Equipment Continu'd
diaphragm eliminates stuffing box and iso* lues chemicals from pump parts. Pumps are micro-adjustable over the entire ca pacity range white in operation. Four sites are available (er flows from tero to II, 40, 100. to 330 gpk Duplex, triplex, and other multiple-bead arrangements are offered for contfmtoua blending or feeding. Various valve design*, diaphragm materials and ma terials of construction are offered to meet the chemical requirement* of specific ap plications. Process Equipment Dlv, Lapp Insulator Co, 743 Maple Street, U Roy, N. Y.
Industrial Power Unit
water spray to remove 1000 Btu for each pound of water evaporated. -
The eating it partitioned ao that damper operation permits use of ail fresh air or any degree of recirculated air. The proportions vary with condensing load and with changea in air temperature according to weather. All dampen are located internally. Aero-' pojs condensers are manufactured lo units ranging from 10 to 100 tons rated capacity. Niagara Blower Co, 403 Lexington Avc,
New York 17, N. Y.
system utilises a single-bore capillary and a single bourdon spring with a U-ahaped bimetallic compensator on the spring for cose temperature changes- Uniform charts
are used end the system is available with the usual fittings, armor, etc. Taylor in.
atrament Cos, Rochester 1, N. Y
'
Alr-Une Filter
Moon. 60S Lusni-FiLTCn combines a lubri cator and filter and is designed for com- . preaaed-alr lines. It protects air-driven ; equipment against dry-running breakdown! . and Impurities in the eir supply. Atom- ised oil U automatically injected into the air line in proper amounts and nil level J may bo seen from any angle. Filler h built of aluminum and brass. Jarett Com- pressor & Equipment, Ine, 273 Central : Avc, Newark 4, N. J.
;
i
KHW industrial rowsa uiu? comprises Ford 100-hp engine, capable of operation on natural or bottled gas as well as gasoline, oesembled with radiator, fan, governor, battery-aurtfng .system, ind Instrument panel. Built-in protective device breaks
Ignition circait and stops engine if water temperature rises above 19S F or lube-oil
pressure (alls below 6 pal. Available in open sod closed models, with or without clutch (or direct drive, and with extension base (or apodal mounting. Can also bo furnished wftb 20-kw generator or centrifugal pump
on same bate. . Suitable for direct drive ef compressor!, pumps, etc, and for generator drive (either regular or standby service), power unit may be rated at 2250 rpm, yielding 64 hp on gasoline' and S5 hp on natural gas for abort periods, 43 and 36 hp respectively, for constant-duty power. Speed of 1600 rpm Is recommended as most economical for load* from 10 to 50 hp. K R Wilson, 215 Main Street, Buffalo 3, N. Y.
Molar Starter
Regulator Diaphragm
Nvton fabric is combined with rubber to
make a naw sheet material (or pressure-
regulator diaphragms. 'Die new material has greater flexibility, is lighter in weight, *'
and has higher bursting strength and itn- '
proved sensitivity, says the manufacturer. (t can be supplied in sheets 36 in. wide 1
and 1/32. 1/16. 3/16 and J in. thick / Sheets may be die cut to fit various prts- . lure regulators used to control the flow ol water, air, oil, steam, acetylene, illumiruling gas, chemfcata and other liquid* ' and gases. U. S. Rubber Co, Rockefeller ol
Center, New York, N. Y.
V
RxccwTir ot$ieneo YaUmiw motor start ers may be used at any point on any power aytiem, regardless of the available kva. These new starters are for 2300-4600-v applications. Fault current Is limited on any system to about 25,000 kva, which (a easily interrupted by the magnetic contactor. As a result all apparatus on the system back
lo the power source Is subject to reduced stresses should a short circuit occur In the rumor or line protected by Veiimitar.
The motor starter is built to provide across-the-line itarting for squirrel-cage, synchronous or wound-rotor motors. A style
Is also available for reduced voltage aton ing. The 2300-v top rating is 600 hp (or 60 cycle and 300 hp for 25 eyele systems. Similar ratings hold for 4150- tnd 4600-v systems. Etcelrk Controller A Mfg Co, 2700 E 79th St, Cleveland 4, Ohio.
Cat Condenter
Two coil, refrigerant gas condenser passes gas over 0) a dry "Duo-Pass" coll, which, together with an "Oil-Out," removes super* heat, condenses and separates oil vapor (2) a wet coll that condenses gas at a low tem perature. This last coll is drenched by `a
Temperaturt Inilrumant
Sinclb CAPiLUnv, organic-liquid actuated temperature system Is particularly adapt able lo applications where (I) a small bulb is required; (2) short range inisrvats are desirable; (3) manufacturing process fs sensitive to mercury; (4) subsere temperatures ate encountered. The
Dcoiler tuutovsa oil, oil emulsions, scab; and decomposed, oil from boiler fee water and from water for Industri*' processes. It consists of a closed venial
cylindrical shell that contains the sepsn^
ing and filtering elements. Knitted star wire, the baiio separating material, *
placed on hollow cylinders with walls ol a? proprlato thickness for the panicular dc
sign. Usually each unit has three cylindo
' .
120 |OS)
fOWfll July
;
Because each condenser and heat exchanger presents its own special combination of conditions, no blanket recommendations for condenser tube alloys are pos sible.'However, this much can be stated authorita tively: there are three Revere Metals which deserve special consideration in cases of limited or unsatis factory tube life. Here they ore:
Cupronickel, 30%. Withstands high operating temperatures. A tenacious surface film forms on fhis metal, whleh resists impingement attack and erosion, sail water, and waters containing organic material. Widely used in marine and seaboard installations, the tropics ond sub tropics.
Cupro-NIckel, 10%. Similar to Cupro-Nkkel,
but lower In price and somewhat less resistant to certain types of corrosion,
Revalon (Aluminum Brass). This Revere Metal
contains a small proportion of olumlnum, which
,0wi J.l, mi
gives it o long Ufe in applications where water velocities are high or water Is soline. The film . formed on this tube it tenacious and self-healing, rendering It highly resistant to impingement attack.
Which of these types to select, or which of the five other, types of Revere Condenser Tabes should be chosen, depends on individual conditions. The Revere Technical Advisory Service will gladly collaborate wi(h you in arriving at a decision as to the most economical tubes for your plant.
REVERE
COPPER AND- BRASS INCORPORATED
Pmmird if Peal Rtptrt m t<QI 230 Park Avenue, New York 17, New York Mills Betilmfr*, Md: CUnn UU Ovfrott M/cti Nrv SW>nt Nmi; Kim ft Y.--Sein QJlctt ht Prietos!CHkt, DiMriitten