Document VjR9mXnYRxoJE3K1JdeevZEQN

PLAINTIFF'S EXHIBIT V~ DATE: October 12, 1984 TO: Mr. R. A. Cox Houston, Texas FROM: Mr. L. T. Townsend Port Arthur, Texas SUBJECT: SAF - Industrial Hygiene Program Evaluation Attached, as you requested in your September 27, 1984 letter, is Port Arthur Plant's response to the industrial hygiene program evaluation questionnaire. Responses are in the same order as the questions RSH:JMB Attachment r:t?o ,/, - \ WA-TEX 001181 ANSWERS TO INDUSTRIAL HYGIENE QUESTIONNAIRE 1. Respiratory Protection for Hydrogen Sulfide is as follows: Canister Gas Mask - tank gauging - 400 ppm H^S vapor space concentration. SCBA - Tank gauging - 400 ppm H,,S vapor space concentration H,,S greater than 10 ppm HgS in other areas - Breaking into line with unknown concentrations of ^S 2. Respiratory Protection for asbestos is as follows; 3 M 9920 or MSA Comfo II with Type F filters 3. Respiratory Protection in confined spaces See attached card. 4. How often is each employe formally trained/retrained in Respiratory Protection? On the average, every two years. 5. The Gas Mask Shop issues respiratory protection. 6. The Gas Mask Shop cleans respirators. 7. The Gas Mask Shop is responsible for storing and maintaining respirators. 9. Yes 10. Yes 11. Yes 12. Monthly 13. 950 14. Yes, some. 15. Those who work 50% of time or greater on job where 8 hr TWA is 85 dBA or greater. 16. Medical Department 17. Those showing ah OSHA-STS are notified in writing the day of the test. \ 18. Industrial Hygiene Department. Insert devices are not initially fitted. 18A. Medical Department and Industrial Hygiene Department advises on the effect of noise. Training provided upon employment and during scheduled audiograms. WA-TEX 001X82 n* * 2- - 19, Industrial Hygiene Department Program calls for new contour on unit every three years. 20. In service 8 Transformers 18 Capacitors Out of service 1 Transformer Items In storage will be disposed of within one year from the date they are removed from service, 21. Yes 22. October 11, 1983 23. Superintendent-Environmental, Health & Safety 24. Yes 25. Yes 26. Yes 27. In progress now. 28. Everyone has been trained once. Operators have been trained twice. Routine bulletin items issued. 29. Yes ' 30. Yes 31. Yes and safety meetings are held with contractors when they first move in on job. Pre-bid meetings are held. 32. No, however we have a standard safety exhibit that is included in all contracts. 33. Yes, on first report. We do not get a report on all contractor injuries or illnesses. 34. No, 35. Yes 10 J. L. Duplechin and S, W. Addison (Alternate) ^ 36. Continuous gas monitors are to be used when personnel are required- to enter any enclosed vessel which may contain combustible gases. A continuous gas monitor is not required for all hot work. WA-TEX 001183 -3- 37. 0!TLEL Lead-in-air test taken after tank is clean and dry. 38. No. Some tank cleaning jobs do not require respiratory protection because of ventilation and nature of product. 39. 20% Staff work 20% Complaint/accident investigation 5% Plant inspection 10% Training 10% Insurance claims/loss control 5% Issuing permits/inspecting permitted jobs 20% Industrial hygiene sampling 10% Litigation 40. Yes, when results exceed OSHA allowable limits 41. Yes 42. Local exhaust not required. Where possible general dilution is required. 43. Face velocities measured every 6 months. Minimum face velocity is 125 fpm, 44. Yes, one. Yes, two. 45. Yes 46. Urine samples provided every six months. Employes included are: a. 7th Street pumphouse operators b. PAT night foreman c. PCD octane lab technicians and machinist d. Shipping Division personnel concerned with TEL blending. 47. Most industrial hygiene activities are handled in-house. 48. Standardized programs for Hazardous Communication Standard, training aids. 49. NA 50. NA 51. NA 52. Yes 53. Hazardous Communication Standard 54. No No 55. Yes Yes [ WA-TEX 001X84