Document X70E4JGDQNQK6gyGXLG7QGodg

MATERIAL SAFETY DATA SHEET CORPORATE RESEARCH & DEVELOPMENT SCHENECTADY, N. Y. 12305 Phone: (518) 385-4085 DIAL COMM 8*235-4085 SECTION I. MATERIAL IDENTIFICATION MATERIAL NAME: AR0CL0R 1254 ' DESCRIPTION: Distillation cut of polychlorinated biphenyl (or diphe eimrt OTHER DESIGNATIONS: PCB,. an Askarel, PYRANOL., GE Material A13B1, C," 27 323 188: MANU__F_A_C__T_U_R__E_R_: _M__a__t_e_r_i_a_l w__a_s a_ pr_r_o_d__u_c_t of M___o_n_s__a_n_t_o C. o..,, b__u_t d_ rop..pe. d_i_n_"_"_T_9_T__7_7' Except uses specifically exempted and regulated by EPA (for example power transformers), legal manufacture, distribution in commerce, and use of PCB's in USA ended in 1979 under- TSCA. , . SECTION II. INGREDIENTS AND HAZARDS HAZARD.DATA Mixture of Chlorinated Biphenyls, ^12^10-x^lx: x Approx. % 2 0.5 3 1 4 21 5 48 6 23 7 6 Includes 69 or more compounds with average of 4.98 Cl atom/molecule. MI.JJ ||_- chlorinated dibenzofurans. ca 100 EPA exemption or authorization needei for any measurable exposure* , Rat, Oral LD50 Adult 4-10 g/kg Weaning 1.2g/kg Rat, Intravenous LD50 358 mg/kg *Current ACGIHH 8o-hr TWA is 0.5 mg/m3. NI0SH has proposed z 10-hr TWA of 1.0 yg/m3. Materials with over* 50* ppm PClB content are regulated for handling, storage, records, and waste disposal- EPA criterion in navigable waters is 0.00T |iS7Lf. PCFr & ^ Rat, Oral, TDLo 1220 mg/kg/35 wk (neoplastic effect) SECTION III. PHYSICAL DATA Boiling range at 1 atm, deg C ------Vapor pressure at 150 C, mm Hg ----- [ ca 360-39 <1 Specific gravity (65/15.5 C) -- our point, deg Q ------------------------ 1.5 10 Water solubility at 25 C, ppm ------- ca 0.01 Molecular weight (Av) ----------------- 327 Viscosity at 100 F, cstk ----- ---------- ca 460 Partition Coef. (octanol/water ) >104 Appearance & Odor: A light yellow, viscous fluid. SECTION IV. FIRE AND EXPLOSION DATA Flash Point and Method | Autoignition Temo. None to boiling point^^^^| . LOWER UPPER Flammability Limits In Air Extinguishing Media: Use media appropriate to the. surrounding fire conditions. This material has very low combustibility, but it can undergo theraal-oxidative .. degradation in a fire situation. Firefighters should use ful^protective clothing and self-contained breathing equipment when fighting fire where^nv/ PCB's are involved. SECTION V. REACTIVITY DATA AROCLOR 1254 and other PCB's are nearly inert materials with very high chemical stabiliqy; the higher chlorine levels usually give the greater stability. At about 300 to 600 C some PCB s can oxidize to produce chlorinated dibenzofurans which are much greater in toxicity than the PCB's. For complete incineration of PCB's a 2-second dwell time above 2000 F (1090 C) with 3% excess oxygen in the stack is suitable (see. Sect. VII). AROCLOR 1254 shows very little degradation after 3 weeks exposure to direct sunlight. . PCB's are strongly absorbed on particulates or sediments in aquatic systems (streams, lakes, ocean, etc.). Mixed in activated sludge, biodegradation occurs slowly, but only very slowly or almost not at all, with compounds above CI4. GENERAL ELECTRIC Copyright--1980 By General Electric Company EX P-3275 _ Page 1 of 2 PCB-ARCH-EXT0380392 NO. 1200 * SECTION VI.- HEALTH HAZARD INFORMATION TLV (See Sect. II) PCBs show high levels of bioaccumulation in fatty tissue and very slow metabolism, es pecially for CI5 compounds and above. They have become widely.dispersed in world-wide environment and in the food chain (much like DDT) since their introduction in 1929. Effective control of PCB discharge into the environment began after 1970. . AROCLOR l254has a low vapor pressure, but it can be irritating to the eyes, nose, and throat if misted or heated to produce vapors. Excessive acute and chronic 'exposures may cause liver damage. Chronic exposure to or 'lllgUSlilUU (if FCB11,1" (USVfecially when*1 tnermaliy oxidized) can result in chloracne after 1-6 months. There Is some evidence of possible carcinogenic risk and adverse reproductive effects with this material. PCB may appear in the breast milk of an exposed mother. FIRST AID: . . . Skin Contact: Clean exposed skin with waterless cleaner, wipe with a disposable.towel then wash with soap and water. Promply remove contaminated clothing. :(Control separate disposal of PCB-contaminatea materials.). . . Eye Contact: Flush promptly & thoroughly with lots of running water for 15 minutes. Inhalation: Remove to fresh air. Get medical help if symptoms continue. ; Ingestion: Get medical help. NIOSH has recommended that vomiting be induced. Get medical help in all cases of severe exposure, repeated exposures, or persistent symptoms. _________ ' SECTION VII. SPILL, LEAK, AND DISPOSAL PROCEDURES Notify safety personnel of all PCB spills or leaks. Promptly contain spilled materiali Prevent its release into the environment! Restrict PCB spill area to.trained clean-up personnel; use proper protective gear; follow an established emergency plan. Stop leakage if possible. Pick up spill. Absorb small spills and residues using.a powdered, dry clay. Place leaking containers, picked-up PCBs, and_PCB-contaminated materials and refuse into approved, properly labeled, closed containers for storage under controlled, EPA regulated conditions prior to disposal. .EPA allows approved storage to 1/1/84.(See Sect.IX.) Storage: 40CFR761.42; Annual report: 40CFR761.45 DISPOSAL: Destroy PCB-containing material by burning in an EPA approved facility. Liquifi 50-5Q0 ppm PCB material can be burned as above or landfilled if not ignitable. Non flowing, PCB-contaminated debris can be disposed .of in an EPA approved landfill. . (See 40CFR 761; Federal Register, Vol. 44, 31551-4, 66989; Vol.45, 20473.) .. SECTION VIII. SPECIAL PROTECTION INFORMATION Provide highly effective local exhaust ventilation (trap for exhaust vapors) especially if this material is heated or misted. . .Unless authorized by EPA.an isolated system must be used for PCBs. , |"T| For nonroutine and emergency conditions of exposure use an approved canister respirator I or self-contained breathing equipment. . I Prevent skin contact for those who work with PCBs. Use neoprene or polyethylene gloVes . and apron, safety glasses and/or face shield, and other protective clothing as deter mined by use conditions. An eyewash station and.washing facilities should be avail able to the work area. . . Provide for special handling and disposal of PCB-contaminated materials, including paper towels and clothing (see Sect. VII). Provide locker and shower facilities. Workers must be trained for PCB work, and they must follow good hygienic practice. Provide pre-placement medical exams for workers with emphasis on liver function, skin condition, and reproductive history. Provide annual medical exams for.exposed workers : SECTION IX. SPECIAL PRECAUTIONS AND COMMENTS PCB materials in containers and in equipment must have proper labeling including the date of storag_e. Short term (up_ to 30 da_ys) storag_e of non-leaking PCBs can e done Long term storage requires an EPA approved facility, including such criteria as roof and walls to shield from rain, impervious base, and diking which will contain 25% of stored volume or twice the volume of the largest container, no drains or openings to allow flow loss, and the base must be located above the 100-year flood water elevatior _ Prevent physical damage to containers. Inspect,storage frequently.. , ,,,,,, ,, ^ Prevent skin contact witn PCBs, or witn solid products contaminated with PCBs. Prevent inhalation of airborne PCBs. Properly contain PCBs until legally disposed of; do not allow them to escape into the environment! \ PCBs. and especially used PCBs. can contain higher toxicity contaminantsJ fkS0URCE(S) CODE: 1-6,20,26,31,36 ^ ~ Judgment* at to the suitability of information herein for purchaser't purposes ore APPROVALS ~S: CRD J necessorily purchaser's responsibility. Therefore, olthough reasonable core hot been token in the proportion of such information. General Electric Company Industriia 1l HLityttgt iene V ' I ' . extends no warranties, mokes no representations ond assumes no responsibility os to the occurocy or suifobility of such information for application to purchaser's and Safety intended purposes or lor consequences of its use. ' MEDICAL REVIEW: GENERAL ELECTRIC EX P-3275 Page 2. of.2 WW PCB-ARCH-EXT0380393