Document Vj86d89vzG4r2QqVVNXvEE8aj

t packaged cast iron boilers from American-Standard oil-fired boiler three sizes net ratings: 86,300, 112,500 & 138,800 Btuh model DH-5 Arcoflame oil burner light-sensing flame detector two-tone brown & beige jacket gas-fired boiler three sizes net ratings: 75,000, 101,300 & 127,500 Btuh approved for all gases A.GA approved for close clearance installation two-tone brown & beige jacket packagedoil-fired boilers APH rati ngs bailer number gross l = B = R output (Btu/hr) 1net = B= R ratings (Btu/hr) l=B=R burner capacity (gph) chimney size (inches) height (feet) . water content (gallons) approx. shipping weight (pounds) APH-115 APH-150 APH-185 115,000 ISO,000 185,000 86,300 112,500 138,800 1.15 1.45 1.80 8x8 8x8 8x8 15 15 15 3.4 4.4 5.4 Nozzle sizes, gph, furnished with APH packaged boilers: APH-115, 1.10-60* S; APH-150. 1.35-60' S; APH-185, 1.75-60* S. Net I = 8 = R ratings shown include allowance for normal piping and pick up load. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements. 330 375 420 dimensions number boiler of number sections APH-115 APH-150 APH-185 3 4 5 dimensions (inches) AB 37 31V 40 34V. 43 37Va * ; v ; .. i packaged;gas-fired: bailers; GPH ratings boiler number for installations from sea level to 2000 ft. A.G.A. ratings input (Btu/hr) output (Btu/hr) net l = B = R ratings (Btu/hr) number of burners input per burner (Btu/hr) chimney diameter (inches) height (feet) content (gallons) natural, mixed or manufactured gases GPH-100 125,000 100,000 75,000 6 20,830 6 20 4.5 GPH-135 168,750 135,000 101,300 8 21,095 7 20 5.5 GPH-170 212,500 170,000 127,500 10 21,250 7 20 6.5 IP gases GPH-100 120,000 96.000 72,000 6 20,000 6 20 4.5 GPH-135 160.000 128,000 96,000 a 20,000 7 20 5.5 GPH-170 200,000 160,000 120,000 10 20,000 7 20 6.5 For altitudes above 2000 ft., ratings should be reduced at the rate of 4% for each 1000 ft. above sea level. e Net 1 = 8 = R ratings shown include allowance for normal piping and pick up load. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick up requirements. approx. shipping weight (pounds) 315 358 399 315 358 399 dimensions -el 0 k- O boiler number GPH-100 GPH-135 GPH-170 number of sections 4 5 6 dimensions (inches) AB C O 43Vz 45V4 48V. 24V. 27V. 30V 18 21 24 6 7 7 1*--isw-- side view APH and GPH packaged boil ers are designed and built to comply with the American Society of Mechanical Engi neer's Code, and bear their ap proval symbol. Ratings have been approved by the Institute of Boiler and Radiator Manufacturers. The Model DH-5 Arcoflame Oil Burner is listed by the Underwriters' Laboratories, Inc. for No. 1 and No. 2 fuel oil; complies with Com mercial Standard CS-75; and is approved by the New York City Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts, and by the Department of State Police, State of Connecticut. GPH boiler ratings have been ap proved by the American Gas Association for alT gases. The GPH boiler also bears the American Gas Association approval for instal lation on combustible flooring and for close clearance installations. Form No. 293-2 AMEiucAN-^tandard PLUMBING AND HEATING DIVISION AMERICAN RADIATOR & STANOARD SANITARY CORPORATION 40 WEST 40TH STREET NEW YORK, N Y. 10018 00351 . **' 0 - u s