Document VzyDZgjJO9V1aegKDvB0jdjK

Monsanto Chemical Company OATS ISSUEO 8/4/72 IRAas 1 *'5 MWMEB* 13,268 c. 0. KRUMMRICH RLANT LABORATORY WTTT1M IV WRMVU IT STANDARD ANALYTICAL METHOD pkoouct ""....... " JHFrancts HJHorner ATTACHMENTS Sample Chromatograms (3) MCS1016, 1242 Aroclor, Monochlorobiphenyl (Crude and Finished Goods) TEST Higher Bolling Homologs SUPERSEDES METHOD_________________ ISSUED OH 7/20/71 ) REVISES INSTRUCTIONS of 7/20/71. T-2302 SCOPE This procedure determines higher boiling homologs In MCS 1016 and in 1242 Aroclor. Approximate Isomer distribution can also be determined on MCS 1016, 1242 Aroclor and monochloroblphenyls. DO HOT USE THIS PROCEDURE WITH HIGHER CHLORINATED BIPHENYLS. THEY ELUTE FROM THE GLC COLUMN WITH EXTREME DIFFICULTY AND (5NLY AT TEMPERATURES THAT DRASTICALLY SHORTEN COLUMN LIFE. EQUIPMENT AND SUPPLIES 1. OLC Instrument, Varian-Aerograph Model 144410-00, flame Ionization detector, capillary splitter, linear-programmed, single column. Varian-Aerograph, 2700 Mitchell Drive, Walnut Creek, California 94598 (or equivalent). 2. Recorder, any good 1 mv. full scale, 1-second or less response time equipped with DISC or electronic Integration. 3. Column, 50 ft. x 0.02 inch I.D. S.C.O.T. column with FFAP liquid phase. Perkin Elmer Corp., Norwalk, Conn. 06852. 4. Syringe, 0.2 ul fixed-volume. Precision Sampling Co. Cat. No. 200002 (or equivalent syringe to deliver 0.2 ul). Fisher Scientific Co., 1241 Ambassador Blvd., st. Louis, Mo. 63132. 5. Standard samples for calibration are available from E. M. Emery, Monsanto Co., 800 N. Lindbergh Blvd., St. Louis, Mo. 03166. SAFETY Chlorinated biphenyls are now considered environmental contaminants. Handle with care and dispose of waste and spill cleanup in the pre scribed containers. GLC injection ports and ovens are usually very hot. Take care not to touch the hot equipment. HONS 0U8J4 Product: Test: MCS 1016, 1242 Aroclor, Mono- Method No. 13,268 chlorobiphenyl (Crude & Finished page 2 or 5 pages Goods) Higher Boiling Homologs INSTRUMENT CONDITIONS Injection Port Detector Column Oven Range (Input) Column Helium Flow Splitter Flow Hydrogen Air Injection 325 + 10"C 320 235C Isothermal* 10-11 Amps /tav 10 cc/min. at room temperature 50 cc/min (equlv. to a 5-1 split) (12 secs./lO cc) 30 cc/min (20 sec/10 cc) 300 cc/mln (2 secs/10 cc) 0.2 ul * Column temperature may be adjusted downwards as the column ages, to maintain retention time. Different column temperature may be necessary for monochloro- blphenyl isomer distribution. Normal back-pressure at the injection part is 12-18 pslg. DETERMINATION 1. Bring the instrument to the conditions described above for at least 5 minutes. The baseline should be stable at 4-1 attenuation. Set the attenuator at 256-1 before Injecting the sample If Disc Integration Is to be used. Electronic integration can be at any attenuation but the RANGE setting must not be changed during a run. 2. load the syringe by Immersing the needle at least 1 inch below the surface of the sample and moving the plunger in and out slowly for at least 5 cycles or until the small bubbles of air are no longer expelled from the needle. Wipe the needle off with a soft tissue. 3. Depress the computer start button to activate the computer scan and Immediately Inject the sample into the GLC. Leave the needle in the injection port for 5-6 seconds and then withdraw slowly. 4. If Disc Integration Is used the attenuation must be changed to 2-1 or l6-l after 16 minutes (new column) so that the high boilers elute with a large enough peak(s) to Inte grate accurately (see sample chromatograms). MGNS 071875 Product: Test: MCS 10l6, 1242 Aroclor Monochloroblphenyl (Crude and Finished Goods) Higher Bolling Hemologs Method No. 13,268 Page 3 of 5 pages DETERMINATION (Cont'd.) 5. The chromatogram should he complete in 20 minutes for MCS 1016 and In 30 minutes for 1242 Aroclor. Monochlorobiphenyls should be complete in less than 20 minutes. (If the computer program is used it will automatically end at 30 minutes for all samples.) 6. Determine the counts under the MCS 1016 peak envelope (l-l6 minutes) and for the combined higher boiling homologs (16-30 minutes). CALCULATION # Higher Bolling Homologs Area for High Boilers x 100 Total Area * Monochlorobiphenyls will require area correction factor for B10. See sample curve. Report the results to the nearest 0.01#. Duplicate analyses are expected to check to within 0.04# (actual). Precision data should be collected as soon as is feasible. DISCUSSION According to recent information pentachlorobiphenyls and higher chlorinated isomers are very difficult to biologically degrade and tend to concentrate in fish and birds. This test is being performed to help keep these Isomers to a minimum in MCS 1016. This procedure was adapted from Method No. 71-11, Job No. 1348522, Physical Chemistry Dept. The procedure compares Disc and electronic integration and results are comparable and within expected tolerances. cn?b product: Test: MCS 1016, 1242 Aroclor Monochlorobiphenyl (Crude and Finished Goods) High Bolling Hemologs Method No. 13,268 Page 4 of 5 pages DISCUSSION (Cont'd.) Apparently different S.C.O.T. columns vary considerably. W.G.K. columns at the same conditions as those specified in Method No. 71-11 give considerably longer retention times and Improved separation with less tailing. Column life is expected to be about 1 month at 235*C. Column life can be extended if when there are to be no samples for several hours the column temperature Is reduced to 150C. It should only take about 30 minutes for the column to restabilize when the temperature is again increased to 235C. A spent column will be indi cated when the peaks show marked tailing and Iobs of separation of some of the doublet peaks. If In doubt refer to the sample chromatograms. Monochlorobiphenyl is a relatively new product and standards are not presently available to prepare a sample chromato gram. It is expected that the column temperature will have to be reduced to about 200C to effect a proper separation of the Isomers. Order of elution of components will be Biphenyl, o-Chloroblphenyl, m-chloroblphenyl, p-chlorobiphenyl, then dichloroblphenyls and trichlorophenyls. Higher chlorinated Isomers are not expected to be present. We expect production to eventually ask for analysis of Recovered Biphenyl for chloroblphenyls. The Recovered Biphenyl will probably be a solid at room temperature. Dilution in benzene (1-1 volume/volume) and injection of 0.5 ul should handle this type sample. (Benzene counts would then be ignored in the area normalization.) A 1 ul syringe with the plunger in the needle should be used for this injection. Hydrogen and air flows can be checked by attaching a bubble meter to the flow diverters on the right side of the instru ment and pushing in all the way. When finished checking the flows make sure the diverters are pulled aTl the way out and then re-ignite the flame detector. Column flow is checked by disconnecting tne column exitend and checking the flow with a bubble meter. Splitter flow is checked at *ONS 071677 Product: Test: MCS 1016, 1242 Aroclor Monochloroblphenyl (Crude and Finished Goods) Higher Boiling Hemologs Method No. 13,260 Page 5 of 5 pages DISCUSSION (Cont'd.) the split exit on the right side of the instrument. These flows should he checked at least once a week or whenever abnormal operation is suspected. Occasionally the flame becomes extinguished for unknown reasons. If after an injection has been made and peaks are overdue or extremely small check to see if the flame is still lit by holding in the igniter button for about 5 seconds. The cap on the detector will usually "pop" if the flame was out. The injection must then finish eluting before on analysis can be restarted. "The information contained herein is, to our best knowledge, accurate; but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. Monsanto disclaims any liability for loss or damage Incurred in connection with the use of the above." MONS 071878 *GNS 071879