MATERIAL SAFETY DATA SHEET
CORPORATE RESEARCH & DEVELOPMENT
SCHENECTADY, N. Y. 12305
Phone: (518) 385-4085
DIAL COMM 8*235-4085
SECTION I. MATERIAL IDENTIFICATION
MATERIAL NAME: AR0CL0R 1254
'
DESCRIPTION: Distillation cut of polychlorinated biphenyl (or diphe
eimrt
OTHER DESIGNATIONS: PCB,. an Askarel, PYRANOL., GE Material A13B1, C,"
27 323 188:
MANU__F_A_C__T_U_R__E_R_: _M__a__t_e_r_i_a_l w__a_s a_ pr_r_o_d__u_c_t of M___o_n_s__a_n_t_o C. o..,, b__u_t d_ rop..pe. d_i_n_"_"_T_9_T__7_7' Except uses specifically exempted and regulated by EPA (for example power transformers),
legal manufacture, distribution in commerce, and use of PCB's in USA ended in 1979
under- TSCA.
, .
SECTION II. INGREDIENTS AND HAZARDS
HAZARD.DATA
Mixture of Chlorinated Biphenyls, ^12^10-x^lx:
x Approx. %
2
0.5
3
1
4
21
5
48
6
23
7
6
Includes 69 or more compounds with
average of 4.98 Cl atom/molecule.
MI.JJ
||_-
chlorinated dibenzofurans.
ca 100
EPA exemption or authorization needei for any measurable exposure* ,
Rat, Oral LD50 Adult 4-10 g/kg Weaning 1.2g/kg
Rat, Intravenous
LD50 358 mg/kg
*Current ACGIHH 8o-hr TWA is 0.5 mg/m3. NI0SH has proposed z
10-hr TWA of 1.0 yg/m3. Materials with over* 50* ppm PClB
content are regulated for handling, storage, records,
and waste disposal- EPA criterion in navigable waters
is 0.00T |iS7Lf. PCFr
&
^
Rat, Oral, TDLo 1220 mg/kg/35 wk (neoplastic effect)
SECTION III. PHYSICAL DATA
Boiling range at 1 atm, deg C ------Vapor pressure at 150 C, mm Hg -----
[ ca 360-39
<1
Specific gravity (65/15.5 C) -- our point, deg Q ------------------------
1.5 10
Water solubility at 25 C, ppm ------- ca 0.01
Molecular weight (Av) ----------------- 327
Viscosity at 100 F, cstk ----- ---------- ca 460
Partition Coef. (octanol/water ) >104
Appearance & Odor: A light yellow, viscous fluid.
SECTION IV. FIRE AND EXPLOSION DATA
Flash Point and Method | Autoignition Temo.
None to boiling point^^^^|
.
LOWER UPPER Flammability Limits In Air
Extinguishing Media: Use media appropriate to the. surrounding fire conditions. This
material has very low combustibility, but it can undergo theraal-oxidative
..
degradation in a fire situation.
Firefighters should use ful^protective clothing and self-contained breathing equipment
when fighting fire where^nv/ PCB's are involved.
SECTION V. REACTIVITY DATA
AROCLOR 1254 and other PCB's are nearly inert materials with very high chemical stabiliqy; the higher chlorine levels usually give the greater stability. At about 300 to 600 C some PCB s can oxidize to produce chlorinated dibenzofurans which are much greater in toxicity than the PCB's. For complete incineration of PCB's a 2-second dwell time above 2000 F (1090 C) with 3% excess oxygen in the stack is suitable (see. Sect. VII).
AROCLOR 1254 shows very little degradation after 3 weeks exposure to direct sunlight. .
PCB's are strongly absorbed on particulates or sediments in aquatic systems (streams, lakes, ocean, etc.).
Mixed in activated sludge, biodegradation occurs slowly, but only very slowly or almost not at all, with compounds above CI4.
GENERAL ELECTRIC
Copyright--1980 By General Electric Company
EX P-3275 _ Page 1 of 2
PCB-ARCH-EXT0380392
NO.
1200
* SECTION VI.- HEALTH HAZARD INFORMATION
TLV (See Sect. II)
PCBs show high levels of bioaccumulation in fatty tissue and very slow metabolism, es
pecially for CI5 compounds and above. They have become widely.dispersed in world-wide
environment and in the food chain (much like DDT) since their introduction in 1929.
Effective control of PCB discharge into the environment began after 1970. . AROCLOR l254has a low vapor pressure, but it can be irritating to the eyes, nose, and
throat if misted or heated to produce vapors. Excessive acute and chronic 'exposures
may cause liver damage. Chronic exposure to or 'lllgUSlilUU (if FCB11,1" (USVfecially when*1 tnermaliy oxidized) can result in chloracne after 1-6 months. There Is some evidence
of possible carcinogenic risk and adverse reproductive effects with this material. PCB
may appear in the breast milk of an exposed mother.
FIRST AID:
.
. .
Skin Contact: Clean exposed skin with waterless cleaner, wipe with a disposable.towel
then wash with soap and water. Promply remove contaminated clothing. :(Control
separate disposal of PCB-contaminatea materials.). .
.
Eye Contact: Flush promptly & thoroughly with lots of running water for 15 minutes.
Inhalation: Remove to fresh air. Get medical help if symptoms continue.
;
Ingestion: Get medical help. NIOSH has recommended that vomiting be induced.
Get medical help in all cases of severe exposure, repeated exposures, or persistent
symptoms.
_________ '
SECTION VII. SPILL, LEAK, AND DISPOSAL PROCEDURES
Notify safety personnel of all PCB spills or leaks. Promptly contain spilled materiali
Prevent its release into the environment! Restrict PCB spill area to.trained clean-up
personnel; use proper protective gear; follow an established emergency plan.
Stop leakage if possible. Pick up spill. Absorb small spills and residues using.a powdered, dry clay. Place leaking containers, picked-up PCBs, and_PCB-contaminated
materials and refuse into approved, properly labeled, closed containers for storage under controlled, EPA regulated conditions prior to disposal. .EPA allows approved
storage to 1/1/84.(See Sect.IX.) Storage: 40CFR761.42; Annual report: 40CFR761.45
DISPOSAL: Destroy PCB-containing material by burning in an EPA approved facility. Liquifi
50-5Q0 ppm PCB material can be burned as above or landfilled if not ignitable. Non flowing, PCB-contaminated debris can be disposed .of in an EPA approved landfill. .
(See 40CFR 761; Federal Register, Vol. 44, 31551-4, 66989; Vol.45, 20473.)
..
SECTION VIII. SPECIAL PROTECTION INFORMATION
Provide highly effective local exhaust ventilation (trap for exhaust vapors) especially
if this material is heated or misted. . .Unless authorized by EPA.an isolated system
must be used for PCBs.
,
|"T|
For nonroutine and emergency conditions of exposure use an approved canister respirator I
or self-contained breathing equipment.
.
I
Prevent skin contact for those who work with PCBs. Use neoprene or polyethylene gloVes .
and apron, safety glasses and/or face shield, and other protective clothing as deter
mined by use conditions. An eyewash station and.washing facilities should be avail
able to the work area.
.
.
Provide for special handling and disposal of PCB-contaminated materials, including paper towels and clothing (see Sect. VII). Provide locker and shower facilities. Workers
must be trained for PCB work, and they must follow good hygienic practice. Provide pre-placement medical exams for workers with emphasis on liver function, skin
condition, and reproductive history. Provide annual medical exams for.exposed workers
:
SECTION IX. SPECIAL PRECAUTIONS AND COMMENTS
PCB materials in containers and in equipment must have proper labeling including the date of storag_e. Short term (up_ to 30 da_ys) storag_e of non-leaking PCBs can e done
Long term storage requires an EPA approved facility, including such criteria as roof
and walls to shield from rain, impervious base, and diking which will contain 25% of stored volume or twice the volume of the largest container, no drains or openings to
allow flow loss, and the base must be located above the 100-year flood water elevatior
_ Prevent physical damage to containers. Inspect,storage frequently.. , ,,,,,, ,,
^
Prevent skin contact witn PCBs, or witn solid products contaminated with PCBs. Prevent
inhalation of airborne PCBs. Properly contain PCBs until legally disposed of; do not
allow them to escape into the environment!
\
PCBs. and especially used PCBs. can contain higher toxicity contaminantsJ
fkS0URCE(S) CODE: 1-6,20,26,31,36
^
~
Judgment* at to the suitability of information herein for purchaser't purposes ore
APPROVALS ~S: CRD
J
necessorily purchaser's responsibility. Therefore, olthough reasonable core hot been token in the proportion of such information. General Electric Company
Industriia 1l HLityttgt iene V ' I '
.
extends no warranties, mokes no representations ond assumes no responsibility os to the occurocy or suifobility of such information for application to purchaser's
and Safety
intended purposes or lor consequences of its use.
'
MEDICAL REVIEW:
GENERAL ELECTRIC
EX P-3275 Page 2. of.2
WW
PCB-ARCH-EXT0380393