Document Vj9BE5RDmNNmx6O7rq8xpzxXN
INDUSTRIAL HYGIENE AND TOXICOLOGY*
MUB8-000669
1=3
=3
M
GULF OIL CORPORATIONMEDICAL DEPARTMENT PITTSBURGH. PA.
JUNE 1974
BULLETIN
INDUSTRIAL HYGIENE STANDARD NO. 25A
OCCUPATIONAL SAFETY AND HEALTH ACT STANDARD FOR EXPOSURE TO ASBESTOS DUST
Attached is a copy of the OSHA Standard 1910.93a for Exposure to Asbestos Dust as printed in the Federal Register on October 18, 1972. Some of the most important aspects of this regulation are highlighted below:
1. AIR SAMPLING
(a) Employee exposures (see Table I) must have been monitored at all locations where asbestos fibers are released to the atmosphere to determine whether exposures are within limits.
(b) At intervals no greater than 6 months, employees whose exposure to asbestos may reasonably be foreseen to exceed the criteria, must be re monitored .
(c) The following types of air samples should be collected:
(1) Personnel monitoring - 15 to 30 minute samples to determine peak concentrations (not to exceed 10 fibers/cc).
(2) Long-term samples from 90 to 480 minutes to determine the 8-hour time weighted average (TWA) (not to exceed 5 fibers/cc) concentrations.
(3) Environmental monitoring in the general work area to determine the 8-hour TWA concentrations.
GULP 6209
Replacement for Industrial Hygiene Standard No December 1972
25A, dated
03114727
PIAINTIFF'S 1 ; EXHIBIT I
urn-gift |
HUBB-B8Q6693
4
Page 3 5. ASBESTOS SUBSTITUTES
No asbestos-bearing insulation materials (except mastic or asphalt base materials) should be used in new installations or as replacement material in existing plants. Please see the attached list of substitute materials (Table II) and asbestos-free products in use by Gulf (Table III). 6. ATTACHMENTS (a) Table I -- Typical Asbestos Handling Practices (b) Table II -- Asbestos-Free Substitutes (c) Table III -- Asbestos-Free Products Currently
In Use By Gulf (d) Table IV -- OSHA Standard for Exposure to
Asbestos Dust 1910.S3a
i =
001147^3 t
INDUSTRIAL HYGIENE AND TOXICOLOGY^
aUBB-flO066
GULF OIL CORPORATION MEDICAL DEPARTMENT PITTSBURGH. PA.
June, 1974 INDUSTRIAL HYGIENE STANDARD NO. 25
BULLETIN
THERMAL INSULATING MATERIALS
PRODUCTS CONTAINING ASB2ST05------
INTRODUCTION
The modern mass production of hundreds of natural and synthetic materials, such as asbestos, has brought the need to protect workers from certain health risks, known or suspected.
Manufacturers of Thermal Insulation Products containing asbestos have for years been taking protective measures to eliminate excess ive exposures to inhalation of dusts that may be injurious.
The OSHA Asbestos Exposure Standard now in effect states that the 8-hour time-weighted average (TV/A) airborne concentrations of asbestos fibers to which any employee may be exposed shall not exceed 5 fibers longer than ^m per cc of air. In addition, the ceiling concentration above which no employee shall be exposed at any time is 10 fibers longer than 5^m per cc of air.
Note that effective July 1, 1976, the TWA concentration is reduced to 2 fibers from the current 5 fibers longer than ^im per cc of air.
(See OSHA 9310.93a, section (a) Definitions, (b) Permissible Expo sure to Airborne Concentrations of Asbestos Fibers).
Based on the fact that all materials can be handled safely, the National Insulation Manufacturers Association recommends the follow ing practices for handling and applying Thermal Insulation Products containing asbestos and/or other potentially injurious materials to protect the worker. A section on demolition has been added, taken from Environment Protection Agency Asbestos Emission Standard 40 CFR 61, dated May 1974.
CONTRACTORS
Insulation contractors and applicators are urged to study these recommended practices carefully and to see that they are observed by all workers handling insulation materials. As with Safety Regu lations, it is in the interest of both contract employer and contract employee to see that health protection practices are strictly observed.
Replacement for Industrial Hygiene Standard No. 25, dated 6209 February 1969
03114731
M U BB-aaaifi95
Page 3
debris off cartons. Repack odd lot pieces. Close cartons.
Fabrication in Warehouse and Job Site Shops
(See OSHA 1910.93a, Section (c) Methods of Compliance, (2) Mark Practices, i) Wet Methods.
v=3 1. Open and remove the material from cartons with care.
& 2. Handle and stack pieces of material in a manner that will
avoid generating dust and breakage.
3. Mechanical dust collecting systems adequately designed to remove dust at the source should be installed on power-
a operated, fixed and portable equipment in the warehouse shop and/or in the job site shop.
4. All machines should be furnished with suitable waste contain
& ing equipment for the collection of scrap and waste to pre vent the material from falling on the floor and generating
dust.
5. Shop-fabricated pieces of Thermal Insulation such as fittings, segments, etc., should be placed in containers. Care should be taken when handling these pieces during piling, stacking, and packing.
6. Containers should be closed after packing and remain closed until the material is used.
Application Procedures
1. Unpacking and application of the material should be done in a manner that will minimize airborne dust.
2. Avoid dropping, throwing, or unnecessary rough handling of
insulation materials.
'
3. Keep floors and surfaces clean of scrap, shavings, and debris. Put unusable material into waste containers immediately.
4. Hand sawing, cutting, jacket stripping, etc., should be done in a manner that will create minimal airborne dust. Use of proper methods and tools will help considerably towards dust
abatement.
5. When working in confined spaces, portable dust collectors or exhaust blowers should be provided to remove dust from the source.
6. If conditions prevent collecting or exhausting dust from the source, use exhaust blowers to provide general air changes in the room.
7. Avoid exhausting into other working areas.
03114733
NUBB**0006696
Page 5
7. Wet the material and mix into a slurry as quickly as possible. 8. When mixing cement in a confined space where proper ventila
tion is inadequate, respirators should be worn.
Cleaning
1. Bag breakage, cleaning up dry cement and discarding bags at the mixing area should be done in the same manner as recom mended under Warehousing, Storage, and Handling*
2. Wet down tools, mortar boxes, wheelbarrows, mixing containers, and any spillage before scraping and cleaning.
3. Cements should be handled wet whenever possible. Wet material will create no dust problem.
SPRAYING OF THERMAL INSULATION
(See OSHA 9310.93a Section (c) Methods of Compliance, (2) Work
Practices ii) Spraying Demolition or Removal.
Spraying Areas
Spraying of Thermal Insulation Products containing asbestos re quires special precautionary measures. Refer to the Sprayed Mineral Fiber Manufacturers Association for Sprayed Fiber Appli cation Practices.
1. The equipment and machinery to be sprayed should be shielded by adequate wind breaks and, where practicable, drop cloths to prevent excessive dust and contamination in adjacent areas.
2. Workers not engaged in the spraying operations should wear
respirators when entering an area within 15 feet of the spray
ing machine, nozzle or equipment.
-
3. Where Sprayed Fiber Application Practices cannot be followed and excessive airborne dust is generated, it is recommended that portable mechanical exhaUst ventilation be used to remove airborne dust. Exhaust must be located to avoid con tamination of other occupied areas.
^ CN
Application
1. All. personnel in the immediate area engaged in the machine feeding and spraying operation should wear respirators, whether in confined or open areas, ventilated or not venti lated .
2. Respirators should be worn after the spraying operation has been concluded and until the generated dust concentration has cleared.
03114735
HWBB-0006697
Page 7
3. Where applicable, portable mechanical exhaust ventilation should be used to remove airborne dust.
4. Avoid unnecassary rehandling of scrap.
5. Locate truck, dumpster bucket or final disposal equipment as close to stripping site as possible. '
6. Wet down scrap material before shoveling, hauling, or dumping.
7. Do not permit accumulation of scrap and debris on floor and
other surfaces.
"
8. Vacuum equipment is recommended for cleaning up during and after stripping.
Other Workmen
1. Personnel not involved in the stripping and tearing off operation should not be permitted in the stripping area.
2. If it is essential for other workmen to be in the work area,
respirators should be worn by them.
DEMOLITION
The following is quoted from the EPA Asbestos Emission Standard 40 CFR 61 as revised May 1974.
61.21j
"Demolition" means the wrecking or removal of any load supporting structural member.
61.22c 2 i '
Friable asbestos materials, used to insulate or fire proof any boiler, pipe, or load-supporting structural member, shall be wetted and removed from any building, structure, facility, or installation subject to this paragraph before wrecking of load-supporting struc tural members is commenced. Boilers, pipe, or load supporting structural members that are insulated or fireproofed with friable asbestos materials may be removed as units or in sections without stripping or wetting, except that where the boiler, pipe, or load supporting structural member is cut or disjointed, the exposed friable asbestos materials shall be wetted. Friable asbestos debris shall be wetted adequately to insure that such debris remains wet during all stages of demolition and related handling operations.
61.22c 2 ii
No pipe or load-supporting structural member that is covered with friable asbestos insulating or fire proofing material shall be dropped or thrown to the ground from any building, structure, facility, or installation subject to this paragraph, but shall be carefully lowered or taken to ground level.
03114737
table: i
NO
Produce S Manufacturer
ASBESTOS-FREE SUBSTITUTES
Thermal Conducti'-it Btu/hr/fc2/F/ in.
Composition
ea C3Q
Price Limits F 4/Board
A.F. Uniblock, Holmes Insulations, Ltd.
0.50 ? 400 F 0.84 g 1 000 F
Mineral Wool and
1,900
Glass Fibers _ >
37 CL
Carey Temp 2000
0.70 500 F
0.76 0 7 50 F 0.84 0 1,000 F
Calcined ' ^ Diatomaceous Silica with Glass Fibers as Binders
2 000
39.3 LCI 34.8 CL
H.T. Block - 48
0.42 g 400 F
Forty Eight Insulations, Inc. 0.90 | 1,200 F
Mineral Fibers
1,900
36 LCI 28 CL
MF Pipe - 48
0.30 g 300 F
Forty Eight Insulations, Inc. 0.50 g 700 F
Mineral Fibers
1,200
884/lin ft-6" p
Hew Carey Temp 1S00
0.42 g 300 F 0.64 700 F
Expanded Perlite
1, 500
40.2 LC 35.7 CL
1200 Block - 48
0.30 @ 300 F
Forty Eight Insulations, Inc. 0.52 | 700 F
Mineral Fibers
1,200
20 LC 15 C'
Super Cal Temp. HA (rabco Industrial Products)
0.40 ? 300 F 0.67 C SCO F
Uncalcined
1 200
Diatomaceous Earth
6 Mineral Fibers
28 CL
Unibest Pittsburgh Corning Corp.
0.41 3 300 F 0.65 g 700 F
Mineral Fibers
1 500
40 LC 32 CL
LCL - Less tran Car Load Lrs. CL - Car Load Lora
GR&DC ESD(WFK) 11/2/71
-1-
sstra
Material Designation
TABLE II ASBESTOS-FREE PRODUCTS
Manufacturer
Max. Temp. F
c* Os sq a ea 00 Composition
J-M Microlite
Johns Manville
J-M Microtex
Johns Manville
J-M Microlok
Johns Manville
J-M 1000 Spin-Glas
Johns Manville
J-M Cerafelt
Johns Manville
J-M Zelie LW
Johns Manville
Aerotube (Armstrong Cork)
Johns Manville
57 Adhesive (Armstrong Cork) Johns Manville
.
Banroc (Keene)
Monobloc (Keene)
Fiberglas Aerocor Fiberglas Boards AF-530 Fiberglas Pipe Covering Fiberglas Blanket Fiberglas AF-530
Johns Manville
Johns Manville
Fiberglas Canada, Ltd. Fiberglas Canada, Ltd. Fiberglas Canada, Ltd. Fiberglas Canada, Ltd. Fiberglas Canada, Ltd.
350 350 500 1,000 2,300 2,000 220
1,000
1,700
450 450 600 950 450
Fibrous Glass Fibrous Glass Fibrous Glass Fibrous Glass Fibrous Glass Kaolin - 70% Expanded rubber Synthetic rubber, phenolic resin, toluene, naphtha Mineral wool and metal Mineral wool and clay
Glass fibers with phenol formaldehy binder
^arey Temp
Carey Temp 2,000
Thermoglas Pipe Covering Careytemp Adhesive
Philip Carey
Philip Carey
Philip Carey Philip Carey
1,500 2,000
350
Expanded perliteglass Fibers, clay and' phenolic Binders Fibrous adhesive
Foamglas Foamthane
Tab-lok
Pittsburgh Corning Pittsburgh Corning
Eagle Picher
800 (- 300 to 200)
1,400
Cellular Glass Rigid Polyurethar
Mineral wool witt phenolic binder
Sauereisen No. 31
Sauereisen Cements
2,000,
Silica base and sodium silicate
Lumnite r.2>
Universal Atlas
2,600
Alumina, titania silica and calci oxide
Resco AA-22 Resco RS-5A
Resco RS-7
Resco RS-17-A
Resco Products Resco Products
Resco Products
Resco Products
3,400 2,700
2,100
3,400
Alumina and P0e; Alumina, silica and CaO Alumina, silica and CaO Alumina and CaO_
-2- 03114740
Material Designation
Plicast XL Mix L.W.I. - 20 L.W.I. - 24 Super Air Bond Super "F"
Narcospar Narcocrete Narcocast ES Anti Erode
TIW Insulation Type 1 Fiberglas IS-Board Aircor 75P
Kast-O-Lite 2,500 F
Castable 20 2,000 F Fireclay - Mortar Greencote Greencast 12 KS-4V SK-7
Gj.*sc--Therm 70
Style 4301 Blanket Super 44 Cement
No. 1C Insulation
Super Powerhouse Cement
Perlite
Purolite 22
Duracrete G-ES
K 50wo 1
Kaocrotc - B
Kaocrote 2600 LI
TABLE II
ASBESTOS-FREE PRODUCTS
(cont'd) Manufacturer
Max. Temp F
Plibrico Canada, Plibrico Canada, Plibrico Canada, Plibrico Canada,
Plibrico Canada,
Ltd. Lea. Ltd. Ltd.
Ltd.
2,9G0 2,000 2, *50 3,200 2,800
North American Refractories North American Refractories North American Refractories
North American Refractories
3,100 2,450 2,400 2, 500
Owens Corning Osrens Corning Owens Corning
1,000 850 250
A. P. Green
2, 500
A.P. Green A. P. Green A. P. Green A. P. Green A. P. Green A. P. Green
American Gilson:te
2,000 1.000 3,000 2,200 2,600 1,800
460
Forty-Eight Insulation Forty-Eight Insulation
Forty-Eight Insulation
Keene Corporation
1, 600 1,900
1,200
1,200
Perlite Industries Canadian Refractories
2, 350 2,200
Canadian Refractories
2, 600
Babcock c* Wilcox
Babcock 5 V.ilco> Babcock >. Wilcox
2, 300
. "T
Composition
Alumina Silica, CaO, Ti02, Na~0 FejOj and MgO
Si02, AI2O3, CaO
Fe203, Ti02, MgO, in varying amounts
Fiberglas Fiberglas Fiberglas
Si02, AI2O, Fe2^*3> CaO . T1O2, MgO
Si02> AloO-i Si02, AI2O3, CaO Si02>, AI2O3, CaO
Powdered bituminous coal
Fiberglas Mineral Fibers and binders Mineral fibers and binders Mineral wool and Portland cement
Expanded perlite
Fireclay, perlite and calcium aiuminate Fireclay, calcium and aiuminate
Alumina-s ilica cerami< riber calcined alumina-s 1 Li ca Aggregate and calcium Aiuminate-
JMIfiB-0006700
-3-
03114741
TABLE II ASBESTOS-FREE PRODUCTS
ar-N
Material Designation
Speed Crete, Blue Line
Light Weight Castable - 22 Harchrome G Harwaco Bond Superplastic Firebrick Thermolith
Moldit 45 Moldit 58 Moldit 80 RSI 1199
Foster Lagtone Coatings
Ccont'd) Manufacturer
Max. Temp F
CO 5 Composition s
Cement Materials Corporation
85 Cement based silic
Harbison-Walker Refractories Harbison-Walker Refractories Harbison-Walker Refractories Harbison-Walker Refractories Harbison-Walker Refractories
2,200 2,600 2,900 3,000 3,000
Si02, A1203, CaO '
Fe2C>3, Cr203 Ti02 and MgO
RSI Ramtite Canada, Ltd. RSI Ramtite Canada, Ltd. RSI Ramtite Canada, Ltd. RSI Ramtite Canada, Ltd.
2,200 2,200 2,500 1,800
Si02, A1203, CaO,
Fe23 Cr23> Ti02 and MgO
Benjamin Foster Company
ISO Polyvinyl acetate and plasticizer and ethylene glycc glycol ether acetate, water
Thermo-12
Johns Manville Corp.
1, 500
asbestos free calcium silicate --
11/4/71
-4-
03114742