Document Vjv3J0kxVMQNKyDzOGBn6xnZp

HEATING VENTILATING AIR CONDITIONING GUIDE 1944 Table 1. Average Maximum Water Main Temperatures* State ClTT Temp. F State ClTT Temp. F Ala_____ Birmingham.. ____ Mobile____________ Ariz______ Phoenix.___________ Tucson____________ Calif..:____ Anaheim___________ Berkeley............ ....... Fresno. Fullerton__________ Glendale________ Los Angeles Oakland___ _______ Ontario ________ _ Pasadena__________ Pomona. Riverside Sacramento________ San Bernardino____ San Diego. .:_ ___ San Francisco_____ Whittier___________ Colo______ Denver____ Conn. Bridgeport_________ Hartford____ :... New Haven___ Waterbury................ D. C____ Washington.............. Del_______ Wilmington............. Fla_______ Jacksonville_______ Miami........ ,, . .. Tampa__ .....______ Ga- ... . Atlanta.. . . ____ Macon.......... ........... HI....... ........ Chicago.___________ Cicero_____ ______ Evanston__________ Peoria........ _ ___ Rockford____ -_____ Springfield_________ Jnd__ ____ Evansville............... Gary.__________ .___ Indianapolis South Bend......--__ Terre Haute_______ Iowa._____ Cedar Rapids.. . .. Des Moines________ Sioux City_______ ... Kans_____ Concordia;_______ . Kansas City_______ Topeka... Wichita. ........ Ky----------- Louisville__________ La. . New Orleans_______ Me_______ Augusta........... Md____ Baltimore__________ ' 84 73 81 80 60 69 72 75 68 75 69 70 82 75 78 72 65 82 . 62 75 75 66 73 76 72 84 83 80 80 77 87 80 76 76 73. 67 59 82 86 75 80 61 82 78 77 62 57 86 88 72 85 85 85 60 75 Camhridge.. v Fall River _ .......... Lowell- _______ Lynn.... ..................... New Bedford ____ Salem.................-- ... Worcester. ....... Grand Rapids.......... Highland Park._ Jackson.......... ........... Kalamazoo............... Lansing___________ Saginaw..................... Minn.__... Duluth....................... Minneapolis____ ... St. Paul ............... Mo............. Jefferson City.......... Kansas City......... ... St. Joseph. St. Louis. ________ Nev______ Reno_;------- - --------N. H_____ Manchester.............. N. J._........ Jersey City.. ____ Newark. .................. N. Y... ....... Albany............... -..... Jamaica.- __ . Mt. .Vernon..-......... New Rochelle' .. New York. Schenectady. ___ Utica__________ ____ Yonkers___ ;............. N. C_____ Charlotte____ _____ Winston-Salem____ N. M....... Ohio ___ Akron__________ Cleveland.... ______ 80 70 76 50 68 70 68 76 77 70 84 77 56 53 64 82 55 80 77 82 84 84 85 70 63 87 61 76 63 74 78 79 68 75 56 74 75 72 70 60 74 69 70 74 . 85 82 65 76 50 84 74 - Dayton__ _________ Lakewood. _______ Springfield____ ___ Toledo. .................... 60 82 72 83 "These averages taken from various city water main locations, with-some actual values slightly higher ana some lower than values shown. 528 CHAPTER 27. SPRAY EQUIPMENT Table 1. Average Maximum Water Main Temperatures (Concluded) State ClTT Tsar. F State Cnr Temp. F Okla______ Oklahoma City___-- Tulsa______________ Ore.... ........ Eugene__ _________ Pa....... ....... Altoona____________ F.rip Johnstown_________ McKeesport._______ Philadelphia_______ R. I______ Providence.............. S. C--------- Charleston________ Spartanburg. .......... Tenn_____ Chattanooga............ Knoxville_______ __ Nashville _ ___ Amarillo.................... Austin........................ Beaumont-- ........... Fort Worth............ Galveston........ ......... Houston.................... , Port Arthur.............. Wichita Falls. ___ _ 82 85 60 64 74 75 74 82 83 SI 68 80 81 78 55 84 89 70 90 65 90 86 86 84 90 84 83 76 85 Utah_____ Logan.... ................. Salt Lake City.____ Va............. Fredericksburg____ Norfolk. ______ ... Wash Seattle___________ Spokane___ _______ Tacoma____________ W. Va... Huntington............... Wheeling.__________ Wis............ Madison___________ Racine......... ............. 44 60 75 73 80 58 62 51 57 85 78 78 54 58 70 68 Province B. C______ Vancouver.:_______ Ont_______ London...... ............... Toronto___________ P. E. I......: Charlottetown_____ Que---------- Montreal__ Quebec____________ 64 60 50 63 48 78 68 These averages taken from various city water main locations, with some actual values slightly higher and some lower than values shown. spray temperature the greater the amount of moisture removal per pound of dry air, all other conditions remaining the same. Washers with two or more banks of sprays are usually selected for comfort air conditioning installations. Such washers will cool the air to within 1 or 2 F of the leaving spray water temperature. Where a limited, supply of cold water is available multiple stage washers may be used to an advantage. The cool water is pumped through the multiple spray systems in series. By this arrangement the entering air is cooled first by the warmer water and finally by the cooler water which gives the maximum amount of cooling with the minimum amount of water. The approximate temperatures of water from wells at depths of 30 to 60 ft are given in Fig 31. Frequently the temperature of the city water main supply is low enough during the summer to permit an ap preciable cooling effect. Table 1 lists the maximum city water main temperatures for various localities in the United States and Canada. Air washers using refrigerated spray generally have their own recircu lating pumps. These pumps deliver to the sprays a mixture of water from the washer sump, which has not been re-cooled, and refrigerated water. The quantities of each are controlled by a three-way or mixing temperature of Water Available for Industrial Use in the United States, by W. D. Collins (U. S. Geological Survey, Water Supply Paper No. 620 F). 529