Document VjYrrkVLw71NGgXNmX56E1OX8
- 78 -
^u u
Bidder,radatt on-Runbon (Hainprlze/Vodden)
.
Improvement In analytical technlouos using capillary column CLC has yielded further results on degradation residues which sug gest that MCS 1016 may be a bigger Improvement over Aroclor 1242 than wc had previously estimated. We have also had access to
other workers' results which have enabled better Identification of chromatogram peaks to be made. We also have some results of feeding trials which show that degradation of many Isomers In
animal organs is different from that Induced by micro-organism of the types we have so far studied, on the basis of these re
sults vie conclude that residues from MCS 1016 would be very small and our present view Is that MCS 1016 does provide a very sig nificant improvement over Aroclor 1242 from the environmental viewpoint. Further work is planned to substantiate these views during the next few weeks.
Aroclor Pollution Study-Anniston (I. Ransaw)
Carbon Adsorption Study
PKM) Report tlo. 2 covering the evaluation of Aroclor removal from
waste streams by carbon adsorption was issued under Job "446-514. (copy attached)
> Pi lot Clarification Stud
.
The pilot clarification unit has been operating since March 15 with minimum mechanical difficulties. Initial test runs wore made with optimum coagulant concentrations -- 15 ppm of bentonite clay and 1.5 Beta polyelcctrolyte 1170 (determined in lab by jar test) - at a 5 gpm flow to the clarifier. Results (Table I) indicate that the floe is not consistent in reducing the Aroclor level to 10 ppb, although the expected solids level is realized. Of interest here is the fact that solids in the plant effluent averaged approximately
50 ppm during the test period. These levels are considerably lower than the 100 to 1000 ppm values recorded when this study was Initiated. As a result, more bentonite clay is being added to pro
vide more surface area for Aroclor to bo adsorbed.
Table II contains the results of the study in which the clay con centration in the feed was increased to 30 ppm without a significant reduction in the Aroclor levels.
At this point it was felt that a close approximation of the optimum
clay concentration could be realized in a loss time-consuming,
batch type adsorption operation in the premix tanks (i.o., whose
walls were believed to be saturated with Aroclor from continuous
exposure). This effort proved fruitless except there were some
indications that clay would reduce the Aroclor level to the desired
value.
MONS 087481
- 80 TABLE I AROC 1.01! REMOVAL BY. FLOCCUL AT I OH CL AR1 FI CATIOH .
Tes t Conditions :
Clay cone, in feed
- 15 ppm
Polymer cone, in feed - 1.5 ppm
Flow through clarifier - 5 gpm
Avg. Influent Concentration
Volume Treated
(gal )
9.600
16,800
25,800
Sus
11-1260
pended
or
Solids A-1221 A-1242 11-1254
446 240
70
22 16 -210 60
.
Avq. Effluent Concentration
Suspended Solids
(ppm)
. A--1221
A-1242
A - T 254
31 11 6
15 23 --
NDA
1
41 ,600 29 100 14 ...
48,800
196 38 --
52,400 52 146 30 --
57,600 40 560 7 --
64,800 14 105 28 - -
18 72 8 * __
100 10 --
2 no 12 --
11 66 6 --
2 58 9 _ _
MONS 087482
- 81 .TABLE II
.
AROCIOR REMOVAL IVV ADSOlil'TI ON - FLOCCUL ATI ON
\ Tes t Conditions :
Avg. flow
- 5 gpm
Bentonite clay concentration in feed - 30 ppm
Betz polymer 1170 in feed
. - 1.5 ppm
Volume Treated
(ga1-)
1,500
13,200
Avq. Influent Concentration
Sus pended Solids
(ppm) A-1221
A-1242
A-1254
24 86 18 --
46 320
40
Avq. Effluent Concentration
Sus pended
Solids (ppm) A-1221
A-1242
A-1254
50 41 7 --
7 64 5 --
20,400
314 236 117
--
8 19 15 --
27,600
65 146
54 -- . 10
63
7 --
34,000
13 290 160
--
3 88 7 --
42,000 49,200
9 154 10 -38 73 25 --
5 17 4 --
22 25 4 ,, _
MONS 087483
TABLE III AROCI.OR REMOVAL BY APSORPTI OH - FLOCC ULATIOM
Test Conditions:
Clay concentration in feed
- 120 ppm
Polymer concentration in feed - 1.5 ppm
Avq. Influent Concentration
Avq. Effluent Con centratio n
Volume Treated
(gal.)
1,650
8,850
Sus pended
Solids (ppm)
A-1221
A-1242
I
1 254
480 380
--
210 13 --
' Sus pended
Solids (ppm)
' A-1221
A-1242
A-1254
. 80 30 --
6 2 --
16,050
52 . 42
11 9 --
hons