control.
G-2 Tankless Heaters
boiler number
G-24 G-25 G-26 G-27 G-28 G-29 G-210 G-211
Ratings
A.CUL Input Btu/hr.
heater i
218
IsWsH Rating e
heater 222
heater 226
heater 4
232
90.000 120.000 150,000 180,000 210.000 240,000 270,000 300,000
2 Vi -- -- --
--3
----
-- 3% -- --
-- 3 Vi 4
--
--
3 Vi 4 Vi
--
--
3 Vi 4 Vi
4 Vi
--
3 Vi 4Vi
4%
--
3Vi 4Vi
5
Gallons watsr per minute heated from 40*F to 140*F with 200*F boiler water temperature.
A lost two digits designate lineal feat of Tru Fin tubing in heater coil.
Trad* Prices
heater number
218 222 226 232
factory installed
$41.00 43.00 51.00 55.00
sold separate
$19.00 21.00 29.00 33.00
Factory installed additional price includes RS-116-F packed in tnm boa.
Page 9
HH-3
01624
TOILERS--GAS FIRED
fTCA* AND WATCt
American-Standard
HYDRONIC HEATING
WATER
boiler nvmhar
6403 6404 6-405 6-406 6407 6408 6409 64010
STEAM
better amber
6403 6404 6405 6406 6407 6408 6409 64010
WATER
bailer number
6403 6404 6405 6406 6407 6408 6409 64010
STEAM
boiler amber
6403 6404 6405 6406 6407 6408 6409 64010
A.C.A. input
Mbti
150 225 300 375 450 525 600 675
A.C.A. inpet
Mbh
150 225 300 375 450 525 600 675
JLC.A. input
Mbh
120 180 240 300 360 420 480 540
A.C.A. fnpat
Mbh
120 180 240 300 360 420 480 540
G-40 AMERicAN-<Slandard CAS boilers For Built-In Water Heater Arrangement, see page II. Deluxe jacket.
Tested and equipped for 50 lbs. water working pressure. "Eliminaire" (cast-in air eliminator in left end section).
FOR NATURAL,
A C A. output
Mbh
not l = B = Pt
ratinf Mbh
MFD., MIXED, GASES
net
ratine *0- tt. water
Trade Price
with standard equipment
ONLY
chimney sue
diam. inches
ht. ft.
120 900 600 $360 00
180 135 0 900 462.00
240 180.0 1200
567.00
300 225.1 1500
693.00
360 270.1 1800
788 00
420 315.1 2100
893.00
480 360.1 2400
977.00
540 405 1 2700 1071.00
6 20 7 20 7 20 8 20
8 20 9 20 10 20 10 20
A.C.A. tftput
Mbh
att 1 = 1 = A ratine
Mbh
sq. ft.
Trade Price with standard
equipment
chimney sue
diam. inches
ht. ft.
120 90.0 180 135.0 240 180.0
300 225.1
375 $397.00 563 499.00
750 604.00
938 730.00
6 20 7 20 7 20
8 20
360 270.1
1125
825.00
8 20
420 315.1 1313
930.00
9 20
480 360.1 1500 1014.00 10 20
540 405.1 1688 1108.00 10 20
FOR LP AND LP-AIR GAS ONLY
A.C.A. eutput
Mbh
net ratine Mbh
nat
ratine sq. ft. water
Trade Price
with standard equipment
chimnay size
diam. inches
ht. ft.
96 72.0 480 $360.00
144 108.0 720 462.00
192 144.0 960 567.00
240 180.0 1200
693.00
6 20 7 20 7 20 8 20
288 216.1 1440
788.00
8 20
336 252.1 1680
893.00
9 20
384 288.1 1920
977.00 10 20
432 324.1 2160 1071.00 10 20
A.C.A. output
Mbh
96 144 192 240
288 336 384
432
net 1 = 1 = R ratine
Mbh
72.0 108.0 144.0 1803)
216.1 252.1 288.1 324.1
sq. ft.
300 450 600 750
900 1050 1200 1350
Trade Price with standard
equipment
$397.00 499.00 604.00 730.00
825.00 930.00 1014.00 1108.00
chimny size
diam. Inches
ht. ft.
6 20 7 20 7 20 8 20
8 20 9 20 10 20 10 20
apprex. thippinf wti|ht
827 998 1162 1349 1517 1686 1856 2026
epprei. shippmf weifht
858 1027 1195 1370 1544 1713 1880 2050
approx. shippmc weifht
827 998 1162 1349 1517 1686 1856 2026
approx. shippinc weicht
858 1027 1195 1370 1544 1713 1880 2050
Standard equipment includes: (see options, pages 11 and 15)
V-531 diaphragm gas valve with manual opening feature; Baso automatic pilot switch for non-100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves. Optional other gases at no additional charge); manual shut-off valve; pilot filter (mfd gas and
SUR); gas pressure regulator (except for LP gas); boiler drains and pilot cocks; insulated jacket; draft hood; water heater opening cover plates.
Water only: Theraltimeter; ASME relief valve for 50 lbs.; CB-655 immersion limit control.
Steam only:
Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass
with trimmings; external resetting low water cut-off.
Controls regularly furnished are for 115 volt. 60 cycle current.
Ratings shown are for installations at sea level and at elevations up to 2,000 feet.
For elevations above 2,000 feet, ratings should be reduced at the rate of \% tor each
1.000 feet above sea level. '
Room thermostat not included in above prices.
For complete information on optional equipment, see pages 11 and 15.
For ordering instructions for gas boilers, see page 15.
__________________
* For complete information on boiler ratings, see page 2 For discount on repairs, see page 2.
mh 3
Page 10
01625
American-(Standard
HYDRONIC HEATING
BOILERS - GAS FIRED
STEAM AMO WATIR
G-40 optional equipment
BOILERS WITH TAKra.'r,* HEATERS: water (tor forced circulation) and steam boi<eps can be flushed with tankless heaters Some heaters are limited :o certain ooi.er sizes as shown m ratings table below
Tankless heaters with controls for water boilers: RS 116 F packed m trim Bo m place o< CB 655 lor stanoaro equipment
Tankless heaters with controls for steam boilers: additional CB 666 immersion operating control packed in trim box.
If tankless heaters with controls are desired, specify on order with boiler and add to Trade Price of boiler with standard equipment the following charges
Tankless heaters less controls will be furnished when specified at the Trade Prices shown below for heaters only.
HEATER NO.
216 222 226 232 445
HEATER WITH CONTROLS
Water
Steam
$41 00 43 00 51 00 55 00 72 00
S29 00 31 00 39 00 43 00 60 00
HEATER ONLY
Water er Steam
$19.00 21 00 29.00 33.00 50 00
Water flow regulators sized for tankless heater involved will be fur nished with heater when specified on order to meet local Utility require ment at S2 00 Trade Price additional charge per heater.
Factory assembled sections: G-403 through G-406 can be shipped with sections factory assembled when specified on order. If desired less tankless heater, add SIS.00 to Trade Price of boiler if desired with fac tory installed tankless heater, specify heater number, and add 515.00 plus price of heater to Trade Price of boiler
Dual Gas Equipment: available with steam or water boilers for use with Natural and Propane gases only In addition to standard trim, dual gas equipment includes tube withm a tube manifold, two V-S32 gas valves, gas pressure regulator (natural gas only), two manual shut-off valves, ribbon burners. 100% shut-off (consists of Baso combination pilot valve and switch with auxiliary Baso pilot valves), pilot cock, outdoor thermostatic adjustable changeover control. Boiler selection should be based on the A.G.A and i-BbR ratings shown for LP gas. If desired specify on order and add to Trade Price of boiler with standard trim the following charge:
Boiler Number
G-403 G-404 G-40S C-406
Add to Biller Trade Price
560 00 62.00 64 00 66 00
Boiler Number
G-407 G-408 G-40 9 G-4010
Add to Boiler Trade Price
$68.00 70 00 72.00 74.00
Electronic Control Systems: available with steam or water boilers. If desired refer to page 25 for complete details end additional Trade Price charges.
F.M. and F.I.A. equipment: requires EG O or EPG-O electronic control system and special gas control equipment. Available price on appli cation.
Tri-cock tappings and valves: if desired for steam boilers to meet local code specify on order and add 54 00 to Trade Price of steam boiler.
Self-energizing controls: available for steam or water (gravity) less tankless heater for natural and mixed gases only Eouipment includes special gas valve, pilot burner, limit control, low water cut off for steam boilers Furnished at no additional charge when specified on order. Special room thermostat required, lor Trade Price see Page 32.
McOonnell-Miller No. 101*24 Volt Electric Water Feeder can be added to No 67-GAR low water cut-off furnished with G-40 Steam Boilers to provide low water cut-off and feeder combination. If desired specify on order and add 537 07 to Trade Price of steam boiler
McOonnell-Miller No. 47-2 low water cut-off and feeder combination may be specified in place of regularly furnished No. 67-GAR for steam boilers. If desired specify on order and add 533 00 to Trade Price of steam boiler.
McOonnell-Miller No. 247-2 lew water cut-off and feeder combination for water boilers is available with G-40 Water Gas Boilers when specified on order. Add to the Trade Price of the water boiler with regular equipment the current Trade Price of this item shown m the current McOonnell-Miller Price Sheet.
Runner type pilot ignition: all sizes of G-40 are available with Runner type pilot ignition for mfd., nat. and mixed gas non-100% shut-off at no additional charge when specified on order to meet local Utility codes
Push button electne ignition: alt sizes of G-40 are available with push button electric ignition for use with mfd., nat. and mixed gas non-100% shut-off and will be furnished when specified on order at 511-65 added charge.
Pilot filters for G-40 for natural and mixed gases available at no addi tionai charge when specified on order to meet local utility codes.
Room thermostats available at Trade Prices shown on Page 32.
"IS" Equipment: G-40 Gas Boilers can be furnished for use with In direct Steam Hot Water Supply systems. CB-666 immersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on Page 32.
V-532 Diaphragm Gas Valve without manual opening may be substi tuted for V-531 Gas Valve with manual opening at no additional charge. If desired, specify on order.
Side Outlet Steam Pop Valves may be substituted at no additional charge if specified on order to meet local code requirements.
Jacket Extension: covers all controls on left end of boiler. If desired, specify on order and add $25.00 to Trade Price of Boiler.
G-40 Tankless Heater Ratings (Gallons per minute9)
Boiler
6-403 6-404 6-409 6-401 6-407 6-401 C-40B 6-4010
HEATER 211
Steam
Water
34 3V5r 4 3V* 4
4 3V* 4 3Vi 4 3 V2 4 3V^ 4
MUTER 222
Steam
_
4 4 4 4 4 4 4
Water
_
4V* 4V4 46 4V* 4V* AVi 4V*
MUTER 226
Stum
-- '--
5V4 5V*
6 6 6 6
Water
-- -- 6 6 6Vi 6Vt 6V* 6V*
MUTER 232
Steam
-- -- -- --
7 7 V* 7W 7V*
Water
-- -- -- -- VA
6 8 8
HEATER 44S
Steam
Water
------ ---- ---- ---- sv* 9 aw 9 8Vt 9
*Go//onf of wofer per minutt roued from 40*F. fo I40*F. toff two digits of heater numbers indicofe fineof feef of Tru-fin tubing in beater coif.
Page 11
01626
HH 3
ftOlUfcS ---GAS -HUD
fTtAJA
tfATCft
American-Standard
:** C-V??-* O N I C ?H'CAT-1-Na
6-60 A'iEniCAN-Standard GAS BOILERS
WATER
Mlr number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G6031 G-6033 G-6037 G-6041
STEAM
boilar number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G.6037 G-6041
A.CLA. Input
Mbh
725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 S220 5800
A.GJt. input
Mbh
725 870 1015 1160 1305 1450 1740 2030 2320 2610 2900 3045 3480 3915 4350 4640 5220 5800
ff r/ttfrea!. Mixed. Manufactured Gases Jacketed. Tested and equipped tor 50 lbs. water working pressure. Available tor 50 lbs. working pressure on special order.
A.OJL output
Mbh
580 696 812 928 1044 1160
1392 1624 1856 2088 2320 2436
2784 3132 3480 3712 4176 4640
not lsB=R ratine Mbh
435.1 522.1 609.2 696.2 783.2 870.2
1054.5 1248.3 1438.8 1621.1 1801.2 1891.3
2161.5 2430.1 2701.9 2880.4 3245.3 3602.5
net ratine sq ft wator
2900 3480 4060 4640 5220 5800 7030 8320 9590 10805 12010 12610 14410 16200 18010 19205 21635 24015
Trad* Price
standard equipment
$ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00
2092.00 2408.00 2711.00 3020.00 3329.00 3533.00
3967.00 4296.00 4895.00 5184.00 5803.00 6421.00
ehimnay il
diam. in.
ht ft
n 20 12 20 13 20 13 20 14 20 15 20
15 20 16 20 16 30 17 30 18 30 19 30
20 30 21 30 22 30 24 30 26 30 26 30
A.GJt. output
Mbh
580 696 812 928 1044 1160
1392 1624 1856 2088 2320 2436
2784 3132 3480 3712 4176 4640
not l=B =R ratine
Mbh
tq ft
435.1 522.1 609.2 696.2 783.2 870.2
1054.5 1248.3 1438.8 1621.1 1801.2 1891.3
2161.5 2430.1 2701.9 2880.4 3245.3 3602.5
1813 2176 2538 2901 3263 3626
4394 5201 5995 6755 7505 7880
9006 10126 11258 12002 13522 15010
Trado Price with standard equipment
$ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00
2129.00 2445.00 2748.00 3057.00 3366.00 3570.00
4004.00 4333.00 4932.00 5221.00 5840.00 6458.00
ehimnay sizs
diam. in.
ht ft
a 20 12 20 13 20 13 20 14 20 15 20
15 20 16 20 16 30 17 30 18 30 19 30
20 30 21 30 22 30 24 30 26 30 26 30
approx.
weight
2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316
approx. swhiepipgihnte
2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346
Standard equipment includes: (see options, pages 14 and 15)
V-S31 diaphragm gas valve with manual opening feature: Baso automatic pilot switch tor non-100% shut-off (100% shut-off controls consisting of Baso combination pilot switch and valve with auxiliary Baso pilot valves, optional at no additional charge); manual shut-off valve; pilot Alter (mfd gas and SUR): gas pressure regulator; boiler drains and pilot cocks; insulated jacket; draft hood; transformer.
Water only: Theraltimeter and ASME relief valve for 50 lbs.; CB-655 immersion limit control.
Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off.
Controls regularly furnished are for 115 volt, 60 cycle current.
Ratings shown are lor installations at sea level and at elevations up to 2.000 feet. For elevations above 2,000 feet, ratings should be reduced at the rate of 4% for each 1.000 feet above sea level.
Room thermostat not included in above prices.
For complete information on optional equipment, see pages 14 and 15.
For ordering instructions for gas boilers, see page 15.
___
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-3
Page 12
01627
American-Standard
HVhUOMIC HEATIN6
BOILUS-GAS FUtED rrtA* am wars*
G-60 AMKRiCAN-f$tandard GAS BOILERS
far Lr ana Lr-Air Sa vniy
Jacketed. Tested and equipped for 50 lbs. water working pressure. Available for BO lbs. working pressure on special order.
WATER
Mltr number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G 6028 G-6031 G-6033 G-6037 G-6041
STEAM
boiler number
G-606 G-607 G-608 G-609 G-6010 G-6011 G-6013 G-6015 G-6017 G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G-6037 G-6041
A. (LA.
'SSh
650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200
A.G.A. Input
Mbh
650 780 910 1040 1170 1300 1560 1820 2080 2340 2600 2730 3120 3510 3900 4160 4680 5200
A.GJL. output
Mbh
520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160
A.Q.A. output
Mbh
520 624 728 832 936 1040 1248 1456 1664 1872 2080 2184 2496 2808 3120 3328 3744 4160
not l=6=R rating Mbh
390.1 468.1 546.1 624.2 702.2 780.2
936.2 1108.1 1282.0 1452.3 1614.9 1695.7 1937.9 2180.1 2422.4 2585.4 2903.7 3229.8
nt ratine q. ft. water
2600 3120 3640 4160 4680 5200
6240 7385 8545 9680 10765 11305
12920 14535 16150 17235 19360 21530
nat l=B sR rating
Mbh
390.1 468.1 546.1 624.2 702.2 780.2
936.2 1108.1 1282.0 1452.3 1614.9 1695.7
1937.9 2180.1 2422.4 2585.4 2903.7 3229.8
sq. ft.
1625 1950 2276 2601 2926 3251
3901 4617 5342 6051 6729 7065
8075 9084 10093 10773 12099 13458
Trad* Price with
standard aqulpmant
$ 961.00 1118.00 1283.00 1461.00 1638.00 1783.00
2092.00 2408.00 2711.00 3020.00 3329.00 3533.00
3967.00 4296.00 4895.00 5184.00 5803.00 6421.00
chimnsy tlra
diam. in.
ht. ft.
n 20 12 20 13 20 13 20 14 20 15 20
15 20 16 20 16 30 17 30 18 30 19 30
20 30 21 30 22 30 24 30 26 30 26 30
Trade Price with
standard equipment
$ 998.00 1155.00 1320.00 1498.00 1675.00 1820.00
2129.00 2445.00 2748.00 3057.00 3366.00 3570.00
4004.00 4333.00 4932.00 5221.00 5840.00 6458.00
chimney tixe
diam. in.
ht. ft.
ii 20 12 20 13 20 13 20 14 20 15 20
15 20 16 20 16 30 17 30 18 30 19 30
20 30 21 30 22 30 24 30 26 30 26 30
approx. shipping
weight
2741 3141 3527 3923 4335 4728 6049 6835 7620 8503 9292 10139 11334 12616 13809 15036 16690 18316
approx. shipping
weight
2751 3151 3537 3934 4346 4739 6069 6855 7640 8523 9312 10154 11361 12648 13841 15068 16720 18346
Standard equipment includes: (see options, pages 14 and IS)
V-531 diaphragm gas valve with manual opening; 100% shut-off (100% shut-off controls for LP-air and LP gases consists of Baso combination pilot switch and valve with auxiliary Baso pilot valves); manual shut-off valve; gas pressure regulator (except for LP-gas); boiler drains and pilot cocks; insulated jacket; draft hood; transformer.
Water only: Theraltimeter and ASME relief valve for 50 lbs.; CB-655 immersion limit control.
Steam only: Steam gauge; ASME safety valve; 450-BA-l boiler pressure limit control; gauge glass with trimmings; resetting low water cut-off. Controls regularly furnished are for 115 volt, 60 cycle current. Ratings shown are for installations at sea level and at elevations up to 2,000 feet. For eleva tions above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. Room thermostat not included in above prices. For complete information on optional equipment, see pages 14 and 15. For ordering instructions for gas boilers, see page 15.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
P>( 13
HH-3
01628
BOILERS--GAS FIRED
ITtAM AND WATIt
Am e rican -Standard EtYDRONIC HEATING
G-60 OPTIONAL EQUIPMENT
Push button electric ignition: all sizes of G-60 are availabli
with push button electric ignition for use with mfd.. nat and mixed gas non-lOO^c shut-off. and will be furnished when specified on order at the following added charges:
boiler size
added charge
G-606 thru G-6011
$11.85
G-6013 thru G-6021
23.70
G-6022 thru G-6031
35.55
G-6033 thru G-6041
47.40
Pilot filters for G-60 for natural and mixed gases available at no additional charge when specified on order to meet local utility codes.
Room thermostats available at Trade Prices shown on page 32.
McDonnell-Miller Low Water Cut-off No. 67-AR external type can be substituted for the regular No. 69 Low Water Cut-off on G-60 steam gas boilers at no additional charge. If desired, specify on order.
`MS" Equipment: G-60 gas boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. CB-666 im mersion operating control for use in storage tank is required and will be furnished when specified on order at extra Trade Price as shown on page 32. This control operates gas valves on boiler electrically as required. Shipping weights of gas boilers for hot water supply are same as shown for regular gas boilers.
Tri-cock tappings and valves; if desired for steam boiler to meet local code specify on order and add $4.00 to Trade Price of steam boiler.
G-60 available tested at 80 lbs. water working pressure when specified on order. Add S3 00 per section to Trade Price of water boiler.
McDonnell-Miller No. 47*2 and 51*2 Low Water Cut-off and Feider combinations are available with G-60 steam gas boil ers m place of regularly furnished No 69 low water cut-off. when specified on order, at the following added charges to Trade Price of steam boilers with regular equipment:
boiler number
G-606 thru G-6011
G-6013 thru G-6041
combination number
47-2
51 2
added chargee
$33.00
46.00
McDonnell-Miller No. 247-2 and 51-2 low water Cut-off and Feeder combinations for water boilers are available with G-60 water gas boilers when specified on order Add to the Trade Price of the water boiler with regular equipment the current Trade Price for these items shown m the current McDonnellMiller price sheet.
F.M. and F.I.A. equipment: requires EG-0 or EPG-0 electronic control system and special gas control equipment. Available price on application.
V-532 Diaphragm gas valve without manual opening may be substituted for V-531 Gas valve with manual opening at no additional charge. If desired specify on order.
Side Outlet Steam Pop Valves may be substituted at no addi tional charge if specified on order to meet local code require ments.
G-60 external water heater tappings: maximum size all sec tions IV4". Add to Trade Price of boiler $2 00 per section tap ping and $2.00 per jacket tapping.
G-60 Right end steam trim tappings for pressure gauge and water column gauge glass furnished when specified on order at Trade Price additional charge of $10.00 per boiler.
G-60 DUAL GAS BOILERS Natural and Propane Gases
G-60 steam or water boilers are available with dual gas equipment using natural and propane gases. If desired specify on order and add the charge shown below to boiler with standard equipment. Selection of the boiler should be based on the A.G.A. and I=B=R ratings shown on page 12.
boiler number
add to boiler Trade Price
boiler number
add to boiler Trado Price
G-606 G-607 G-608 G-609 G 6010 G-6011 G-6013 G 6015 G-6017
$ 95.00 100.00 105.00 110.00 115.00 120.00 145.00 165.00 185.00
G-6019 G-6021 G-6022 G-6025 G-6028 G-6031 G-6033 G 6037 G-6041
$205.00 225.00 240.00 270.00 300.00 350.00 375.00 445.00 480.00
Dual gas equipment:
In addition to boiler with standard trim, dual gas boilers include:
Two V-532 diaphragm gas valves: two manifolds; gas pres sure regulator (natural gas only); manual shut-off valves;
ribbon burners; 100% safety shut-off (consists of Baso com bination pilot switch and valve with auxiliary Baso pilot valves); pilot cock; outdoor thermostatic adjustable change over control.
Room thermostat not included in above prices.
For ordering instructions for gas boilers, see page 15.
HH3
Page U
01629
AMERiCAN-cStandard
H Y FS R O N I C H E A T 1 ft1 />
BOILERS-GAS FIRED
STUM AND WATt*
G-40 AND G-60 ELECTRONIC CONTROL PANEL SYSTEMS
Panel System EPG-0: Provides electronic supervision of each
mittent elcclnc ignition of all pilots Complete automatic op eration of boiler. 100% safety shut-off Equipment includes: one main control pane! with 1 to 3 auxiliary panels pre-wired and factory assembled. Q-179-A flame rod and electric ig nition pilots, ignition transformer; V-495-B pilot solenoid valves RA-890-E electronic relay for each panel with 8 sec ond response timing and alarm contacts Sec additional charges below
off Available for al! gases Electronic supervision of a pn-
(T.I.M any
bup^iuitun ot ail auxiliary
pilots Mair.-cpTTor ana pilot burner gas supply turned off on
pilot fj'lurf Cont'nucus flame pilot operation Equipment
includes ore tr,;n control panel and for certain boiler sizes
one auxiharv panel factory wired and assembled to main
panel, Q-179-B rlamn rod primarv pilot <si with special
adapter for thermocouple Baso auxiliary pilot burners; Baso
817-F-ll pilot valves with tRcrnocouples. RA-890-E elec
tronic relay for each panel with d second response timing
and alarm contacts See additional charges below
Panel System EPG-1: Provides manual ignition, non-100%-
shut-off Available for Natural. Mixed and Manufactured Gas only Electronic supervision of a primary pilot and thermo couple supervision of all auxiliary pilots. Mam burner gas supply onlv turned off on pilot failure. Continuous flame pilot operation Equipment includes- one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel. Q-179-B flame rod primary piloUs*. Baso auxiliary pilot burners: Baso 850-1 switches with ther mocouples; RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts See additional charges below
Panel System EPG-2: Provides manual ignition. 100r; shut
Panel System EPG-3: Provides intermittent electric ignition
on a primary pilot and continuous flame auxiliary pilots with 100% shut-off Available for all gases Electronic supervision of a primary pilot and thermocouple supervision of auxiliary pilots Mam burner and pilot burner gas supply shut-off on pilot failure. Equipment includes- one main control panel and for certain boiler sizes one auxiliary panel factory wired and assembled to main panel, Q-179-A flame rod and electric ignition primary pilot's), primary pilot solenoid valves' V-495-B; Baso auxiliary pilot burner; Baso 817-F-ll pilot valves with thermocouples; 6000 volt secondary ignition trans former^); RA-890-E electronic relay for each panel with 8 second response timing and alarm contacts See additional charges below.
ADDITIONAL CHARGES--Trade Price
Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment
Panel System EPG-0
boiler number
added charge
Panel System EPG-1
boiler number
added charge
Panel System EPG-2
boiler number
added charge
Panel System EPG-3
botler number
added charge
G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G-6013 thru 6021 G-6022 thru 6031 G 6033 thru 6041
$163.00 177 00 177 00 359.00 538 00 718 00
G- 403 thru 4010 $150.00
G- 606 thru 6037 150.00
G-6041
281.00
Mfd gas only
G 6028 thru 6037 $281.00
G- 403 thru 4010 $171.00
G- 606 thru 6037 171.00
G-6041
283 00
Mfd. gas only:
G-6028 thru 6037 $283 00
G- 403 thru 4010 $185 00
G- 606 thru 6037 185 00
G-6041
334 00
Mfd. gas only:
G-6028 thru 6037 $334.00
Panel System EPG-1 available for Natural. Mixed and Manufactured gases only Balance for all gases.
G-40 AND G-60 ELECTRONIC CONTROL SYSTEMS (less Panels)
The following systems <EG-0. EG-1. EG-2 and EG-3) are also available. but do not include factory wired and assembled control panel These systems provide the same function and
are equipped with thesame basic parts 'less panel) as described for EPG-0. EPG-1.EPG-2. and EPG-3
System EG-0: (Same function as EPG-0 less panel ) See additional charges below System EG-1: (Same function as EPG-1 less panel.) See additional charges below. System EG-2: (Same function as EPG-2 less panel.) See additional charges below System EG-3: (Same function as EPG-3 less panel ) See additional charges below
ADDITIONAL CHARGE$-Trade Price
Specify on order type of system desired, as described above, and add charge listed for boiler size involved to Trade Price of G-40 or G-60 boiler with regular equipment
Control System EG-0
boiler number
added charge
G- 403 thru 407 G- 408 thru 4010 G- 606 thru 6011 G 6013 thru 6021 G 6022 thru 6031 G-6033 thru 6041
$108.00 140.00 140.00 280.00 420.00 560.00
Control System EG-1
better number
added charge
G- 403 thru 4010 $ 86.00
G- 606 thru 6037
86.00
G 6041
173.00
Mfd. gas only:
G 6028 thru 6037 $173.00
Control System EG-2
boiler number
added charge
G- 403 thru 4010 $ 96.00
G- 606 thru 6037
96.00
G-6041
175.00
Mfd. gas only:
G 6028 thru 6037 $175.00
Control System EG-3
boiler number
added charge
G- 403 thru 4010 $113.00
G- 606 thru 6037 113 00
G-6041
227 00
Mfd. gas only:
G 6028 thru 6037 $227 00
Control System EG-1 available for Natural, Mixed and Manufactured gases only. Balance for all gases.
Ignition Cable: Trade Price per foot ....
Flame rod wire: Trade Price per foot . .
................................................
$0.70 $0.40
Orders must specify:
GAS BOILERS--Instructions for Ordering
tl> Complete Boiler Number < 2 < Steam or water. <3) Equipment desired: Regular. "DW" or TS". etc (4) Type of gas <If LP-gas. whether butane or propane)
51 Btu (heat value of gas) and specific gravity '6> Elevation at point of installation if in excess of 2 000
feet. 17 * Pressure available at outlet of gas meter.
Page 15
HH 3
01630
PACKAGED BOILER-BURNER UNITS
WATIt
Am e rican-^tan d ard
H YDRONIC HEATING
"APR" PACKAGED BOILER-BURNER UNITS
Designed and equipped with controls for continuous forced circulation. Factory assembled with jacket and crated. Built-in air-separator in top section.
WATER ONLY
packaged unit
number
APR-72 APR-90
grots laflsR
output Mbh
e
IssBsR burner capacity
gph
72 0.70 90 0.90
nat IsBsR rating
Mbh
54.0 67.5
not rating sq ft water
360 450
Trado Price with standard equipment
$315.00
340.00
chimney size
8x8x 15 8x8x 15
Nozzle sizes, gph, furnished with APR packaged units: APR-72. 0.7S-60*S; APR-90. 0.8S-60*S.
approz. shipping
weight
306 344
Standard equipment all Units: Model DH-5R Arcoflame oil burner with sling mounting and factory installed 956 light sensing flame detector. CB-66815 constant ignition light sensing primary control. Unitized ceramic fiber refractory combustion chamber.
Draft stabilizer.
ASME relief valve. 1" circulator.
Wiring harness and junction box.
Drain valve and theraltimeter CB-580 thermostat and AY-553 limit control.
Motors and controls regularly furnished for 115 volt. 60 cycle current. Note: APR units are shipped with jacket and electrical controls (except thermostat), com bustion chamber, circulator, factory assembled and wired. Arcoflame oil burner shipped separately. Draft stabilizer, relief valve and thermostat are secured inside boiler crate.
Units furnished only as listed above.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-3
Page 16
01631
BOILER-BURNER UNITS OIL FIRED BOILERS
UII
Am e RicAN-<St andard
HYDRONIC HEATING
ARCOLEADER BOILER-BURNER UNITS
Designed and equipped with controls for forced circulation.
Flush jacket. Factory assembled sections "Elimmaire" (cast-in air eliminator in front section).
WATER ONLY
boiierbumcr
unit
number
gross l = B=R
output Mbh
i=b=r burner
capacity
gph
tankless heater
number
A
l=W=H rating
Units less factory installed tankless heater
A1-3-B A1-4-B Al-5 B A1 6 B A1-7-B
100 0.95 136 1.30 173 1.65 208 1.95 244 2.30
Units with factory installed tankless heater
A1-3-BT A1 4 BT A1-5-BT Al-6 BT Al-7 BT
100 0.95 732 3 Vx 136 1.30 732 4`/i 173 1.65 743 5`/2 208 1.95 743 6 244 2.30 743 6
net l=B=R rating
Mbh
75 0 102.0 129 8 156 0 183.0
75.0 102.0 129.8 156.0 183.0
net rating sq ft water
500 680 865 1040 1220
500 680 865 1040 1220
Trade Price with standard equipment
$351.00 420.00 497.00 561.00 637 00
$386.00 455.00 551.00 615.00 691.00
chimney size
8 x 8 x 15 8 x 8 x 15 8x8x15 8x8x15 8x12x15
8x8x 15 8x 8 x 15 8 x 8 x 15 8x8x 15 8 x 12 x 15
approa. shipping
weight
586 726 882 1051 1197
596 740 906 1087 1233
Nozzle sizes, gph. 60* furnished with Arco'eader boiler burner units: A1-3-B. 0.90--H; A1-4B. 1.25-H; A1-5-B. 1 50-S. AI-6-B. 1.7S-S; A1-7-B. 2.00-S.
AGallons of water per minute heated from 4CF to 140F with 200F boiler water temperature.
Standard equipment all Units: (see options, page 19) Model DH-5 Arcoflame oil burner with sling mounting CB-704 constant ignition primary control. Draft stabilizer. ASME relief valve. Theraltimeter. Heat Lib-O-Rator high tempera ture steel combustion chamber
Motors and controls regularly furnished are for 115 volt, 60 cycle current.
Additional standard equipment for units with tankless heaters: Tankless heater as shown above factory installed in section assembly. No 36 Arcoflame control set (CB-520 thermostat, CB-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle.
Additional standard equipment for units less heater: No 34 Arcoflame control set (CB-520 thermostat, CB-851 combination immersion controlhigh limit and circulator control) and nozzle.
Heater opening cover plate.
WATER ONLY
ARCOLEADER OIL FIRED BOILERS
Wet base construction Factory assembled sections. Flush jacket. `'Eliminaire" (cast-m air eliminator in front section)
boiler number
gross l=BsR output
Mbh
l=B=R burner
capacity gph
tankless heater
number
l
=
A W=H
rating
Boiler less factory installed tankless heater
Al-3 A1-4 Al-5 Al-6 Al-7
100 0.95 136 1.30 173 1.65 208 1.95 244 2.30
Boiler with factory installed tankless heater
A1-3-T
A1-4-T A1-5-T Al-6 T A1 7 T
100 0.95 732 3 V. 136 1.30 732 4 >4 173 1.65 743 5>/2 208 1.95 743 6 244 2.30 743 6
net i=B=R rating
Mbh
75 0 102.0 129.8 156.0 183 0
75.0 102.0 129.8 156 0 183 0
net rating q ft watar
500 680 865 1040 1220
500 680 865 1040 1220
Trade Price
$230.00 299.00 376.00 440.00 516.00
$256 00 325.00 421 00 485.00 561.00
chimney size
approa. shipping
weight
8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8x 12x 15
8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x 8 x 15 8 x12 x15
583 730 894 992 1138
593 744 919 1022 1168
AGallons of water per minute heated from 40F to MOF with 200F boiler water temperature.
Standard equipment all boilers: (see options, page 19)
Heat Lib-O-Rator high temperature steel combustion chamber. ASME Relief Valve. Theraltimeter Additional standard equipment boilers with tankless heaters: Tankless healer as listed above factory installed in section assembly. Not: Boilers less factory installs tankli-ss heater are shipped less water heater opening cover unless specified on order
For complete information on boiler ratings, sec page 2 For discount on repairs, see page 2
01632
AMERiCAN-^Standard
HYDRONIC HEATING
PACKAGED BOILER-BURNER UNITS
WATIR
ARCOLEADER PACKAGED BOILER-BURNER UNITS
Designed and equipped with controls for forced circulation.
Factory assembled and crated. Wet base construction. Flush Jacket. "Eliminaire" (cast-in air eliminator in front section).
WATER ONLY
packaiid unit
number
grot* 1=B=R output
Mm
IsSsR humor capacity
gph
tankleaa hoator number
l=W=H
rating
nat IsSsR rating
Mbh
not rating
oq ft water
Trade
Price wtth ctandard equipment
chimney also
approx. shipping weight
Packaged units less tankless heater
A1-3P A1-4-P A1-5-P
100. 0.95 136 1.30 173 1.65
75.0 500 5447.00 8(8x 15 661
102.0 680
516.00 8x8 x 15 811
129.8 865
588.00 8x8x 15 959
Packaged units with factory installed tankless heater
A1-3-PT A1-4PT A1-5-PT
100 0.95 732 3% 136 1.30 732 4Vi 173 1.65 743 5>/z
75.0 102.0 129.8
500 680 865
5478.00 548.00 633.00
Nozzle sizes, gph. 60* furnih*d with Arcoleadar packaged units: A1-3-P, 0.90--H; A1-4P. 1.25-H: A1-5-P. 1.50-S.
Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature.
8x8 x 15 8x8x 15 8x8x15
673 824 991
Standard equipment all Units: (see options, page 19)
Model DH-5 Arcoflame oil burner with sling mounting. CB-706 constant ignition primary control. Draft stabilizer. ASME relief valve. Heat Lib-O-Rator high temperature steel com bustion chamber. iy" circulator with piping. Wiring harness. Drain valve. Theraltimeter. Motors and controls regularly furnished are for 115 volt, 60 cycle current. Additional standard equipment for units with factory installed heater Built-in tankless heater as listed above.
No. 36 Arcoflame control set (CB-520 thermostat, CB-610 combination immersion controlhigh, low limit, circulator control, built-in relay) and nozzle.
Additional standard equipment for units less heater
No 34 Arcoflame control set (CB-520 thermostat, CB-851 combination immersion controlhigh limit and circulator control) and nozzle. Heater opening cover plate.
NotcUnits are shipped with flush jacket and with all electrical controls (except thermostat), circulator and piping, factory installed and wired. Arcoflame oil burner shipped separately. Draft stabilizer, relief valve and thermostat are secured inside boiler crate.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 17
HH-3
01633
: .^r jLXMsaatxm
American-Standard
HYDRONIC HEATING
BOILER-BURNER UNITS OIL FIR5H BOILERS
WATIK
ARCOLEADER OPTIONAL EQUIPMENT
PACKAGED BOILER-BURNER UNITS only: Jacket extension; it desired specify on order and add $28 00 to Trade Price of boiler Jacket extension, shipped in separate carton, provides 15^4" enclosure in front for concealment of oil burner and controls; approximate shipping weight 35 lbs. Two-stage fuel unit will be furnished when specified on order at $5 00 Trade Price extra Add-on No. 36-Z Arcoflame control set will be furnished when specified on order at $20 35 Trade Price extra lAdd-on zone Use only with No. 36 control set > Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30.
BOILER-BURNER UNITS only: Arcoflame control sets other than those included in Trade Price of boiler-burner units will be furnished when specified on order at the following charges:
Control Sot
With Hoator
Water control set No. 13
--
Water control set No. 36
--
Water control set No. 36-Z
$20.35
(Add on zone Use only with No 36 control set.)
Lets Hoator
* $ 9.10
20.35
Boiler burner units less heater can be ordered tor use on gravity systems: Specify No. 13 Arcoflame control set and deduct $S 90 from Trade Price of unit less heater and specify water heater opening cover plate with 3** tapping.
Detailed description of Arcoflame control sets is shown on page 32.
CB-703 intermittent ignition primary control is available at $3.00 Trade Price extra.
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30.
BOILER-BURNER UNITS or OIL FIRED BOILERS: Jacket extension; it desired specify on order and add $28 00 to Trade Price ot boiler. Jacket extension provides 153/" enclosure in front for concealment of oil burner and controls. Approximate shipping weight 35 lbs.
Oil fired boiler heater opening cover plate: furnished only when specified on order at no charge. If specified on order cover plate can be tapped 3" for gravity installations.
BUILT-IN HEATERS: Built-in tankless heaters can be ordered for separate shipment with Boiler-Burner units or Oil Fired Boilers less factory installed tankless heaters at the following Trade Prices:
Heater number
723 732 743
Trade Price
$25.00 27.10 47.70
NOTE: for i--W--H ratings and boilers with which heaters can be used, see table below.
Water mixing valves: for prices, see page 32.
ARCOLEADER |=W=H RATED TANKLESS HEATERS
Heaters tested with boilers.
Built-in tankless heaters for Arcoleader Boiler-Burner units and Oil Boilers can be ordered for separate shipment with units or boilers specified less tankless heaters See Trade Prices above. Select heater desired from table below.
unit or
boiler
size
l=B = R
burner
capacity gph
haatar 723
l=W=H rating
haatar 732
haatar 743
Al-3 0 95 3 Vi 3% Al-4 1.30 3'/ 4 Vi Al-5 1.65 3 Vi 4 Vi Al-6 1.95 3 Vi 41,4 Al-7 2 30 3 Vi 4 Vi
5>/2 6
6
A Gallons of water per minute heated from 40F to 140F with 200F boiler water temperature.
For discount on repairs, see page 2.
Page 19
HH-3
01634
BOILER-BURNER UNITS OIL FIRED BOILERS
ITtAJN AND WATS!
Am e rican and ard HYDRONIC HEATING
ARCOLINER BOILER-BURNER UNITS
Wet base construction. Flush jacket. Factory assembled sections.
Arranged for but less Built-in Tank or Tankless Type Water Heater
boiler-bumer unit numbtr
STEAM
WATER
great
l=8=R output
Mbh
l=8=R burner capacity
nat l=B =R rating
M ft stoam
Mbh
not rating
*q ft water
Trade
Price wttti standard equipment
WIDE BACK TYPE
SO-153-B-T S-0-154-8T S-0155-B-T S-0156-BT
W-0-153-BT W-0-154-B-T W-0-155-B-T W-0-156-B-T
97 1.00 303
72.8 485
132 1.35 413
99.0
660
164 1.60 513 123.0 820
188 1.80 588 141.0 940
$354.00 417.00 492.00 537.00
Nozzle SIMS, iph, 60*. furnished with Arcoliner Boiler-Burner Units ere is follows: No. 153. 0.90--H; No. 154, 1.25-H: No. 155. 1.50-S; No. 156. 1.65-S.
Chimney alia
8 x 8 x 20 8 x 8 x 20 8 x 8 x 25 8 x 8 x 25
approi. shipping weight
851 1010 1163 1394
Standard equipment: (see options, next page)
Model DH-5 Arcoflame oil burner with sling mounting. CB-704 constant ignition primary control. Draft stabilizer. Heat Lib-O-Rator high temperature steel combustion chamber (no deduction for omission). Motors and controls regularly furnished are for 115 volt, 60 cycle current.
Water only: No. 13 Arcoflame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve.
Steam only: No. ll Arcoflame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASME safety valve, gauge glass and trimmings.
ARCOLINER OIL FIRED BOILERS
Wet base construction.
Flush jacket. Factory assembled sections.
Arranged for but less Built-in Tank or Tankless Type Water Heater
boiler number
STEAM
WATER
WIDE BACK TYPE
greet l=8=R
output Mbh
l=8=R burner capacity
___ e*<____
net IsB =R rating
aq ft ateam
Mbh
net rating
eft water
SO-153-T S-0154-T S-0-155-T S-0-156-T
W-0-153-T WO-154T W-0-155-T W-0-156-T
97 1.00 303
72.8 485
132 1.35 413
99.0 660
164 1.60 513 123.0 820
188 1.80 588 141.0 940
Trade Price with tanderd equipment
$228.00 291.00 365.00 410.00
Standard equipment: (see options, next page)
Water. Theraltimeter and ASME relief valve.
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Chimney ixe
8 x 8 x 20 8x8x20 8 x 8 x 25 8 x 8 x 25
approx. shipping
weight
772 930 1083 1234
Jacket extension shown
a For complete Information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-4
Page 20
01635
American-^Standard
hydronic heatinq
BOILER-BURNER UNITS
OIL FIRED BOILERS
ST1AJA ANO WATII
ARCOLINER OPTIONAL EQUIPMENT
BOILER-BURNER UNITS only:
Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges:
Control oot
Added Charge
Steam control setNo.12 .......................... $10.15 Water control setNo. 15............................. 22.75 Water control setNo. 16............................. 24.40 Water control set No. 16Z........................... 53.20 Water control setNo. 26............................. 24.40 Water control setNo. 34............................. 5.90
Detailed description of Arcoflame control sets is shown on page 32.
CB-703 intermittent ignition primary control is available at $3.00 Trade Price extra.
Two-stage fuel unit will be furnished when specified on order at $5 00 Trade Price extra.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
450-BC-l Vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units see page 31 for added charge.
The Heat Lib-O-Rator molded refractory type combustion chamber shown below for Arcoliner Boilers may be specified in place of steel chambers regularly furnished at no charge for No. 153-B-T or 154-B-T. Add to Trade Price for boiler No. 155-B-T $2.85 and for No. 156-B-T $5.75.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Jacket extension; if desired specify on order and add $27 SO to Trade Price of boiler Jacket extension provides 20W" en closure in front for concealment of oil burner and controls. Approximate shipping weight 47 lbs.
Water mixing valves: for prices, see page 32.
For low water cut-off lor use with steam units, see page 32.
Molded refractory combustion chambers: available for Oil Boilers at Trade Prices below when specified on order.
Cover plate for water heater opening will be furnished if specified on order at added Trade Price charge of $4.00.
BUILT-IN HEATERS:
Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Arcoliner Units. For detailed information on ratings, see page 2.
Hooter No.
587 589
596
Hooter Typo
tank tankless
tankless
Hooter Ratings gals. copocJty
85
3 per minute
3Vz per minute
Trodo Prlco
$22.60 29.90
35.00
approx. shipping
walght
23 25
27
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
bollor numbor
153-T) 154-TJ 155-T 156-T
Hoot Ub-O-Rotor modal no.
No. 4 No. 5 No. 6
For discount on repairs, see page 2.
max. firing rate gal. par hour
1.35 1.65 2.00
Troda Prtca
$10.95 14.70 17.60
Page 21
approx. shipping wolght
77 86 90
HH-3
01636
BOILER-fiURNEBrllNITS' OIL FIREDjBOILER*
JUHU)M:erMWW HO
* ------- jiCaCit.
t>o4lr-6umer unit number
STEAM
WATER
(TOM
l=B=R. output
Mbh
l=B=R bumor
capacity *ph
A net 1=8 =R rating
o ft teem
Mbh
net
retinc
BO ft water
Trade ` Price with
standard equipment
Arranged tor but less Built-in Tank or Tankless Type Water Heater
chimney size
approx.
hipping weight
S-84-OB S-85-OB S-86-OB
S-87-OB S-88-OB S-89-OB
W-84-OB W-85-OB W-86-OB
W-87-OB W-88-OB W-89-OB
143 1.40 447 107.3
715 $456.00
175 1.75 547 131.3 875 520.00
202 2.00 631 151.5 1010
577.00
230 2.30 719 172.5 1150 261 2.55 816 195.8 1305 288 2.80 900 216.1 1440
636.00 704.00 760.00
8 x 8 x 20 8 x 8 x 25 8 x 8 x 25
8 x 12 x 30 8 x 12 x 30 8x 12 x35
1338 1479 1603
1746 1863 2007
Nozzle Izet, fph, 60* $. furnished with Oakmont boiler-burner units: No. 84, 1-35; No. 65. 1.65; No. 86. 2.00; No. 87. 2.25; No. 88. 2.50; No. 89. 2.75.
Standard equipment: (fee options, next page)
Model OH-5 Arcoflame oil burner with sling mounting tor rear firing. CB-704 constant ignition primary control. Draft stabilizer.
Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omis sion listed on page 23.
Motors and controls regularly furnished are for 115 volt, 60 cycle current
Steam only: No. 11 Arcoflame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge, ASMS safety valve, gauge glass and trimmings.
Water only: No. 13 Arcoflame control set (CB-520 thermostat CB-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve.
OAKMONT OIL FIRED BOILERS
Flush jacket
Arranged for but less Built-in Tank or Tankless Type Water Heater
boiler number
STEAM
S-84 S-85 S-86
S-87 S-88 S89
WATER
W-84 W-85 W-86
W-87 W-88 W-89
groee
l=B=R
output Mbh
l=B=R bumor capacity
CPh
net 1=1 =R rating
JSn team
Mbh
143 1.40 447 107.3 175 1.75 547 131.3 202 2.00 631 151.5 230 2.30 719 172.5 261 2.55 816 195.8 288 2.80 900 216.1
a net rating
*d
water
715 875 1010
1150 1305 1440
Trade Price with standard equipment
$323.00 386.00 441.00
498.00 566.00 622.00
chimney size
8x8x20 8 x 8 x 25 8 x 8 x 25
8 x 12 x 30 8x 12 x30 8 x 12x35
Standard equipment: (see options, next page)
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water: Theraltimeter and ASME relief valve.
approx. shipping
weight
1109 1245 1352
1485 1602 1746
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH3
Pag* 22
01637
Ame RTc^'^t an dafd
H Y D R O N I C HEAT IN Q
BOlLER.BURNkRtiNrrS OIL firEd boiIers
IT tAJ*'AND'WAT I*
OAKMONT OPTIONAL EQUIPMENT
BOILER-BURNER UNITS only:
Arcoflame control sets other than those included in Trade Price of Boiler-Burner Units will be furnished when speci fied on order at the following added charges:
Centre! Set
Added Ouip
Steam control set Water control set Water control set Water control set Water control set Water control set
No.12............................. $10.15 No.15............................ 22.75 No.16............................ 24.40 No.16-Z......................... 53.20 No.26............................ 24.40 No.34............................ 5.90
Detailed description of Arcoflame control sets is shown on page 32.
CB-703 Intermittent ignition primary control is available at $3.00 Trade Price extra.
Two-stage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam unitssee page 31 for added charge.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Jacket extension; if desired specify on order and add $3325 to Trade Price of boiler. Jacket extension provides 15%' en closure at rear for concealment of oil burner and controls. Approximate shipping weight 51 lbs.
Water mixing valves: for prices, see page 32.
For low water cut-off for use with steam units, see page 32.
Molded refractory combustion chambers; added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omis sion" Prices shown below and will be furnished when specified.
Cover plate for water heater opening will be furnished if specified on order at added Trade Price charge of $4.50.
BUILT-IN HEATERS: Below are the ratings and Trade Prices covering Built-in tank or tankless heaters available for Oakmont units. For detailed information on ratings, see page 2.
Heater No.
598 599 583
585
597
Heater Type
tank tank tankless
tankless
tankless
Heater Ratings gala, capacity
40 100 3 per minute 3 Vi per minute 4Vi Per minute
Trada Prica
$16.00 24.20 38.00
40.50
60.00
approx. shipping
weight
23 27 83
104
92
unit number
84 85 86 871 88> 891
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
Heet Ub-O-Rator model No. Included
No. 00 No. 1 No. 2
No. 3
maximum firing rate gallons per hour
1.50 1.75 2.25
3.00
deduct for omission
$17.85 18.85 20.85
22.85
approx. shipping weight
148 153 170
180
For discount on repairs, see page 2.
Page 23
HH3
01638
BOlUg-BURijEJL UNITS
OILf^RED;OILERS
ITIAMAND.W^IU
HYDRONIC HEAT I N 0
SEVMcK TOILER-BURNER UNITS
Flush jacket.
bollsr-burner
unit number
-- -- - -i
1
STEAM
I
WATCH
| i e>w>> ' i output 1 t.Sbh
NOT TAPPED FOR BUILT-IN TAKH
S I 7 0S S-210B S-25-OB
S-29-OB S-33-OB S-37-OB
W17-OB W-210B W250B
W-29-OB W-33-OB W-37-OB
146 168 188
216 247 278
]* < uiug
| ' rata 1 n>h
, _ Installed radiation ^
q ft atoam
Mbh
aq ft water
WATER H EATER (se a options)
1.5 1.7 1.9
2.2 2.5 2.8
456 525 588
675 772 869
109.5 126.0 141.0
162.0 185.3 208.6
730 840 940
1080 1235 1390
|
I |
_ Trade_
standard equipment
$489.00 529.00 570.00 613.00 677.00 735.00
j | shipping 1 weight
1303 1458 1570 1710 1815 1975
ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER
S-17-OB-T
W-17-OB-T
146
1.5
456 109.5
730 $495.00
S-210B-T
W-21-OBT
168
1.7
525 126.0
840
535.00
S-250BT
W-25-OBT
188
1.9
588 141.0
940
576.00
S-29-08-T
W-29-OB-T
216
2.2
675 162.0 1080
619.00
S-3308-T
W-33-OB-T
247
2.5
772 185.3 1235
683.00
S37-OB-T
W-37-OB-T
278
2.8
869 208.6 1390
741.00
*Nozzle sues, *Ph 60*$. furnished with Severn boiler-burner units: No. 17. 145; No. 21. 1.50; No. 25. 1.75; No. 29. 2.00; No. 33. 2.25; No. 37. 2.50.
1312 1461 1579
1719 1824 1984
Standard equipment: (see options, next page)
Model DH-6 Arcaflaroe oil burner with sling mounting tor front firing. CB-704 constant ignition primary control. Draft stabilizer. Heat Lib-O-Rator refractory combustion chamber: model number and deduction for omis sion listed on page 25. Motors and controls regularly furnished are for 115 volt. 60 cycle current.
Steam only: No. 11 Arcoflame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzle. Steam gauge. ASMS safety valve, gauge glass and trimmings.
Water only: No. 13 Arcoflame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzle. Theraltimeter and ASME relief valve.
SEVERN OIL FIRED BOILERS
Flush jacket.
boiler-number
STEAM
| , WATER
Mrtput Mbh
rate
installed radiation
sqtt steam
Mbh
sq ft water
NOT TAPPED FOR BUILT-IN TANK TYPE WATER HEATER (ee options)
S-17-0 S-21-0 S-25-0
S-29-0 S 33 0 S-37-O
W-17-0 W-21-0 W-25-0
W-29-0 W-33-O W-37-0
146 1.5 456 109.5 730
168
1.7
525
126.0
840
188 1.9 588 141.0 940
216 2.2 675 162.0 1080 247 2.5 772 185.3 1235 278 2.8 869 208.6 1390
ARRANGED FOR BUT LESS BUILT-IN TANK OR TANKLESS TYPE WATER HEATER
S-17-0-T S-21-0-T S-25-O-T
S-29-0-T S-33-0-T S 37-O-T.
W-17-O-T W-21-O-T W-25-0-T
W-29-OT W-33-O T ` W-37C
146 168 188
216 247 278
1.5 1.7 1.9 . 2.2 2.5 2.8
456 525 588 . 675 772 869
109.5 126.0 141.0
162.0 165.3 208.6
730 840 940 1080 1235 1390
Standard equipment: (see options, next page) Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water. Theraltimeter and ASME relief valve.
Trade Price with standard equipment
$355.00 395.00 434.00 477.00 539.00 597.00
$361.00 401.00 440.00 483.00 545.00 603.00
a For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-l
Pag. 24
ppm. shipping wight
1075 1230 1325 1465 1560 1720
1084 1239 1334 1474 1569 1729
01639
--r-r~V-p:
\
AME^ieAN-^tand^rd
HYDROKICHEATINO ---- -*-**--,-------------------- ------- -------
.-v <-
:
SEVERN OPTIONAL EQUIPMENT
BOILER-BURNER-UNITS OIL FIREDj BOILERS
fTIAM AND WATI*
BOILER-BURNER UNITS only:
Arcoflame control sets other than those included In Trade Price of Boiler-Burner Units will be furnished when specified on order at the following added charges:
Control Sat
Added Charge
Steam control set No. 12.............................. $10.15 Water control set No. 15............................. 22.75 Water control set No. 16............................. 24.40 Water control set No. 16-Z........................... 53.20 Water control set No. 26 .............................. 24.40 Water control set No. 34............................. 5.90
Detailed description of Arcoflame control sets is shown on page 32.
CB-703 Intermittent Ignition primary control is available at $3.00 Trade Price extra.
Two-ttage fuel unit will be furnished when specified on order at $5.00 Trade Price extra.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
450-BC-l vapor limit control: If desired in place of 450-BA-l pressure limit control regularly furnished for steam unitssee page 31 for added charge.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Water mixing valves: for prices, see page 32. For low water cut-off for use with steam units, see page 32.
Molded refractory combustion chamber added Trade Prices to Oil Boiler Trade Prices are same as "Deduct for Omission" Prices shown below and will be furnished when specified.
Cover plate for water heater opening will be furnished if specified on order lor "T" type boiler at an added Trade Price charge of $3.T0.
BUILT-IN HEATERS:
If 2>/' right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of unit or boiler.
Below are the ratings and Trade Prices covering Built-in tank or tanlrl> heaters available for Severn units. For detailed information on ratings, see page 2.
Haator No.
703 594 595 590
Haator Typo
tank tank tank tankless
Hoatar Ratings gal*, capacity
66 100 160 3V4 per minute
Trada Plica
$ 9.00 48.00 42.50 36.00
approx. shipping
walgtit
7 54 51 60
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit rmmiar
Haat UMMtator modal No. Ineludod
maximum firing rata gallon* par hour
doduct for ml talon
approx. flipping waifht
17, 21 25. 29 33. 37
No. 1 No. 2 No. 3
1.75 2.25 3.00
$18.85 20.85 22.85
153 170 180
For discount on repairs, see page 2.
Page U
HH3
01640
AA*ERipAN-<$tandard HYDRO NIC. HEAT!?: O
BOIUR-BURNER UNITS
OIL FIRED-BOILERS
STUM AND WATU.'
A-5 OPTIONAL EQUIPMENT
BOILER-BURNER UNITS onlyt
Arcoflame control seta other than thoae Included In Trade Price of boiler-burner unite will be furnished when specified
on order at the following added charges:
Central Set
Added Chaise
Steam control set No. 12.................... $10.15
Water control set No. 34.................... 5.90
Water control set No. 36 ................... 15.05
Water control set No. 36-Z................. 20.35
(Add-on zona. Usa only with No. 36 control sot)
Detailed description of Arcoflame control sets is shown on page 32.
C8-703 intermittent Ignition primary control is available in stead of CB-704 for A-504 thru A-509 at $3.00 Trade Price extra.
Electronic flame safeguard equipment*
62A-70KF ell burner with electronic flame safeguard control Is avail able instead of 62A-70S6 burner for A-507, A-SOt and A-SOS boiler, burner units st added Trado Prlca charge of $93.00. The electronic con trol consist! of C7013A photocall Installed in burner. Q270A safety switch base mounted on burner housing, RA690E safety switch packed with burner delayed oil valve Installed between fuel unit and drawer assembly.
For installations requiring Factory Mutual Approval and in statea and municipalities with regulations more stringent than Underwriters' Lab oratories. Inc., oil burners are available with special electronic flame safeguard controls for A-S boiler-burner units as follows:
62-A-70S6 FFM oil burner for A-507. A-509 and A-509 boiler-burner units, at addtd Trad# Prlca charga of $133.00.
96-7507 oil burner for A-S10 and A-511 boiler-burner units at addtd Trade Price charge of $30.00.
Motors and controls regularly fumishad are for 115 volt. 60 cycle.
450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units-- see page 31 for added charge.
Zone control valve sets may be specified for separate ship ment. For Trade Prices and details, see page 30.
Two-stage fuel unit for DH-5 Arcoflame oil burner will be furnished when specified on order at $5.00 Trade Price extra.
BOILER-BURNER UNITS or
OIL FIRED BOILERS:
Jacket extension; if desired specify on order and add $33.85 to Trade Price of boiler. Jacket extension provides 25' en closure in front for concealment of oil burner and controls. Approximate shipping weight 57 lbf.
Water mixing valves; for prices, see page 32.
For tow water cut-off for use with steam units, see page 32.
Molded n;W.!.y t-.ibustion chambers for A-5 boilers: Trade Prices re sr me ui "Deduct for Omission" Prices shown
below.
If desired, provision for tankless heaters is available at no additional charge. When suffix letter "T** is added on order to unit or boiler numbers, the following number of openings in
center sections will be furnished.
UnK No.
Openings
A-504-T
2
A-505-T thru A-508-T
3
A-509-T thru A-511-T
4
Note: Additional openings can be specified on order.
Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $3.35 each.
NO. 530 TANKLESS HEATER:
No. 530 tankless heater available In single or quantity lot price at $30.65 Trade Price each.
The following table shows the recommended number of heat ers to be used with each boiler and the ratings attained if more than one heater is connected in parallel:
boilar no.
All Sizes All Sizes A-505--A-511 A-508--A-511 A-510--A-511
na. of hastars
1 2 3 4 5
raUng-gpm
4 7 10 13 16
Note: Additions! haatart can ba addtd H tha Matari ara aarving diffarnt systams and It is not llkaly that hsatare will all ba in usa at tha aama tima.
-Gallons of watar par mlnuts raisad from 40 F to 140 F with 200 F boilar watar tamparatura.
Copper pipe manifolds factory assembled for multiple heater parallel hookup shipped in boxes of two manifold assemblies per box when specified with heaters are available at the fol lowing charges:
Manifold astombfy
2 heater 3 heater 4 heater
Trado Prlca par Box
$4.80
6.80 8.80
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit numbor
A-504 A-505 A-506, A-507. A-508 A-509. A-510. A-511
Haat Ub-O-IUtor modal No. Indudod
14-A 15-A 16-A 17-A
maximum firing rata gallon* par hour
2.55 3.30' 5.55 7.65
daduct for omission
$24.85 25.00 33.00 38.00
approx. shipping walght
158 163 180 200
For discount on repairs, see page 2.
Page 27
HH-3
01642
BOILER-BURNER UNITS
OIL FIRED'BOILERS mu AND WATIt
A^ERicAk-^tand^rd K VTRONIC HE?Ar.i:0
A-5 BOILER-BURNER UNITS
bollrvbumr unit number
STEAM | WATER
Flush ticket Tested and equipped for SO lbs. water rrooVing pressure.
grow
IsBsR
output MMi
e
IsBsR
buffnor
capacity
not IsBrR rating
attain
Mbh
ratifiC
watir
Trad* Prica wtth
qulpmtnt
chlmnay alia
appro*. shipping
weight
For Built-In Water Heater Arrangement, see page 27.
A-504-SB A-505-SB A-506-SB
A-507-SB A-508-SB A-509-SB
A-510-SB A-511-SB
A-504-WB A-505-WB A-506-WB
A-507-WB A-508WB A-509-WB
A-510-WB A-511-WB
261 2.55
816 195.8 1305
346 3.30 1082 259.6 1731
426 4.00 1332 319.6 2131
508 4.75 1588 381.1 2541 588 5.55 1838 441.1 2941 668 6.30 2088 501.1 3341
748 7.00 2338 561.1 3741 830 7.65 2594 622.7 4151
$ 700.00 844.00 952.00
1068.00 1153.00 1248.00
1443.00 1528.00
8x 12 x 15 8 x 12 x 20 12 x 12 x 20
12 x 12 x 20 12 x 16x25 12 x 16 x 25
12 x 16 x 25 16 x 16 x 30
1702 1969 2286
2563 2807 3107
3382 3684
Nozzl. il, sph. furnished with A-S units srs as follows: No. A-S04. 1 2.SO 60*S: A-505. 2 1.65 70*S; A-506 2 2.00 70*S: A-507 1 2.25 4 l 2.50 S0*S: A-508 2 2.75 S0*S: A-509, 1 3.00 4 1 3.25 60*$; A-510 2 3.50 80*S; A SU 1 3.50 4 1 4.00 80*S.
Standard equipment: (see options, next page)
DH-S sling mounted oil burner for A-504, with 1-stage fuel unit.
4SW-3606 oil burner for A-505, A-506;
62A-7056 oil burner for A-507, A-508, A-509; 45W-3606 and C2A.-70M, flange mounted, with 2-stage fuel unit.
The above burners are furnished with CB-704 constant ignition primary control. 96-7506 oil burner for A-510, A-511; flange mounted, with 2-stage fuel unit; electronic flame safeguard control consisting of C7013A photocell installed in burner; Q270A safety switch base mounted on burner housing; RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly.
Draft stabilizer. Heat Lib-O-Rator refractory combustion chamber; model number and deduction for omission listed on page 27. Motors and controls regularly furnished are for 115 volt. 60 cycle current.
Steam only: No. 11 Arcoflame control set (CB-520 thermostat. 450-BA-l pressure limit control) and nozzle (s).
Steam gauge. ASME safety valve, gauge glass and trimmings.
Water only: No. 13 Arcoflame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzle (a). Theraltimeter and ASMS relief valve for 50 lbs.
A-5 OIL FIRED BOILERS
Flush jacket. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
IsCfrolsaRs
output
IsBsR
burner capacity
CPU
a*sti=B =R rating
sen
staam
Mbh
nst rating
water
Trada
Met
For Built-in Water Heater Arrangement, see page 27.
A-504-S A-505-S A-506-S
A-507-S A-508S A-509-S
A-510-S A-511S
A-504-W A-505-W A-506-W
A-507-W A-508-W A-509-W
A-510-W A-511-W
261 2.55 346 3.30 426 4.00
816. 1082 1332
195.8 259.6 319.6
1305 1731 2131
$ 560.00 660.00 760.00
508 4.75 1588 381.1 2541 588 5.55 1838 441.1 2941 668 6.30 2088 501.1 3341
860.00 945.00 1030.00
748 7.00 2338 561.1 3741 830 7.65 2594 622.7 4151
1115.00 1200.00
Standard equipment: (see options, next page)
Steam: Steam gauge, ASMS safety valve, gauge glass and trimmings. Water. Theraltimeter and ASME relief* valve for 50 lbs.___________
eFor complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-3
Page 26
chlmnay size
8x 12 x 15 8 x 12 x 20 12 x 12 x 20 12 x 12 x 20 12 x 16 x 25 12 x 16 x 25 12x16x25 16 x 16 x 30
appro*. shipping
weight
1489 1750 2050 2306 2550 2825 3075 3377
01641
BOILER-BURNER UNITS
OIL FIRED BOILERS
fTUM AMD WATII
Am e rican-Standard
HYPBOHIC HEAT IK 01
A-7 BOILER-BURNER UNITS
Jacketed and unjacketed Tested and equipped lor SO IDs. water worKing pressure.
boiler-burner unit number
STEAM
WATER
grots
IsBeR
output Mbh
l=B=R burner
capacity
net 1= B = R rating
sq ft steam
Mbh
net rating
sq ft water
chimney size
unjacketed
jacketed
Trade Price appro t. Trade Price approx. with standard zhlppmg witn standard shipping
equipment weight equipment weight
A-705 SOB A-706-SOB A-7Q7-SO-B
A-708SO-B A-709SO-B A-710-SO-B
A-711-SO-B A-712SOB
A-713S0-B A-714 SO B
A-705-WOB A-706-WO-8 A-707-WO-B
A-708-W0-B A-709-W0-B A-710-WO-B
A-711-WO-B A-712-W0-B
A-713-WO-B A-714-WO-B
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
4331 5061 5981
6944 8020 9075
10125 11118
12112 13105
16 x 16x28 16 x 16x30 16 x 20 x 36
16 x 20 x 42 16x20x45 20 x 20 x 50
20 x 20 x 55 20 x 20 x 60
20 x 24 x 70 20 x 24 x 80
$163300 175300 1928.00
2277.00 2429.00 2607.00
2804.00 2974.00
3297.00 3469.00
4231 4883 5532
6283 6919 7603
8195 8871
9613 [0341
51714.00 1846.00 2033.00
2394.00 2558.00 2748.00
2957.00 3139.00
3474.00 3658.00
4403 5058 5715
6492 7134 7822
8456 9169
9883 10611
Nozzle sizes, sph. 80*S. furnished with A-7 units are as follows: A-70S. 2 4.00; A-706. 1 4.50, 1 5.00; A-707, 2 5 50; A-708 1 4.00. 2 4.50; A-709. 1 4.50. 2 5.00; A-710. 1 5.00. 2 5-50; A-711. 3 6.00; A-712. 3 6.S0; A-713, 2 5.00. 1 11.00; A-714, 2 5.50. 1 12.00.
Standard equipment: (see options/ next page)
96-7508 oil burner for A-705, A-706. A-707; 97-7606 oil burner for A-708, A-709, A-710.
98-7706 oil burner for A-711, A-712; 97A Hi-Lo 7668 for A-713, A-714. All with pedestal mounting; two-stage fuel unit; electronic flame safeguard control consisting of C7013A photocell installed in burner. On model 96-7508 burner, Q270A safety switch base is mounted on burner housing. On models 97-7606. 98-7706 and 97A Hi-Lo 7668, W415B1 panel is furnished with Q270A safety switch base and R408E load relay. On all models, RA890E safety switch is packed with burner; delayed oil valve on models 96. 97 and 98 installed between fuel unit and drawer assembly. 3 delayed oil valves installed on model 97A Hi-Lo.
Draft stabilizer. Steel pedestal base in addition to regular 12" base: 8" height for 5 through 7 section; 10" height for 8 through 14 section.
Steam only:
No. 11 Arcofiame control set (CB-520 thermostat, 450-BA-l pressure limit control) and nozzles.
Steam gauge, ASME safety valve, gauge glass and trimmings.
Water only: No. 13 Arcofiame control set (CB-520 thermostat, CB-655 immersion limit control) and nozzles.
Theraltimeter and ASME relief valve for 50 lbs.
Combustion chamber not furnished. See Installation-Operation and Maintenance Man ual for combustion chambers for A-7 boiler-burner units.
A-7 OIL FIRED BOILERS
Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
grots |=B = R output
Mbh
IsBsR
burner capacity
fph
net 1 = B = R rating
sq ft steam
Mbh
net rating
sq ft water
A-705SO A-706SO A-707-SO
A-708SO A-709 SO A-710-SO
A-711-SO A-712-SO
A-713-SO A-714S0
A-705-WO A-706-WO A-707WO
A-708W0 A-709-WO A-710WO A-711-WO A-712-WO
A-713W0 A-714-WO
866 1012 1196
1376 1570 1760
1956 2148
2340 2532
8.15 9.55 11.25
12.90 14.65 16.30
18.00 19.65
21.45 23.20
2707 3163 3738
4340 5013 5672
6328 6949
7570 8191
649.7 759.2 897.2
1041.6 1203.1 1361.2
1518.6 1667.7
1816.8 1965.8
4331 5061 5981 6944 8020 9075
10125 11118
12112 13105
chimney size
16 x 16x28 16 x 16 x 30 16 x 20 x 36 16 x 20 x 42 16x20x45 20 x 20 x 50 20 x 20 x 55 20 x 20 x 60 20 x 24 x 70 20 x 24 x 80
unjscketed
jacketed
approz.
approz.
Trade Price shipping Trade Price shipping
weight
weight
$1260.00 1380.00 1555.00 1725.00 1877 00 2055.00 2227.00 2397.00 2567.00 2739.00
3882 4518 5149 5720 6330 6990 7556 8208 8912 9616
$1341.00 1473.00 1660.00
1842.00 2006.00 2196.00
2380.00 2562.00 2744.00 2928.00
4054 4693 5332
5929 6545 7209
7817 8506
9182 9886
Standard equipment: (see options, next page)
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water. Theraltimeter and ASME relief valve for 50 lbs.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 28
01643
American-cStandard
HYDRONIC HEATING
BOILER-BURNER UNITS
OIL FIRED BOILERS
ITIAM AND WATIt
A-7 optional equipment
BOILER-BURNER UNITS only:
Electronic flame safeguard equipment: For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories, Inc., oil burners are available with special electronic flame safeguard controls for A-7 boiler-burner units as follows:
96-7509 oil burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00.
97-7607 oil burner for A-708, A-709 and A-710. 98-7707 for A-711 and A-712, and 97A Hi-Lo 7669 for A-713 and A-714 boiler-bumer units at added Trade Price charge of $13.50.
450-BC-l vapor limit control; if desired in place of 450-BA-l pressure limit control regularly furnished for steam units-see page 31 for added charge.
Zone control valve sets may be specified for separate shipment. For Trade Prices and details, see page 30.
Arcoflame control sets: detailed description is shown on page 32.
BOILER-BURNER UNITS or OIL FIRED BOILERS:
Water mixing valves: for prices see page 32.
McDonnell-Miller No. 47-2 and No. 51-2 low water cut-off and feeder combinations: No. 47-2 used with A-705 through A-707 and No. 51-2 used with balance of sizes. Special equalizer tap ping for bottom connection of No. 51-2 located 6 inches below water line on front section. Specify No. 47-2 or No. 51-2 on order and add to Trade Price of steam boilers with standard equipment Trade Price for these items shown in the current McDonnell-Miller price sheet.
For No. 369 low water cut-off for use with steam units, see page 32.
OIL FIRED BOILERS only:
Steel pedestal bases for installation under the regularly furnished 12" base for greater base heights will be furnished when specified on order at the following added charges:
taction tJza
5 through 7 6 through 14
bat*
8" 10"
addad eharffo
$46.00 76.00
Pin 29
01644
HH- 3
OIL BURNERS ZONE CONTROL SETS
Ame rican-$t an dard
HYORONIC HEATING
OIL BURNERS for 115 volt 60 cycle current
For Arcoleader, Arcoliner, Oakmont, Severn, A-5 and A-7 boilerburner units
modal number
gil. par hour
air tube length diem.
mounting
Trade
Price
approK. shipping
waight
including CB-704 constant ignition primary control
DH-5
.65- 3.00 5 4 sling
DH-6
.65- 3.00 6 4 sling
45W-3606 3.00- 4.00 7V, 4>/* flange
62A-7056 4.00- 7.00 10`/ 6>/s flange
62A-7056 4.00- 7.00 10`/s 6% flange
$115.15 115.15 159.00 175.00 180.00
55 55 56 77 82
including electronic flame safeguard control
96-7506
6.00-12.00 ioy 6*/g
96-7508
6.00-12.00 10/s 6>/g
97-7606 10.00-17.00 ioy* 7
98-7706 14.00-20.00 10V4 8
97A Hi-Lo 7668 10.00-24.00 10'/a 7 Vi
flange pedestal pedestal pedestal pedestal
290.00 327.00 476.00 501.00 654.00
107 145 208 208 223
The above prices are for oil burners with primary control as shown. No. 11 steam or No. 13 water basic control set with CB-520 thermostat, and nozzle (s).
62A-7056 burner supplied with 9" dralt stabilizer lor A-507 and A-508. and with 12* dralt stabilizer lor A-509 boilerburner units.
OH-5 burner for Arcoleader, Arcoliner and Oakmont boilerburner units is shipped with pressure ring only. Primary control is shipped installed with Arcoleader Packaged units and is a separate shipping component with Arcoleader, Arco liner and Oakmont boiler-burner units.
DH-5 burner for A-504 boiler-burner unit is shipped with CB-704 primary control and mounting accessories.
DH-6 burner for Severn boiler-burner units is shipped with CB-704 primary control. Accessories for Severn are shipped in a separate box.
45W-3606 burner for A-505 and A-506. and 62A-7056 burner for A-507 through A-509 boiler-burner units are shipped with CB-704 primary control and mounting accessories.
96-7506 burner for A-510 and A-511, and 96-7508 burner for A-705 through A-707 boiler-burner units are shipped with electronic flame safeguard control consisting of C7013A photo cell installed in burner. Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner.
97-7606 burner for A-708 through A-710, 98-7706 burner for A-711 and A-712, 97A Hi-Lo 7668 burner for A-713 and A-714 boiler-burner units are shipped with electronic flame safe guard controls consisting of C7013A photocell installed in burner. W415B1 panel furnished with Q270A safety switch base and R488E load relay; RA890E safety switch packed with burner.
Delayed oil valve on 96, 97 and 98 burners is installed be tween fuel unit and drawer assembly; 3 delayed oil valves installed on 97A Hi-Lo burner.
OPTIONAL ELECTRONIC FLAME SAFEGUARD CON TROL EQUIPMENT: 62A-7056F burner with electronic flame safeguard control is available instead of 62A-7056 burner for A-507, A-508 and A-509 boiler-burner units at added Trade Price charge of $93.00. The electronic control consists of C7013A photocell in stalled in burner, Q270A safety switch base mounted on burner housing. RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly.
For installations requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Laboratories. Inc., oil burners are avail able with special electronic flame safeguard controls for boiler-burner units as follows: 62A-7056FFM burner for A-507, A-508 and A-509 boilerburner units at added Trade Price charge of $133.00. 96-7507 burner for A-510 and A-511, 96-7509 burner for A-705, A-706 and A-707 boiler-burner units at added Trade Price charge of $30.00. 97-7607 burner for A-708, A-709 and A-710, 98-7707 burner for A-711 and A-712, 97A Hi-Lo 7669 burner for A-713 and A-714 boiler-bumer units at added Trade Price charge of $13.50.
Two-stage fuel unit is available for DH oil burners at $5.00 Trade Price extra. Two-stage fuel unit is regularly furnished with 45W, 62A, 96, 97, 97A Hi-Lo and 98 oil burners. Delayed oil valves are standard on all the above burners with electronic controls. V4001A valve is available installed on 45W and 62A burners at $13.00 Trade Price extra.
If CB-703 intermittent ignition primary control is wanted, add $3 00 to Trade Price of boiler-burner unit regularly fur nished with CB-704 or CB-706 control. For optional control sets and added charges, see page 32.
ZONE CONTROL SETS: Using Hydronic Zone Valves
Two-zone and three-zone control sets uUlize one CB-520 thermostat furnished with Packaged G-2 Gas Boilers and Arcoleader Packaged boiler-burner unlta. When these sets are to be used with
other forced hot water installations using circulator, it will be necessary to secure an addiUonal CB-520 thermostat to control the
first zone.
Sat No. 2-Z For Two Zonoo
Sot No. 3-Z For Three Zones
Sat No. 4-Z For Each Zone in Addition to Three Zones
ContanU of Sat No. 2-Z: 1 CB-520 Round Thermostat
2 V8031B V sweat M-H Zone Valves 1 40VA Transformer
Contents of Set No. 3*Z: 2 CB-520 Round Thermostats 3 V8031B sweat M-H Zone Valves 1 40VA Transformer
Contents of Add-on Set No. 4-Z: 1 CB-520 Round Thermostat
1 V8031B sweat M-H Zone Valve 1 40VA Transformer
Trade Price
$45.19
Trade Price
$70-57
Trade Price
$27.45
HH-3
Page 30
01645
AMERicAN-cSlandard
HYDRONIC HEATING
OIL BURNERS
OIL BURNERS for 115 volt 60 cycle current For conversion and replacement
model number
capacity sal.
par hour
air tuba
length
diam.
including CB-704 constant ignition primary control
mounting
(pacify If pedestal or flange ft wanted for OH and 52A burners.)
with control
set
Trade Price
with primary controi and
nozzle(s) only
app- ship, welxht
burner with no2il*(*) only
e with controi
set
DH 8
.65-3.00
8 4 / pedestal 1 $115.15
DH-15
.65-3.00
15
4
) or 1
117.15
DH-23 52A
.65-3.00
23
4]
1
3.00-4.00 7% or 103/ 4`/a ( flange /
118.15 155.00
62-1-7000 4.00-7.00
16%
6% pedestal
170.00
$100 50 102.50 103.50 139.00 154.00
$ 75.00 77.00 78.00
113.50 128.50
60 65 65 65 73
NOTE: Optional air tuba length* are available for 52A burner. Add to Trade Price for 16V" length $3 50; for 22*/" length $5.50.
including electronic flame safeguard control
62-2-7002 5.00- 8.00
96-7501
6 00-12.00
97-7601
10.00-17.00
98-7701
14.00-20.00
97A Hi-Lo 7650 10.00-24.00
16% 16% 16>/t 16%
16%
6%
pedestal
275.00
259.00
6%
pedestal
290.00
274.00
7
pedestal
476.00
460.00
8
pedestal
501.00
485.00
7l/a pedestal
654.00
638.00
_ 83
-- 91 -- 168 -- 168 -- 180
Deduct from shipping weight of burner with control set:
Less control set
3 lbs.
Less control set and less primary control
9 lbs.
The above prices for burners with control set include primary control as shown; No 11 steam. No. 13 or No. 14 water, or No 19 warm air control set with CB-520 thermostat, as speci fied on order.
For optional control sets and added charges, see page 32. For burners shown above with primary control and nozzle(s) only, and with nozzle(s) only, additional controls are available at Trade Prices shown on page 32.
DH-8, DH-15, DH-23, 52A and 621-7000 burners are fur nished with CB-704 constant ignition primary control. On models with electronic flame safeguard controls, C7013A photocell is installed on burner. On 62-2-7002 and 96-7501, Q270A safety switch base is mounted on burner housing. On 97-7601, 98-7701 and 97A Hi-Lo 7650 burners, W415B1 panel is furnished with Q270A safety switch base and R488E load relay; RA890E safety switch is packed with burner. Delayed oil valve on 96, 97 and 98 burners is installed be tween fuel unit and drawer assembly; 3 delayed oil valves installed on 97A Hi-Lo burner.
OPTIONAL ELECTRONIC FLAME SAFEGUARD CON
TROL EQUIPMENT:
52A-4322F burner is available with electronic flame safe guard control consisting of C7013A photocell installed in burner. Q270A safety switch base mounted on burner housing and RA890E safety switch packed with burner; delayed oil valve installed between fuel unit and drawer assembly at $93 00 addition to Trade Price of 52A burner. For installations with firing rates above 4.00 gph requiring Factory Mutual Approval and in states and municipalities with regulations more stringent than Underwriters' Labora tories. Inc., oil burners are available with special electronic flame safeguard controls as follows:
62-2-7003 burner at $30.00 addition to Trade Price of model 62-2-7002. 96-7502 burner at $30 00 addition to Trade Price of model
96-7501. 97-7602, 98-7702 or 97A Hi-Lo 7651 burner at $13.50 addition to respective Trade Price of models 97-7601, 98-7701 or 97A Hi-Lo 7650.
Two-stage fuel unit is available for DH oil burners at $5 00 Trade Price extra. Two-stage fuel unit is standard on 52A, 62, 96, 97, 98, and 97A Hi-Lo oil burners. Delayed oil valves are standard on all the above burners with electronic controls. V4001A oil valve is available installed on 52A and 62-1-7000 burners at $13 00 Trade Price extra. When ordering oil burners be sure to specify nozzle sizes wanted. One nozzle is furnished with DH, two nozzles with 52A, 62, and 96, and three nozzles with 97, 98 and 97A Hi-Lo oil burners. Nozzles and strainers are as follows: For DH: Hollow cone. 60*, 0 65-1 25 gph.
Solid cone, 60*, 1 35-3.00 gph. For 52A, 62, 96, 97, 98, and 97A Hi-Lo:
Solid cone. 70*, 1.50-2.00 gph. Solid cone, 80*, 2.25-6.50 gph. Vapor Installations: Substitute 450-BC-l vapor limit control for 450-BA-l pressure limit control with No. 11 or No. 12 con trol sets and add $10.99 to Trade Price. Electric Clock Thermostat: Substitute T852A for CB-520 ther mostat; specify on order control set number with suffix "B", and add $27 17 to Trade Price. Substitute CB-580 for CB-520 thermostat: Deduct $2 83 from Trade Price with control set shown above.
If CB-703 intermittent ignition primary control is wanted, add $3 00 to Trade Price of oil burner regularly furnished with CB-704 control.
Models DH-8, DH-15 and DH-23 conversion and replacement Oil burners are available with light-sensing constant ignition primary control consisting of factory mounted series 956 flame detector and CB-66815 relay (for jacket mounting only) shipped with burner at same Trade Prices as shown above with control set or with primary control set and nozzle only.
Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters and comply with Commer cial Standard CS-75. Capacities of oil burners using No. 1 or No. 2 fueloil are for
installations at sea level and at elevations up to 1.000 feet. Reduce by 4% for each additional 1.000 feet above sea level.
For discount on repairs, see page Z.
Page 31
HH3
01646
OIL BURNER CONTROL SETS CONTROLS
American-cStandard
HYDRONIC HEATING
control tot
for
control number
eontmti of control ut description
add to Trad# Price of oil burner with
basic eontml set
NO. 11 Steam No. 12 Steam
No. 13 Wttor No. 14 Water No. 15 Water
No. 16 Wator
No. 16-Z Water
No- 19 Warm Air
No. 20 Warm Air
No. 26 Wator
No. 34 Wator No. 36 Wator
No. 36-Z Wator
Boiler without domestic hot water.
Boiler with year-round domestic hot water, built-in heater.
Boiler without domestic hot water, im mersion control.
Boiler without domestic hot water, surface mount control.
Boiler with year-round domestic hot water, storage tank heater, using cir culator.
Boiler with year-round domestic hot water, built-in tankless heater, using circulator.
2-Zone control, for boiler with yearround domestic hot water, built-in tankless heater, using circulators. Note: For each additional zone, add 1 CB-520 thermostat and 1 CB-262 relay transformer at current prices.
Gravity furnace.
Forced warm air unit.
Boiler with year-round domestic hot water, built-in tankless heater, using circulator.
Boiler without domestic hot water, constant circulator operation.
Arcoleader and A-5 units ONLY with year-round domestic hot water, builtin tankless heater, using circulator.
Arcoleader and A-5 units ONLY. (1 No. 36-Z set is required for each zone in addition to the first zone which is controlled by the No. 36 control set.)
CB-520 450-6A-1
CB-520 450-BA-l CB-666
CB-520 CB-655
CB-520 LA409A
CB-520 CB-6S5 CB-666 CB-262
CB-520 CB-655 CB-666-DT CB-262
2 CB-520 CB-655 CB-666 CB-666-R 2 CB-262
CB-520 CB-644
CB-520 CB-840-S
CB-520 CB-655 CB-666-AD
CB-262
CB-520 CB-851
CB-520 CB-610
CB-520 CB-260
thermostat limit control
thermostat limit control 1mm. operating control
thermostat limit control
thermostat limit control
thermostat limit control 1mm. operating control relay transformer
thermostat limit control imm. control double throw switch relay transformer
thermostats limit control 1mm. operating control rev. acting low limit control relay transformers
thermostat limit control
thermostat fan and limit control
thermostat limit control imm. control double throw switch, ad], differential relay transformer
thermostat circulator-limit imm. control
thermostat imm. control relay combination
thermostat zone control relay
$10.15
$22.75
$24.40
$53.20
$ 1.35
$24.40 $ 5.90 $15.05 Add-on zone (Use only with No. 36 set) $20.35
Controls - Regularly furnished are for IIS volt 60 cycle current
number
description
Trade Price
CB-520 C8-S20100 C8 520102
AMERICAN-STANDARO
thermostat. ROUND, low voltage wall plate for CB-520 wall plate for vertical wait box for CB-520
S 7.74 .45 .71
CB-S80 CB-44002
thermostat, low voltage thermostat, line voltage, heating only
4.91 X2.1I
450-8A-1 450-BC 1
pressure limit control. 0-10 lbs. vapor limit controL 0-3*,$ lbs.
11.59 22.58
CB-610 CB-260
CB-262
immersion control relay combination add-on zone control relay (use only with
CB-610) relay transformer
23 48
12.60 12.60
CB-655 CB 655 SE CB-656
CB-656-OT
immersion timit control imm. limit control (for millivolt circuit)
imm. limit control imm. hot water control, double throw switch
8.44 8.44 8.44
10.13
CB 666 C8-666-R CB-666-DT
CB-666 AO
immersion operating control reverse acting low limit control 1mm. hot water control, double throw switch imm. hot water control, double throw switch. adjustable differential
10.13 10.13 11.81
11.81
number
description
CB-66815
CB-703 CB-704
CB-706 CB-840-S CB-844
CB-851 RS-116-F
AMERICAN-STANDARD (continued) light-sensing primary control, constant
primary control, intermittent Ignition primary control, constant ignition
primary control, constant ignition fan and limit control warm air limit control
circulator-limit immersion control immersion control relay combination
Price
$25.80 27.30 25.80 24.83 9.77 8.36 14.36 24.90
T80A
GENERAL CONTROLS thermostat (for millivolt circuit)
521
T86A T832A T852A LA409A
HONEYWELL
thermostat, low voltage thermostat, low voltage, manual turn-down thermostat, electric clock surface mount water limit control
7.80 20.96 34 91
8.03
No. 369 McDonnell fc Miller low water cut-off for automati cally fired steam Arcoliner. Oakmont. Severn, Exbrook, A-S and A-7 boilers and/or boiler-burner units..........................
Trade Price each $16.75
number VD-203
HH-3
Pace 32
Vematherm water mixing valves
description
sirs
adjustable
V4* */i*
Trade Price
$11.48 12.06
01647
American-Standard
HYDRONIC HEATING
INSHOT GAS BURNERS
INSHOT GAS CONVERSION BURNER -- Factory assembled
controls regularly furnished are for IIS volt, 60 cycle current
A.G.A. ratlngs-BUi Input par hour
modal numbor
IN-150
IN-245
IN-275
input*
(min ) max
(min |max
(min (max
Nit snd Mxd. Gii
80.000 150,000
130.000 245.000
130.000 275.000
Mfd. Gii
80,000) 150,000)
not ) available)
not ) available)
Trado Price with standard equipment
Nat and Mxd. Gat
Mfd. Gat
$68.00
$73.25
approx. shipping
weight
20
$74.50 $83.75
not available
not available
21 21
Gas viivc sixas: vh" for IN-150 Nat. and Mxd. Gas, Vi' for alt othar sizes. Sheet metal mounting plate required for all other conversions except Arcoleeder and Arcoliner Wet Base oil boilers. This plate to be furnished by installer.
If CB-520 thermostat not desired, deduct $7.74 from Trade Price shown above.
INSHOT GAS BURNER MAXIMUM INPUTS FOR ARCOIEADER AND ARCOLINER BOILERS
Burner Model: Type of gas:
IN-150 Nat. Mxd. Mfd.
IN-245 Nat. Mxd. only
IN-275 Nat. Mxd. only
IN-275 Nat Mxd. only
Boiler Model
Arcoleader Arcoliner
Maximum Gas Inputs -- Btu/hr.
3 lection
4 *get!on
115.000 120.000
160.000 170,000
5 section
210,000 200,000
6 lection 260,000
6-Section Arcoliner is not recommended for gee firing
Standard equipment includes:
CB-520 thermostat. Runner pilot ignition. Manual shut-off valve. Control housing. Stainless steel flame spreader. Pilot throttling valve. Pilot filter--with mfd. gas burners only. Two main burner orifices: one drilled for minimum input, factory installed; the second, also drilled for minimum input, is provided.
Models IN-150 and IN-245 V-600 series combination gas valve, pressure regulator and safety pilot switch, transformer, manual opener.
Model IN-275 General Controls KX3H quiet solenoid gas valve, plug-in safety pilot switch, transformer, manual opener. Gas pressure regulator.
Optional equipment:
Self-energizing control.i General Controls T80A thermostat, B-60 gas valve and PG9 pilot generator-if desired, specify on order:
Burner Model
IN-150 IN-150 IN-245 IN-275
Nat and Mxd. Mfd.
Nat. and Mxd. Nat. and Mxd.
Trade Charge
No extra cost Add $2.75 Add 2.75
No extra cost
Salad from list below special limit control which mutt bo usad with salf-energlzing controls.
100% safety shut-off, all models, specify on order and add $2.00 to Trade Price above.
Pilot filter-regularly furnished only for Mfd. gas. If desired for Nat. and Mxd. gas, specify on order and add $1.50 to Trade Price above.
Optional controls for self-energizing (millivolt) application:
Number
L-52A30A1A L-39PA412
S45A1A3A3 S45A5AM3
Description
General Controls immersion limit control ............... General Controls pressure boiler limit control, scale
0-10 lbs..................................................................... General Controls warm air limit control................. General Controls fan and limit control....................
For other optional control., *ee page 32.
Trade Price
$10.05
11.44 3.30 6.71
Orders must specify:
GAS CONVERSION BURNERS-lnstructions for Ordering
1- Type of gas. 2. Btu (heat value of gas) and specific gravity. For discount on repairs, see pope 2.
3. Pressure available at outlet of gas meter. 4. Optional controls, if desired.
Page 33
HH-3
01648
STOKER FIREl> BOILERS
ITIAJN ANO WAT
American-Standard
HYDRONIC HEATING
SEVERN STOKER FIRED BOILERS
Flush Jacket
STEAM
j WATER
output Mbh
flrtitg
pounds porheur
not taotaffod rating
q steam
Mbh
*0 ft water
Not adcptetf. re:- ^ .it-in Water Heater (see options below)
SC-17 SC-21 SC-25
SC-29 SC-33 SC-37
WC-17 WC-21 WC-25
WC-29 WC-33 WC-37
146 16 456 109.5 168 18 525 126.0 188 21 588 141.0
730 840 940
216
24
675
162.0
1080
247
27
772
185.3
1235
278
31
869
208.6
1390
.. . Pries
1 annmf
1 shipping WSigtlt
$355.00 395.00 434.00
477.00 539.00 597.00
1053 1220 1301
1457 1534 1687
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings. Water: Theraltimeter and ASME relief valve.
Optional equipment:
Boilers arranged for but less Built-in heaters: If desired, for use with heaters No 590. 594 and 595. add suffix letter "T" to boiler number and add W OO to Trade Price of boiler with standard equipment If 254" right or left side tapping in back section for Built-in heater No. 703 is desired, specify on order and add $2.00 to Trade Price of boiler. Water mixing valves: for prices, see page 32. For low water cut-off for use with steam Severn boilers, see page 32. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at an added Trade Price charge of $3.70. Below are the ratings and Trade Prices for Built-in heaters available for Severn stoker boilers. For detailed information on ratings, see page 2.
Hsatar No.
703 594 595 590
Heater Typo
tank tank tank tankless
Heater Ratings gals, capacity
66 100 160 3y2 per minute
Trad# Pries
$ 9.00 48.00 42.50 36.00
approx. shipping
woight
7 54 51 60
EXBROOK STOKER FIRED BOILERS
STEAM
WATER
gross output
Mbh
l=B=R
capacity ibs/hr
IMtlsS=R rating
sqft steam
Mbh
not rating q ft water
Trad* Pries
approx.
six*
shipping woight
Not adapted for Built-in Water Heater (see options below)
SC-207 SC-208 SC-209
SC-2010 SC-2011 SC-2012 SC-2013
WC-207 WC-208 WC-209
WC-2010 WC-2011 WC-2012 WC-2013
276 30
863 207.1
335 37 1047 251.3
396 43 1238 297.1
452 50 1413 339.1
508 56 1588 381.1
564 62 1763 423.1
620
68
1938
465.1
1380 1675 1980
2261 2541 2821 3101
$604.00 681.00 758.00
835.00 912.00 989.00 1066.00
8x12x25 8x12x25 !2x12x30
12x12x30 12x1.7x35 12x15x40 12x16x40
2150 2313 2628
2821 3134 3309 3641
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve.
Optional equipment:
Boilers arranged for but less Built-In heater If desired add suffix letter "T" to boiler and add W-00 to Trade Price of boiler with standard equipment.
Built-in water heaters are available for use with Exbrook "T" type boilers only. Cover plate for water heater opening will be furnished if specified on order for "T" type boiler at added Trade Price of $425.
For low water cut-off for Exbrook steam boilers, see page 32.
Below are the ratings and Trade Prices for Built-in heaters available for Exbrook "T" type Stoker boilers. For detailed information on ratings, see page 2.
Hoator No.
591 592
For complete information on boiler ratings, see page 2.
Hoator Type
Hoator Ratings gals, capacity
Trado Pries
tank 120 $32.50
tank 200
46.50
For discount on repairs, see page 2.
approx. shipping woight
35 53
HH-3
Pace 34
01649
boiler numsr
STEAM
WATER
3 SC 8 3 SC 9
3WC-8 3 WC 9
AMERiCAN-<Standard
HYDRONIC HEATING
STOKER FIRED BOILERS
STtAM AND WATIt
output Mbh
706 798
NO. 3 REDFLASH STOKER FIRED BOILERS
Jacketed and unjacketed
firing rato pounds par hour
78 88
not Installed rating
sq ft atoam
Mbh
sq ft water
2207 2494
529.6 598.6
3531 3991
un|ackated
Trade Price
approi. shipping
weight
$1130.00 1255.00
3652 4041
jacketed
Trade Price
approx. shipping
weight
$1222.00 1351.00
3827 4224
Standard equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve.
Optional equipment: External water heater tappings available at following added charges: Jacket-$2.00 per tapping. Sections-$2.00 per tapping.
A-7 STOKER FIRED BOILERS
Jacketed and unjacketed. Tested and equipped for 50 lbs. water working pressure.
boiler number
STEAM
WATER
gross IsBsR
output Mbh
l=B=R
burner
capacity Ibs/hr
net 1 = IsR rating
sq ft steam
Mbh
net reting sq ft water
A-705SC A-706SC A-707SC
A-705-WC A 706-WC A-707-WC
866 1012 1196
A-708-SC A-709SC A-710-SC
A-708WC A-709WC A-710WC
1376 1570 1760
A-711SC A-711-WC 1956 A-712SC A-712WC 2148
A-713-SC A-713WC 2340 A-714SC A-714-WC 2532
95 2707 111 3163 131 3738
151 4340 172 5013 194 5672
215 6328 236 6949
257 7570 278 8191
649.7 759.2 897.2
4331 5061 5981
1041.6 1203.1 1361.2
6944 8020 9075
1518.6 10125 1667.7 11118
1816.8 12112 1965.8 13105
chimney size
Trade Price
C
n
eted
approx. shipping weight
lacket id
Trade Price
approx. shipping
weight
16 x 16 * 28 16 x 16x30 16 x 20 x 36
$1260.00 1380.00 1555.00
3882 4518 5149
$1341.00 1473.00 1660.00
4054 4693 5332
16 x 20 x 42 16 x 20 x 45 20 x 20 x 50
1725.00 1877.00 2055.00
5720 6330 6990
1842.00 2006.00 2196.00
5929 6545 7209
20 x 20 x 55 2227.00 7556 2380.00 7817 20 x 20 x 60 2397.00 8208 2562.00 8506
20 x 24 x 70 2567.00 8912 2744.00 9182 20 x 24 x 80 2739.00 9616 2928.00 9886
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings.
Water Theraltimeter and ASME relief valve for 50 lbs.
Optional equipment:
Steel pedestal bases for installation under the regularly fur nished 12" base for greater base heights, will be furnished when specified on order at the following added charges:
section size
5 thru 7
8 thru 14
base heights
8"
10"
added charge
$46.00
76.00
For low water cut-off for A-7 steam boilers, see page 32.
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
Page 35
HH-3
01650
HAND FIRED BOILERS
ITIAM AMO WATtP
STEAM
hollar number
WATER
S-153D S154-D S-155-D
W153-D W154-D W-155-D
American-Standard
hHronic heating
ARCOLINER HAND FIRED BOILERS
Factory assembled sections.
uiy UOOC uuualrucuuu.
Flush jacket. '
grots
output Mbh
tqft attain
not Irntailed rating Mbh
tq ft watar
Trada Pnca
approx. hipping
waight
102 180 43.2 288 $300.00 771
152 272 65.3 435 351.00 928
204
373
89.4
596
403.00
1083
Standard Equipment:
Steam: Steam gauge. ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
Built-in Heaters: If Front Section arranged for but less Built-in screw-in heaters No. 701 or 702 is desired specify on order. Below are the ratings and Trade Prices of Built-in heaters available for Arcoliner.Dry Base steam boilers. For detailed information of ratings, see page 2.
Haator No.
Type
gala, capacity
Trada Prlca
approx. waight
701 tank 60 $8.50 5
702 tank 40
8.00 4
Note: Built-in water heaters are not recommended for hand fired water boilers.
SEVERN HAND FIRED BOILERS
Flush jacket.
hollar numbar
STEAM
WATER
S-17 S-21 S-25
S-29 S-33 S-37
W-17 W-21 W-25
W-29 W-33 W-37
groat
output
Mbh
aqft ataam
not irtstallad rating Mbh
*9 watar
Trada Prfca
approx. shipping waight
194 353 84.7 565 $393.00 1243
244 453 108.7 725
454.00
1413
296 553 132.7 885
519.00
1521
328 630 151.3 1009 364 710 170.5 1137 396 783 187.9 1253
571.00 629.00 678.00
1686 1783 1956
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve. Built-in Heaters: If 214" right or left side tapping in back section for Built-in screw-in heaters No. 701, 702 or 703 is desired specify on order and add $2.00 per tapping to Trade Price of boiler. Below are the ratings and Trade Prices of Built-in heaters available for Severn hand fired steam boilers. For detailed information on ratings, see page 2.
Haatar No.
Haatar Typo
Haatar ratings gala, capacity
Trada Plica
approx. shipping
waight
701 tank 60 $8.50
702 tank 40
800
703
tank
100
9.00
Note Built-in water heaters are not recommended for hand fired water boilers.
5 4 7
For complete information on boiler ratings, see page 2. For discount on repairs, see page 2.
HH-3
Page 3S
01651
STEAM
2 S-6 2 S-7 2-S-8 2-S-9 2-S-10 2-S-ll 2-S-12
Mlr number
WATER
2-W-6 2-W-7 2-W-8 2-W-9 2-W-10 2-W-ll 2-W-12
American -.Standard
HY PRO NIC HEATING
HAND FIRED BOILERS
STIAM ANI WAT!*
NO. 2 REDFLASK HAND FIRED BOILERS
Jacketed and unjacketed.
.. p
greet output
Mbh
K net installed rating
few -
steam
*
Mbh
a ft water
unjacketed
Trade Price
apprex.
hipping weight
390 769 184.7 1231 % 626.00 1966
464 940 225.7 1505
704.00 2293
536 1111 266.7 1778 606 1281 307.5 2050
782.00 860.00
2466 2782
676 1453 348.8 2325
938.00 2999
744 1623 389.5 2597
1016.00 3313
812 1794 430.5 2870
1094.00 3503
U
Jacketed
approx. hipping
weight
$ 690.00 772.00 854.00 936.00
1018.00 1100.00 1182.00
2091 2390 2572 2897
3122 3446 3644
Standard Equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
STEAM
3 S-6 3-S-7 3-S-8 3-S-9
boiler number
WATER
3-W-6 3-W-7 3-W-8 3-W-9
NO. 3 REDFLASH HAND FIRED BOILERS
Jacketed and unjacketed.
greet output
Mbh
696 814 932 1046
net installed rating
sq ft steam
Mbh
sqft water
1503 1799 2100 2400
360.6 431.8 504.1 576.0
2404 2879 3360 3840
unjacketed
Trade Price
approx.
shipping weight
$ 958.00 1102.00 1246.00 1390.00
3243 3698 4110 4549
jacketed
Trade Price
approx. shipping
weight
$1042.00 1190.00 1338.00 1486.00
3397 3870 4285 4732
Standard Equipment:
Steam: Steam gauge. ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water: Theraltimeter, automatic damper regulator, firing tools, and ASME relief valve.
Note: Buckwheat coal grate bars will be furnished at no additional charge when specified on order.
a For complete information on boiler ratings, see page 2.
For discount on repairs, see page 2.
Pag* 37
01652
HAND FIRED BOILERS
ITLUt AMO WATtt
Am e ricAn -<St andafd
HVDRONIC HEATH'
A-7 HAND FIRED BOII *3S
Jacketed and unjacketed. Tested and equipped lor 50 lb3. sr >. o ; lug pressure.
bollar number
STEAM
WATER
groaa
IsBsR output
Mbh
not l=B=R
tqft to am
Mbh
A-705-S A-705-W A-706-S A-706-W A-707-S A-707-W A-708-S A-708-W A-709-S A-709-W A-710-S A-710-W A-711-S A-711-W A-712S A-712-W
1122 1298 1510 1708 1910 2108 2288 2456
2606 3101 3725 4342 5008 5681 6326 6947
625.4 744.3 894.0 1042.1 1202.0 1363.5 1518.2 1667.3
not rating
aq ft wator
chlmnoy aiza
unjadoatad
Trada Prtca
approx.
hipping weight
Fackatad
Trada Prtca
approx. hipping
weight
4169 16x16x40 4962 16 x 20 x 45 5960 20 x 20 x 50 6947 20 x 20 x 55 8013 20 x 20 x 60 9090 20 x 24 x 65 10122 20 x 24 x 70 11115 24 x 24 x 75
$1393.00 4294 $1474.00 4466 1519.00 5006 1612.00 5181 1696.00 5738 1801.00 5921 1877.00 6392 1994.00 6601 2006.00 7199 2135.00 7334 2164.00 7858 2305.00 8077 2336.00 8506 2489.00 8767 2496.00 9231 2661.00 9529
Standard equipment:
Steam: Steam gauge, ASME safety valve, gauge glass and trimmings, automatic damper regulator and firing tools.
Water Theraltimeter and ASMS relief valve for 50 lbs., automatic damper regulator and firing tools.
a For complete information on boiler ratings, see page 2. For discount on repairt, see page 2.
HH*3
Page 38
01653
American-Standard
HYDRONIC HEATING
RADIATORS RADIATOR ACCESSORIES
width
height. Inch#*
q ft per section
Trade Price per sq ft
6 tube 3 tube 4. 5, 6 tube
4, 5 tube 4, 6 tube
32 3.7 $1.25
25 1.6 1.25
25
2.0, 2.4. 3.0
1.18
22
1.8. 2.1
1.23
19
1.6, 2.3
1.25
Arco Radiators are regularly furnished with two and one-half inch <2t4") legs but can be supplied on Special Order with four and one-half inch (4ti") legs, or without legs, at no extra charge.
Arco Radiators sold only in even number of sections up to a maximum of 56 sections.
SUNRAD RADIATORS
yp
sq ft per section
Trade Price per aq ft
M 5x20 M 7`/2 x 23
2.25 3.40
$1.49 1.56
Important: Increase size 5% for recessed installation--
air space
top and sides. Vi* at back. Increase size 15% for tightly recessed in-
stillation-- no clearance top or sides. Vi" air space at back.
Sunrad Radiators are regularly furnished with two and threequarter inch (2 V) legs but can be supplied on special order without legs, at no extra charge.
Sunrad Radiators sold in even number of sections from 4 to 30 sections, and in odd number of sections with center leg from 31 to a maximum of 45 sections.
PEERLESS WALL RADIATORS
*yp
sq ft per section
Trade Price per sq ft
11-B Pattern 8-B Pattern
ii 8
$1.34 1.41
Extra charge of $0.60 each will be made tor tappings at Nos. 20. SO. 60 and 90 as shown on outline drawings of Peerless Wall and Ceiling Radiators in current literature.
Radiators furnished per Figures 840 or 1140 add 52.52 trade extra
Radiators furnished per Figures 842 or 1142 add $5.04 trade extra
For convenience in handling and shipping. Nos. 8-B and 11-B Radiators will be assembled in lengths not exceeding 4 sections.
RADIATOR
Arco Brackets:
Trade
Price
*>ch
For 3. 4, 5. 6 tube, with Wall Plate............................ $0.83
Arco Radiator Pedestals:
Vi' and 1'................................................................ 0.32 Wz" .......................................................................... 0.41
Sunrad Brackets:
For M5 x 20 and M7>/2 x 23.................................. 0.65
Peerless Wall and Ceiling Brackets: Adjustable, with Bearing Plate, single spool........... 4.04 Adjustable, with Bearing Plate,double spool........... 7.34
Type L ...................................................................... 0.23 Type M ...................................................................... 0.16 Type MM .................................................................. 0.23
TypeP ...................................................................... 0.49
ACCESSORIES
Nipples, Plugs, Bushings, etc.:
Trade Price
*ach
1", lVi', l'/2" Plugs. Bushings....................... $0.23
3/4". 1", li/," Slip Nipples........................................ 0.23
1 Vi" Hexagon Nipples.............................................. 0.41
Vi' Air Vent Plugs..................................................... 0.01
Radiator Rod Nuts.................................................... 0 01
Radiator Rods.......................................... per section 0.01
Above items available for use only with our Radiator products.
Sunrad Grilles Inlet--Stamped Lattice Type....................... per section $0.19
Page 39
HH-3
01654
BASEBOARD PANELS
AMERiCAN-^tandard
HYDRO NIC HEATIKC
RADIANTRIM BASEBOARD PANELS
MEMBER
New Model B Steam Rating per lineal foot 2.75 sq ft
SEE CURRENT LITERATURE FOR APPROVED l = B=R STEAM AND HOT WATER RATINGS
per lineal foot
Trad* Price-- $3.M
$1.12
New Model 8 Radiantnm Panel lengths (24 ft to 30 ft) are
made up from the following sections:
1 4 ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
2 ft Double end section
New Model 8 Accessories
phea
Extension Panel and Brackets
(Two 6 ft lengths per box) .............................$8.40
Extension Panel Retaining Bracket........................ 0.22
Extension Panel Cover Strip.................................. 0.53
Assembly Clamp .
7.70
Compression Corner Connection ........................... 2.40
Retaining Block...................................................... 0.15
Adjustable Leg ....................................................... 0.20
Tie Bolt ....... .................................................... 0.06
Theta items are regularly furnished as required with New Model 8 Radiantnm Panels and Accessories. Prices are shown for repair or re placement purposes.
Packed in quantity of 10 per box
price
(Available only in this minimum quantity) per bos of 10
Inverted Corner Cover.............................................. $10.50
Extended Inverted Corner Cover.............................. 17.50
Projecting Corner Cover ........................................ 14.20
Valve Enclosure (all R H. or L.H.) ........................... 12.35
End Box (all R.H. or L.H.) ....................................... 7.00
per lineal foot Trad* Price-- $3.81
per tquare foot $1.12
Model 10 Radiantnm Panel lengths (2*4 ft to 30 ft) are made
up from the following sections:
14 ft Left hand end section
1 ft Right hand end section
2 ft Left hand end section
2 ft Right hand end section
2 ft Center section
Assembly length with legs and tappings at each end:
14 ft Double end section
2 ft Double end section
Model 10 Accessories
T r*de
Price
Extension Panel and Brackets (Two 6 ft lengths per box) .................................. $13.10
Extension Panel Retaining Bracket ...................... 0.22
Extension Panel Cover Strip................................. 0 53
Assembly Clamp...................................................... 7.70 Compression Corner Connection......................... 2.40
Retaining Block...................................................... 0.15
Adjustable Leg....................................................... 0 20
Tie Bolt .................................................................... 0.06
These items are regularly furnished as required with Model 10 Raqtantnm Panels and Accessories. Prices are shown for repair qr re
placement purposes.
Packed in quantity of 10 per box (Available only in this minimum quantity) per box of 10
Inverted Corner Cover.............................................. $13.10 Extended Inverted Corner Cover............................. 23.60 Projecting Corner Cover.......................................... 16.60 Valve Enclosure (all R.H. or L.H.) ........................... 18.35 End Box (all R.H. or L.H.) ....................................... 9.80
Sag No.
0 1 2
EXTRA RADIANTRIM ACCESSORY BAGS
For
Tratfo Prico
Bag No.
For
Double Leg Section 2>y-6' Panel Length 64 *12' Panel Length
t .65 .80 1.80
3 12V4'-18' Panel Length 4 18Vi'-24' Panel Length 5 24V4'-30' Panel Length
Sufficient quantities oT these bags are regularly, furnished with Radiantnm Panels Prices shown are for extra bags as may be required.
Trade Pnee
$2 65 3 50 4 50
SHIPPING WEIGHTS
For estimating purposes only, the following approximate weights per square foot may be used for radiators: Arco. 44 pounds: Sunrad. M5 x 20-6 pounds. M74 x 23-64 pounds; Peerless Wall. 64 pounds; New Model B Radiantnm Panels* 4*4 pounds per souare foot. 12 16 pounds per lineal foot; Model 10 Radiantnm Panels: 4V pounds per square foot. 16.15 pounds per lineal foot.
For estimating purposes only, the following approximate shipping weights may be used for Convectors and Cabinets:
Arco Convectors-elements only-see page 41.
Complete Cabinets, for Arco or Multifin Convectors, per sq ft of cabinet output-14 pounds.
Multifin Convectors-elements only-see page 44.
Multifin Units (convectors shipped mounted in cabinets) per
sq ft of cabinet output-
"Special Service Line"
Types F. R. RC--14 pounds. Type W-14 pounds.
.Type FS
-14 pounds. Type S-14 pounds.
"Stock Moder-1.13 pounds; also see pages 45 and 46.
Heatrim Panels see pages 42 and 43.
MH 3
Page 40
01655
American-Standard
HYDRONIC HEATING
COMVrCTORS
ARCO CONVECTORS
SPECIAL SERVICE LINE when sold in combination with standard cabinets
COMBINATION PRICE:
The actual output in square feet of catalog rating-Steam (215F> obtained with the cabinet heights furnished deter
mines the price of convectors and cabinets sold in combination.
The total price of each order equals the irr.c.ir-. jf catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multipled by the total nurr.cer of units ordered
cabinet type
description
Trad* Price
per eq ft
unit extra charge
F Floor Type-free standing .... $1.35 $17.10
FG Floor Type-free standinginlet grille........................... 1.39
W Wall Hung-flat top............... 1.35
17.10 17.10
FS Free Standing-sloping top ... 1.42
17.95
FSG Free Standing-sloping topmlet grille........................... 1.45
17.95
S Wall Hung-sloping top........ 1.35
17.10
R Recessed-ti" flanged edges
1.34
18.15
RG Recessed-4' flanged edgesinlet grille ....................... 1.38
18.15
Standard Cabinets are furnished in: Prime painted sheet steel--reinforced, No. 18 gauge front and No. 20 gauge back, ends and top. rounded corners, streamline
For illustrations of cabinets, see page 44.
For cabinet extras, see page 47.
cabinet
type
description
Trade Price
per sq ft
unit extra
charge
RGB Recessed-^" flanged edgesinlet grille with bottom overlap .............................. $1.38
$21.30
RC Semi-recessed--24" or 44" flanged edges...................... 1.34
19 75
RCG Semi-recessed-24" or 44" flanged edges-inlet grille
1.38
19.75
RCGB Semi-recessed-24" flanged edges-inlet gnlle-with bottom overlap..................
1.38
22.90
RCGB Semi-recessed-44" flanged edges-inlet gnlle-with bottom overlap..................
1.38
22 90
front discharge grille, and open bottom inlet arch, in heights,
lengths and depths to accommodate convectors listed in current literature
ARCO CONVECTOR -- steam or wafer
ELEMENTS ONLY (when sold less cabinets)
convector length inches
No. 4 31/," depth
approx. unit shipping Trade no. weight Price
No. 6 5s/a" depth
unit no.
approx. shipping
weight
Trade Price
No. 8 7%" depth
approx. unit shipping Trade no. weight Price
No. 10 9`/2" depth
approx. unit shipping Trade no. weight Price
18 418 39 $12.41 618 57 $18.28 818 71 523.02 1018 84 $27 76
23 423 50 16.02 623 73 23.57 823 92 29.79 1023 110 35 88 28 428 61 19.62 628 90 28.90 828 113 36.57 1028 136 44 11
33 433 72 23.25 633 106 34.30 833 134 43.33 1033 162 52 23 38 438 83 26.86 638 123 39.62 838 155 49.99 1038 188 60 47
43 443 94 30.36 643 139 44 92 843 176 56 75 1043 213 68 60 48 448 105 33.95 648 146 50.22 848 197 63.53 1048 238 76 83
53 453 107 37.57 653 172 55.51 853 218 70.30 1053 264 85 06 58 458 128 41.19 658 189 60.82 858 239 77.07 1058 289 93 20
63 463 139 44.79 663 206 66.22 863 260 83.82 1063 314 101 30
Arco Convectors in lengths and depths indicated above are Standardized Sizes when sold with or without cabinets. For sizes not listed above-price on application.
Page 41
MH 3
01656
HEATRIM PANELS
AMERiCAN-tStandard
HYDRONIC HE ATI NO
SEE CURRENT LITERATURE FOR APPROVED I-B-R HOT WATER RATINGS
description
hipappinpgrowxe. ight
COMPLETE UNITS:
Model N85-L-Packaged in 3', 4', S', S', and 8' lengths--completely assembled (package contains element, one-piece back and top section, front panel, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
( per 3 ft. length 1 per 4 ft. length r per 5 ft. length 1 per 6 ft. length 1 per 8 ft. length
per lineal foot
8 10 13 16 22
2%
Model N85HH-Packaged in 3'. 4', S'. 6', and 8' lengths-completely assembled (package contains element, one-piece back and top section, front panel, splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
( per 3 ft. length } per 4 ft. length / per 5 ft. length
per 6 ft. length ( per 8 ft. length
per lineal foot
10 13 16 20 26
3%
HEATING ELEMENTS: Model N50 (H' tube)-Packaged six equal lengths per box.
Model N85 (V," tube)-Packaged six equal lengths per box.
Model N85 (" tube)-Individually packaged one per box.
( per box of six 3' lengths ] per box of six 4' lengths / per box of six 5' lengths 1 per box of six 6' lengths | per box of six S' lengths
per lineal foot
per box of six 3' lengths per box of six 4' lengths per box of six 5' lengths per box of six S' lengths per box of six 8' lengths per lineal foot
per box of one 3' length per box of one 4' length per box of one S' length per box of one 6' length per box of one 8* length per lineal foot
Model N110 (1' tube)-Packaged six equal lengths per box.
per box of six 3' lengths per box of six 4' lengths per box of six 5' lengths * per box of six 6' lengths per box of six 8" lengths
per lineal foot
For comparative and estimating purposes only, HM-3
Page 42
10 13 17 22 28
%
10 13 17 22 28
%
2 3 3 4 5
%
13% 18 22% 27 36
V*
Trad* Me*
$ S.85 7.80 9.75
11.70 15.60
1.95
7.35 9.80 12.25 14.70 19.60 2.45
16.20 21.60 27.00 32.40 43.20
.90
18.00 24.00 30.00 36.00 48.00
1.00
3.21 4.28 5.35 6.42 8.56 1.07
21.60 28.80 36.00 43.20 57.60
1.20
01657
A*iERiCAN-iStand&rd
jH Y D R ON I C< HE AT IN Q
HEATRIM BASEBOARD PANEL ACCESSORIES
VHCA n^UPPC
Model L-Multiple picketed in 3'. 4'. S', S', and 8' lengthsthree equal length! per box (package contain* 3 one-piece back and top section*, 3 front panel*, loose snap-in support bracket*, element slide cradles and 3 seta Joining pieces). Fin ished with white prune coat of paint.
Model L-Individually packaged in 3', 4', S', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion. front panel, loose snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint
Model HH-Multiple packaged in 3`. 4', 5', 6', and 8' lengths-- three equal lengths per box (package contains 3 one-piece back and top sections. 3 front panels, 3 splitter/dampers, loose snap-in support brackets, element slide cradles and 3 sets joining pieces). Finished with white prime coat of paint.
Model HH-Individually packaged in 3', 4', S', 6' and 8' lengths unassembled. (Package contains one-piece back and top sec tion. front panel, splitter/damper, snap-in support brackets, element slide cradles and 1 set joining pieces). Finished with white prime coat of paint.
For comparative and estimating purposes only.
per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8* lengths
per lineal foot
per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 8 ft. length
per lineal foot
per box of three 3' lengths per box of three 4' lengths per box of three 5' lengths per box of three 6' lengths per box of three 8' lengths
per lineal foot
per 3 ft. length per 4 ft. length per 5 ft. length per 6 ft. length per 8 ft. length
per lineal toot
Description
MODEL L ENCLOSURE ACCESSORIES: Inverted Corner Cover--one-piece frontand top section......................packed per box of 10 Inverted Comer Cover-back section only........................................... packed per box of 10 Projecting Comer Cover....................................................................... packed per box of 10
Valve Enclosure-8" wide....................... packed all right hand or all left hand per box of 10 End Cover--4" wide................................. packed all right hand or alt left hand per box of 10 End Cap-114' wide................................. packed all right hand or all left hand per box of 10
Wall End Piece-3 r wide..................................................................... packed per box of 10 One-Foot Filler Pieces-14" wide..........................................................packed per box of 5 Joining Pieces-2" wide.................................................................. packed per box of 20 sets
Note: Finished with white prime coat of paint.
Dampers for Model L Enclosures: Packaged in twelve equal lengths per box.
Not*: Finished with white prime coat of paint.
per box of 3 ft. lengths per box of 4 ft. lengths per box of 5 ft. lengths per box of 6 ft. lengths . per box of 8 ft. lengths
per lineal foot
Replacement parts for Model L enclosures:
Enclosure fronts--8 ft. lengths only.......... Snap-in support bracket with slide cradle.
each each
MODEL HH ENCLOSURE ACCESSORIES:
Inverted Comer Cover-one-piece frontand top section........................... packed per box of10 Inverted Comer Cover-back section only................................................. packed per box of10 Projecting Comer Cover............................................................................. packed per box of10
Valve Enclosure-8' wide....................... packed all right hand or all left hand per box of 10 End Cover-4* wide................................packed all right hand or all left hand per box of 10 End Cap-114' wide................................packed all right hand or all left hand per box of 10
Wall End Piece-3 V" wide........................................................................... packed per box of10 One-Foot Filler Pieces-14" wide............................................................... packed per box of5 Joining Pieces-2" wide.................................................................. packed per box of 20 sets
Note: Finished with white prime coat of paint.
Replacement parts for Model HH Enclosures:
Enclosure fronts-8 ft. lengths only..........................................................................................each Snap-in support bracket with slide cradle.............................................................................each
For comparative and estimating purposes only. NOTE: Add 25% to accessory unit price when ordered in less than quantities indicated above.
Pif* <3
HEATRIM PANEL ACCESSORIES
pom. hipping
wight
19 24 30 35 47
6 8 11 13 16
24 30 38 46 59
2%
8 11 14 16 21
2 Vi
approx. shipping weight
3 4 6 12 10 5 4 9 5
Trttfp Prtc*
$ 7.20 9.60 12.00
14.40 19.20
.80
2.70 3.60 4.50 5.40 7.20
.90
12.06 16.08 20.10 24.12 32.16
1.34
4.35 5.80 7.25 8.70 11.60
1.45
Trade Price
$ 8.00 4.50
10.00 17.50 12.50
5.00 3.00 6.00 5.00
12 3.60 17 4.80 22 6.00 25 7.20 34 9.60 Vi .10
2.00 .35
4 8.00 6 4.50 7 11.50 16 18.00 12 12.50 6 8.00 6 4.00 12 7.75 6 7.00
2.40 .35
HH-3
01658
CONVECTORS
Typ. K (Slock Model) Typo F (Special Service)
qBBBBD
i
Type KC (Stock ModeO
Types
TypeFS
TypeW
Type R
npntmimniB
TypeRC HH-]
American-^Standard
HYORONIC HEATING
MULTIFIN CONVECTORS
w*avK1i.ufi..iiuii_v,ii nr.r.itw. .vi
The actual output in square feet of catalog ratmg-Steam (215'F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog square feet ordered multiplied by the price per square foot, plus the unit extra charge multiplied by the total number of units ordered.
cabinst
*yp
description
Trad* Pries
per SO ft
unit extra
charts
Stock Model
K Floor Type-free standing........................................................ KC Semi-recessed-2Vi" flanged edges.........................................
$0.40 .40
$11.00 14.00
Note: For expanded prices, see papes 45 and 46. For cabinet extras, see page 47. special service
f FG w FS FSG R RG RGB
RC RCG RCGB
RCG8
Floor Type--tree standing-inlet grille................................
Free Standing-sloping top-inlet grille...............................
Recessed-Vi" flanged edges-inlet grille............................. Recessed-Vi" flanged edges--inlet grille with bottom
overlap..................................................................................... Semi-recessed-2Vi" or 4 Vi" flanged edges......................... Semi-recessed-2Vj" or 4Vi" flanged edges inlet grille....... Semi-recessed-2Vi" flanged edges-inlet grille-with botJ
tom overlap.......................................................................... Semi-recessed--4Vi" flanged edges-inlet grille-with bot-
tom overlap..........................................................................
$ 41 .44 .40 43 .46 .37 .47 .50
.50 .47 .50
.50
.50
$12 00 ' 12.00
12 25 13 75 13.75 12 25 13.75 13.75
16.75 14.75 14.75
17.75
17.75
Note: For cabinet extras, see page 47.
Elements only (when sold less cabinets) -- steam or water
csnvsctsr
HttSSt
20 24
28 32 36
40 44 48 56 64
No. 4 -37/," depth
alt
as.
420 424
428 432 436
440 444 448
456 464
tpprsx. ttlippfRf TrsSt wslfflt Pries
8 $ 8.40 20 9.10
12 9.80 14 10.40 16 11.15
18 11.85 20 12.40 22 13.10
26 14.50 30 15.90
No. 6 -57/r depth
Bit SS.
620 624
628 632 636
640 644 648
656 664
ppm. shipp isf Trais wsifltt Pries
13 110.75 16 11.65
19 12.60 22 13.45 25 14.30
28 15.25 31 16.10 34 16.95
40 18.75 46 20.50
No. i-7y," depth
approi.
sslt ibippiftf as. WSlftlt
820 15 824 19
828 23 632 27 836 31
840 35 844 39 848 43
856 51 864 59
Trias Fries
$13.90 15.10
16.35 17.60 18.80
20.05 21.30 22.55
25.00 27.50
No. 10-9'/," depth
ppm. nit tSippiRf Trada as. wiifllt Prtca
1020 21 $19.30
1024 26
20.55
1028 1032 1036
31 36 41
21.85 23.10 24.40
1040 1044 1048
46 51 56
25.60 26.90 28.20
1056 1064
66 76
30.70 33.25
Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel-reinforced. No. 18 gauge front and No. 20 gauge back (K and KC-No. 26 gauge), ends and top rounded corners, streamline front discharge grille, and open bottom inlet arch, in heights, lengths and depths to accommodate con vectors listed in current literature.
ONE-PIPE STEAM: Particular reference must be made on order if special service convectors are to be used on onepipe steam systems. Multifin convectors-for two-pipe steam or water systems--cannot be used, or modified, for one-pipe systems.
Elements arranged with special one-pipe steam headers--$.06 Trade Price per square foot of cabinet output extra.
Page 44
01659
American-Standard
HYDRONIC HEATING
CONVECTORS
MULTIFIN CONVECTORS
n/AP
TTrE
a#
K
-iiwv#f1/t
ftft
mwvu - nut
gm mniavim4 t*ii
Expanded prices
For use on two-pipe steam and hot water systems only.
(ikitMt iMftk hthn
No. 4 depth (4Vi" cabinet)
Mil M.
n MfRVt
HW. WpptH ftiflrt
Tnd*
20' cabinet height
No. 6 depth (6Vi'cabinet; No. 8 depth (8Vi " cabinet) No. 10 depth (10Vi' cabinet)
Mil M.
n ft
WfMflttppiM
MtVt Vftlfllt
Trv4* frill
Mil ft.
n ft *<npi
Mm. shippiaf
Vtlfllf
TnH Rri
nil M.
H ft
tkipp'M viifkl
Trde fnii
20'/, 420-20 11.3 18 $15.52 620-20 16.3 21 $17.52
24 Vi 28 Vi
424--20
13.9
20
16.56
....
624-20 20.1
629-20 23.8
24 27
19.04 20.52
32 Vi
632-20 27.6 29
22.04 832-20 33.6 33 $24.44
36*4
639-20 31.3 33
23.52 836-20 38.1 37
26.24 1036-20 42.4 42 $27.96
40 %
640-20 35.1 34
25-04 840-20 42.7 39
28.08 1040-20 47 6 48
30.04
44*4
644-20 38.8 37
26.52
48*4 56*4 64*4
648-20 656-20 664-20
42.6 50.1 57.6
40 45 52
28.04 848-20 31.04 856-20 34.04 864-20
51.8 60.9 70.0
46 51 59
31.72 1048-20 35.36 1056-20 39.00 1064-20
57 8
68 0
70.2
52 58 64
34.12 38.20 42.28
24' cabinet height
20*/,
24 Vi 28*/, 32Vi 36*4 40*4 44*4 48*4 56*4 64*4
420-24 424-24 428-24
13.1 16.1 19.1
20 22
25
16.24 17.44 18.64
620-24 18.4 624-24 22.7 628-24 26.9 632-24 31.1 636-24 35.4 640-24 39.6 644-24 43.8 648-24 48.1 656-24 56.5 664-24 65.0
23 26 30 33 35 38 42 44 50 57
18.36 20.08 21.76 23.44 832-24 25.16 836-24 26.84 840-24 28.52 30.24 848-24 33.60 856-24 37.00 864-24
37.9 43.0 48.2
58.4 68.7 78.9
38 40 44
50 55 63
26.16 28.20 1036-24 30.28 1040-24
48.6 54 4
45 52
34.36 1048-24 38.48 1056-24 42.56 1064-24
66.1
77.8 89 5
62 64 71
30 44 32.76
37.44 42.12 46.80
32" cabinet height
20%
34 Vi 28 Vi 32'/, 3V4 40 Vi 44 Vi 48 Vi 36 Vi 64 Vi
620-32 19.7 624-32 24.2 628-32 28.7 632-32 33.3 636-32 37.8 640-32 42.3 644-32 46.8 648-32 51.3 656-32 60.4 664-32 69.4
29 32 36 40 43 48 56 58 67 71
18.86
20.66
22.48 24.32 832-32 26.12 836-32 27.92 840-32 29.72 31.52 848-32 35.16 856-32 38.76 664-32
41.2 46.8 52.3
63.5 74.6 85.8
45 46 56
65 73 76
27.48 29.72 1036-32 31.92 1040-32
53.1 59.5
54 59
36.40 1048-32 40.64 1056-32 45.32 1064-32
72.3 85.1 97.9
69 76 84
32.24 34 80
39.92 45.04 50.16
Plugs and bushings are not regularly furnished with Multifln Convectors, but are available for separate sale at prices shown
on page 39.
Special air vent assemblies, Trade Price.................each $1.80
Metal trim strips, Trade Price................................... eac^ *2-75
Damper, chain type-standard length. Trade Price, each 2.10
Snap-On inlet grille. Trade Price..................................... 2
Page 45
HH-3
01660
CONVECTORS
American-Standard
HYDRONIC HEATING
rnnwiw"
cabinot tinitti inch**
20 Vi 24 Vi 28Vi 32 Vi 36 Vi 40 Vi 44 Vi 48 Vi 56 Vi 64 Vi
MULTIFIN CONVECTORS
TYPE KC - STOCK MODEL - PARTIALLY RECESSED Expanded prices For use on two-pipe steam and hot water systems only.
No. 6 depth (6V4" cabinet) with 2Vi" flange
unit no.
sqft
output
approx. shipping
walght
CABINET HEIGHT
*O
CM
620-20 624-20 628-20 632-20 636-20 640-20 644-20 648-20 656-20 664-20
16.3 20.1 23.8 27.6 31.3 35.1 38.8 42.6 50.1 57.6
26 28 30 33 35 39 40 43 54 59
Trada Met
$20.52 22.04 23.52 25.04 26.52 28.04 29.52 31.04 34.04 37.04
cabin#t lanffth Inchas
20 Vi 24 Vi 28Vi 32Vi 36 Vi 40 Vi 44Vi 48Vi 56 Vi 54 Vi
No. 6 depth (6V4" cabinet) with 2Vi" flange
unit no.
4 ft output
approx. hipping woigM
24" CABINET HEIGHT
620-24 624-24 628-24 632-24 636-24 640-24 644-24 648-24 656-24 664-24
18.4 22.7 26.9 31.1 35.4 39.6 43.8 48.1 56.5 65.0
28 33 37 38 39 41 44 55 58 68
Trada Prtca
$21.36 23.08 24.76 26.44 28.16 29.84 31.52 33.24 36.60 40.00
Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39. Special air vent assemblies. Trade Price......................................................................... each 91.80 Damper, chain type--standard length, Trade Price.......................................................each 2.10 Snap-On inlet grille, Trade Price .................................................................................... each 2.75
HH-3
Page 46
01661
American-Standard
HYORONIC HEATINQ
CABINET EXTRAS FOR MULTIFIN AND ARCO CONVECTORS
CONVECTORS
CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY
1. Chain type dampen .....................................................................................each 2. Metal trim strip* (type K only) .................................................................. each 3. Snap-on inlet grilles......................................................................................each 4. Special air vent assemblies........................................................................... each
Trade Pried
$2.10 2.75 2.75 1.80
SPECIAL SERVICE CABINET EXTRAS-MULTIFIN AND ARCO CONVECTORS
1. Chain type dampen......................................................................................each 2. Knob type dampen....................................................................................... each 3. Marking or tagging-roomnumber or location............................................ each
4. Access doon-lilt-otl type ...................................................................... each 5. Access doon-piano hinge type ................................................................. each 6. Stool outlet-regular sheet price, plus................................................................
7. Extra length-per inch or fraction thereof......................................................... 8. Rotary cam locks......................................................................................... each 9. Screws other than standard slotted type--per convector.................................
10. Grille reinforcing angles-6' centen--per grille......................... 11. Heavier gauge cabinets-trade price per iq ft of cabinet output:
2.10 2.90
.20
2.50 2.90 1.40
.60 .70 .30
1.00
(rents only
No. 18 gauge ......................................................................... No. 16 gauge .........................................................................
$ . .. .04
No. 14 gauge .........................................................................
.09
12. Insulation--trade price per sq ft of cabinet output:
back only
Aerocor-1" thick compressible to t4"............................... $0.12
Wood Fiberboard-t4" thick................................................ Asbestos Millboard-Vi" thick............................................
.12 .12
Asbestos Millboard-Vi* thick............................................
.18
13. Front panels only: 50% of complete convector unit price (based on No. 6 depth)
14. Cabinet only: 70% of complete convector unit price
15. Providing round pipe holes or knockouts................................... 16. Providing special shape cutouts...................................................
liners only
$0.04 .06 .10
back, ends, and tap
$0.18 .24 .24 .36
price on application price on application
NOTES APPLICABLE TO MULTIFIN CONVECTORS ONLY:
Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale at prices shown on page 39.
MINIMUM CABINET HEIGHTS WITH DAMPERS
Multifin Convectors: Types FS, FSG
Chain Typa Dampers
18" for #4 Depth 20" for #6 Depth 24" for #8 8c #10 Depths
Knob Type Dampers
18" for #4 Depth 20" for #6 Depth 24'tor #8 6 #10 Depths
Type S Arco Convectors:
Types F, FG, W
14' for #4 It #6 Depths 18' for #8 (c #10 Depths
20' For All Depths
14' for #4 It #6 Depths 18' for #8 6 #10 Depths
20" For All Depths
Types FS, FSG
24' for #4.#6 & #8 Depths 26' for ff 10 Depth
24' for #4.#6 6 #8 Depths 26'for #10 Depth
Type S
18" for #4 Depth 20" for #6 Depth 26* for #8 6 # 10 Depths
18' lor #4 Depth 20" for #6 Depth 26" for #8 6 #10 Depths
Types R, RG, RGB, RC, RCG. RCGB
24" For All Depths
20* For All Depths
NOTE: Minimum heights lor Arco Convectors applicable to X-4 (underneath) connection only.
Page 47
01662
HH-3
r- . -
: > . '**'5.
HRMS
'
AMERicAN-^tandard HYDRO NIC HEATING
TRADE PRICE BOOICs..r,,
Illustrations and descriptions of Plate Nnmh.r* listed != thie price beet Trill tc
in u,e current American-
SUndard Heatlnf-Coollnf Products Catalog and literature. Items Illustrated In product literature and not Included
In this price book are discontinued. The illustrations In this price book although actual representations of certain product
In the line, do not necessarily show sizes and details of all products in the line.
This book contains suggested Trade Prices for certain Hydronlc Heating products sold by American Radiator & Standard Sanitary Corporation ("American-Standard") through Its Plumbing and Heating Division. (AmericanStandard acting through that Division is hereinafter referred to as the "Seller"). The Seller assumes no obligation to sell to anyone at any price any of the items listed herein.
All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein.
INVOICE MINIMUM An order for Items for which invoice prices aggregate less than $1.00 will be billed at $1.00.
TERMS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH ITS PLUMBING AND HEATING DIVISION
All sales of goods by American-Standard through its Plumbing and Heating Division are made subject to terms and conditions printed below, in Its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions are as follows:
met
Goods told by the Seller will be billed to the Buyer! according to the price* end term* contained in Its current bulletins end price books. In the cese of orders for foods for which no price Is currently in effect, the price will be determined by the Seller end eet forth In the Invoice issued efter shipment of the foods.
Taxes. Any tsx or other Government chsrfe now or hereefter levied upon the production, sole, use or shipment of foods ordered or sold, will be chsrftd to and psld for by the Buyer.
OIUVIRY
Traeipertatlee Risks. Delivery to the initial carrier shell constitute de livery to the Buyer The Seller's responsibility ceeses upon delivery In food order to such earner, end ell foods sre shipped at the Buyer's risk.
The Buyer Is urfed to examine ell dettvenes carefully before slgntng transportation receipts If foods are visibly damsfed. the Buyer should Insist that written confirmation of the damafe be noted on the frelfht bill or dray ticket by the afent of the carrier. If damafe Is discovered after unpacking the earner should be notified at once, so that Inspection can be made and the claimed damafe substantiated by the earner.
Interference with Delivery. The Seller has no obligation to deliver goods against any order until it has accepted the order by Issuance of Its ac knowledgment of order In any event, the Seller will not be liable for any delay or failure in the delivery or shipment of foods against an accepted order or for any damages suffered by reason thereof, when such delay or failure is. directly or indirectly, due to accident (In manufacture or other wise). fire, flood, not. war. embargo, tabor stoppages. Inadequate trans portation facilities, shortage of material or supplies, delay or default on the part of its vendor*, regulation by Government authortty, or any like or dissimilar cause or causes beyond its control.
WARRANTY
Except where s different express written warranty has been Issued with respect to particular products, no warranty, express or implied, is extended by the Seller to any person or persons other than its distributors snd other direct Buyer* To direct Buyers, the Seller warrants only that It will furnish by freight a replacement for. or at Its option lepalr. any product of its manufacture or part or portion thereof, proved to Its satis faction to be defective in material or workmanship under normal use and service within one year after installation. The Seller will not be respon sible for any damages whatsoever, or for labor expense, in connection with the replacement of defective products or parts or portions thereof
This warranty is In lieu of all other warranties, express or Implied, and of all othe^ obligations or liabilities, on the part of the Seller The Seller neither assumes nor authorizes any other person to assume for it any other liabilities in connection with the sale of Its products except In the case of express wsrranties which may be Issued by It In writing from time to time with respect to particular products.
Goods of other manufacturers sold by the Seller are not warranted except by express warranties which may be Issued In writing from time to time, with respect to particular products or particular sales, but the Seller will endeavor to secure for Its direct Buyers the benefits of war ranties extended by the manufacturers of such goods sold but not manu factured by the Seller.
CONTIACT with tuna
Aeceptaaee ef Orders. Order* will be accepted only by the Seller'* usual acknowledgment of order containing terms and conditions applicable thereto. No terms and conditions appearing In a Buyer s order that are at variance with the Seller's terms and conditions shall be binding upon the Seller unless specifically agreed to by it In writing. Unless the Seller spe cifically so agrees In writing In acknowledging any order, any terms and conditions appearing in a Buyer's order contrary to those stated herein and In such acknowledgment of order are to be deemed waived by the Buyer. Receipt by the Buyer of the acknowledgment of order without prompt objection to the terms and conditions therein and herein set forth, constitutes acceptance by the Buyer of such terms and conditions.
Cancellation ef Order*. After the Seller's acknowledgment of order ha* been issued, an order may be modified or cancelled only upon written agreement by the Seller. Orders for goods other than those of standard manufacture will not be cancelled after a commitment has been made or production scheduled.
Credit for Returned Geodi. Merchandise may not be returned for credit unleas the Seller has agreed to accept It. Where returns sre accepted, a deduction of 10% will be made for rehandling. All transportation costs for returned goods must be paid by the Buyer. In any event, only salable merchandise of standard manufacture may be returned for credit.
Credit Approval. Buyer*' orders are accepted subject to credit Investiga tion and approval, and delivery may be withheld or shipment stopped In transit on accepted order* without any liability on the Seller's part. tf. In its opinion, the Buyer s ability to pay for the merchandise on these term* and conditions is in doubt.
SHORTAGCS OR VARIANCCS
No claims for variances from or shortages in order* will be considered unleu presented within CO days after receipt of goods.
PRODUCT ANO PACKAGING CHAMOIS
Faetors beyond the control of the Seller and the need for continuing improvement of product require the making of changes from time to urae in products and their packaging. The right Is reserved to makeressonaoie changes of any kind without notice and to deliver revised designs or moqels of goods against any order, unless on the face of the acknowieagmew* of order this right is specifically waived.
The Seller ih.ll hive no reiponUblllty whitever with nitcl t chin made by the manufacturer in product# (or their packaging) aold out om manufactured by the Seller.
SHIPPING WIIOHTS The shipping weights given herein are approximate.' lot f . venlcnce only, and are not guaranteed.
AMERICAN RADIATOR & STANDARD SANITARY CORPORATION
PLUMBING AND HEATING DIVISION
Page 41
01663
*