Document Vj9MKpNDv0JpJEr4KdKB74eK8
>
O DOg
a*rototrx. v #r(ToS\*Xw-*Monvi .*1 ot+tfftt
H ft ft O ft
ft r> -1
o
COMPANY CONFIDENTIAL
PLAINTIFF'S
exhibit
^Z(o'T^c^ar`
TRAN 006979
WATER PCB-SD0000041935
WATER PCB-SD0000041936
MONSANTO COMPANY Monsanto, Illinois
Messrs;
P. F. Noisier H. C. Carder M. F. Gibbs - Org. Res. II. F. Hubbard * Org. Res, l'roccfis Holders
September 20, 1966 Tentative Amendment No. "F"
TJT1.F.
Tentative Amendment No. "F" to the Standard Manufacturing Process for Aroclor (Dept. 246 - WGK) dated 7/20/64.
pBJFCTlVF
Produce improved quality Aroclor with activated bauxite (A12Oj) lrcaIntent.
_pkfsp;nt practicf
Distilled Aroclor is treated with activated atlapulgus clay for quality up*grading in one of two earth treating tanks followed by filtration to remove suspended solids before storage,
PROPOSKI) . PR9CF1)UR F
Substitute clay with "porocel", activated bauxite supplied by Minerals and Chemical Corp. , at levels sufficient to evaluate up-gradingperforinance. Porocel (20/60 and H 60 mesh) suspended with agitation and rccirculation in the existing earth treating system. Treated Aroclor will be filtered to remove suspended 6olids before storage.
jySTJKlCATJONL.
'
..
Anniston personnel have demonstrated (see Report 370-322-9 by^J.G. Bryant) exceptional up-grading performance in the laboratory by circulating Aroclor 1242 through a packed bauxite bed. Reported per formance is summarized below:
Spec, ificalion
Present Up-grading Performance @ Annist_on _____
Bauxite J<ab. 'Treating Performance
Resistivity (x 10% mm-cm)
Power Factor @ 100*C b 1 KC @ 100'C b 60 cps
Thermal Chemical Chlorides, ppm
Wcstinghousc Stability, ppm
Hydrolysis Stability, ppm
900 0.2 2.0 0.3 0.7 0.2
44.000
0. 02 *
0.03 * 0.07 0. 18 0. 04
* Exceeding Sensitivity of Measuring Instrument.
TRAN 006981
COMPANY co nfidential
WATER PCB-SD0000041937
2
JUSTIFICATION^ (Cont'd. )
Monsanto can very economically defend its unique marketing position if such performance can be demonstrated on a plant scale.
TIMING .
This amendment will be initialed after Anniston has successfully demonstrated a similar amendment and at lime consistent with normal production schedules,
SAKFTY
Aluminum oxides have been in contact with Aroclors for more than two ycar6 in storage units with no difficulties. Because of this, and laboratory work with bauxite t realment, present safely considerations are believed to be adequate. .
KXTKNT OF UKMONSTRjmON.
\
Up to 40 batches of Aroclor 1242 (2, 000 gal, /batch) will be processed resulting in a maximum of 800, 000 lbs. of product which will be used in non-electrica 1 applications.
: Prepared by:/^^T.
Cliff Woodward
Reviewed By:
Approved By:
cA bka+S..
6 &. C4
...../0~ll -66
Div, Research Group Reader Date
Production Supervisor t-
I)a t (
- . L (Tj>>
Mgr. of Research
III,--
' J Prod. Gen. Superi ntendciil Dale
Research Safely Review Com mi t lee
Ac Ap>tuyTr
/oAf/t (,
Pi. Process Res. Grc(5Jp' Leader'Pate
/v, )px $/)_____ __ / Pi) <*(* /
Gen. St|f/. Tech. Services Dale
____
______
-./AA<
Technical~y>rocIuction"Mina.geT Dili e
company
confidential
TRAN 006982
WATER PCB-SD0000041938
MONSANTO COMPANY ORGANIC CHEMECAIS DJVESEON
STANDARD MANUFACTURE NG PROCESS FOR AROCLORS - DEPARTMENT 246
****###***
Supersedes: Standard Manufacturing Process for the ' Manufacture of Aroclors, Department 246 Dated July 20, 1964 and aE 1 amendments.
rrcpared by;
D, E. Harris
Approved by:
General Superintendent'
"Research
Product! oh' Ft'.!"'.
Date; loj\ A af
COPY 11
of
This process Is the property of Monsanto Company and the rccipJcnt Js
responsible for its safekeeping. It contains confidential information of Monsanto Company which must not be reproduced, revealed to unauthorised persons or Bent outside the company without proper authorization. Either retain in a Becure file or r*eturn to the Standard Documents Dept,
COMPANY CONFIDENTIAL
TRAN 006983
WATER PCB-SD0000041939
D3 STK1PUT1CN SHEET
Technical Information Center Technical Information Center Central Reports Technical Production Manager Production General Superintendent Production Supervisor TSD Group LeaderPlant Research 1J brary Extra Extra Ex tra Kx tra Iianna Danna
Company . CONFIDENTIAL
TRAN 006984
WATER PCB-SD0000041940
AMKNDING RECORD SHKET
COMPANY CONFIDENTIAL
TRAN 006985
WATER PCB-SD0000041941
SECTION I SECTION 13
SECTION 13 3
&KCTI ON 3 V
APPENDIX A APPENDIX B APPEND! X C APPEND! X D APPENDIX E APPENDIX F APPENDIX Q APPENDIX H APPENDIX 3 APPEND!X J APPEND]X K APPENDIX L APPENDIX M APPENDIX N
TABLE 0]'* CONTENTS
INDEX
SYNOPSIS OE PROCESS
FTX)W sheets
A'! CHIiORINAT]ON REACTION STEP R. AERATION AND D1STIIJ.AT10N C'. B].ENDING, PIJ/PRATI ON AND STORAGE
PAGE
I-?
3
3A 3B 3C
PROCESS IN DETAIL A . NOMENCLATURE AND BATCH DATA B. CHI .OKI NAT3 ON REACTION STEP C. AERATION AND DISTILLATION D. BLENDING, P11/TRAT3 ON AND STORAGE E. BY-PRODUCT HYDROGEN CHI/0R1DF,
6
7
l8
COMMENTS ON PROCESS A. CHLORINATION STEP B. AERATION & DISTILLATION C. BLENDING & FILTRATION
D. GENERAL
9 - II 11
1?
EQUIPMENT LIST
FINISHED GOODS AND RAW MATERIAL SPECIFICATIONS
PHYSICAL AND CHKM3 CAT. DATA
13-?I 2?'
23
UTILITIES PERSONNEL
2*1-?0 29-30
PACKAGING AND SHIPPING
MATERIAL BATANCE
ATMOSPHERIC DISCHARGE AND WASTE DISPOSAL
PROCESS CONTROL PROCEDURES
31-3? 33-35 36
37
SAFETY AND TOXICITY DATA
COMPANY
BACKGROUND INFORMATION CONFIDENTIAL ^
TIME CYCLES QUALITY CONSIDERATIONS
. 46 D7-5>3
MI SCELI.ANKOUS
TRAN 006986
5*1-57
WATER PCB-SD0000041942
3.
Dept. ?46 - Process Ipscrlptjon
AROCLOK
SECT! 0N__3
SY Npi'S]_S_OP_ PROCESS
Aroclor 1b a trade name uaed to designate chlorination products of
biphenyl, biphenyl high boilers, or mixtures of the two. I-iquid
Aroclors are produced by chlorinating biphenyl to 2], y?, 42, 48,
i>4, 60, and 620 chlorine oontent. Chlorination above 630 yields a
solid product at normal temperatures. Liquid Aroclors are identified
by four digi-t numbers; The last two digit numbers represent the
chlorine content (percentage by weight), and the first two .numbers
represent the Aroclor condition (crude or distilled).- Crude Aroclors
start wi th the prefix 11 whereas distilled Aroclors start with the
'prefix 12. For example, Aroclor 1242 is a distilled chlorinated
biphenyl containing h20 chlorine.
`
The first process step in the manufacture of Aroclors is a chlorina tion reaction. Biphenyl ( 0-0) and chlorine (Clg) gas in.the presence of a Ferric Chloride (FeClj) catalyst are reacted to form a chlorinated aromatic compound. Hydrogen chloride (HC1) gas is liberated during this reaction and piped to the muriatic acid department. The exact chemistry of biphenyl chlorination is unknown. Many isomers are formed. A schematic representation of
biphenyl chlorination is as follows:
BIPHENYL M.W. = 15*J
CHLORINE M.W. = 71
AROCLOR
HYDROGEN
M.W.= (2^1 .1- CHLORIDE
399-6) M.W. = 36.
COMPANY
confidential
TRAN 006987
WATER PCB-SD0000041943
Dept. 246 - process De script Jon
AROCLOR
SKCT1 ON_l
SYNOPSIS OF PROCKSS (Cont' d . )
The second process step is the aeration and distillation or the crude
Aroclor. Dry air is blown through the crude Aroolor for a period or
two hours or more. Aeration removes most of the free hydrogen '
chloride. Distillation of crude Aroclofs is done under vacuum auto
matically controlled with the controller pre-set between 30-50 mm Hg.
ags, to obtain the best performance. Distillation of crude Aroolor
separates residue, lime, ferrio chloride, and tars from the finished
product.
`
' The third:process step includes blending, filtration, and storage of Aroclors. Approximately 0.1 - 0.2# by weight of Attapulgus earth is added to the distilled Aroclor. The mixture Is agitated and filtered to the finished product tank. The purpose of the Attapulgus earth . is to absorb moisture and chloride ion to improve the electrical properties of the Aroclor. During the filtration of distilled Aroclor, 2 - 16 o?,. samples of the finished product are taken to the laboratory for control analyses. If the control analyses pass specifications, the batch is transferred to a storage tank.
This process description will describe the production of Aroclors 1242, 1248, 125*1, 126o, 125*1 xylene mix, and 1262.
COMPANY
confidential
TRAN 006988
WATER PCB-SD0000041944
Dept. ?l|_6 Process Description ARpCLOR SKCT3ON 13
FLOW SHKKTS This section containB the following flow sheets. 1. Complete process flow sheet. 2. Chlorination Reaction Step 3. Aeratjon and Distillation k . Blending, Filtration and Storage.
(
3.
COMPANY CONFIDENTIAL
TRAN 006989
WATER PCB-SD0000041945
WATER PCB-SD0000041946
3b WATER PCB-SD0000041947
TRAN 006992
WATER PCB-SD0000041948
( Dept. 2hS - Process Description
4.
AKOC] >OR
8KCTJ ON J 32
PH OC]-:SS _ 1 N
L
A . NOMKNCIjATUHK AND BATCH DATA
COMPANY CONFIDENTIAL
Aroclor js a trade name used to designate chlorination products or
biphenyl, biphenyl high boilers, or a mixture of the two. The physi cal properties vary from light free flowing liquids to crystalline and non-crystalline solids, depending upon the degree of chlorina
tion and the composition of the raw materials. Chlorinated biphenyl yields a liquid product of increasing viscosity up to and including
63# chlorine. Chlorination above 63$ yields a solid product at . normal temperatures.
A numerical system of nomenclature, consisting of four digits, has
been developed for identifying the various AroclorB. The first digit
denotes the aromatic raw material used in the chlorination step.
The figure 1 -- indicates 100# technical grade biphenyl. ' The
second digit denotes whether or not the product is distilled. The
J
figure -1 -- indicates undistilled product, and the figure -2 - indicates a distilled product. The last two digits of the nomen
clature system denote the approximate percentage by weight of
chlorine contained in the finished product. For example, Aroclor
1242 is a distilled chlorinated biphenyl containing 42# chlorine.
Manufacture of all liquid Aroclors is essentially the same. Da trh
data are listed below:
'
Type Aroclor
1242
1248
1234
1260
1262
Diphenyl Charge
4000//
4000// 4000//
.4000//
4 000//
Chlorination Time
6 Hrs.
8 Hrs. 10 Hrs. 12 Hrs. 14 Hrs.
Spec! fic Gravity of Crude
1.349-58 1.4 08- 18 1.498-508 1.558-69 1 .580-9C at 6f?C at 63 C at 65C at 90C at 90C
Weight of Crude Datch
6670//-.
7580//
8450//
9600//
10,600//
Weight of Distilled
Datch
6400//
7200// 8o4o//
9100//
9850//
Tons of 100# by-product
HC1 per Datch
1.94
1.43
2.27
2.4?
2.70
(
Theoretical Molecular
Weight
257 .7
292.6
326.6
369.5
393.6
TRAN 006993
WATER PCB-SD0000041949
l. Dept. ?*|6 - Process Description
AHOCJOK
SECT! ON 111 PKOCKSS ]N DKTA3h
1* CliJ flll] NATION RKACT1 ON STEP
COMPANY CONFIDENTIAL
Chlorination of biphenyl is the only process step where a chemical reaction takes place. All other Aroclor process operations are mechanical. The starting raw materials for Aroclor production are
biphenyl and chlorine gas.
HJ phenyl is received in 8, OOQ 10,000, and 20,000 gallon tank cars from Anniston, Alabama. The biphenyl in the tank cars is a solid" mass because the crystallizing point of biphenyl is 68.7C. Steam must be applied to the tank car coils to melt the biphenyl. It is
necessary to melt a vent hole through the solid mass of biphenyl by insertion of a hairpin steam coil through the tank car dome before applying steam to the tank car coils. The vent hole avoids a press ure build-up in the bottom of the tank car and possible damage to
the car. When the biphenyl, is completely melted, it is sampled for identification and unloaded through the tank car standpipe by air
pressure to the 23,000 gallon storage tank. Dry air is used to unload the biphenyl cars to keep the biphenyl, free from moisture.
The flash point of biphenyl is 112C.
Chlorine gas is received in a 4 inch pipeline from the chlorine .. department. In order to facilitate operation of the chlorine liquefaction system, "enift" gas with a purity of 75-93# (the remain der being air) is transferred from the chlorine department. The normal pressure of the chlorine gas in Department 246 is 20-29 psig.
Biphenyl (*1000//) is charged into each chlorinator from the measuring
tank. The biphenyl charge in the measuring tank can be regulated by valves at different overflow levelB. The four overflow levels on the measuring tank permit biphenyl charges of 1800, 2800, 3600, and 4000 pounds. Two pounds of anhydrous ferric chloride are charged to the chlorinators after the biphenyl is charged.
TRAN 0 0 6 9 9 4
Chlorination is carried out in five chlorinators. Each chlorinator 1b three feet in diameter by sixteen feet high, and constructed of
Btecl. Four of the chlorinatorB has a catalyBt bed which is 2'3" in diameter by 8 feet high. The catalyst bed consists of-L-l/2 inch diameter by 2 inches long pieces of pipe which are similar in nature to raschig rings. The fifth chlorinator is identical to the other chlorinators except that it has no catalyst basket. The catalyst bed? in four of the chlorinators will be removed as they fail mechanically
After charging the chlorinator, circulation of the charge is started before the chlorine feed is begun to maintain an even distribution
of the ferric chloride catalyst. The temperature of the biphenyl is 110C-120C at the start of the chlorination. The chlorinator mass reaches l?0c-130c within 30 minuteB after the biphenyl is charged.
WATER PCB-SD0000041950
( |?cPVj_ 2^6 - _Process Dcscri ptlon AKOCJ/OK SECTION^] P]{OCh^SS 3 ]LJ>KTA3L_ (Cont *d . )
6.
COMPANY CONFIDENTIAL
B. Chlorine gas from the chlorine department passes through a Brink
mist eliminator and evaporator before entering the chlorlnator.
The ml st eliminator removes most of the Impurities, and the evapora
tor Insures that all of the chlorine is gaseous.
`
The purified chlorine gas Is admitted to the bottom of the chlorlna tor through a distributor plate (sparger) and passes through the catalyst bed. A chlorlnator temperature less than 170C Is main tained during the chlorination reaction to avoid sublimation arid, subsequent condensation of biphenyl in the off-gas system. Kach chlorlnator Is equipped with a Brink mist eliminator. The purpose of the off-gas mist eliminators is to trap entrained particles of
Aroclor and biphenyl.
The chlorination temperature in the chlorinators is controlled by
automatic control of the air flow through the externa] alr-coolcd
^ heat exchanger. The chlorination temperature must be at least
1?0C 30 minutes after the start of the batch and no more than 170 C
to finish off a batch. The normal batch temperature is 150C. The
louvers of the air-cooled heat exchanger located in the external
circulating line of the chlorlnator are controlled such that the
batch temperature will remain between 120C and 170C. The
temperature of the batch is recorded at four different points:
(l) in the center of the chlorlnator, (2) just above the chlorine
sparger in the chlorlnator, (3) at the discharge of the chlorlnator
pump, and (4) at the discharge of the air-cooled heat exchanger.
Point 1 is alarmed for high temperatures, and point *1 is alarmed for
low temperatures. As a safety device, a high temperature sensing
element is positioned at point 2 to shut off the chlorine gas
flow if the reaction temperature exceeds 190C.
.
The batches are continuously circulated at an average flow rate of 200-220 GPM from the bottom of the chlorlnator, up through the air cooled heat exchanger, and back into the top of the chlorlnator over the catalyst bed. Chlorine feed,up to a maximum of 1500 pounds per hour is fed into each chlorlnator through a flow recorder-integrator
which is alarmed.
Progress of the chlorination reaction is checked periodically as needed after 80$6 chlorination as measured by the recorder-inte
grator ,
` The degree of chlorination is measured by determining the specific gravity of a sample taken from the circulating line. More frequent gravity checks are made when approaching the end of chlorination.
TAAN 006995
WATER PCB-SD0000041951
Dcjpt._ 2M6 - Process Description
7.
mooim
SKCTipNlll QCKSS_ 1_N_ DKTA1L
COMPANY CONFIDENTIAL
C. AKKAT10N AN1) D1ST11JAT1 ON
When chlorination is complete, the crude Aroclor is pumped into number two blow tank (capacity 2000 gallons). The crude Aroclor is aerated in the i/2 blow tank for two hours or more with dry air. Aeration of crude Aroclor removes most of the free hydrogen chloride.
Crude aerated Aroclor is transferred from the i/2 blow tank to the ill blow tank. The i/l blow tank is used as a crude Aroclor feed tank_ to the stills. Crude aerated Aroclor is transferred from the //I blow tank to vacuum stills through an automatic control valve which maintains a constant level in the stills. Under normal conditions the automatic feed to the stills is shut off after distilling bout 75.000 pounds of Aroclor. (This is equivalent to filling 7 still
receivers). The still is then boiled down until a temperature
difference between the still coil outlet and vapor temperature i approaches ^0C. At this point distillation is discontinued and
all but a small heel of the residue is drawn off to drums and discarded or sold as Montar. The still is immediately recharged with crude Aroclor and 200 pounds of lime 1b added directly to the still
pot. Hydrated lime is received in 50 pound bags. The lime neutral!z es any residual HC1 in the still liquor and prevents sublimation of ferric chloride during the distillation period. Distillation of Aroclops is done under vacuum automatically controlled. The best performance is obtained at a steady vacuum which can be pre-set by a controller between 30-50 mm Hg. Abs.
Natural gas is used to heat the coil of the Aroclor still furnaces.
The pressure of the gas.burner (eclipse, st. 108.5, 2", //668, 600.000 BTU/hr.) is adjusted as needed for production requirements.
The normal gas pressure ^Ls 3-5 psig.
D. HI.KND1NG, FILTRATION, AND STORAGE)
`
When the still receiver is filled, the distilled Aroclor is pumped to the blend tank (2000 gallon capacity). After two fillings of the receiver tank have been pumped to the blend tank, approximately *J0 pounds of attapulgus earth is added to the diBtillcd 1242 Arc:lor.
All other Aroclors are earth-treated with 20 pounds of Attopulgus earth. Regular Attapulgus earth is received in 50 pound bags. The mixture is agitated and filtered to the finished product tank (2000 gallon capacity) through a 36 inch stainless steel Sparkler Kilter. ( The attapulgus earth is roasted at 250C for a minimum of four hours in a Grieve-Hcndry drying oven before addition to the blend tank. The purpose of earth heat treatment i s to remove any moisture
in the earth and activate it. The attapulgus earth absorbs water and ionic impurities. This improves the electrical-quality properties of the Aroclor.
TRAN 006996
WATER PCB-SD0000041952
8.
])cpi. 2^_6 - I'roccbs Dcscrjptjon
AR0C1/DR
SECTION 33 3 ' PROCESS IN DETAIL
D. BI-Km)_LNa^_Pll.TR_AT_3 0N_ AND STORAGE (Cont d.)
COMPANY CONFIDENTIAL
The fJ Her press is cleaned after about 5~7 batches or as needed. During the filtration, 2-16 oz. samples are taken to the laboratory for control ana3yses. If the control analyses pass spccificatjons, the batch is transferred from the product tank to a storage tank. After several batches have accumulated in the storage tank,, the con tents of the tank are mixed, and composite samples are taken for lot analyses.
Three underground (15,000 gallon) tanks and five above-surface (each 20,000 gallons) are available for storage of the finished products.
The blend tanks, finished product tanks, and Aroclor 12*12 and l?5*l storage tanks are blanketed with nitrogen. The pressure of the nitrogen gas is 10 psig. Nitrogen blanketing maintains the clectrica properties of the Aroclors.
The Aroclors from the storage tanks are drummed, pumped to tank cars,
pumped to tank trucks, or transferred to Department A-2^6 or h-?*i6 mixing tanks for the production of Pyranols, Inerteens, or Fydraul A-200.
Ditches of Aroclor 125*l-mix are mixed in the //I blend tank. This operation consists of a mix of 10# xylene and 90# Aroclor l?5*i Xylene is received in 55 gallon drums. The flash point of xylene is
85K. Mixing, sampling and drumming of 125**-mix is accomplished directly from the blend tanks. After the blending operation, the blond tank must be cleaned. The bottom outlet of the tank is opened
and the tank is cleaned out with live steam and then blown with air.
K. DY-rnODUCT HYDROGEN CHLORIDE)
TRAN 00699 7
The by-product hydrogen chloride from the chlorinavors is collected in a common pipeline header and flows to the central HC3 absorption
unit to manufacture Muriatic Acid in Department F-218. If Department F-218 is unable to handle the off-gas, it may be sewered at Depart
ment 2*i6 by passing through a Haveg S-K drowning Jet. The removal of HC1 from the off-gas concentrates the Original quantity of hydrogen and air to a point well within the explosive limit.
Therefore, it is essential to either dilute this gas going up the
( vent Btack or increase its velocity past the flame propogati on rate (15 ft/sec). This is accomplished by introducing a sufficient quantity of steam into the vent stack.
To remove vaporized .and entrained impurities in the HC1 from the chlorinators, the gas passes through a condenser and mist eliminator. The entrained liquid, which is primarily biphenyl, is sewered.
WATER PCB-SD0000041953
9.
Dcpt_. 2kG - Process Desoriptlon
AHOCJ^OH
5]<:CT]_0N.J V COMMI^NT.S _ON PROCESS C111 OH3 NAT3QN STEP
COMPANY CONFIDENTIAL
A. RAW__MATER3 a;, YD K] J)S
Biphenyl and chlorine are reacted to form a chlorinated biphenyl called Aroclor. The yields on biphenyl and chlorine vary with the type of Aroelors produced. Each particular type of Aroclor has its own standard yield factors. Yields are not reported for the indivi dual type on Aroclor each month. An average yield is reported . monthly and compared with standard and theoretical yields which arc calculated according to the quantities of the various Aroelors produced during the month.
Standard and theoretical conversion factors used in computing chlorine and biphenyl yields are listed below.
STANDARD CONVERSION FACTORS
AROCIOK
______ _
1242 1248 1294 ]?6o 126? 123? 12[>4 Xylene
CHJORJNE H/il Product
.9032 1.0323 1.6130 1.2903 1.3333 0.6882 3.0492
.
B1 PHENYl. jj/jj Pnoduc t
0.6l80 0.9980 0.4978 0.4368 0.4163 O.7216 0.4480
THEORETICAI. CONVERSION FACTORS
AROCIOK . _ _ - . -
'
3.132-1232 1142-1242 1348-1248 1194-1294
3360-3260 1362-1262
1294-10# Xylene
CHDORJNK H/H Product
0.6400 0.8400 0.9600 1.0800 1.2000 1.2400 0.9720
MPHENYL Product
0.6891 0.9919 0.9397 0.4794 0.4147 0.3976 0.4279
TRAN 006998
WATER PCB-SD0000041954
I Depi^ Pb6 - l'roccss Description
1 0.
AROC10R
SKCT3 0N 3 V COMMKNTS ON PROCESS C]]]/)RiNATiON_S2'KP
COMPANY CONFIDENTIAL
D. AP_AC_1TY
The monthly production capacity of Department 2^6 is 2, *100,000 pounds of Aroclors on a 7 day per week basis. The capacity of ihc chlorinators is a function of the following variables.
1. Batch Cooling Rate - Chlorination of biphenyl is an exothermic rcacti oh'whTch produces 530 BTU's per pound of chlorine gas
undergoing a reaction with biphenyl. Biphenyl can be chlorinaU as fast as- the exothermic heat can be removed from the batch anc maintain a batch temperature of 150C.
2. Chlorine Flow Rate - The reaction time decreases as the chlorine Tlow rate Increases. The chlorine flow rate is approximately 1000 pounds per hour per chlorinator. A maximum chlorine flow
( rate of 1500 pounds per hour per chlorinator can be attained if desired. The concentration of chlorine in the "snift" gas is another factor controlling the rate of chlorination.
3. Catalyst - The chlorination rate increases when ferric chloride catalyst is added to the charge. The best results arc obtained when the biphenyl charge contains .05% ferric chloride eala'iyat
C. QUALITY
Some of the factors which affect Aroclor quality are as follows:
1. Temperature - According to research experimental results, the clilor3nator temperature must be greater than 1?0C at the beginning of the chlorination reaction to produce stable
Aroclors.
2. Catalyst - Good contact is necessary to produce stable Aroclors Tt"3s suspected that agitation and circulation of the reactants improve the effectiveness of the catalyst. The catalyst is als< responsible for the chlorine positioning on the biphenyl moleeu Ferric chloride catalyst may be responsible for proch/cing the desired end product. Results of research work concerning
catalyst and isomeric distribution arc given in Appendix N.
(
TRAN 006999
WATER PCB-SD0000041955
Dcpt_. ?^l6_J'rp_ce_ss Dcscri ptlon
11.
AHOCJjOH
SECTION IV
C_OMMlvNTS_ ON PROCESS CHI OH3 NAT] ON_S]EP C QUAlOTy JCont'd. )
COMPANY CONFIDENTIAL
3, Raw Material Pur] ty - The purity of raw materials can affect the quality of'Arodors both directly and indirectly. In a direct manner, impurities which are ionic lessen the resistivity of
ArocDors. Distillation of crude Aroclor separates most of the ionic impurities; however, minute impurities can be carried over to the receiver tanks. Attapulgus earth can remove the remain ing impurities in most instances. If any ionic impurities remain after the earth treatment, the resistivity of the Aroclors will be low because such impurities wil] conduct electricity even in minute concentrations.
In an indirect sense, impurities such as sulfates in the chlorine gas, will poison the ferric chloride catalyst and thus unstable Aroclors will be produced. The chemistry and mechanism of the catalyst poisoning arc not known for certain.
4. Catalyst Basket - During the latter part of 1965>, the catalyst fjaskfct wais removed from one of the five chlori nators. The materia] produced in the chlorinator without the catalyst bas ket analyzed as normal material. This material was used by a customer with satisfactory results.
The catalyst baskets may be removed from the other four chlorinators as they fail. The only restriction on material made without the catalyst basket is that it will not be sold to General Electric, or Westinghouse.
AERATION AN1) DISTILLATION
TRAN 007000
Steam is not applied to the coils of the blow tanks when aerating Aroclors 1142 and 11^8. This prevents the loss of Aroclor vapors. Eighty psig steam may be applied to the coils when aerating other Aroclors. High moiBturc may be removed effectively by blowing the
crude Aroclor with dry air.
Vacuum trouble on the stills is usually caused by flashing of product, air leaks, plugged vacuum lineB, or improper functioning of the vacuum Jets.
Flashing can usually be stopped by operating the still at a slower rate or increasing the flow of cooling water to the vapor condenser.
Vacuum trouble can be traced systematically from the Jets and usually i solatcd.
High color and entrainment will result from overheating (around ?'jC
above normal distillation temperature) Aroclor, faulty operation of
the distillation step, or boiling down thestill too far. (Tars
will carry over). The "tail-end" still fraction (tars) is a
........ .. . - / .... -J -VI.
1
WATER PCB-SD0000041956
1?.
( Dept, 246 - process Description
AROCLOR SECT]ON IV
COMMENTS ON PROCESS
COMPANY CONFIDENTIAL
RiENDDNG ANJ^ FILTRATION
Attapulgus Earth Is added In the blend tanks to reduce moisture and Inorganic chlorides as well as Improve electrical properties. ]f batches do not meet specification (See Appendix B), redi sti llation
may be necessary.
The Attapulgus Earth Is roasted for 4 hours at 250C before addition to the blend tanks when earth treating Aroclor 1242.
(
(
TRAN 007001
WATER PCB-SD0000041957
Dept. J>46 -_ Process Description
13.
AKOCIDR AP]'KN]);_X_A_
KQUJ PMKNJ' LIST
COMPANY CONFIDENTIAL
Tills section contains an equipment list with each piece of equip
ment listed by Item numbers In a consecutive numerical sequence. Ml seellancouB Items of Dept. 246 such as Instruments have not been assigned Item numbers. Equipment without Item numbers Is not
Included in this equipment list. All equipment of Dept. 246 will have Item numbers assigned sometime in the future. This equipment list should be expanded bb additional Item numbers are assigned.
3 tern Equipment No. Name
Equipment Number
Dcscription
3 01 Diphenyl Transfer 19-0582 Taber vertical submerged cent,
Pump
66-3930 pump, size C-3, 22" inlet,
2" outlet. Connection bronze
except shaft which is monel.
Motor is 3 HP, 1800 RPM.
0
1--i
CVJ CVJ
1
I--1
CVJ
10? Diphenyl Storage Tank:
Tank purchased from Rogers and Wrigler. Capacity is ?5,ooo
gallons. 10' 6" Dia. x 4O'6" long. 3/8" plate she]]. Design pressure 1b 50 psi .
3 03 Diphenyl Head Tank
21-0767 16-7225
Tank made by Graver. Dwg.
C-799. Steel tank 4>6" ID x 5'6" str. side, dished heads, shell 3/8", top head 3/8". and bottom head 3/4" with l/?'1 jacket over it and ending 9" op on tank side. Welded throughout. Test of tank is 60if and jacket is
105f/ hydro, pressure. Mixer is Mlxco Model N33G75.. gear driven propeller'. Motor is 4'io/3/6o
TEFC, 1725 RPM.
Oil Diphenyl Feed
66-7224
Durco Horiz. Cent, pump, 2" inlet, 2" outlet. Cap. 300 GPM Motor is 7i HP, 1760 RPM
3 05 Chlorinator if 1
21-3261
Tank made by Nooter. Dwg. K-8O0.
3' ID x 16* long, with pig. head.
Shell 3/8" and head 7/36^ thick,
3/36" Jacket over lower half of
tank.
1.
loG Chlorinator #2
21-3245 Same as Item No. 105.
TRAN 007002
WATER PCB-SD0000041958
Dcpt^ ?4_6 Process Description
3 4.
AKOCJ^OR
APPENDIX A
3 tern Equipment No. Name
EQUIPMENT 1JST (Cont'd , )
Equipment Number
COMPANY CONFIDENTIAL
Deseri plJ_on_
3 07 Ch3ori.nator //3
23-3251 Tank made by Leader 3ron Works. Otherwise, same as Item No. 3 05.
308 Chlorinator #4
23-1283 Same as Item No. 307.
109 Ch3orinator #5
21-1432 Same as Item No. 307
330 //] Mist E3iminator 15-0581 Tank made of carbon stcc3. Element made of carbon stee3. Design pressure
is 50 psig. and design tempcraturc is
300F.
133 //2 Mist Eliminator 15-0582 Same as Item No. 110,
31? //3 Mist E3iminator 15-0583 Same as Item No. 110.
133 //4 Mist Eliminator 15-0584 Same as Item No. 130. 13 4 //5 Mist Eliminator 15-0586 Same as Item No. 110.
315 Chlorine Mist Elim. 21-4o4 2 Tank made by A3pha. Carbon steel construction. Coded tank. Element 316 stainless steel. 35" dia., glass fiber inverted type. Design pressure is 50 psig and design temps l^aturc is
300F.
3 36 Ch3orine Vaporizer 38-5^87 Chlorine vaporizer made by Armstrong Company. 8-5/8" OD x 13' long. Carbon Btecl construction. Chlorine
side steel designed for ?50 psig* at 400E. Steam side' designed for IOC psig at 400P.
3 20 Knockout
.l
Steel vertical 60 gal. tank.
323 Ch3orinator //I Pump
19-;I305 66-8109
Durco Mark 13 horiz. cent. pump. Inlet is 3" and outlet is 2 , ductile iron, with Duramctallic seal and Manzel lubricator. Rate is POO Gl'M at ' static head Sp. Gr. of 1.5. Motor is 10 HP, 1800 RPM.
TRAN 007003
WATER PCB-SD0000041959
Dept. 2*16 - ProceBS Description
15.
AR0C3.0R
APPENDIX A
1 tern Equipment No^_ __ Name___
EQUIPMENT LIST (Cont1'd.)
Equipment Number
COMPANY CONFIDENTIAL
Do scri pti on
12? Chlorinator i/2 Pump
19-4306 Same as Item No. 123 66-8110
1?3 Chlorinator H3 Pump
l.?4 Chlorinator i/}1 Pu.mp
1?5 Chlorinator Hb I*ump
19-^307 66-8111
19-4308 66-8112
69-3892 66-6509
Same as Item No. 121 Same as 3 tan No. 123 Same as Item No. 121.
3 26 Flow Tank i/2
21-2086
Tank made by Graver. IXvg. K-863, 71 x 7' Btr. Bides, dished heads l/2",
shell 3/8"/ 5 turn coil of 2" pipe supported on brackets welded.
1?7 Blow Tank i/2 Pump
66-2956 69-0577
Taber horiz. cent. pump. Typc 3.-2. 2| " x 2". Semi-steel with monel shaf and water Jacketed stuff!np, box. At 20* static head, rate ! s 80 GPM, 1.5 So. Gr. at 500F. Motor is 3 HP, I8OO RPM.
1?8
.f
Air Dryer
14-0104
Anders Iykens Corp. Air dehydrator. Two code welded tanks filled wi th 55 lbs. activated alumina. Dwg. #6456.
3 ?9 ' -mt%ooV\ r Tank
' H//li Pump
19-0629 Same as 3tern No. 1?7.
66-9080
13$* , Sti 13. //I
20-0043
Vacuum still purchased from Graver.
Dwg. C-809. Size 6' Dia. x 3 *6" 3g.
on str. side,
she]], dished head
5/8". 60# hydro, pressure test.
133/, F*urnaoe //I
27-0045
Steel heater furnace. Steel 6hc3 3
3/16" x 3'9" dia. x 4' 10" 3g. lined
with insulating fire brick. One coil
2" xHy pipe, 1? turns formed into a 2
dia. coil with spare blocks and legs.
Dwg. E-886.
0
13? Still //I Pump
19-0594
Taber vert. sub. cent. pump, type I.-2 Casing, yoke, and impeller made of steel. 2" inlet and 2" outlet. Length 7'9". Capacity is 75 0PM, static head 35S Sp. Gr. 3.8 at 700F
Motor is 5 HP, 1750 RPM
TRAN 007004
WATER PCB-SD0000041960
Dept. ^>46_- Process Description
16.
AKOCIOK
APPENDIX A
Item No.
Equipment Name
EQUIPMENT LIST (Conl'd.)
Ai ' Y
- confidential
Equlpment
Number
Description
133 StllD 7/2
20-0062
Vacuum stl]] purchased from Nooter.
Dwg. 694`1. 6* ]I) x 1.1'10" str. she] Interna] pipes, standard dished heads. Glass wool Insulation 3" with 1/2" finished coat.
134 Furnace #2 135 Stl]] //2 Pump
20-0066
66-1739 69-1277
Same as Item No. 133.
Taber vertical sub. cent. pump. Typo CI.-4, 2^ x 2", size 384. lump Is dynamo steel. Capacity Is 75 Gl'M at 25* static head, Sp. Gr. ].8,Mo tor Is 7i HP, 1750 RPM.
136 Condenser //I
38-0770
Heat exchanger made by Nooter. Dwg.
B-65I. 12" dla. 5' long having nineteen 2" OD 11 ga. mone] tubes, monel tube sheets, monel reducer, and carbon steel Jacket and back
up rings on flanges.
3 37 Condenser //?
38-1378
Same as Item No. 136.
130 Receiver Tank //I 21-0771 Vacuum receiver tank made by Nooter. Dwg. C-795. Size is 5'6" dla. x 5'6" str. side, 3/8" she]], 3/?" bottom and removable head. 2" 3
size xHy monel coil with 2" iri]et
and 1" outlet. 3 turns, 5' dla. along side and 3 turns spiral on bottom. 60// hydro, pressure
test on tank and 300// on coil.
3 39 Receiver Tank //2 21-1377 Tank made by Nooter. Dwg. C-795.
Same as item No. 138.
,
3*10 Receiver Pump //] 66-9067 Blackmcr pump. Type PA-501., bronze
69-0363
rotary pump, monel shaft, c.l.
base. Capacity 1 s 30 Gl'M, 1.65
Sp. Gr., 350 to 500E. Motor is
2 HP, 1750 RPM.
34] Receiver pump
66-5670 69-1258
Same as Item No. l40.
TRAN 007005
WATER PCB-SD0000041961
AHOCIOH
APPEND!X A
3 tern No,
p:qui pmcnt Name
EQUIPMENT LIST (cont'd.)
Equipment Number
COMPANY CONFIDENTIAL
poser jj>tj on
142 Blend Tank //I
21-0779
Tank made by Graver, ixvg. K-86?. Welded steel tank, 7' dia. x 7* high dished heads ", she33 3/8". A3 3 surfaces Bpraycd with .005" zinc then .003" tin. 2" xNy pipe coi 3 and supports. Case bronze stirrer and bronze shaft. Test of tank is
60// and coll is 300// hydro, pressure
343 Blend Tank #2
344 Blend Tank Bump
21-1399 66-0217.
19-1757 66-371o
Same as Item No. l42.
Taber Horlz. Centrifugal pump. 304 b.b. 2" x l " capacity 60 GPM, 100' head. Motor is 10.0 HP, 3 800 KPM.
34!) 36" Sparkler Fi Iter
15-0238
Filter made by Sparkler Mfg. Co.,
33-P-12 horizontal plate filter. Type 304 b.s. Jacket tested for pressure of 30 psi.
146 Finished
23-0780
Filtrate receiver tank. Dwg. E-862.
Product Tank 7/3
Same as Item No. 342.
147 finished Product 21-1400 Tank made by Nootcr. Otherwise,
Tank //2
same as Item No. 142.
348
S torace Tank f/3
21-0768
Tank made by Graver. Dwc, C-6O9.
Horizontal steel, 10' dia. x ?6' lon^
on str. side, dished heads, shell
", head l/l6". Test of tank is 60//
and coil is 300// hydro, pressure.
All colls, supports, inside surface
sprayed with .005" 2inc and . 0t3"
tin.
349 Storage Transfer 19-0585 Taber Vert. Sub. Pump. Dwg. A-387*
Tump //3
66-0853
Type C-3) 2" x 2", C.3 . body,
length 13'6". Cap. 50 GPM. 60; stall*
head, Sp. Gr. 1.38 at 370F. Motor
is 3 HP, 1800 RPM.
3.90
Storace Tank //4
21-0769
Same as 3tern No. 148
Tank f/4
193 Storage Transfer 19-0584 Taber Vert. Sub. Pump Typc
Pump #4
66-1501
22" x 2". length ll'o". Cap 50
GPM at 40' static head. Motor is
3 HP, 1800 RPM.
TRAN 007006
WATER PCB-SD0000041962
^ rrocesb Description
18.
AR0C3OR
'KNJ )] X_A
1 tern No.
Equipment Name
co-vv.. ,
' EQUIPMENT^ IJ_ST (cont'd.) CONFIDENTIAL
Equlpment Number
Descrl ptl on
J5>2 Storage Tank 7/5
21-1310
Tank made by leader Iron Works. C-609. 10'OD x 26' long on Btr. shell. Same as Item No. 1*18 for other characteristics.
H53 Storage Transfer 19-0929 Same ae Item No. 151, except
IMmp i/b
66-O856
length is *1 '7".
15*1
Storage Tank //8
21-3526
Slpha tank 12*6" dla. x 22' high.
20,000 glllon storage capacity.
Aluminum constructed Dwg... TS-D-3011
355 Storage Transfer 19-3172 Durco pump, model WH2 Alloy constr.
Punip 1!0
66-2651
2" x 14", 8" Impeller, Cap. 160 GPM
at 55* head. Motor Is l\ 111', 17*10
RPM.
156
Storage Tank 7/7
21-2*10*1
Alpha tank. 13' 0D x 20' high.
Vertical tank, constructed of 3/8"
mild steel. Capacity Is 20,000 gals
yyf Storage Transfer 19-2077 Pump made by Dlackrncr. Mone] shaft,
Pump //7
66-1691
2| " x 24". Cap. 90 GPM. 15' head.
Motor is 3 HP, 1750 RPM.
1--1
oo
Scales
2*1-02*16 2*1-0187
Made by Toledo Scale Co. 800// capacity, dial type scale.
167 Plow Tank #1
21-0750
Tank made by Graver. Dwg. K-863. 7' dla. x 7' Btr. Bide, dished heads 4 shell 3/8", 5 turn coll of 2" xlly pi pe.
369 Surge Tank
22-0751
Cyclone collector made by Graver.
Dwg. B-695. **8" dla. x 27" on sir. Bide, 3' 6" long and tangential inlet near top of side. 3/l6" steel - throughout of welded construction.
170 City Water Pump //I
69-1083 69-3365
Taber lloriz. pump. Model CR6, 3" x 24" 9" impeller. Cap. 180 0PM, 50' head. Motor iB 74 IIP, 1800 RPM.
171 Cl ty Water Pump 7/2
37? Off-Gas MlBt Ell mlnator
69-2078 66-1796
21-5150
Same as Item No. lfO TRAN 007007
30"0D x 13'-3" straight Bide, steel construction, vertical for brink Filter Element 7/15-0630(7/2*196 carbo
173 Off-Gas Heat : 38-5588 8'long x 16" 0D, 2 pass on tube
Exchanger
.
side, 5 baffles, steel construction
WATER PCB-SD0000041963
DcpU 246 - Process Description
AROCLOR
APPEND]X A
EQUIPMENT LIST (Con t'd. )
] tem No.
Kquj pmcrit Name
Plquj pment Number
19. C'O.v.hV- . /
CONFIDENTIAL
Descript ion
380 Exhaust Blower
11-0265
Made by American Blower Co. lypc 450E. Capacity 1b 6408 SCKM at 3330 RPM. Dwg. E-10699* Motor Js 35 HP.
385 Coke Scrubber jj1 21-0756 Scrubber liquor tank made by Graver. Dwg. C-800. 4'6" Dia. x 5 '6" on Str. Side. Coi3 3 turns of li" x Hy pipe.
386
Coke Scrubber //2 21-1396.
Same as Item No. 185.
200 Cyclone Separator 21-1413 Separator made by Heintz Stec. 3' ID x o' high tangential separator with
integral vapor pipe complete.
20]
Air-cooled Heat
38-5328
Air cooled heat exchanger made by
Exchanger //5
Disler. Cooling capacity is 1,200,00
BTU/hr. Steel construction except fo
aluminum fins. Kan motor is 2 HP,
1150 RPM.
203 Steam Vacuum Jet #1 35-3523 #2 | Worthington 3-stage vacuum Jet.
204 Steam Kacuum Jet H2 35-1686 Same as Item No. 203.
205 Steam Vacuum Jet //3 35-3533 3-stage porcelain Kubati vacuum ejector with 10" 3D porcc]ain conden
ser. Jet has a capacity of 10///hr. air at standard conditions. Jet designed for 150// steam and 2 mm Hg absolute.
206 Off-gas Drowning Jet 35-4736 Made by Schutte-Koertig. 8" Havcg fume scrubber. Comp3ete with stand ard nozzle.
207 Drying Oven
14-0338
Grieve Hendry drying oven, 440 V.,
3 phase, 60 cycle, manual reset temp, controller range 0-400C.
230
Air-coo3ed Heat
38-5564
Same aB 3tern No, 203.
Exchanger //l
66-8113
23 3.
Air-cooled heat Exchanger //2
38-5565 66-8134
Same as item No. 201.
232
Air-cooled Heat
38-5566
Same aB 3tem No. 201.
Exchanger //3
66-8115
233 Air-cooled Heat . 38-5567 Same as 3 tem No. 203 .
Exchanger //4
66-8116
TRAN 007008
WATER PCB-SD0000041964
20.
Pcpi. 246 - Process Description AROCIOU
C(&P^Y
ConfideNtial
APPENDIX A
EQUIPMENT IJST (Coni'd.)
3 lem No._
Equipment Name
Equipment Number
Do script! on
23 4 Air Pryor
14-0138
215 City Water
69-4363
Worthington 3CNFK84 with 8" impel lei
Circulating Pump 66-8179
and Monsanto standard base.
236 Polish Filter //9 Storage
13-0633
AlBop filter model No. PAK 325-4,
316 b B,, 6,000 in.2 filtration area.
840 in.3 volume.
.
237 Polish Filter //3 0 Storage .
15-0634
Same as Item No. 236,
238 Polish Filter //3.3 Storage
15-0633
Same as Item No. 216.
None
Ch3orine Pressure 29-1547
Made by Taylor Instrument Co.
Recorder
l
Pressure Recorder with 2 pens. Range 0-100.
None
/5 Chlorinator Flow Recorder
29-2019
Made by Taylor Instrument Co. Flow Recorder - Controller Cat. No.
137RF135. 12" chart, 0-30 Sq. root chart.
None
Water Meter
29-2486
Made by Worthington Corporation. 3" model 1H turbine type water meter.
None
#3 Still Tempera 29-3885 ture Recorder
Made by IeedB & Northrup Co. Temperature Recorder. Range 0-400C
None
//I Still Absolute 29-1170 Pressure Controller
Made by Taylor Instrument Co. Absolute pressure Recorder - Controller.
None
200// Steam Flow Recorder
29-0835
Made by Bailey Meter Company Flow Recorder.
None
//2 Stl 3 3 Absolute 29-3353 PreBBurc Controller
Made by Taylor Instrument Company. Absolute PreBBurc Recorder Controller.
<
None
//2 Still Tempera 29-0244
Made by Leeds & Northrup Co.
ture Recorder
6 point Temperature Recorder.
None
//2 Still level Controller
29-1463
.Made by Taylor Instrument Co. Liquid level Recorder - Controller.
TRAN 007009
WATER PCB-SD0000041965
I
{
Dept. 2jl6 - Process Description
COMPANY
21
CONFIDENTIAL
AROCIOR
APP_KNDJ_X_A
EQUIPMENT LIST (Cont'd.)
]tem Equl pment No__Namo_____
EquJ pment Number
DcscrJ p ti on
None
Chlorlnator
29-0288
Temperature Recorder
Made by Ioeds & Northrup Co. 12 point Temperature Recorder,
None
//I Blow Tank
29-2916
Temperature Recorder
Made by Taylor Instrument Co. Temperature Recorder Controller,
Adjusts 200# steam to //] Blow Tank Cat. //86 RM*i3l83>-32.
None
80// Steam . Plow Recorder
29-5^52
Made by Foxboro Company. Type T37, recording flow meter with integrator and Indicator. Meter body 316 6.6. Integrator
for 80#, 400F. steam.
None
200# Steam
l Flow Recorder
29-5^53
Made by Foxboro Company. Type T37 Recording Flow meter with integrator and indicator. Meter body 316 s.s. Integrator for 200//, 510F. steam.
TRAN 007010
WATER PCB-SD0000041966
Dept. 246 - TVocess PcBcrlptlon
AR0C2OR APPEND]X b
SPEC] FI CATIONS
COMPANY CONFIDENTIAL
The following; is a li6t of the raw materials used for the manufacture of ArocDors. Specification 6hects are included where they exist.
Materia] Code
Raw Material
8?603
Hi phenyl
33500
Ferric Chloride
38800
lil me
.
19;I09
Attapulgus Earth
81039
Chlorine
43099
Nitrogen
64005
Xylene
The following is a list of the finished products manufactured in
department 2
Specification sheets are included where they exist.
Product Code 8117T2-------------
811.>5 8l30l(EIect & Non-Elect) 81102 (Elect & Non-Elect) 8ll03(E]tct & Non-Elect) 8lI05(E]ect & Non-Elect)
81107 81101-81102 (Mix)
82868
Product
^roclor Aroclor 12^2
XyJenc
Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 1242 - 1248 Mix Montar6 1, 2, 3 and 4
TRAN 007011
WATER PCB-SD0000041967
MONSANTO CHEMICAL COMPANY
OftOANfC CHEMlCALI diviuon
SPECIFICATION
. MATERIAL
DIPHENYL (BIPHENYL)
CHEMICAL FORMULA
MATERIAL COOC
82601
UtIMO DEPT*.
246
9UPPLIER
ANNISTON PLANT
MOL WT. 15^ *20 upcraedeiapbc* 6p
mu
OO
AMPLE pop analysis
2 x 16 oz. W.M.Bottles
UNRESTRICTED INFORMATION
Routine Tests
Appearance and Color
Crystallizing point GENERAL INFORMATION Distillation Range:
First Drop to ' Dry Point
Specification Light Yellow Cryst. Solid 687*C, min.
2.5C, max. Must inolude 255*C within Range
Issued nrp ft IQ
&
Method Number 10,252 10,298 10,299
This specification Is the property of Monsanto Chemical Company and Is for internal use only.
COMPANY CONFIDENTIAL
TRAN 007012
f
P*H IM IREV. ll/ltt
WATER PCB-SD0000041968
I
Monsanto
OROtNIC CH*m|CAL DIVItlON
W. G. KruniArrich Plant RAW MATERIAL
. SPECIFICATION
PRQOUC 1 ION
T. W. Dalton
PROCUREMENT
C. A. PralLe
KNERAL DESCRIPTION
MATERIAL CODE
33500
PLANT
WGK
OAJAirT1966
MATERIAL
Ferric Chloride Anhydride
UttNO OEPTS.
233
UPPLIER
McKesson t* Robbins
APPROVAL*
RESEARCH
M. A. TerpBtra
QUALITY CoNUIOL (Chit! Chtmlml)
W. J. Gresham
chemical formula
mol wl. 162,21
UPEA1COEA EPCCk OF
11/15/62
Fe Cl,
SAMPLE FDR ANALYSIS
1 x 8 oz. W.M. Bottle
C MAR AC T ERIE TIC
LIMIT S
UNRESTRICTED INFORMATION
Appearance
'
Assay
Sulfate 6
<
Ferrous SaH$
Solubility: ,
10:10 of Water
10:10 pf Formula 30 Alcohol
Black powder or Granules 97.0%, min. 0.05%, max. Trace, max.
Complete to slightly turbid, max. . Complete to slightly turbid, max.
ISSUED Y
J. P. Prader
ME T HOD
J. F.Q. 16 -A
22-570 120-570 S-570-1 112-B
COMPANY CONFIDENTIAL
(
(JO nputlrf Antfpsfs, All
kj r***// only.
TRAN 007013
j
WATER PCB-SD0000041969
Monsanto
OROANIC CHEMICAL, OlVltlON
RAW MATERIAL . SPECIFICATION ------------------------- 1.
PRODUCTION
P. E. HeisleT
PROCUREMENT
r. A Pratle
ENERAL DEACRIPTIDH
Ca (OH)2
UFlRlCDd 6/20/63
CHARACTERISTIC
OP
Appearance
Assay (Ca{OH)2) Carbonates a$ (CaCOj) Magnesium Sulfates (as $Oj)
material cod*
38800
MATERIAL
Lime, Hydrated
PLANT
WGK
u.,n. .spT..ZZZ'
246
OAT I IFFtCTIVI
7/21/66
Mississippi Lime
APPROVALS
RCtlARCH
M. E, Gibbs
QUALITY CONTROL (Chill ChwnIII)
W, J. Gresham
Go.
CHEMICAL FORMULA
AMPLE POR AN ALY!,
1 x 16 oz. W.M, Bottle
LIMIT*
| lltUEO Y
MCTHOO
Fine white or Blightly gray powder, free from lump6 or gritty material
92.00%, min. 3. 00%, max. 0.50%, max. 0. 30%, max.
10, 188
10,191 10, 193 10.192 10, 189
Supplier*6 certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto Co., Monsanto, III.
.. :
COMPANY CONFIDENTIAL
TRAN 007014 1
WATER PCB-SD0000041970
Monsanto
OMOANIC CHEMtClkLi DIVISION
W. G. Krummrich Plant RAW MATERIAL SPECIFICATION
PRODUCTION
P. E. Heisler
MOCUMMINI
C. A Pratte ;
amtmi. ^---------------------------------------------- ---
dcscwi tion
I
dFlUMMtDd Idccs _ 11/15/62
CNAAiCTCMliTIC
MAT cm AC CODE .19409
ft ANT WGK
DAT C IFftCTIVt 1-21-66
MATKftlAV . Attapulgus Earth 200/UP
UHNO 0*^T.
.. 24b
Mineral ic Chemical Phillips Corp,
RCICARCN
W. D. Robinson . OUAl.IT T CONTROL fCM#f Choinlll)
_ W. J. Gresham CHEMICAL rOAMUll
Clay
UMPII FO ANALYIII
2 x 16 oz. W.M. Bottles
LIMIT#
1 IIIUtD B>
J, P. Prader
UNRESTRICTED INFORMATION (R) Volatile Matter (at 950*C.) (R) Mesh Test:
Through USS 325
6 - 8% 90%, min.
This material is not accepted without the supplier's analysis of the above properties.
Anmlyl*. All IAr Anlr* *> I******
COMPANY CONFIDENTIAL
TRAN 007015
WATER PCB-SD0000041971
Monsanto
ORGANIC CHEMICAL* DIVI*ION
RAW MATERIALSPECIFICATION
PRODUCTION
J.M.C.,
PROCURKMKNT
C.H.C.
P.E.H..
W.B.P..
CNtAAL OKRCAIPTIOM
uatcrial cod*
MATERIAL
PL A4M3T099
Nitroeen Gas UtlNO DIPT!.
---
WGK OAT CfPtCTIVC
See Below UPPLICA
--
FEB 1 8 1965
Air Reduction Snips On
APPROVAL* AIIIARCH
C.H.S.
R.W.B.. H.W.K.. M.A. T. . OUALIT V CONTROL (Chi,/ CRwItO
W.F.S. W.D.R. r --J. A - S.
W.J.G.
C.H.R. J.S.M,
CHlMIC At r ORMULA
Grade - 0. P. Special Nitrogen
New
CHAftACTCftllTIC
IAMPLC rOR ANALVIll LIMITS
IMJKO V
Assay (l)
Oxygen
Hydrogen
DewPoint
Nitrogen Argon Oxygen Carbon Dioxide Acetylene
99.9%, min.
(2)
0.1#, max.
0#
-76F
Typical Analysis
99.78#
00..11#2#
<.00005#
<.00005#
<--
Nitrogefr plus inert rare gases Any analyses to be obtained from supplier on request.
B-215, C-216, 244, 246, 247, E-254, A-255, 256, 267, 270.
i'
COMPANY CONFIDENTIAL
, I I
(fO Aoufln* Anmlfl*, AM 9thf9
TRAN 007016 ~
WATER PCB-SD0000041972
I
Monsanto
ORGANIC CHCMICALf DIVItlON
c RAW MATERIAL SPECIFICATION
PRODUCTION
J. E. Smith
PROC UKtMtNT
A. H. Smith
'
MATERIAL COOC
64005
plant
WGK
OATS EFFECTIVE
6/21/66
material
5* Xylene
CHINO DEPT*.
A-255
SUPPLIER
Chem Tech
APPROVAL!
RESEARCH
C. Eaker (Nitro)
quality control fCMW Chtmltl)
W. J. Gresham
cncral OOCRIPTlON
C6H4(CH,)l
chemical formula
'
mol. wl. 106. 1(>
7/12/63
1 x 16 oz,
CHARACTERISTIC
UNRESTRICTED INFORMATION
ISSUED V
J. P. Prad er
(H) Appearance
Clear Colorless liquid
(H) Sp. Gr. @15.5/15.5*C.
0. 860 - 0. 870
T-2516
(R) Distillation Range 1 st Drop
1 37 *C. , min.
T-2518
Dry Point
143*C,, max.
100% over in
.
5*C. , max.
.
Acidity Sulfur compounds
No free acid
.
Free of H*S and SQ*
Supplier's certificate of analysis to be. sent on day of shipment to: Chief Chemist, Monsanto, Company, Monsanto, 111.
COMPANY CONFIDENTIAL
(/
TRAN 007017
fit) Rsoffn#
All olhsfs Analya4 by requsil inly.
WATER PCB-SD0000041973
I
Monsanto
O ft 4 A N tC CHCUIC AU4 OIV1SION
FINISHED PRODUCT
specification
PRODUC T ION
T. W. Dalton W. E. Aull
CNCftAL OCtCftIPTlON
PROOUCY
CHLORINE, Liquid
Jeter. | 232
PLANT
WGK <oat irriciivc
j JUN 2 9 1966
PRODUCT CODE
81059
TTnTTo5T~
USt
Sales and Internal
3060-000-06-03
APPROVALS RC.tARCH
N. F. Mueller
DUALITY CONTROL (CM.f CffmltO
W. J. Gresham
chCmic al formula
Hot in. 7I 0v, 97 1* 41
UFtftBKOO IPICI. OF
6/24/63
AMPLC F Oft AnALYIH
1 x 40 ml. Beaker 3/4 full
C MAR Ac T CRI.TIC
LIMITS
UNRESTRICTED INFORMATION
lilVIO T
(R) Appearance
Clear heavy liquid
(R) Color
Amber to greenish yellow
(R) Moisture
. 015%, max.
(R) NVM
.01%, max.
J. P. Prader
MK T MOO
10, 748 10, 748 12,793 12,793
Jron 8: Fe. FCl|.6HiO
+Report % Report %
10,688
When used in manufacture of AC1 products, the specification on Iron as Fe is 20 ppm max. (H.V.Moss)
For use in Depts. 264, 258, 238, 243, 244 and 251.
COMPANY CONFIDENTIAL
('
TRAN 007018
i kaIv t ri by tt out st Only
WATER PCB-SD0000041974
Routine Te$ts
Appearance
.
Sp. Or. @25/15.5C
Acid Number
Color, APHA
H20
General Tests 1 ..... -- ' i
Chlorine
.
Specification Clear Liquid 1.266 - 1.276 0.014 mg. KOH/grm. max. 100, max. 35 PPm., max.
31.5 - 32*5^
Method No
10,114 10,087 10,084 10,620
This specification Is for Internal use only.
COMPANY CONFIDENTIAL
* <\
TRAN 007019
WATER PCB-SD0000041975
MONSANTO CHEMICAL COMPANY
OBOANIC CHEMICAL* DIVISION
Krummrjch and Anniston
FINISHED PRODUCT ' . SPECIFICATION
400 UC T
Mavtj " "
Aroclor 1242
PRODUCT (OimiImI Hmk)
PBOOUCT CODE
DEPT. OR JOB
81101-82612
use
Sales
SALES CODE
W0K-246-Ann.27
1040-240-04/ll/l6-03/09
. TYPB
NoDrElectrlcal_Orflde
tvpb
Issued
VI
By
rianr-
CHEMICAL fORMULA
Mixture
MOk VT. uriMcoKi ircci or
5-11-61
. '
f
AMPLB POP ANALYSIS
^___ 3 x 16 02. v. m. nottiftH
m
UNRESTRICTED INFORMATION
Routine Tests
Condition
.
Color, APHA
Sp. Gr. (25/15.5#C)
Acidity (mg. KOH/g.)
Moisture (H2O) (ppm.)
General Tests
Distillation Range
(ASTM D-20 Corrected) 10# Distilled by wt. 90# " n "
ViBCOBity 100*K (SUS)
Flash Point (*f)
Fire Point
Specification Clear 100 max. 1.381 - 1.392 0.010, max. 50, max*
325*C, min. 360*C, max. 82-92 338 - 392 None
WOK
Anniaton Method no.
10084
0-1
10084
046
10114
052
IOO87
050
10620
047
10117
14-31-54
10086 10123 10123
049 14-28-54 14-28-54
COMPANY CONFIDENT/AL
m IN M (PBV. tl/SSI
TRAN 007020
WATER PCB-SD0000041976
MONSANTO CHEMICAL COMPANY
MVAHIC CHEMCALt DIVIIION
W.G.K. and Anhlston FINISHED PRODUCT SPECIFICATION
PRODUCT CODE
81102
1 27 Ann.
IMI
Sales
ALU COOE
1040-260-04/11/16-05/09
PROO UCT (Trad* Mmr)
'
TYPE
Aroclor 1248 Electrical Grade (Pyranol 1498)
PRODUCT (Ohtmltmt Htmt) ~
TYPE
CMftMICAL FORMULA
Issued 1/10/64
.w.0^^
Corrected 2-16-64
Mixture
r
MOl WT,
2-12-60
IAMPLC FOR ANALYSIS
5 x 5 Pt. Amber Bottles
UNRESTRICTED INFORMATION
Routine Teeta
Color, APHA
Condition
Sp. Or. @65/15.5C
.
Acidity (mg. KOH/gm.)
Moisture
Refractive Index @25#C
Inorganics (Free) Chlorides
Pour Point
Dielectric Constant
(1000 cycles @100c)
Resistivity
(500 VDC @100*0 0.1" GAP)
as OHM-CM x 10?
Hydrolysis Stability Teat
(aa Chloride#)
Monsanto Stability Test
(aa Chlorides)
Distillation Range '
(ASTM D-20, Corrected)
10g Distilled by Wt.
90g Distilled by Wt,
Specification
50, max. Clear 1.405 - 1.415 0.010, max. 55 ppm., max. 1.6285 - 1.6505 0.05 ppm,, max. 0C, max. 4.5 - 4.7
500, min.
1.0 ppm., max.
0,5 ppm., max.
545*0, min. 585#C, max,
Method No's WOK . Annletor
10,084 14-44-5* ` 10,084 Q-l
10.114 14-49-51 10,087 14-42-5* 10,620 14-55-51 10,125 14-54-51 T-2092 014 10.115 14-27-54 11,608 14-56-54
11,607 14-55-57
T*-2087 010
11,505 14-61-57
.. 10,117 14-51-54
General Tests (made only on request)
Sulfates
Dielectric Strength @25*0 Fire Point Viscosity @54.4*0 (SUS) Corrosion Test
(6 hrs. @210*0 with bright aluminum foil) Change In wt. of A1 (g)
None
55 KV, min. None to boiling point
75 - 80
12,169 - - 11,605 045 10.125 14-28-54
10,086 14-4-52 10.126 ]4-55-57
COMPANY CONFIDENTIAL
(over)
TRAN 007021
V CD IN M IftCV. 11/OI
WATER PCB-SD0000041977
TI
A. C. Color, APHA
60, max.
A. C. Condition
Clear
A. C. Acidity (mg.KOH/g.)
0.010, max.
A. C. Inorganic (Free) Chlorides 0.05 ppm., max,
GENERAL INFORMATION
i i --i
P
Specific Heat P^'C Fixed Chlorine
0.27 47.5 - 48.5
10,08*
-54
10,084 0-1
10,087 14-42-54
10,118 010
COMPANY CONFIDENTIAL
TRAN 007022
WATER PCB-SD0000041978
MONSANTO CHEMICAL CfcUPANY OAOAMIC CHEMCAL1 DIVISION
Xrummrlch and Anniston
FINISHED PRODUCT
SPECIFICATION
"mOOUCT
'
Aroclor 1254 product (c*(/ /--*>
PRODUCT CODS
DSPT. OR JO*
81103 - 82613 WGK-246-Ann.27 Issued 7/15/64 use W. 0. Krummrich Piarit,"
Sales
By. . Yu 7Y>
SALS* CODS 1040-280-04/11/16-03/09'
.'
; TTr Non-Electrioal Grade TV**
' *
.
CHEMICAL FORMULA Mixture
* .i
*
MOL rf.
(. AMPLK FOR ANALYMt
5-4-61
3 X 16 02, W M. Bottles
- UNRESTRICTED INFORMATION
Routine Testa
. Specification
.
WOK
Annistor
Method No.
Color, APHA
Sp. Or. 65/15.5*0 "\ '
' Acidity (mg. KOfl/g.)
Moisture (H20) (ppm.) :
Oeneral Tests
Flash Point
. '
Visoosity 210V (SUS) '
100 t max
. 1.495 " 1.505
0,010, max.
. 50, max.
;
. . '.
.
None 44-48
' ''
.
10084
' ion 4
. 10087 10620
. 10123 10086
046 052 050 . 047
14-28-5' 049 '
(
-
.
.. ' .
.
.
COMPANY CONFIDENTIAL
TRAN 007023
WATER PCB-SD0000041979
Monsanto
OllANIC (MIMIC ALl OlVlilON
ANNISTON AND KRUMMRICH I^INIIHBO PRODUCT f PICIPICATION
MAaIuCTIOM P. E. Hel*lor illII ' ' W, E. Aplt
Ar oc Ior 1260 mwamY Anniston
Krummrich rxrr wnttm--------
5/25/66
#,,T Ann
sir WGK -
Ale a.
1040-290-04/11/16-03-09
MIIARCM
----
W. D. Roblnion OUAbITV COHTAOL (Chll Ch**tl*0 (J, , Dolin
W. J, Greiham CMlMCU P*MUbA
_
Met WT
2/7/62
rrr
UNRESTRICTED
AM ANAb 3x5 pt. Amber Bottle
INFORMATION
(R) Colpr (APHA) (R) Condition
150, max. Clear
(R) Specific Gravity @ 90. 15.5*C. 1.555 - 1.566
(R) Acipity (mg K.OH/g,)
0. 014, max.
(R) Moliture (HjO) (ppm) (R) Vii^oiity @ 210*F. (SUS) (R) Refractive Index Q 25*C. (R) Inorganic (Free) Chloridea (R) Pou!r Point (*C)
35, max. 72 - 78 1.6455 - 1.6470 0. 05 ppm, max. 25 - 34
(R) Dletillation Range
(ASfM D-20, Corrected)
10% Diitilled by wt,
385 - 398*C.
50% Diitilled by wt,
390 - 404*C.
90% Diitilled by wt.
400 - 420*C.
(R) Corfoiion Teit
(6 hr. @ 210*C. with
bright aluminum foil)
(R) Change in weight of A1 (Q)
0.0
(R) A . C . Color (APHA) (R) A.C. Condition
(R) A . C,. Acidity (mg, KOH/g.) (R) A.C,. Inorganic (Free)
150, max. Clear
0.014, max.
Chlo.ridea
'
0.05 ppm, max.
vnuttTT
J. P. Prader
WGK.
10084 10084 10114 10087 10620 10086 10125 10118 10115 10117
10126
Anniitor
14-44-5
14-49-5 14-42-5 14-53-5 14- 4-51 14-34-5 14-48-5' 14-47-514-31-5*
1
14-55-5:
10084 10084 10087
10118
1 4- 44-54 14-42-54 14-48-57
COMPANY CONFIDENTIAL
TRAN 007024
(KJ Routint Antlytti, Att clktrt AnatyuA kr rtwmtii 0*1*
WATER PCB-SD0000041980
I
i/NRESTRJCTED INFORMATION (Corn'd.)
Charact eristic
Limit*________________________ Method
WGK _
Anniston
k * II 4 villi
Fire Point
None None
Fixed Chlorine (%)
59.5 - 60.5
(R) Die ectric Strength
@ 5Q*C.
30 K.V., min.
(R) Relativity
500, min.
(500 VDC @ 100*C.
0. 1" gap ai ohm * cm x 109)
(R) Dielectric Conetant iOOO cycle*, 100'C.
3.6 - 3.8
10123 10123 10088
11605 11607
11607
14-28-54 14-28-54 14-13-54
14-35-57
14-36-45
RESTRICTED INFORMATION
(R) Monsanto Stability Teat (Aa Chloride* in ppm. )
GENERAL INFORMATION
(R) (2, (R)
Evaporation Loa* after 6 hra. @ 100*C, (%)
Stability teat - after 30 daya at 100'C. in glaaa aealed in air.
0.7, max.
11503
0.2, max.
10116
No liberation of chlorine or chloride*
14-61-57 12-32-54
s
COMPANY CONFIDENTIAL
TRAN 007025
WATER PCB-SD0000041981
Monsanto
OR O A NIC CHtMIC ill OIVIIIOM
ANNISTON ^ND KRUMMRICH FINISHER PRODUCT
product
AROCLOR DISTILLED 1262
PLANT
ANN. k WGK DAT! if >ie VivI
8^TST-.
uft
81107 -WGK_____
Al c* tobi.
l*PT'Ann 2 | woK-VaI
------- *
Sa le s
1"
<
SPECIFICATION
MAR 02 196G
1040-300-04/11/16-03-09
APPROV AH
PRODUCTION
RillARCH
P. E. Heisler
W. D, Robinson
ALR*
W. E. Ault
i
IINCKIL OCiCRIPTIOM
--' -- -
OUALITv CONTROL (Chltl C/iMlUU
W. J . Gresham
O. E. Dolin
C MIMIC At FORMULA
MOL WT. lUPtniiDci (Fact, op
1/24/62
CHAR ACTf^llTIC
2 x 16 oz. W.M. Bottles
LIMITS
(USD V
J, P. Prad er
MKT MOD
UNRESTRICTED INFORMATION
(R) Appearance
Viscous liquid
10084
(R) Color
APHA 150, max.
10084
(R) Specific Gravity @ 90/15.5*C.
1.572 - 1. 583
10114
(R) Acid No. (mg. KOH/g. )
0. 014, max.
10087
(R) Viscosity @ 210*F.
86 - 100 SUS
10086
GENERAL INFORMATION
Pour Point (ASTM)
35 - 38*C.
Distilling Range
390 - 425 *C.
Total Chlorine
61.5 - 62.5%
Specific Gravity Temperature Coefficient (85 - 130'C.)
0. 001/C.
COMPANY CONFIDENTIAL
(
(R) Routin' Anolyiii, All ethtn Anotyi'd by itquttl Only
TRAN 007026
WATER PCB-SD0000041982
MONSANTO CHEMICAL COMPANY
DROAM1C CHEMICAL* DIVISION
Krummrich and Anniaton FINISHED PRODUCT SPECIFICATION
PRODUCT CODE
82868
\nm
ALES COOE
#See
PROOWCT CTiiS Man*/ -----
__ Montar8_l..and 2 ^______________
PRODUCT {C*Mloa/>ram;
_ Polych1or1nated polyphenyla
CHEMICAL FORMULA
DEPT. OR JOR
WOK 246 Ann.
Sales
Below
TYPE
Issued
.Ml 1 51954
W. 0u. Krummrich J>1 ant
BY
Mixture
MOL WT. _____________ SUPERSEDES SPECS OF
6-15-61
SAMPLE FOR ANALYSIS
2 x 16 oz. W. M. Bottles
UNRESTRICTED INFORMATION Routine Teats Appearance Oeneral Information
Specification Black Solid
Anniston WOK ~ Method No.
14-17-52 11521
Physical Properties (Typical Values)
Montar 1
Montar 2
i Softening Point (ASTM E-28-51T) Acidity Chlorine Content
54-l6o*C Slightly BaBic
56-42%
70-170*0 Slightly Bael 44-48%
CaO Fe Benzene Insoluble Flash Point
5-15JC 0.5-1.0J6
500-620*F
5-1556
0.5-1.0%
12.556
RESTRICTED INFORMATION
Montars 1 and 2 re the atlll residues from distillation of Aroclors 1242
and 1248 respeottvely. Composition of these Montars Is not controlled, being entirely dependent on conditions required to make acceptable distilled product.
Sales Code Nos.
COMPANY
CONFIDENT/* i
Montar l 6405 - 001 - 04 - 03/09
Montar 2 6405 - 002 - 04 -
TRAN 007027
WATER PCB-SD0000041983
MONSANTO CHEMICAL COMPANY ORGANIC CHEMICAL* DIVISION
Krummrlch and Anniston
^ FINISHED PRODUCT SPECIFICATION
r0DUCT COOK
OEFT. ON JOB
Issued
^ 5 1964
82868
use
SALES CODE
WGK 246 Ann.27 W 0. Krummrlch Plant
Sales
fiy___ y* T>T>3 &
)
' *See Below
Montars 3 and 4
rsoovcr
m*.;
Polychlorinated
CHEMICAL FORMULA
Rolyphenyls .
..
TVF*
Typi
.
.
*
.
woi rr. 6-15-61
Mixture
t
SAMPLE FOR ANALYSIS 2 x 16 oz. W. M. Bottles
UNRESTRICTED INFORMATION Routine Tests
'; Specification
Anniston
WG1
Method No.
Appearance
Black solid
14-17-52 113:
General Information
Physical Properties (Typical Values) N --------------
loftenlng Point (Method ASTM E28-51T)
Montar 3 86-l68*C
Montar 4 92-206*C
Acidity
Slightly Basic
Slightly Bas;
Chlorine Content CaO
50-52*. 5-1056
54-56* 5-10# '
Fe
'
0.3-0.656
0.5-1.056
RESTRICTED INFORMATION
Montars 3 and 4 are the still residues from distillation of Aroclors 1254 and 1260 respectively. Compoaition of these Montars is not controlled, being entirely dependent on conditions required to make acceptable dis tilled product.
Sales Code Nob.
Montar 3 Montar 4
6405 - 005 - 04 - P5/09 6405 - 004 - 04 - 0>/09
" COMPANY CONFIDENTIAL
TRAN 007028
WATER PCB-SD0000041984
23. Dept. 2H6 - Process Description AROCLOR APPENDIX C
PHYSICAL AND CHEMICAL DATA Physical Constant Data sheets which are available are listed following this page.
COMPANY CONFIDENTIAL
( TRAN 007029
WATER PCB-SD0000041985
T
C3im
PHYSICAL CONSTANTS DATA
tDhlTAHtl
1I '
1
~ -
ITRUCtUMAL PO___R__W--Uk A
--- ==^=
R2601 DIPHpNYL
\ 7--\ )
twpilio ' VV, F. jwelzner Z/1Z/43 Kev. 0AT
6/22/43. l/11/^4. Rev. A. M.EllePbmg___ 6/26/67
Bellsteln V - 576
NAME
formula
Molecular VeliM
.
Appearance________ ________ _______________
C6Hr CgHr
.154.20 MonocllnLc
______ tournee * pate____________
chem. Rubber tiandb&dlc-- >l ll 1841'-42-----
Boll ins Polrt 4 760 urn 1_____________________ asRwr
Int. Cr it TAbles Ifl9.ft
60 Uni Paid 4tn jfim .
11a
Swann file 4 137 1 D3R
line Point 4 ma
poll Ins Point 4 m .
CrvsUlllzIne Point
66. Q^C____________________ _ Swann Curves 1034
Ifcl line Paint
.
fifluC
Tnt, fir It Tables 1 Q9R
Sol utlon Point Soeclflc GrivltY *
Specific Grevfty #
______ 17 / 4"C
,20/ 4UC
0.9896 1 041
Int. Crlt. Tables 1028 II II tl ||
Pound* per Gel. # 77' C'
ft 23 lbs, per a1.
Swnnn File #1.37 A 1Q3D
Coefficient of Ewettion
Reflective Index 17.1 WC i
D = 1.58822
Int. Crlt. Tables 1B2R
Infra Rad Spectrum fReftnnet)
Ultra Violet Spectrum (Kt'rmet)
VlacosItY Vlacosltv t
: 100UC , 70C
28. 8 Ray. Sat.
31.2 "
"
Swann Ftle 137A 1030
11 it
11 11
Surface Tanilon
, 129, 2C
29. 5 dyne/cm_____________ Int. Crlt. Tables 1928____
Solubility In W4er & j BDC
Insoluble _________________ _ Dow
1943
SoliCillltv InBbs./fl'cJ. 19. 5WC
9.98 g./lOO g. solvent .. Seidell
1A41
Solubility In 100% JVLeihanol 19_5C___ 6. 57 g./lOOg. solvent
"____________ LL4J__________
Bl?nzene @ 27.9C.
137 g. /lOO g. solvent
HrfDtane @ 26. 6C._______________ 25.1 g. /100 g. solvent
" "
1941 1641
Flash Point F fU*W>
Fife Point
. fnnpn mini_
tillit of Corn tuition Hoit of Formation
, kg-rel (16)
r ''
Thermal Stability (calTki/rntn.)
(.Merit Heat el Fusion !
LMent Ht4 of Vap. , & 255C
Soeclflc Heat
Critical Temper***
Critical Piaitife
,
Dlisoclatlon Cons!el . Intent Heat of.Fusion
235F - closed cup gif Jo*, " open cup
per gm mn] - 1604 4
Ind, & Eng. Chem. 1940
32 882
Ru/pnn Ft'** fin a
Int Crlt Tpbi^c j'pyg '
136. 6 RTU/lh
0 43 pTIt/lK F
R28r ' 41,4 Atm, ehanliitp
Swann Ftle #137 A (1928)
_ R&E CR 964 (1956)'
'
Few, Rot Incf rnment 1 583
' "
" "(1930
2A.8 gm-OAl per gm
Lange Handbook__ 1637
' ( 53*. 1 BTU/lb )
"_______________________
s*Vm*
0
(1 0
nnMPANY
CONHutf\i rlA(
TRAN 007030
NOTE: -Eliaa of W.P.Metzn :r. St. Louis
Toxicity f&vt kkn*c+)
MS Dr Mr.T.eRtrr, Anniston >lant. Report copv In
/7\
__St__ I .on tc f\kelr Ionic fit *
'
Pprrv MA4-"Chemlstrv of SVntheltc
D_r_u_g's '__3_e_d.1p61. 711
WATER PCB-SD0000041986
T
.* .
f
J
"0. PHYSICAL COM:
.
*Tuu"VTXnC^
11
1
" ( "T FSRRIC CHLOMtDi, ANHYDROUS
1 -w*'
1*
P( i^-Salt Chen.' Co.
; * PTimrcray Penn-^kit'Chemr Co.
j
'AM S DATA
. - ITAUCTU- ftAl FORMUL. A ---Ur
J6-57---------
u.* , v
------------------ .u--1--1
NAMjE
Formula
j
*
ttolcculer Wei ".hi
,
L searance
.
. . fis iline Point at 7fO mm . eo ilinj Point at mm
Bq i|ln Point M Bo iline Point at
mm ' mm .
Crvslalliain* Point
Htliin* .Point
! So ution Point
'
Si icifie Gravity *
!
:
Specific Gravity *
'
1
Pounds per Gal.*
!C
Coefficient of Expansion '
j
Refractive Index*
, nf
1 Inlra Red Spectrum(Reftn'^tt)
I ' Ull ia Violet Spectrum (Rtfvtnet)
ViiCOSltV *
'
t Viscosity*
i
Siu fete Tension
,
utility in Water
.
..
4 Sfc] utility in
.
. " Sol ubilitv in
.
FeC!, 166.22 ' .
Sublimes
'
V. Sol. fheact rise)
source & DATE
Ref-1 Ref. 1. -D _ / 1
.
*
'' Ref. I.
i I
1 ' * *
- Flash Point F (Utihoi) J
i
Fire Point C
.
; j
; '
1< 1 ;- .
.
.
Heat of Combustion
Heat of Formation
.
Thermal Stability fcal.At/min.1 Latent Heal of Fusion '
Latent Heat of Vao.
f
Specific Heat Critical Temperature Critical Pressure
, |
Disfoclitipn Constant .: riernnf>n.ren on ievnnenre tn_______
-stmt tr,
,
* 1V
V`
"
-------------------COIUPAMY--
CONFIDENTlAi
*
*ev OVbT'
Afrfer<:.7c4 i. Penn-out c. hen. Co. Tech. Data Shoe . 1* Specs,
O
>
<^ 5
^OxiciJy (Glut Rrftrtnetj
*
VC'T'G: *Tkr.1t '4rilh*xhott!4lntrt
tWriutaf VMiUt
TRAN 007031
1
WoMfinM CAtm/tfJ C*p`*y.' Uif
~
ihtett'If.mt ei9 tary, * .
WATER PCB-SD0000041987
PHYSICAL CONSTANTS DATA
lUnTXHCE
' 'I - - '
' r------- ----------- - - _. IT.N..U..C..T..U..I.U..L...F.O..M..M..U. LA
HYDRATED f-.IME (Calcium Hydroxide)
-----------------
A 'TMSIssITssIhnDSljLmime'lC.ocmoanv
"* 1-25-S7
A. M. Ellenburt Revised
7-12-57
nAmc Fotmuli Molecular WellM
AooeatMict_________,______________________
Ca/OHL 74..IQ 1 WhltA pnu/rior______________
aoumce a date Ref. 1
Ref. 1 Ref 2 __________________
Bolllnt Point M 760 mm______________________ Bo Hitt PoliO Mm
Bfl lllnj Point M aa Be lllni Polnljt____W______________________
CfYStilllilnj Point ( .
Meltlnt Point
.
npr-ompnnna_______________
Ref. 1
Solution Point
.
.
joecHic Gravity t 2QC____________________ 2.2___________________________ ___ Bell_______________________
Specific Gravity .
founds pot Gil. 0 20 C
4
Ref. 2
Coefficient of Exparsloi}
Retractive Index o (
*2
wD 1.574. Ed 1.545
Ref. 1
Infi Red Spectrum
Ultra Violet Spectrum fR*f***c*)
YISCOSltY o
.
Ylscoslty o Surfttt Tension
Solubility In WMer
( Solibllltv In
l85%aobr. .077%
06C Ref." 1
Soluble lx> acids and NH4 :i Ref. 1
-
Solibllltv In
Flash Point F ftotM)
Fire Point C
itHi)H of Combustion ,
.
He of Formation____ ,_______________________
Thermal Stdrllltyfcel^'iiiln.)
LMent Heat of Futon
'
LMent HM of Vao.
Specific HeM
Critical Tamo*Mure n
Critical PreiMie .
Dissociation Constant
References:
ft
m
1 Ijingon Hnnrfknnk. Erf. . J , 1 BRfi 2. JnfoFrpation by Vendor
0mft
1w
o
Toxicity /Civ* R*f*n*+*)
~
iV)MPAMY --CONFIDFN HAL
TQ AM 007032
WATER PCB-SD0000041988
PHYSICAL CONSTANTS DATA
MUIIUHW '
(UUI.A
CHLORINB
touFrcio >1
T5TTT
HAVE
Formula
Molecular laliM
'
Arwuranei
EBo&IIIUImw PPAoliltlf* 4aTloCOLa*a |i
. ..
Anlllftt PaM 4 lu^O
Bollinf Point M 1 am
Crvrliltlilni Point
UaIIim Paint
i
Solution Point
.
Soedfle Gravity O'C (*aa)
.
Specific Gravity a 20*0
Pound! per Gal. a
; C
Coefficient of Expmslon
Refractive Index t 0*d
n&
Infn Red Spectrum r*rvWv/
Ultra Violet k*dnm/X*(*rmci)
VIcoltyp .1
'.
yiicejlty*_________
Siufeet Tentlon
,
Sol Uilllty.ln *<___
SodMJtvln____ :____;____________ __ __ ____
Specific tfraYicV 0 30*C
_
70T? -34.OS -71.32 -100.06 -120.44 -166.94 : 2.49 1.408
1.47
.
1.377
aouwee a PATE___________ '
API Ref. 1______________ l .. Ref. 1 Ref. 1
Ref. 2
_Ref., 2_________________ .
. Lance
.
Ref. 2
_'
I.in me '
" " `""'
V
&
?
3 1
Flnh Point 6F rtirfw/
Fire Point 5C
:
Heel of Ccntuitlon j
Hoit of Formdlon .
Theimel Stability feal./lfi/itiO
patent Heat of FibIoo '
Latent H^at of Va. [
Specific Heat . ,
Critical Timttatari j Critical Pmun j
Dtisoclitlon Canatmi J
,
'
144*C 76.1 atmoa.
Ref. 2 . . . Aef. 2
..
1
Kef, 1 - Cajc. from del. data
* Ref, 2 - Monsanto Chlorine fmlt vt Uo
JoS
vvmrhAimMVi /
Oui\lF|OENT/Af
---_
TeReArNy 0AUrt/U33
"l *#4 :tily fCr'tr RtftrtAti) [
** ^
"! Ar rml* #,/
n/
*
C.hemtfiJ
,
?'*#
..
WATER PCB-SD0000041989
> PHYSICAL CONSTANTS DATA
Tcifrlvrr^-"'
ITHUCVuMAL fOAMut*
AROCLOR .242
tcwftctd TiT
<L:fcK_.}
Fotiwli______ _ _ . _,_______ Maleculai Weigh! __ '________
Appearance___________ ________
Boiling Point < 760 mm jH.ar.Re_ Bojling Enui 3
Boiling foinl a__ m_ _____
Boiling PoinJ g..... jnm ._s_______
CiyR*IJi*jn Point.. . ____
MeHug Point-
So!iHon.P.ciol_____ _________
Specific Gravity 25/25 C. Specific Gravityj 25/11 5,5 C. Pounds per Gal, *__ 2S~^C~
Coefficient ol Expansion 25-65 C. Retractive Inden #25 C t n & Inlra Red Spectium (Rtf<r<nt*)
Ultia Violet Spectrum (Rtjvtnct)_____
Ylkosiiyj
________
yiscosiJy.j_1 00 F
Surfaceliosion Pyr*T7cm @ 20rC,
Solrtllltv In Wger
Solubility Jn. 3A. Aicc/j.ol__@.23."C^
Solubility in Pyr: dir.r___ @ 30CC.
Ci;HiC!a ___ 25 7 ;ayg.,i _
Colpjless-Mnhle Qi------- J M. ^a- ii_ Bul.L,_Qp.:i ..`AAj6 j 125 - 560 C.
No-- c ryeialliti r eJ
1. 380 t. 58J - 1, 192 11,50
1 .6 245 - 1.6265
Specific a'; r_2^J.ArS5 M. B. OP 115
Sprc.if.ca L XL-.
U55_
34-15 SUS
82-92 5US JLi.J_______ lrt,r? .bie
2 3.3 g./100 cc 1.32 5
M.Jtt.-.flPjJ.iS____
If
. 1, _Cr.iL. ..Scu ^ lfl*, a 9L52
JvL-&..-QP-ix3
Flash Point
|c , o. c .
File PoinPc
P. o. c .
Heat ol Combustion_____________
Heat of Formation [henna! Sti>illly fcat./kg/in)n.)
Lgenl M al_fjBiojL__ _
LMent Heat ot Vao. cat/pm,
Specific ideal. H. 25 C.
Critical Temperature Critical Prassnt_______ _________________
Oimtciition Constrt_^_.______ Sprc:f:c Heat ^ ItOO'C^
JPOC.__________ Ncnc
61 _
0.29?
-Q. 3*0
Pn,r P~; r. T.* e row Co/idticMvi*y. cal/
I cm/ 'C/eec, D e ft'r;c Ccrsar *. 100 `C.
oO 6Q <~y.
-14 C. c.r lover 24.0 g 2* C
4. 7 4.9
_ Ca. cula t r ri_____ M. -B.jQP -J.L5l
^COMPANY CONFIDLirTTA
To br P--_b _JLl -d- _
m~i=r oprr/s
Toxicity (On* Rtfetence)
Con^c* Medea Dec.* .I
--
TRAN 007034
____
WATER PCB-SD0000041990
IT
j
13IK III
PHYSICAL
TuHtahci ' " --' 1
.____ABQCLQR JL248
CONSTANTS DATA
| If KUWCTi/NAL POPMULA
COMPILED "V"
A. M. Ellenburg
hXE
Formu|
Molecular Weight
Aocemncg.
Polling Point it 760 ib Boiling Poif< g 3 am
Range
Boilinf Point M am
Boiling Point M mm
Crystallizing Point
Melting Polnl
Solution Point Soecltic Gravity e_e_cnll:i-c Gravity a-
ounds pofUiT
25/25 C. r6e&M/1e5^c5^-Cl 26 ^
Coefficient of Expanslo<r55-650r
RelfKtlve Index a
?5urfl &
Infre Red Spectrum (Refertnet)
Ultra Violet Spectrum (Refrtnct) Viscosity_________ TfWr
Viscosity
Surface Tension
Dynes/cm 20C.
SoltftllltY In W4et
Soltllihr In 3A Alcohol 25C.
Solubility In ^yr lri(ne
SXTu.---------4-2f 57
Cl2 H6 Cla 292 fAvy.) Yellow Tinted Moh.Qll 345-385C 165-21
Non-crystalllz tng
JL415. 1.405-1.415 -12.04. 0-00070 cc/cc/ C1. 6285-1. 6305
73-80 SUS
44.2 .Inspluble. 15 g. /lQO cc 111.4g. /100 cc
SOURCE PATE
Monsanto Bull. OP-1 15m'o[
Specifications 9/9/54 Spectftcatlon 9/9/54 M.B. OP-115 J- Coll. Scl. 7 . 166. fl9521 M.fi. OP-115
Flash PolriT^k/tteW; p.o.c.
Fire Point C________ p_ o, e.
Meet of Corrfeustlon
Meet of Formation
Thermal Stability (eal.Afr'min.)
Kent Heat ol Fusion "
Kent Heat of Van.
^>l/gm.
Critical Temperature
Ctlllctl.Eimift
DUsoclation Constant
_
Specific Heata tQO^C.
Pour Point Thermal Conductivity, cal/"
..... .. " F cm/6/sec
Dielectric Constant. 100UC 1,9-cy.
196^. None
JbA_ 0.277
0.356 0C. .gor lower23. 6 @28V 4.5-4.7
Calculated M.B. OP-115
A My
'-rUivirAINrr
.it--CONF/DEN-TIAt
To be published M.B. OP-115
TRAN 007035
Toxicity (Civt Rtftrtnet)
Contact Medical PeptT
M.B. OP - l V 5
WATER PCB-SD0000041991
a.... PHYSICAL CONSTANTS DATA
"iUHTXNCI
1
ITNUCTUMAL FORMULA
AHOCLOR 1254
"-----------
TtJUPILID IV A. M. El.erbjrg
oat* 4-2S4?
0*0
Formula Molecular Weifht
naJme
Cl? Mt Cle,__________________ _32g^AvgJ__________________
SOURCE 0 DATE
--
Aootirance
.
Pale Y*>Lo lscoiia oil Monsar,:o Bui, np. li*MQsf
Polling Poll! M 760 m___ Rarge
Boulna Point M 3 m
"
365 *40l.oC lflQ^QgC__________________
II
Bfllllnf Point M Bo(line Point at
fnratalllziiu Point MeHint Point
bo
mm
,
. Non - erv st a L iz In c
II
Sol lAlonPolnl Specific Gravity
Specific Gravity Pounds per Gal. #
.____ __________________ 25/25''C,
C
1^538________________________ 1.49S-1.505 12.82
ii
SpAdf`rptlfir s ?/ 14/.*', MR
Coefficient ol Expansion 25-65uC. Refractive Index t i t)Prtn2 .
0 00088 cq/cc/wC. 1.6370-1.6390
Spf etflr.al ton 9/14/BS
Infra Red Spectrum (Rtfpenee)
Ultra Violet Spectrum (Refweneel
Viscosity
210 F
_ . _ 44-48 SUS
MB OP- 115
Viscosity a Sueloco Tonslon
Dvnes/cm
---------- p---------------------------------------50.3 @25C< 42.0 @100w
Sol Ubllitv In Water
- Insoluble
_ II
Soliillltv in 3A Alcohol @ 27VC
10 g. yioo.ee
II
Solubility In Pyridine 31C. . . 114 e. /100 cc
II
COMPANY'
CONFIDENTIAL
Flash Point Stf Vatewj c . o. c.
Fire Point C Heat of Contustion Heal of Formation
. .
e.o.c.
Us rmil Stillltv (caL/jra/mln.)
L*ent Heat of Fusion !
LMent Heat of Vac.__ _____r 1 /am.____________
Specific Heal
0 25VC.
Critical Temoerature
Critical Presttaa
_
Dissociation Constant
0
Specific Hf.P: |S 300'C.
None Non.e
50 0.261
0.336
Pour Pob.j .
Thermal Coi\ducUvlv. Cal/
* cpil^C/Sec.
*m*
mc
o
DlelecrtcCo'
100C.
o 6p cv.
o
~-12C. 99 D tq) 2ftr
4. 15-4.35
II H
Calculated MB OP-115
---------- n-------------------
ii
To be published
MR - OP -1 1 ** TRAN 007036
ToxIdtV (Civ* Reference)
Cori*acl Medical Depl.
M B - OP -11*.
WATER PCB-SD0000041992
D-.
r
PHYSICAL CONSTANTS DATA
WATER PCB-SD0000041993
I
....
PHYSICAL
`>U1TAMCI
COMPILED IV
CONSTANTS DATA
AROCLOR 1262
DAY I
ITKUCTUMAL FORMULA
CKJ Cl,
M/AME
Formuli Molecular Weight Appearance
C12H3CI7-----------------------------Llcht veil, sticky Resin
Bollinf Point 4 760 tun Bo tins Point at enj
39Q-425C___________________
Bflj liny Point 4 Bo line Point 4
aui rl
Cmtalllzlnt Point
Melting Point
,
Solution Point______________________________
Soeclfic Gravity 90/15 5C
-1577-JL..B87
Specific Gravity e 25>/25C
1.646
Pound* per Gil. 25 C Coefficient of Expans4op ;>.fi-6f>0O Reflective Index !2Rc i Infii Red Spectrum fRtiertnct)
_13JL2____________ ,,___________
0.00064 cc/cc/C 1.64R-1.650
.
Ultra Violet Spectrum ch*f**cc} '
Viscosity
2tnF
flfi-lOO SITS
yiscosltv
Surlace Tension Solitrlllty In Wier
Soliitllltv In
Solubility In
SOURCE a DATE Monsanto Bullet In OP- 1 r ^
" (1956
Specs. 4/11/55 _________________
11 fl
Specs. 4/11/55______________
COMPANY CONFIDENTIAL
Flash Point F (Htthod)
Fire Point C Heat of Conbustlon , Heat of Formation
Thermal Sttrllltv IcalAe/mlnJ_________________ IAent Host of Fusion ' Lient Heat ol Vac. Soeclfic Heal Critical Temperature Critical Prassue , Dissociation Constart Pour Point
None Nona*
35-38C
MB OP-115 II
* %m
oao wm
TRAN 007038
_
Toxicity (Gil* Rtfcr?ntt)
Contact Med. Dept. -
MB OP-115
NOTE: Tint* iolo tkeuId not t< rtltaiod omttidt of ttoiuanto Ckomitol Company, (fit additional ikli if Mtiiitrjr.
WATER PCB-SD0000041994
Dept, 246 - Process Description AROCLOR APPENDIX D
UTILITIES The utility calculations are based on design calculations for a 28.8 million pounds per year production rate. The breakdown of utility usage by individual equipment is only on estim&te. The estimates of utility usage are average values In most jLnstances as it is difficult to measure the operating time and load for a particular piece of equipment with great accuracy. The tptal usage of each utility was taken from the cost sheets. Estimates of individual operating time and percentage of the total load were made to calculate the distribution of utilities as given In the following pages of this section.
TRAN 007039
WATER PCB-SD0000041995
Dept, 246 - Process Description
AROCLOR
APPENDIX D
UTILITIES (Cont'd.)
1. Power Consumption
A. Electricity - 440 V,, 3 phase, 60 cycle
Item Equipment No. Motor
Motor HP
Peak
Load KW
101 Biphenyl transfer pump
103 Biphenyl head tank pump
104 Biphenyl feed pump
3.00 .75
7.50
2.6 0.7 b .6
Monthly Usage KWH
80
240
1980
^7 X S'
< S' A/ Ul ^Q 8k
O o
121 #5 Chlorinator pump 122 #4 Chlorinator pump 123 #3 Chlorinator pump 124 #2 Chlorinator pump 125 #1 Chlorinator pump 127 #2 Blow tank pump 129 #1 Blow tank pump 132 #1 still pump 135 #2 still pump 140 #1 Receiver pump 141 #2 Receiver pump 144 Blend tank pump 149 #3 Storage transfer pump 151 #4 storage transfer pump 153 #5 storage transfer pump 155 #8 storage transfer pump 157 #7 storage transfer pump 170 #1 city water pump 171 #2 city water pump 180 Exhaust blower
Ml see 11aneous Totals
10.00 8.8
10.00 8.8 10.00 8.8
10.00 8.8
10.00 8.8
5.00 4.4.
5.00 4.4
5.00 4.4
7.50 6.6
2.00 1.7
2.00 3.00
1.7 2.6
3.00 2.6
3.00 2.6
3.00 2.6
3.00 2.6
3.00 2.6
7.50 6.6
7.50 6.6
15.00 13.0 135.75 119.8
3040 3040 304 0 3040 3040
200 1580 1580 2340
20 20 200 160 240 200 80 80 2340 0 0 26,860
TRAN 007040
WATER PCB-SD0000041996
Dept. 246 - Process Description
AROCLOR
APPENDIX D
UTILITIES (Cont'd.)
1. Power Consumption (Cont'd.)
B. Electricity - 110 V., nne phase, 60 cycle
Peak Load
Equipment
KW
Lighting Instrumentation
15 2
Miscellaneous
3
Totals
20
2* Natural Gas
Item No.
Using Equ1pme nt
Normal Use S CFH
Peak Use SCFH
131 #1 Furnace
1200
132 #2 Furnace
1200
Totals
2400
2400 ' 4600
3. Compressed (plant) Air
Item No.
, Using Equipment
Normal Use SCFM
Peak Use SCFM
127 #2 Blow Tank
60
148 #3 Storage Tank 60
200 200
150 #4 Storage Tank 60
200
152 #5 Storage Tank 60
200
154 #8 Storage Tank 60
200
156 Hi Storage Tank 60
200
Miscellaneous Totals
10 37TT
200 T400
COMPANY CONFIDENTIAL
26.
Monthly Usage KWH
3600 l44o 2150 7190
Monthly Usage MSCF 430 430 B50
Monthly Usage
MSCF 2590
90 90 90 90 90 330 ~ymr
TRAN 007041
WATER PCB-SD0000041997
Dept. 246 - Pro-ceBs Description
AROCLOR
APPENDIX D
UTILITIES (Cont'd.)
4. N1trogen
Item No.
Using Equipment
Normal UBe SCFH
Peak UBe SCFH
142 #1 Blend Tank
143 #2 Blend Tank 146 #1 Product Tank 147 #2 Product Tank 14& #3 Storage Tank
150 #4 Storage Tank 152 #5 Storage Tank
Totals
3 3
3 3 3 3
4 4 4 4 4 4
4 28"
Purchase^ Water
Item No.
Using Equipment
Normal Use GPM
Peak UBe 0 PM
130 #1 Still
3
131 #2 Still
3
203 #1 Vacuum Jet
20
204 #2 Vacuum Jet
18
205 #3 Vacuum Jet
15
206 S-K Drowning Jet 25
MiBcellaneous
2
Totals
"58"
5 5 20 20 20 30
rn10r
High Pressure Steam
Item No.
UBing Equipment
Normal Use Lb ./hr.
Peak Use Lb ./hr.
167 #1 Blow Tank 203 #1 Vacuum Jet 204 #2 Vacuum Jet 205 #3 Vacuum Jet
Totals
210 450 400 325
1385"
310 70 .
615 500
7. Low Pressure Steam -----80 t'S'IO at 125^?
TRAN 007042
Item No.
Using Equipment
Normal Use Lb./hr.
Peak UBe Lb./hr.
102 Biphenyl Storage
700
Tank
138 #1 Receiver Tank 700
139 #2 Receiver Tank 700
142 #1 Blend Tank
200
143 #2 Blend Tank
200
146
#1 Finished Product
200
Tank
TVvt.B 1 R
27730"
900
900 900 300 300 300
3800
27.
Monthly Usage
SCF
2140 2140 2140 2140 2140 2140 2140 147980
Monthly Usage M. Gal,
150 150 870 770 650 120 100
2BT0~
Monthly Usage M. lb.
150 320 290 240
lOoO
Monthly .-Usage M. Lb.
500
500 500 150 150 150
T950--
COMPANY CONFIDENTIAL
WATER PCB-SD0000041998
28.
Dept, 246 - Process Description
AROCLOR
APPENDIX D
UTILITIES (Cont'd.)
Low Pres pure Steam (Cont'd
Item No.
Using Equipment
1^7 #2 Finished Product Tank
Normal Use
Lb .Air.
200
Peak Use Lb./hr.
300
Monthly Usage M. lbs.
150
148 #3 Storage Tank
700
900
500
150 #4 Storage Tank 152 #5 Storage Tank
700
700
900 500
900
500
154 #8 Storage Tank
700
156 #7 Storage Tank
700
Miscellaneous
1400
Totals
7800
900
900
2800 10,500
500 500 1000 5600
COMPAQ*confidential
[ TRAN 0070*3
WATER PCB-SD0000041999
( Dept. 246 - Process Description
29.
AROCLOR
,A,P, P--E--N---DrI--X E
PERS- ON"NE"L
Departments 246, A-246, B-246 and C-246 are closely related. Operating personnel may work In all of the departments
In a given day. For this reason, the description of operating classifications and assignments for departments 246, A-246, B-246 and C-246 Is given as though all four of the departments are Just
one department. .
Operating Classifications
Job
Premium Operator Second Operator Repairman Standard Operator Porter Swingman
Number of Men
7 day/week Schedule
10 & 4 schedule
43 43 11 22 i0
TOTAL
12* 9
The swingman works two shifts per week (Saturday and Sunday) as a relief
foreman, two shifts as a repairman, and one shift operating the premium
Job. There is an open shift on the second operator Job that is covered
by overtime. The premium operator and second operator cover three
shifts each 3ay. The repairman works the day shift, and with the swingman,
there is 7 days per week repairman coverage. Standard operators work the
day and middle shift 5 days per week. The porter works half time in
department 246 and half time in department 243, The premium operator has
lead responsibility for his shift.
The work foroe works all three departments Aroclor, Pyranol and Pydraul as one coordinated operation. The assignment of time is 70# to Aroclors, 15# to Pyranol and 15# to Pydraul.
Operating Assignments:
TRAN 007044
Premium Operator: Has overall responsibility and operates 5 chlorinators 2 stills and'covers the necessary absences of the standard operator.
Second Operator: Operates 2 blend tanks filter, 2 finished product tanks, storage1 tanks, makes Pyranol and Pydraul mixes, loads trailer, and tank cars, charges chlorinators and transfers receivers and also belongs to the Fire Brigade.
Repairman: Unloads cars'and trailers of Biphenyl, Trichlorobenzene and
Tetra-Trichlorobenzene and finished product, makes weekly safety mspectlc
*'
' J J * ** -- ..4 m
WATER PCB-SD0000042000
COMPANY CONFIDENTIAL
30.
Dept. 2U6 - Process Description
AROCLOR
APPENDIX E
PERSONNEL (Confd)
Standard Operator; FIIIb, BtencilB and labelB 5 gallon, 30 and 55 gallon drums and clean-up aBBlgnmentB when not drumming. The Standard Operator loads oars and trailers bb does the second operator.
Porter: Cleans office, control room, repair room, waBh room and smoking shelter.
Swlngman: Works one day per week bb premium operator, two days as repair man and two days as relief foreman. As relief foreman takes overall supervision on day Bhift on weekends including arranging for maintenance, night Bheets and line-up of work.
( TRAN 007045
WATER PCB-SD0000042001
Dept. 246 - proceBB Description
31.
AROCLOR
APPENDIX F
PACKAGING & SHIPPING
Aroclor, Pyranol & Pydraul and filled about half in drums and half in tank cars or tank trucks.
A substantial amount (about 4o) of Aroclor is used to make Pyranol and Pydraul.
Sales are largely directly to the customer. The remainder 1b in bulk shipments to the J. P. Queeny Plant.
All electrical grade tank truck shipments are made in the customers trucks whloh are stainless steel. Non-electrical Aroclors are shipped in leased truckB and may be iron although other materials
of construction are suitable. Pydraul is shipped in steel tank trucks,
Electrical grade Aroclor and Pyranole are shipped in solid aluminum lined tank carB or in lined tank cars either 4,000 or 8,000 gallons in capacity. The lining is either tin, zinc or aluminum spray because iron and iron oxide contamination is detrimental to the electrical properties, Electrical grade cars are either owned by Monsanto or on a long term lease. Non-electrical grade Aroclor is Bhipped in steel cars,
All electrical grade lota and bulk shipments of non-electrical material are sampled from the final container. That is all tank cars and tank trucks are sampled and analyzed after loading. All electrical grade drums are sampled from one of the drums.
Tank cars and tank trucks are inspected to be sure they are free of dirt and water or other foreign material before loading. Heels are drained before loading some materials. Car washing when necessary j 8 done by the repair track. Tank cars are sealed with a numbered
aluminum seal.
Lacquer lined drums are UBed for Aroclor and Pyranol and plain steel drums are used for Pydrauls.
A summary of products, weights and containers current use is as
follows:
Weights and Containers
Product
5 Oal.
3(5 OaT!
55 Gal,------ TT
TC
LU 1232
Q 1242
1248 ll 1254
55 60 -
60 --
1254 Xylene - -
O 1260 O 1262
60 60 -
MCS295
--
Pyranol 14B8 -" -
Pyranol 1481
-
-
600# 600#
600# 600# 600# * 600# 600#
645#
675# 675#
Yes Yes Yes
-
Yes -
_
Yes Yes Yes
-
Yes -
-
-
TRAN 007046
WATER PCB-SD0000042002
T
. Dept. 246 - Process Description
AR0CL0R APPENDIX F
PACKAQINO fc SHIPPING (Cont1'd.)
32.
Product
Weights and Containers
"r8al.
30 Oal.
35 aai.
TT
TC
Pyranol A-13B3B Inerteen PPO
65
60
360# 360#
Pydraul A-200 Pydraul 280
59 60 -
m
645# 625#
- 4000 Gal. - 4000 Gal. f
8000 Gal. Yes --
I
(
| i
_ '
COMPANY CONFIDENTIAL
TRAN 007047
WATER PCB-SD0000042003
T
Dept, 246 - Process Description
AROCLOR
APPENDIX 0
MATERIAL BALANCE
The material balance on Dept. 246 was made with a minimum of
field measurements. Moat of the estimates on the following page
oheck fairly close with actual raw material usages that can be readily measured. The exact composition of some of the inter mediate process streams is uncertain.
!
COMPANY CONFIDENTIAL
TRAN 007048
WATER PCB-SD0000042004
Dept. 246 - Prpcess Description
AROCLOR
Appendix a
summary of material balance results
AROCLOR 1242
Raw Material & Cost ($/lb.)
Usages - LbB/lOO lbs product Material Balance
Theory Material Balance
Usages lbs/lOO lbs
Biphenyl (.0662)
58
63 58 Finished Prod. 1 Filter Cake .
3.5 Still Bottoms .5 Off-QaB HC1
63.0
Chlorine (.0217)
84
91.8
42 Finished prod. 1.5 Filter Cake .05 Vacuum Jet 2.8 Still Bottoms .95 Alr-HCl Mix ture
44.50 Off-Gas HC1
91.80
*Ferric Chloride (.129)
0.03
*Attapulgus Earth (.0302) 15
*Air (.00055)
3
*Lime (.0100)
0.5
.03 .15
3 0.5
.03 .15 3.0
0,5
AROCLOR 1248
Biphenyl (.0662) Chlorine (.0217)
52
56.5
52 Finish Product
1 Filter Cake
3 Still Bottoms
.5 Off-Gas HC1
56.5
96
103.2
48 Finished Trod.
1.5 Filter Cake
.05 Vacuum Jet
2.55 Still Bottom:
.95 Alr-HCl Mix
ture
COMPANY CONFIDENTIAL
50^15 Off-Qas HC1 103.20
TRAN 007049
ThftRft raw materials are the same for production of all Aroclors.
WATER PCB-SD0000042005
Dept, 246 - Process Description
AROCLOR APPENDIX Q
SUMMARY OF MATERIAL BALANCE RESULTS (Cont'd.)
AROCLOR 1254
Raw Material & Cost
_Biphenyl (.0662)
Usages - Lbs/100 lbs product Material Balance
Theory Material Balance
Usages Lbs/lQQ Lbs
46
49.8
46 Finished Troduc
0.5 Filter Cake
2.8 Still Bottoms
0.5 Off-Gas HC1
' 49.8 `
Chlorine (.0217)
108
117.5
5^ Finished Produc 1 Filter Cake 0.05 Vacuum Jet 6.8 Still Bottoms 0.95 Air-HCl Mix ture
54.7 Off-Gas HC1
117.50
AROCLOR 1260
Biphenyl (.0662)
40
43.4
40 Finished Produc 0.9 Filter Cake 2.0 Still Bottoms 0.5 Off-Gas HC1
' 43.4
Chlorine (.0217)
120
128.8
60 Finished Produc 0.5 Filter Cake 0.05 Vacuum Jet 4.8 Still Bottoms 0.95Air-HCl Mix ture
62.50 Off-Gas HC1
128,80
COMPANY CONFIDENTIAL
TRAN 007050
WATER PCB-SD0000042006
36.
Dept. 246 - ProoeBB Description
AROCLOR
APPENDIX H
ATMOSPHERIC DISCHARGE - WASTE DISPOSAL
Discharge to Atmosphere
Lbs . per C lbs.
Total Lbs/Vr based on
of ,Aroclor Produced Prod. Rate 23.6 Jf lts/T
1. HC1 Fumes from blow tanks
0.01
2, 000
2. HC1 fumes from other tanks vented to atmosphere
0.01
2,000
3. Chlorine gas from chlorinator vented to blow tank
UNKNOWN
UNKNOWN
4. Aroclor & Biphenyl vapors of tanks vented to atmosphere
UNKNOWN
UNKNOWN "
Discharge to Sewers
1. HC1 from chlorinators
2.5*
500,000*
2. Cl-2 from chlorinators
2.0*
30,000*
3. Condensibles in chlorinator off-gas
2.0*
30,000*
Discharge to Waste Disposal
I. Montar
0.0176*
5,000*
2. Aroclor
0.33*
95,000*
Estimated
(
COMPANY CONFIDENTIAL
TRAN 007051
WATER PCB-SD0000042007
37.
Dept. 246 - Process Description
AROCLOR
APPENDIX I
PROCESS CONTROL
Sampling Point
Chlorinators
Frequency
2-3 times per batch
Reason for Normal
Sample
Range
Specific Gravity
Oil
Method Number
Blend Tanks
Storage Tank Composite
3 times each day
Every 1-2 days
Color (APHA)
50-150 Max.
Sp.Gr. at 25/15,C .011
Acidity (mg.KOH/g.) .014 Max.
Moisture (H2O) (PPM) 35 PPM Max.
Refractive Index at
25C
.0020
Inorganic(free)Chlorides .05 PPM
Max.
Dielectric Constant .20
Resistivity (500 VDC @
100C
500, Min.
O.l" GAP aB ohm-cm x
109
Hydrolysis Stability 1.0 PPM
TeBt (aB Chlorides)
Max.
Monsanto Stability
0.5 PPM
Test (as Chlorides)
Max.
Sulfates
None
Dielectric Strength at
25C
35 KV Min.
Viscosity at 100F
(SUS)
10
Thermal Chemical
0.75 PPM
Chlorides
Max.
Same as blend tanks
10,084 10,114 10,087 10,620
10,125 T-2092 11,608
11,607
T-2087.
11,503 12,169. 11,605 10,086 12,722
Tank Cars & Trailers
Every Load
Same as blend tanks
COMPANY CONFIDENTIAL
' >' ^
TRAN 007052 ( Tests made on electrical grade Aroclors only..
Tests made on request only. Special customer test. Maximum range for all Aroclors including electrioal and non-electrical
gradeb.
WATER PCB-SD0000042008
38.
Dept. 246 - Process Description
AROCLOR
.
APPENDIX J
SAFETY AND TOXICITY DATA
SAFETY EQUIPMENT
The following is a list of safety equipment (personal and departmental) required in department 246.
1. Fire extinguishers:
A. Dry Chemical (3) - Southwest corner Bldg. CR - Main Floor
- West wall at top of stairs of second floor.
B. Carbon Dioxide. Snow - Southwest corner of Bldg. CR, ground level.
2. Chlorine Qas Masks(4) - Southwest corner, second floor
- Control room, second floor
- East side, outside oontrol room
- Wall, Southwest corner of sprinkler house, main floor.
3. Scott Air Masks - West of Lean-To
4. Safety Showers (2) - Southeast corner of Bldg. CR, ground level.
- Southeast corner of Bldg. CR, 2nd floor.
5. DaviB Vapotester
6. Eye Baths 7. Sprinkler System
Safety Precautions
The following are safety precautions followed in the operation of department 24$.
1. Safety Equipment of Employee
Each employee has the following safety equipment: (1) hard hat
(2) sqfety glasses (3) goggles (4) rubber and canvas gloves
(5) rubber overshoes. Special equipment may be issued as necessary for performing a particular Job in a safe manner.
. COMPANY CONFIDENTIAL
TRAN 007053
WATER PCB-SD0000042009
t Dept. 246 - PpooeBB Description
39.
AROCLOR
APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
2. Sampling of Crude Aroclor
The pamples of Aroclor taken during the chlorination reaction
are hot (l70C). Precaution must be taken to avoid Bkin contact
of samples and inhalation of hydrogen chloride, chlorine and
aroc.lor vapors.
3. Fire.s
Fires may result from the ignition of leaking gas, xylene,
diphenyl, rags, paper, wood, etc. Automatic fire extinguishers
and sprinklers have been installed to combat fires..
.
4. ExplOBionB
Explosions may be cauBed from accumulated pockets of natural
gaB ior a rapid burning of Diphenyl in a clOBed container such as
a ohlorinator. ChlorinatorB are equipped with a 10" diameter
pressure relief line with a rupture dlBC madeto burBt at 22 psi
in case diphenyl within the ohlorinator ignites,
5. Toxicity
Toxici'ty does not present a Berious problem. However, a com
' plete daily change of clean clotheB 1b Bupplied to each person
and time is allotted at the end of each Bhift to take a bath.
Instructions are also iBsued to avoid actual skin contact with
Biphenyl and Aroclor as much as possible and to wash hands and
faoe before eating.
6. Miscellaneous There are many accidents that can occur that may be classified
SB health and Bafety hazards, These accidents may result from
Buch things as broken process lines, acid leaks, steam leaks,
etc.
The worst inherent hazards are as followb:
1. Free chlorine from ruptured line or major leak.
2. HC1 gas from ruptured line or major leak.
3. Dropping bottoms from Btills, 4. Hot aroclor and diphenyl.
COMPANY
Safety Recorc[
CONFIDENTIAL
The last lost-time injury in Department 246 was January 28, 1948. The frequency of minor injuries is low, around one per month.
Toxicity: This material is a liquid under normal conditions and has a medium toxicity range for liquid ingeBtion and high toxicity for vapor inhalation. The maximum allowable concentration (M.A.C.) is 1 mg/cublc meter.
Fire Hazard: There 1b no fire hazard under normal conditions. Aroclor mixes (Xylene, Toluene, Butyl Acetate, etc.) may burn and explode at high temperatureb when exposed to flameB.
TRAN 007054
WATER PCB-SD0000042010
-- T. |
1
Dept. 246 - Process Description
AH PC LOR APPENDIX J
' SAFETY & TOXICITY DATA (Cont'd.)
4o.
Other Hazards: This material can cause dermatitis, Bystemic poisoning from the fumes, and yellow atrophy of the liver. There are skin, mucous membranes and eye hazardB encountered in handling this material.
Treatment and Antidotes: Call a physician and remove patient from fumes.
Storage and Handling: Protect the skin, lungs, and eyes by wearing approved protective clothing, respirator, and goggles. People who handle
thiB material at elevated temperatures should have medical supervision, and the air should be sampled to.insure compliance with M.A.C. There are no special storage restrictions under normal conditions except store in a
ventilated area.
Shipping: There are. no special shipping restrictions.
FERRIC CHLOftlDE (FeC^)
Toxicity: ThiB material is a solid under normal conditions and is non toxic or has a rating as low.
Fire Hazard: There 1b no fire hazard under normal conditions, but it will emit toxic fumeB at high temperatures.
Other Hazards: Some people are allergic to this material and may develop skin rash, &nd there is an eye hazard.
Treatment and Antidotes: Call a phyBlclan.
Storage and Handling: Proteot the skin with approved protective clothing avoid the breathing of FeCl3 dust, wear approved respirator with adequate cartridge, and protect the eyes with approved goggles. There are no storage regulations.
Shipping: There are no shipping restrictions.
COMPANY
DirHENYL (CgHjCgHj)
CONFIDENTIAL
Toxicity: This material iB a solid at normal conditions and is medium toxic. The M.A.C. of vapor iB a 2 mg/cubic meter of air. If ingested, the lethal dose is 2.4 g/Kg of body weight. The fumes are not dangerousl deadly, but they are poisonous over a prolonged time.
Fire Hazard: Diphenyl iB very flammable and will burn when exposed to heat of flame or oxidizing materials (F.P. - 120C).
Other Hazards: Diphenyl is not too corrosive to skin, but it will affect the eyes.
TRAN 007055
WATER PCB-SD0000042011
Dept. 246 - Process Description
AROCLOR APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
DiniENYL (CgH^CgH^) (Cont'd.)
Treatment and Antidotes: Wash eyes with water and get the patient to Tresh air. Try"fTo get patient to vomit, and call a physician.
Storage and Handling: This material can be stored in steel containers away from fire hazards and oxidizing agents. Wear suitable clothes and approved goggles when handling diphenyl.
Shipping: Ship in cars or other suitable containers with a red warning
label of flammability.
'
XYLENE (C6H4(CH3)2
Toxicity: This material is a liquid under normal conditions and is very toxic in liquid or gaseous form, but it is less toxic than toluene. The M.A.C. is 200 ppm.
Fire Hazard: This material is very flammable and the limiting explosive concentration is 1-5.3$ by volume in air. It will also react with oxidizing agents (F.P. -85F).
Other HazaVds: ThiB material will cause necrosis if enough is inhaled, and is hazardous to eyes, mucous membranes, and the skin.
Treatment and Antidotes: Get patient to fresh air, and call a physician Tf Injestel3, get patient to vomit. Wash eyes and skin with water.
Storage and Handling: This material should be stored in a cool wellventilated area away from fire hazards or strong oxidizing agents. The material for storage can be steel cars or tanks. Wear approved protective clothing, respirator, and goggles.
: Ship in containers of steel or appropriate material with a
COMPANY
TRICHLOROBENZENE:
CONFIDENTIAL
Toxlelty: This material is a solid at room temperature and the vapors are quite toxio. The solid is poison if ingested. The M.A.C. is 50 ppir
Fire Hazard: This solid is flammable but is listed only as a moderate Tire hazard. Will burn at 420C or above.
Other Hazards: This material will affect the liver, eyes, and mucous membranes.
Treatment and Antidotes: Wash eyes with water, and get patient to fre3* air. Call a physician.
TRAN 007056
WATER PCB-SD0000042012
I
I I(
(
Dept, 2^6 - process Description
AROCLOR
APPENDIX J TRICHLOROBENZENE (Cont'd.)
SAFETY & TOXICITY DATA (Coni
Storage and Handling: Store this material in cool, well-ventilated area away fr<>m hazards and oxidizing agents. Wear protective clothing, chemical safe goggles and approved respirator.
Shipping: Ship in steel containers like cars or tanks with red label.
TETRA-TRI-CHLOROBENZENE
Toxicity: This material is a solid at normal temperatures and is medium
toxic. The M.A.C. of vapor is 50-75 ppm.
'
Fire Hazard: This material is not a very great fire hazard, but it will Hum at high temperatures and will decompose and emit chlorine.
Other Hazards: This material will affect the eyes, skin, and mucous membranes. ^
Treatment and Handling: Wash eyes and skin with water and get patient to fresh alr\i Call a physician.
Storage and Handling: Store this material in a cool place away from fire hazards and btrong oxidizing agents. This material can be stored in steel cars, tanks, or etc. Wear protective clothing, approved respirator, and chemical safe goggles when handling this material.
Shipping: Ship this material in containers marked with a red label.
LIME Ca(0H)2
Toxicity: Lime is not dangerously toxic, and it is regarded as more of a nuisance. This material is a solid or slurry.
Fire Hazard: This material is not flammable.
Other Hazards; Lime is very hazardous to the eyes. It will burn the skin also, and the duBt will affect the mucous membranes.
Treatment and Antidotes: Flood eyes and Bkin with large quantities of water. If lime is ingested, get patient to vomit and call physician.
Storage and Handling: Lime can be stored in steel containers, and people
should wear protective clothing, respirators, and rubber or chemical safe
goggles when handling lime.
Shipping: There are no special restrictions for shipping, but the containers Bhould have a white label, a caustic warning.
-
COMPANY
TRAN 007057
CONFIDENTIAL
WATER PCB-SD0000042013
AROCLOR
APPENDIX J
SAFETY AND TOXICITY DATA (Cont'd.)
ATTAPULGUS EARTH
Toxicity: This earth Is not toxic In general.
Fire Hazard: There Is no fire hazard.
Other Hazards: Attapulgus earth can create a dust hazard similar to other dusts that contain silica.
Treatment and. Antidotes: Consult a physician.
Storage and Handling: Attapulgus earth presents no special storage problem and should be handling by persons wearing an approved respirator.
Shipping: There are no special restrictions on shipping.
HYDROGEN CHLORIDE (HCl)
Toxicity: This material is a gas under normal conditions and is very Toxic.' The M.A.C. is 5-10 ppm and a concentration of 1500-2000 ppm would be fatal to humans in a few minutes.
Fire Hazard: There is no fire hazard under normal conditions, but wet gas reacts with some metals to form hazardous hydrogen.
Other Hazards: This material is hazardous to teeth, skin, eyes, and
muc ou s membranes,
Treatment and Antidotes: Wash profusely with water, if ingested, eat chalk, magnesium hydroxide, egg whites, and milk, and also administer
oxygen. Call a physician.
Storage and Handlingi This material should be stored in a cool, well ventilated arba away from oxidizing agents. This material can be stored in rubber lined, glass, or tantalum vessels. People handling this
material should wear suitable clothing like rubber aprons, shoes, and gloves. Also rubber goggles or chemical safe grades and approved pack
or canister gas masks.
Shipping: Shipping containers must have a white warning label and a
non-flammable label. Ship in appropriate containers Buch as rail car
or carboy.
COMPANY
CHLORINE (CI2)
CONFIDENTIAL
Toxicity: This material is a gas under normal conditions and is very toxlc. The M.A.C. Is .35 to 2 ppm. A concentration of 1000 ppm would be rapidly fatal. Least concentration with detectable odor is 3.5 ppm.
TRAN 007058
WATER PCB-SD0000042014
Dept. 246 - Process Description
AROCLOR
APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
CHLORINE (C12) (Cont'd.)
Fire Hazard: There is no fire hazard under normal conditions, but there
Is an explosion hazard if chlorine is mixed with a strong reducing agent such as hydrogen or hydrocarbons on high temperature.
Other Hazards: This material cauBeB eye, skin, and mucous membrane
Irritation.
'
Treatment and.Antidotes: The patient should be given oxygen Immediately and treated i'dr Bhock. Call^.a'physician.
Storage and Handling: ThiB material Bhould be stored in a ventilated and cool place away from fire hazards. When handling, wear a gas mask or approved respirator, clothing and rubber or chemical safe goggles. In strong chlorine concentrations, wear canister gas masks, Scott Air
Pack, or oxygen breathing apparatus.
Shipping: The shipping containers must have a green gas label and a non-flammable label on. Ship in steel cars or cylinders.
COMPANY . CONFIDENTIAL
TRAN 007059
WATER PCB-SD0000042015
Dept. 246 - ProceBB Description
AROCLOR
APPENDIX K
BACKGROUND INFORMATION
*5.
The manufacture of Aroolors was developed quite by chance. The Indian Refining Company, in the latter part of 1926, approached the Swann Chemical Company located in Anniston, Alabama, regarding the production of Biphenyl which the Indian Refining Company wanted to UBe as a heat transfer medium. The Swann Chemical Company agreed to produce Biphenyl, but first a process had to be/developed.
Two years later, in 1928, a pilot plant for producing Biphenyl became operative. However, in the meantime, the Indian Refining Company dropped all interest in Biphenyl. Since a process had been developed for manufacturing Biphenyl, the Swann Chemical Company
started looking for other outlets for this material. The simplest outlet was in the form of Chlorinated Biphenyls which were produced in the laboratory in 1929.
The Chlorinated Biphenyls produced exhibited good electrical proper
ties. This was reported to the General Electric Company who
immediately beoame interested in the product which ultimately
developed into large scale consumption in electrical transformers
and capaoitors,
.
The trade name "Aroolors" was adopted for the Chlorinated Biphenyl products. The properties of Aroclors vary from mobile oily liquids to fine white crystals and hard transparent reBins, The excellent electrical properties, fire resistance and inertness of the Aroclors
make them useful for many applications.
Plant equipment was installed to produce AroclorB at a rate of 3000 pounds per day or 1 million pounds per year. In the following years, this production rate waB insufficient to meet the increases sales requirements.
The Swann Chemical Company was purchased by the Monsanto Company in 1935. This purchase gave Monsanto access to the patent rights for the production of Aroclors.
Production capacity needed to be expanded, and since Monsanto had a chlorine plant as "Plant B" (now called the W. G. Krummrich Plant), the Aroclor production was transferred from the AnniBton Plant to the MonBanto, Illinois Plant, where operations at an increased
productive capacity Btarted in September, 1936.
By 19*10, the Krummrich Plant production capacity was inadequate, and in 1941, a similar production unit was installed in the Anniston Plant.
COMPANY CONFIDENTIAL
TRAN 007060
WATER PCB-SD0000042016
Dept, 246 - Process Description
*
AROCLOR
APPENDIX L
TIME CYCLE
The design capacity of the department is 2,400,000 pounds per mbnth or 28,800,000 pounds per year.
Figure 1 of this section illustrates the flow pattern of the Aroclor process and lists the approximate time needed to complete each process step. The time table for the Aroclor prooess is summarized below:
Operation
Time (hours)
Equivalent pounds of Finished Product.
Charge Chlorinator
Chlorination
1242
1248
1254
1260
Transfer to blow tanks
Aeration
Distillation
1242
1248
1254
1260
Blending
Filtering
Dropping to Storage
.25 6.00 8.00 10.00 12.00
.25 2,00
1.75 1.75 1.75 1.75 2.00 2.00 2.00
6400 7200 8040
9100
The time required to make completed batches of the various Aroclors are tabulated below:
Aroqlor TSVg 1248 1254 1260
Batch Time (hrs,) ---------17.55' --------
18.25 20.25
21.25
Process operations including filter press cleaning, sampling, etc., are Independent of the batch completion time cycle because production time
is not lost.
COMPANY CONFIDENTIAL
TRAN 007061
WATER PCB-SD0000042017
Dept, 246 - Process Description
AROCLOR
APPENDIX M
QUALITY CONSIDERATIONS
The Aroclor compounds are among the most versatile chemically-made materials in industry. Aroclors are useful In many ways because
of their outstanding inertness.
Aroclors are used alone for particular physical Jobs such as insulating, heat transfer, sealantB, and expansion media; and they are used as components or extendorB in elastomers, adhesives, paints, lacquers, varnishes, pigments and waxes,
Aroclors must be highly pure, with dependably minimal traces of
electrolytes for use in electrical applications. Electrical grade
Aroclors must pasB numerous stringent specifications. The following
tests determine Aroclor quality:
._
Hydrolysis Stability
Measure of chemically unstable chlorine compounds.
Munch or Monsanto Stability Test
Measure of thermally unstable chlorine compounds at elevated temperatures.
Thermal Chemical Chloride
Developed by the General Electric
Company to measure chemically and thermally unstable chlorine compounds.
Resistivity
Measure of inBulative properties.
Power Factor
Measures power loss due to current through a capacitor.
Dielectric Constant
Measures the capacitance of a standard such as air compared to
the capacitances of Aroclor.
Speoific Gravity, Refractive Index
Measures of chlorination level.
The stability and electrical properties of electrical-grade Aroclors are paramount in quality considerations. The chlorination step of the process is moBt critical because many properties of the final product are determined by the properties of the crude Aroclor. Conditions in the chlorinator needed for a good quality product are:
1. Chlorination Temperature - The chlorination temperature must
be greater than 120'-'C within 30 minutes from the beginning of the chlorination reaction to produce stable AroclorB. Results of Research tests indicate that product stability is better as the Initial chlorination temperature is increased.
.
COMPANY
TRAN 007062
, CONFIDENTIAL
WATER PCB-SD0000042018
Det_i_2^_6_^P0es_De^cr^ltlon
48.
APPENDIX M
QUALITY CONSIDERATIONS (Cont'd.)
2. Ferric Chloride Concentration - Research has found that the Ferric chloride concentration must be at least 0.03# to fonn stable products. Research recommends 0.05# ferric chloride.
Lower catalyst ratios result in increased "addition" chlorina tion as opposed to "substitution" chlorination, indicated by higher chloride values and lower yields.
The isomeric distribution of the final product is a function of the type and concentration of the catalyst used In the reaction.
Homogeneous suspension of the catalyst Is extremely important.
Good catalyst contaot cannot be attained without homogeneous
suspension. Since ferric chloride does not mix well with
biphenyl, the dry catalyst must not be poured into the
chlorinator.
.
.
3. Geometry of Reacting Vessel - The shape of the reactor affects the circulation and flow pattern of the reactants. It is suspected that the chlorine gas channels through a void space in the existing catalyst basket. This problem is presently
being studied.
The reactor must be designed such that circulation of reactants is rapid and homogeneous and local over-chlorination does not occur.
4. Cleanliness - The ferric chloride settles to the bottom of the cHTorinator. Areas of the packed bed become plugged with ferric chloride and channeling of reactant flow may result.
A steam clean-out of the chlorinator may be an expedient metho-: to remove the ferric chloride. This method was tried In the department, and evidently was successful. Further tests by the laboratory will verify the effectiveness of a steam clean
out.
Sparging - The sparger controls the gas distribution under the catalyst hold-up plate and the size of gas bubbles, it is not known whether the catalyst basket or sparger or both are the critical factors In achieving the proper flow of gas through
the reactor. It is believed that the sparger should distribute small bubbles giving good gas distribution throughout the chlorinator. The small bubbles have a greater surface area per unit volume of gas for mass transfer and this should Increase the reaction rate.
Raw Material Purity - The purity of raw materials can affect the quality of Aroclors. Sulfates are particularly harmful in the chlorine gas. It is suspected that sulfates poison
I the ferric chloride catalyBt and sulfates some of the biphenyl.
If the ferric chloride catalyst is poisoned, the effective catalyst concentration is reduced and thus unstable aroclors will be produced. The chemistry and mechanism of catalytic
poisoning are not known for certain. Sulfonated biphenyl is carried over during distillation and is not removed by earth treatlng.
TRAN 007063
WATER PCB-SD0000042019
Dept. 246 - Process Description
AROCLOR
APPENDIX M
QUALITY CONSIDERATIONS (Contd.)
6. Raw Material Purity (Cont'd.)
Sulfonated biphenyl has ionic properties which lowers the resistivity of the finished product. A Brink Mist Eliminator has been installed in Dept. 246 to eliminate the chlorine impurities.
7* Earth Treatment - The factors affecting stability also inTTuence the electrical properties of Aroclors. An absorbent will be ineffective if the Aroclor was not prepared in a manner such that a stable product was formed during the chlorination reaction.
However, research has found that absorbents are very effective for improvement of electrical properties by removing ferric chloride and tars carried over durirg distillation, provided the crude Aroclor has good stability.
The absorbent used in Dept. 246 (after distillation) is Attapulgus Earth, the concentration should be 0.5# for Aroclor 1242 and 0.1# for other Aroclors. The earth must be heat treated at 250C for a minimum of 4 hours before addition to the Aroclor. Heat treatment reduces the moisture and activates the earth.
8. Lime Treatment - It is important that proper amount of lime (250 Ipounds per still run) be added to the still to prevent sublimation of ferric chloride.
9. The blend tanks, finished product tanks, and Aroclor 1242 and 1254 storage tanks are blanketed with nitrogen gas. Nitrogen blanketing maintains the electrical properties of the Aroclors by preventing corrosion of the equipment.
In summary, the chlorination step of the process is the most critical. A good quality Aroclor cannot be produced if a stable compound is not formed during chlorination.
Once a stable compound is formed, other techniques such as UBe of lime, absorbents, and nitrogen blanketing are used to maintain and improve electrical properties.
TRAN 007064
WATER PCB-SD0000042020
( 50.
Dopt. 246 - Process Description
AROCIiOR
APPENDIX M
QUALITY CONSIDERATIONS (Cont'd)
Absorbents - Numerous absorbents have been screened in the laboratory at various contact temperatures for their effect on resistivity of plant untreated Aroclor 1242.
The most satisfactory absorbent pound for improving the resistivity
of Aroclor 1242 was LVM attaBorb. Table I of this Bection lists
the laboratory resultB of the different absorbents used to treat
Aroclor 1242.
.
Degradation of AroclorB
Degradation of AroclorB, which leads to loss in electrical resist ivity, is one of the short comings of using Aroclor as a dielectric, expecially since only a very minor degradation can cause a serious breakdown in electrical equipment.
The thermal degradation of fractionated Aroclor has been measured at 2fpOC arid the amount of Hydrogen Chloride liberated was measured. The results of these tests are llBted in table II of this section.
Aroclor 1242 haB been degraded by ultravlolent light, and the decrease in electrical resistivity with Irradiation time was measured. The plot of resistivity verBUB concentration is a curve for a weak electrolyte. It 1b possible to remove the conducting material brought about by photo-degradation, and restore the resistivity of itB original value by paBBing the degraded material over activated alumina.
Thermal degradation of AroclorB is minor compared to photo chemical degradation. Thermal treatment causes release of a small amount of hydrogen chloride initially, but thiB evolution ceases after a short time. Such behavior 1b attributed to thermal degradation of impurities. If Aroclor iB irradiated, then exposed to a thermal treatment, appreciably more HC1 is liberated.
COMPANY CONFIDENTIAL
TRAN 007065
WATER PCB-SD0000042021
Dept. 2kS - Process Description
AROCLOR
AFrENDIX M
QUALITY CONSIDERATIONS (Cont'd.)
51.
TABLE I ADSORBENT SCREENINQ DATA
COMPANY CONFIDENTIAL
Adsorbent
Adsorbent Pretreatment
Contact
at lOi
Temperature C ohm-cm, x :10C
LVM Attapulgus Earth
LVM Attapulgus Earth
IMV Attapulgus Earth
LVM Attapulgus ( Earth
Attasorb - LVM
None
Heated at 250C 12 HourB
Heated at 350C 12 hours
Heated at 350C 4 hours
None
Attaclay
None
Activated Alumina (Alcoa Orade F-3
325 mesh)
None
Voclay 325
None
(Western
Bentonite)
Panther Creek
None
(Southern
Bentonite)
Filtrol Orade 1
None
Zeolex 7
None
(Zeolite)
Florite 60 mesh
None
(Activated Bauxite)
{
Suprex L-Q (Kaolin)
None
AttaBorb - LVM
Heated 35 CPC
12 hours
Attasorb - RVM
None
60 80 100 120
60
80
100 120
60
80 100 120
60
80 100 120
60
80 100 120
80 100 120
60
80 100
120 80
100 120
80 100
120 80 80
100
100 .
100
100
3400 2000 2800 2900 4200 6400
7200
6100 9300
9000
6300 6300 2400
9600 6000
5700 9700 12,100 13,700 17,800 10,200 5400 6000 2100 2500 2800 . 3300 5100 3800 9700 6200
11,300
8100
2600 7000
3600
4500
12,200
16,200
<0
r<o0 oo
WATER PCB-SD0000042022
Dept. 246 - Process Description
52.
AROCLOR
APPENDIX M
QUALITY CONSIDERATIONS (Cont'd, )
Adsorbent
TABLE I (Cont'd.)
Adsorbent Pre treatment
Contact Temperature C
Volume Resistivity
at 100C ohm-cm. x 10C
Unde Molecular Sieve Type 4-A
None
60 2100
Laminar Alumina
None
60
900
Note: Resisvitity of Aroclor before treatment = 1 x 10^ ohm-cm.
COMPANY CONFIDENTIAL (
TRAN 007067
WATER PCB-SD0000042023
( Dept. 246 - Process Description
53
AROCLOR
APPENDIX M
QUALITY CONSIDERATIONS (Contd.)
. TABLE II
THERMAL DEGRADATION OF AROCLORS AI 250C
Aroclor 1221
1232
12*] 2 1248 1254
gm. of HCl/gm x 10^
3.35 6.73 . 11.07
3.91 6.42 9.81
'
5.96 9.58 13.00
3.61
5.44 8.48
3.43 3.96 6.43
Heating Time
1 hr. 2 hrs. 5 hrs.
1 hr. 2 hrs.
5 hrs.
1 hr. 2. hrs.
5 hrs.
1 hr. 2 hrs.
5 hrs.
1 hr. 2 hrs.
5 hrs.
'
COMPANY CONFIDENTIAL
(.
TRAN 007068
WATER PCB-SD0000042024
{.
I
i
! ^
Dept. 246 - Process Description AHOCLOH
j
APPENDIX N MISCELLANEOUS
! I
/
REFERENCES
'
1. St. Louis Report No. 2694, 'Job No. 171-1Q28, February 15, 1952.
Title: Operation of Arocjor Stills At Increased Pressure
For Increased Ratr.-B
t. .
Summary: Distillation runs were made at 20 to 30 mm Hg. The rate of distillation of 1200 series Aroclors increases with pressure.
2. St. Louis Report No.'2755, Job No. 2-02-760.01 - 3948-3 March 6, 1961.
Title: Improved Aroclor 1242 Studies
Summary:
Studies were carried out to determine the effect of temperature, chlorine content, and catalyst concen tration in chlorinated biphenyl mixtures. 2,4-dichlorobiphenyl is the percursor of the high dielectric constant, trlchlorlnated components.
3. St. Louis Report No. 2072, Job No. 2-02-750.01-3428, May 4, 1958.
Title: Final Report on Aroclor Process Studies.
Summary:
Purity of raw materials, catalyst concentration,
reaction temperature and rate of chlorination were the variables Btudies with respect to their influence on the stability of the finished product.
4. St. Louis Report No. 2540, Job No. 171-6l6, December 28, 1958.
Title: The Effect of Prolonged Heat on the Electrical Properties of Aroclors.
COMPANY confidential
Summary: Aroclors 1232, 1242, 1248 and 1254 were held at 130C. The power factor was periodically measured.
5. St. Louis Report No. 2234, Job No. 171-451, June 14, 1956.
Title: Evaporation Loss of Aroclors.
Summary: The evaporation Iobb of Aroclors was determined at 100C under Btatic conditions.
TRAN 007069
WATER PCB-SD0000042025
i
Dopt. 246 - ProceBB Description
55
AROCLOR
APPENDIX N
MISCELLANEOUS (Cont'd.)
REFERENCES (Cont'd.)
6. St. Louis Report No. 2790, Job No. 171-1026, July 3> 1952.
Title: Increased Producticn of Aroclors by More Rapid Rate
of Chlorination.
_
Summary: Chlorination rate was Increased from 400 pounds per hour to 770 pounds per hour. Aroclors produced at Increased rate was within specifications,
7. St. Louis Report No. 1842, Job No. 2-02-750.01-3368
J\jly 12, 1957.
.
Title: Use of Ferric Chloride as Catalyst for production of
( Aroolor 1242.
\
Summary: The comparison of stability chloride values revealed no difference between the product made with iron turnings as catalyBt and ferric chloride as catalyst.
8. St, Louis Report No. 2096, Job No. 2-02-750.01-3202, June 6, 1958.
Title: ResiBistivity Improvement of Aroclor 1242.
Summary:
Numerous absorbents were screened at various contact temperatures for their effect on resistivity of plant untreated Aroclor 1242. Heat activation of Attapulgus Earth was also studied.
9. E. E. Martin, OPERATING INSTRUCTIONS FOR DEPT. 246.
W. G. Krummrich Plant, 19bl.
"
10. E. E. Martin^ PROCESS DESCRIPTION FOR MANUFACTURE OF AROCLORS, l^U^^
11 E. Mather, PROCESS DESCRIPTION FOR MANUFACTURE OF
AROCLORS, 19551
COMPANY
( CONFIDENT' M
TRAM 007070
WATER PCB-SD0000042026
V Dept. 246 - PrQceBB Description
56.
AROCLOR
APPENDIX N
MISCELLANEOUS
The following table shows the results of tests which measured the evaporation losses of the various Aroclors.
Aroclor
Evaporation Rate pms/cm2/hr ./100C
Aroclor 1221
.00174
Aroclor 1232
.000874
Aroclor 1242
.000338
Aroclor 1248
.000152
Aroclor 1254
.000053
Aroclor 1260
.0000088
Aroclor 1262
.0000132
From the above results, the evaporation rate for Aroclor 1262 is greater than that of Aroclor 1260. This unexpected result may be explained by some difference in the conditions of whj ch the two lots were prepared.
The reaction products in Biphenyl Chlorination differ with the type of catalyst used* Results of research investigations are listed below:
Catalyst
Fe C3 0 Sb Clo Ti cii Sn ClIj
Isomer Distribution of Aroclor 1232 2 - 4 - 2,2 1 - M-l 2,4' - '4,4'
15*
11
11
24
7* 0.7
0
1
15*
20
20 16
6* 38*
3.6 38
2.2
46
2.3 38
11* 38 14
18
tri
9* 9 7 1.3
COMPANY CONFIDENTIAL
{
TRAN 007071
WATER PCB-SD0000042027
( Do'pt, 246 - Process Description
57.
AROCLOR
APPENDIX N
MISCELLANEOUS (Contd.)
Some of the typioal operating difficulties in department 246 and possible remedies arc given below:
CHLORINATORS
Trouble
CauBe
Remedy
ChlorinatorB operating
against too much back pressure
Plugged off-gas lines
Open lines and steam them out. Dry out lines with air before resuming operation.
Chlorinator Blow in
1. Low chlorine
1. Call chlorine
picking up gravity
pressure or low
dept, for more
chlorine gas
gas
concentration
2. Check biphenyl
2. Wet biphenyl
storage tanks for
1 moisture.
BLOW TANKS
Blow tanks stacking off
Operating chlorinators with vent open
Close chlorinator ventj possibly re duce air to blow tanks
STILLS
Not enough vacuum
1. Ejectors not pull ing properly
2. Coke scrubber contains water
1. Check ejectors
2. Drain coke scrubber
36" SPARKLER FILTER
Foreign material in filtrate samples
Dirty filter or broken paper
Clean and re-paper press
COMPANY ( - CONFIDENTIAL
TRAN 007072
WATER PCB-SD0000042028