Document VjDv58GgX2neMVVOkjm8Y0OL4
ABDOO136625
PJIC
ABERDEEN CHEMICAL PLANT INDUSTRIAL HYGIENE MONTHLY REPORT
Routine Chemical Dosimetry All Sample Results:.
Month of: May Date of Report: June 19, . 1984
Chemical VCM Lead Total Particulates Overexposures Job Class Chief Operator
Reactor Operator
Reactor Operator
Reactor Operator
PEL No.
^ PEL Overexposures No.
81 88 11
39
97.5
1
4 100.
0
12 2.5 0
Exposure 16.0** ppm, VCM
1.8* ppm, VCM 6.0** ppm,- VCM
3.7** ppm, VCM
Source
Employee overexposed while disconnecting and unplugging a lip seal line on D-300 reactor seal.
Employee overexposed while changing VCM filter pack filters.
Employee performed his regular job of reactor operator. No specific cause of his over exposure has been identified.
The employee did not perform his regular job of reactor operator. Instead, he was assigned to the tasks of painting handrails at the east incincerator and assisting electronics with small breaker labeling in the V-ll dryer area, No specific cause for his over exposure has been identified.
ABDOO136626
Overexposures - Continued
Job Class Dryer Utility
Exposure 10.7* ppm, VCM
Yard Operator
2.5* ppm, VCM
General Mechanic General Mechanic General Mechanic Maintenance Supervisor
2.5* ppm, VCM 2.2* ppm, VCM 1.3** ppm, VCM 1.5** ppm, VCM
Maintenance Superintendent
1.4** ppm, VCM
Color Weigh Compounder
* Respiratory protection was ** Respiratory protection was not worn.
Source
Employee overexposed while monitoring blend tank levels in V-10 during pond resin reclaim.
Employee overexposed while assisting two general mechanics who replaced two Corken compressors at the VCM tank farm.
Employee overexposed while repairing a Corken compressor at the VCM tank farm.
Employee overexposed while blanking out 904 VCM recovery compressor.
Employee overexposed while changing a seal on D-300.
The employee spent approximately five minutes working near the new vinyl unit dump Sweco and approximately two minutes near the old vinyl PVC tank. The specific cause of his over exposure has not been identified.
Employee performed his regular job of maintenance superintendent, which took him to all parts of thte plant throughout the work period. No specific cause for his overexposure has been identified.
Employee performed his regular job of color weighup, handling Halbase 100EP and Cyastab 988. No specific cause of his over exposure has been identified.
ABDOO136627
I. H. MO. REPORT ITEMS - MAY
VCM Area Sampling
l
A second set of four VCM area samples were taken in the bio-disc water treatment area, using. REAL "Minimonitors". Wind velocity ranged from 0 to 5 miles per hour, direction being from north to south. Sampling time was eight hours.
This set of sample results agrees with the one in April, both demonstrating the effectiveness of the recently installed ventilation exhaust blowers in reducing VCM levels. Similar measurements taken during 1983 showed results averaging 19.9 ppm and ranging from 0.6 to 87.9 ppm, VCM.
Sample Location
Result - ppm, VCM 1st Set (April, 1984) 2nd Set (May, 1984)
Just north of middle bio-disc hut
0.2
0.1
West side of middle bio-disc hut
0.1
0.2
Just south of middle bio-disc hut
0.2
0.1
West side of east bio-disc hut
0.1
0.1
Area Ventilation Checks
The second quarter check of lab and compound ventilation hood velocities and flow rates was completed. The results were reported using a new format, which shows the results of the previous check.
Respiratory Protection Plant Breathing Air System
*
'
"
Several repairs of the breathing air system were made, including replacement of sections of split pipe and faulty pressure regulators. The system is now operating correctly.
VCM Cannister Gas Masks
Removal of VCM cannister gas masks from plant service was completed.
Noise
The report on the plant noise survey conducted on April 10-11, 1984, by the Medical Department was received from them during May. The annual Noise Control Report and Plan was written, using the results from the Medical Department survey, and submitted for review.
ABDOO136628
GMD Systems, Inc, Passive Monitor The second phase of the evaluation of the passive, VCM monitor marketed by GMD Systems, Inc. was completed. The results of the lab-based reproducibility studies will be reported by D. S. Cox, Manufacturing Chemist. Changeover from use of the REAL "Miniraonitor" to that of the GMD device is anticipated, pending the reported results. Equipment Calibration The second quarter calibration of the precision rotameter used to measure Bendix BDX 44 air pump flowrates was completed using a large ,fbubble tube" as a primary standard. No significant drift was seen. Material Safety Data Sheets MSDS were reviewed by the Vinyl Department and the Maintenance Department. Three copies of each MSDS that pertain to the Vinyl Department will be issued to the Vinyl Operations Supervisor. The Maintenance Department will be issued a copy of nine MSDS to update their book.
cc: JF, CRM, DWH, PJK, LPS, WFH, CRS, RAF, RAM, AHS, JVU Tom Grumbles - Houston J. R. Drumwright, M.D. - Ponca City
%< PEL
VCM
ABDOO136629 ABERDEEN CHEMICAL PLANT CHEMICAL DOSIMETRY TRENDS
O
ca
wa ~ < I/J
19. 82-
3= 3> <m Wa O-- Zg 8T
S 2 54C; 3^, lW <~G% 6; i2-SV. 19 84