CHAPTER 40
1960 Guide
of tiie evaporative condenser have been started. In some cases, an automatic damper is used on the inlet of the evaporative condenser to provide proportional control of head pressure on tiie refrigeration system. See Chapter 43 for general information on controls.
REFERENCES
* W. D. Collins: Temperature of Water Availablefor Industrial
. Use in the United States (U. 8. Geological Survey. Water Supply
Paper No. 520F). 1 R. F. Throne: Cooling performance of an industrialized
lake surface (Power, September 1051). * 8. Hori, U. A. Patehett, and L. M. K. Boelter: Design of
spray cooling ponds (ASHVE Journal Section, Heating, Pipxng and Air Conditioning, October 19-42, p. 624).
4W. H. Walker, W. E. Lewis, W. H. McAdams,'and E. R. Gilliland: Principles of Chemical Engineering (McGraw-Hill Co., New York, 1937, p. 480).
` D,, Q. Eem: Process Heat Transfer (McGraw-Hill Co., New York, 1950, p. 563).
* W. K. Lewis: The evaporation of a liquid into a gas (ASMS Transactions, Vol. 44, 1922, p. 325).
1 F. Merkel: Verdustungs kuhlung (Forsckungarbeiien, No. 275, 1925).
* H. B. Nottage: Merkel's cooling diagram as a performance correlation for air-water evaporative cooling system (ASHVE Transactions, Yol. 47, 1041, p. 429).
* W. H. McAdams: Heat Transmission (McGraw-Hill Co., New York, 1933, p. 157).
14 A. L. London, H. B. Nottage, and L- M. E. Boelter: De termination of unit conductance for heat and mass transfer by the transient method (Industrial and Engineering Chemistry, April 1941, p. 467).
u Joseph Lichtenstein: Performance and selection of me chanical-draft cooling towers (ASME Transactions, 1943, p. 779).
"D. R. Baker and L. T. Mart: Analysing cooling tower performance by the unit-volume coefficient (Chemical En gineering, December 1952, p. 196).
u J. C. Albright and D. R. Baker: Summer Weather Data (The Marley Co., 1944).
M D. R. Baker: Studies relative to protection of cooling tower lumber (ASME Oil, Gas and Power Division Proceedings, June 1954).
CHAPTER 41
EVAPORATIVE AIR COOLING AND HUMIDIFICATION
Apparatus for Humidification, Spray Generation, Spray Distribution, Unit Humidifiers, Air Washers, Humidification with Air Washers, Dehumidification and Cooling with Air Washers, Evaporative Air Coo//ng, Types of Direct Evaporative-Cooling Equipment, Design Considerations, Confro/j, Maintenance
EVAPORATIVE air cooling and humidification increase induce air flow through a casing or duct for distribution of the moisture content of an air stream or the air in a the spray. Fan propulsion uses a power-driven fan to dis selected space, with or without a change in dry-bulb tempera tribute the spray.
ture. Evaporative air cooling applies the well-known phenome
Atomizing Humidifiers
non of evaporating water at ambient temperature into an air stream. If no heat is added during the process, the dry-bulb temperature of the air stream is reduced along the thermo dynamic wet-bulb temperature line with a consequent in crease in latent heat and moisture content.
Humidijieation, used industrially and in residential airconditioning and heating systems, may be accomplished by evaporative air-cooling apparatus, by the direct introduction of water spray into the air stream or space either by heated evaporating pans or steam jets. Some equipment can be used
In several types of atomizing humidifiers nozzles are placed within the room. Compressed air effects complete atomiza tion of the water which is converted into vapor by the heat of the room air. In some of these nozzles an aspirating effect draws the water into the nozzle and atomizes it. Others are operated on a combined air and water pressure. It is usual for nozzles of the water-pressure type to be controlled by a diaphragm valve actuated by the pressure of the atomizing air.
for both cooling and humidification.
High-Duty Humidifiers
APPARATUS FOR HUMIDIFICATION
Humidification may be direct or indirect, i.e., water in droplets or vapor form may be introduced directly into the humidified space, or previously humidified air may be circu lated in or through the space. Evaporative air cooling is al ways indirect although the cooling may be accomplished by wetted surface or secondary cool surface.
The classification of apparatus used for humidification and evaporative air cooling is shown in Table 1.
HUMIDIFICATION SPRAY GENERATION AND DISTRIBUTION
Spray generation is obtained by (1) compressed air, (2) impact, (3) hydraulic separation, and (4) mechanical sepa ration. Atomization *An be accomplished by the use of a com pressed air jet to reduce the water particles to a fine spray. With the impact method, a jet of water under pressure im pinges directly on the end of a small round wire. Where hy draulic separation is employed, a jet of water enters a cy lindrical chamber and escapes through an axial port with a rapid rotation which causes it to separate in a fine coneshaped spray. In the mechanical separation process, water is thrown by centrifugal force from the surface of a rapidly revolving disc and separates into particles sufficiently small to be utilized in certain types of mechanical humidifiers.
Spray distribution is obtained by (1) air jet, (2) induction, and (3) fan propulsion.
Air-jet distribution utilizes the atomizing jet to distribute the spray through the space. Induction distribution utilizes the aspirating effect of an impact or centrifugal spray jet to
Water is supplied at about 150 psig to an impact-type spray-generating nozzle located in a cylindrical casing. A drainage pan provides for the collection of unevaporated wa ter which is returned to a filter tank. A powerful air current from a fan mounted above the unit, flows through the cyl inder and is charged with moisture. Air discharges from an opening below at a high velocity in a complete and nearly horizontal circle. The spray is evaporated and the resulting vapor is diffused and distributed.
Spray Humidifiers
This type uses a spray nozzle in a cylindrical casing equipped with a drainage pan. The aspirating effect of the nozzle induces a moderate air current through the casing which distributes the entrained spray. The general method.of circulating and returning the water is rimilaT to that em ployed for high-duty humidifiers. A suitable pump and cen trally-located filter tank are required.
Self-Contained Humidifiers
In this type mechanical or centrifugal means are used to generate and distribute spray. They may be used either singly or in groups. In large installations, where suitable connections are provided to permit the cleaning and servicing of individual units without affecting the room as a whole, group control of the water and power may be employed.
UNIT HUMIDIFIERS
The term unit humidifier denotes an assembly of elements the principal function of which is to humidify. The essential