packaged cast iron boilers
from American-Standard
oil-fired boiler
three sizes net ratings: 86,300, 112,500 & 138,800 Btuh model DH-5 Arcoflame oil burner light-sensing flame detector two-tone brown & beige jacket
gas-fired boiler
three sizes net ratings: 75,000, 101,300 & 127,500 Btuh approved for all gases A.GA approved for close clearance installation two-tone brown & beige jacket
packagedoil-fired boilers
APH rati ngs
bailer number
gross l = B = R output (Btu/hr)
1net = B= R
ratings
(Btu/hr)
l=B=R burner capacity (gph)
chimney
size (inches)
height (feet)
. water content (gallons)
approx. shipping
weight (pounds)
APH-115 APH-150 APH-185
115,000 ISO,000 185,000
86,300 112,500 138,800
1.15 1.45 1.80
8x8 8x8 8x8
15 15 15
3.4 4.4 5.4
Nozzle sizes, gph, furnished with APH packaged boilers: APH-115, 1.10-60* S; APH-150. 1.35-60' S; APH-185, 1.75-60* S. Net I = 8 = R ratings shown include allowance for normal piping and pick up load. American-Standard should be consulted before
selecting a boiler for installations having unusual piping and pick up requirements.
330 375 420
dimensions
number
boiler
of
number sections
APH-115 APH-150 APH-185
3 4 5
dimensions (inches)
AB
37 31V 40 34V. 43 37Va
* ; v ; ..
i packaged;gas-fired: bailers;
GPH ratings
boiler number
for installations from sea level to 2000 ft.
A.G.A. ratings
input (Btu/hr)
output (Btu/hr)
net l = B = R ratings (Btu/hr)
number of
burners
input per burner
(Btu/hr)
chimney
diameter (inches)
height (feet)
content (gallons)
natural, mixed or manufactured gases
GPH-100
125,000
100,000
75,000
6
20,830
6
20 4.5
GPH-135
168,750
135,000
101,300
8
21,095
7
20 5.5
GPH-170
212,500
170,000
127,500
10
21,250
7
20 6.5
IP gases
GPH-100
120,000
96.000
72,000
6
20,000
6
20 4.5
GPH-135
160.000
128,000
96,000
a
20,000
7
20 5.5
GPH-170
200,000
160,000
120,000
10
20,000
7
20 6.5
For altitudes above 2000 ft., ratings should be reduced at the rate of 4% for each 1000 ft. above sea level. e Net 1 = 8 = R ratings shown include allowance for normal piping and pick up load. American-Standard should be consulted before
selecting a boiler for installations having unusual piping and pick up requirements.
approx. shipping weight (pounds)
315 358 399
315 358 399
dimensions
-el 0 k-
O
boiler number
GPH-100 GPH-135 GPH-170
number of
sections
4 5 6
dimensions (inches)
AB C O
43Vz 45V4 48V.
24V. 27V. 30V
18 21 24
6 7 7
1*--isw--
side view
APH and GPH packaged boil ers are designed and built to comply with the American Society of Mechanical Engi neer's Code, and bear their ap proval symbol. Ratings have
been approved by the Institute of Boiler and Radiator Manufacturers.
The Model DH-5 Arcoflame Oil Burner is listed by the Underwriters'
Laboratories, Inc. for No. 1 and No. 2 fuel oil; complies with Com mercial Standard CS-75; and is approved by the New York City
Board of Standards and Appeals, by the State Fire Marshal of the Commonwealth of Massachusetts, and by the Department of State Police, State of Connecticut. GPH boiler ratings have been ap proved by the American Gas Association for alT gases. The GPH boiler also bears the American Gas Association approval for instal lation on combustible flooring and for close clearance installations.
Form No. 293-2