Document VaJ3LjoyvOXvm42Dmex8MQQq
UNITED STATESUNITED STATES ENVIRONMENTAL PROTECTION AGENCY
*REGION 1
ENVIRONMENTAL
AGENCY5 POST OFFICEB OSSTQOUN,A RMAE ,0 21S0U9-I3T9E12
100
PROTECTION
Date:Dated as shown on electronic signature(s)
Subj:Inspection Report
Clean Water Act - National Pollutant Discharge Elimination
System (" NPDES ")
12, 14, and 24 South Hunt Road
From:Stephanie Tougas, Inspector STEPHANIE Digitally SsTiEPgHnANeIdE TbOUyG
AS
TOUGAS
Date: 2024.07.23 10:48:06
-04'00 '
Thru:Ray Putnam, Inspector
To:File
I. Facility Information
A. Facility Name:12, 14 & 24 South Hunt Road
B. Facility Location:24 South Hunt Road
Amesbury, MA 01913
C. Facility Contacts: Chad Haynes, Site Superintendent
ARCO Design / Build, General Contractor
chaynes@arcodb.com
Paul Perkins, Excavation Foreman
Onyx Corporation, Contractor
18 Wetherbee St.
Acton, MA 01720
perkins@onyxcorporation.net
Global Property Developers Corp. and Marcus Partners, Inc.
Developers
Munters Corporation
Tenants
D. NPDES ID No (s).: MAR1004RO
ED_019088A_00012466-00001
II. Background Information
A. Date(s) of inspection: July 1, 2024
B. Weather Conditions: clear, 80 degrees F
C. US EPA Representative(s):
Stephanie Tougas
Ray Putnam
D. State / Local Representative(s):
None
E. Federally Enforceable Requirements Covered During the Inspection:
Construction General Permit
F. Previous Enforcement Actions:
None
III. Type and Purpose of Inspection
Evaluation
IV. Facility Description
The construction site is located on the south side of South Hunt Road. The site disturbs
approximately 34 acres of earth. The project is the construction of a 435,000 square foot
manufacturing facility to house HVAC products and associated entrance road and
parking area for the company Munters Corporation. The site is heavily sloped: the
entrance to the site steeply slopes upward from South Hunt Road to the top where the
manufacturing facility and associated parking lot is being constructed. Surrounding large
sections of the north and south sides of the facility are retaining walls with the facility
structures at the top of the wall and existing grade at the bottom. The site slopes down
along the west and south sides. A large detention basin is located in the southwest portion
of the site. Wetlands are mapped south of the site, beyond which is the Merrimack River.
V. Inspection
I called Mr. Chad Haynes the morning of the inspection requesting site access.
We arrived at approximately 10:00 AM.
A. Opening Conference
We met Mr. Haynes and Mr. Perkins at the trailer located on the north side of the facility.
I presented my credentials and explained the purpose of the inspection. I explained that
we were following up on a tip we received alleging there were some issues with erosion
2
ED_019088A_00012466-00002
control on the site. Mr. Perkins and Mr. Haynes explained that sediment had discharged
into the wetland area south of the site, and they had recently been remediating it by
removing the sediment and putting down a wetland seed mix.
I asked them to explain how they handle the erosion control inspections required by the
CGP permit. Mr. Perkins said that Onyx conducts these inspections weekly as well as
after a storm event. I asked for a copy of two months'worth of these inspections and the
SWPPP, and Mr. Perkins emailed them to me on the spot. Mr. Perkins said Onyx is
responsible for correcting any deficiencies. Mr. Perkins said that the Conservation
Commission conducts inspections, as well as an additional third party, EcoTec, Inc. Mr.
Perkins showed us the construction plans and a recent aerial photo taken by their drone
and explained the layout of the site, and showed where the detention basins were located
and where the wetland remediation took place. Mr. Haynes said they recently completed
the detention basin in the last few weeks, and that they recently installed the sand in the
basin.
B. Facility Tour
Mr. Haynes accompanied us on the site walk, beginning counterclockwise along the north
side towards the detention basin. The slopes had been hydroseeded, and we observed the
two inlets into the forebay that Mr. Haynes explained drain the north and south sides of
the site, respectively. We observed the newly constructed detention basin and noted the
sand bottom that was recently installed.
We continued walking along the detention basin, along the west side towards the south.
We came to a steeper slope in the southwest corner. Mr. Haynes said they had had some
issues with this corner in the past, but since installing additional silt fences in tandem,
and installing jute netting and seeding the slopes, there hadn't been any recent issues with
breaching the silt fences. I reminded Mr. Haynes of the permit condition that silt fences
with more than half sediment accumulation need tending to. This section had multiple
rows of silt fences, none of which were breached. He also said that they are planning to
plant 100 trees along this slope.
Continuing the site walk along the south side, we noted a temporary basin, as well as
slopes stabilized with stump grindings and gravel. We observed a heavily rip - rapped
gulley with an outlet leading downslope into the wooded area. There were check dams in
this gulley as well. The emergency spillway to the detention basin outfalls at the top of
the rip - rapped gulley. Mr. Haynes said he has not seen overflow since the detention basin
was completed.
We came across an area where the silt fence was not properly functioning, and Mr.
Haynes said he would inform Onyx of this problem right away. We then walked into the
woods, down an existing trail towards the wetland remediation that Mr. Haynes said they
had removed sediment from that had discharged and laid down a wetland seed mix.
Inspector Putnam and I noted some Phragmites growing in the remediation area.
3
ED_019088A_00012466-00003
We walked back upslope and continued the perimeter walk. We came to the southern
retaining wall and walked along the bottom. There were a few areas where the silt
fencing needed attention. Mr. Haynes said he would inform Onyx of these areas as well.
Back up on the parking lot, now beginning to walk north and downslope, Mr. Haynes
explained that under the parking lot is perforated PVC piping surrounded by rock at the
bottom of the footing of the building that ties into the storm drain. I observed a catch
basin they recently opened up and are installing an oil and debris trap structure into.
There was a large stockpile at the edge of the parking lot along the west side of the paved
entrance, which Mr. Haynes said contained high levels of naturally occurring arsenic, so
they are hauling most of it offsite.
We walked downslope, observing more catch basins. We observed workers pumping out
the catch basins as we walked. We came to the point where Mr. Haynes explained that
these catch basins and all the ones downslope towards South Hunt Road receive
stormwater from the site and instead of discharging to the detention basin we observed
earlier, they feed into the soccer field filtration system. All the catch basins along the
entrance road had drain guards installed. The soccer field is located downslope along
South Hunt Road and is technically part of a separate project. Mr. Haynes said that that
site is developed by Global Properties and that they have a stake in the 24 South Hunt
Project as well. The soccer field system discharges the stormwater to a wetland across
South Hunt Road and then into Route 495 storm water system.
At the entrance of the site, in the northwest corner, was another detention pond. Just
below that detention pond, right along South Hunt Road, is a wetland. Mr. Haynes said
that there is an inlet in the wetland that discharges to the wetland across South Hunt
Road, which we walked across the road to observe. Mr. Haynes explained that they had
had some issues with the catch basins by the entrance to the site not functioning properly,
which he partially attributed to the DOT accidentally crushing one of the catch basin lines
during a road sign installation, or due to the roadside ditch along Route 495 continuing to
back up.
I walked along the entrance, looking at the various signs that were posted on the fence. I
told Mr. Haynes that I did not see any sign indicating the NOI number or how the public
could request a copy of the SWPPP. Mr. Haynes said there had been a sign, but it was
recently removed during some work and he would have it put back up right away.
We walked back up towards the trailer. I observed a swale along the large slope, and
another gravel swale along the bench of the slope. This swale had a catch basin that
discharged to the soccer field storm system.
C. Closing Conference
Back at the trailer, I reiterated that there were some areas where the silt fences needed
correction. I explained that we cannot make any conclusions in the field if any actions
will result from this inspection, but that we would be in touch shortly. I told Mr. Haynes
4
ED_019088A_00012466-00004
that we would follow up with an inspection report within 60 days. We thanked Mr.
Haynes for his time and departed the site at approximately 11:45 AM.
Unless otherwise noted, this report describes conditions at the facility / property as
observed by EPA inspector(s), and / or through records provided to and / or information
reported to EPA inspector(s) by facility representatives and as understood by the
inspector(s). This report may not capture all operations or activities ongoing at the time
of the inspection. This report does not make final determinations on potential areas of
concern. Nothing in this report affects EPA's authorities under federal statutes and
regulations to pursue further investigation or action.
Photo
location
on mapFile nameDescription
1 20240701_142127754_iOS.jpg Site map
20240701_143410924_iOS.jpg
Area along north side of manufacturing
2 facility
20240701_143555544_iOS.jpgStanding on slope looking down at forebay to
3detention basin
420240701_143634094_iOS.jpgSlope recently seeded
20240701_143703909_iOS.jpginlet to forebay draining stormwater from
5north half of site
20240701_143723187_iOS.jpginlet to forebay draining south half of site and
69
east parking lot
7 20240701_143817541_iOS.jpg infiltration basin
8 20240701_143821119_iOS.jpg infiltration basin
9 20240701_143856507_iOS.jpg outfall structure
20240701_144120718_iOS.jpg
area at toe of slope with multiple rows of silt
10-fences
20240701_144204822_iOS.jpg
11area to be planted with 100 trees
20240701_144332008_iOS.jpg
12same area with reinforced silt fences
20240701_144435371_iOS.jpganother area along toe of slope with multiple
13rows of silt fences
20240701_144715220_iOS.jpg
14slope with rocks and stump grindings
15 20240701_144752515_iOS.jpg temporary basin
1620240701_144752838_iOS.jpgsame photo as 15
17 20240701_144918719_iOS.jpg overflow outlet
50
ED_019088A_00012466-00005
20240701_145010618_iOS.jpg
18looking upslope of overflow outlet
1920240701_145129761_iOS.jpgarea newly hydroseeded
20240701_145149904_iOS.jpg
area along south side with silt fences needing
20 attention
2120240701_145200410_iOS.jpgsilt fences that need attention
20240701_145325581_iOS.jpg
path into woods towards wetland
22 remediation
20240701_145419006_iOS.jpg
23following path, stabilized with mulch
2420240701_145457634_iOS.jpgwattles along path
2520240701_145611751_iOS.jpgwetland remediation area
26 20240701_145651025_iOS.jpg accident photo
20240701_150254612_iOS.jpg
27vegetated slope along south side
20240701_150332286_iOS.jpgarea downslope of retaining wall that needs
28 attention
20240701_150356859_iOS.jpganother area downslope of retaining wall on
29south side needing attention
20240701_150417738_iOS.jpg
30gravel slope downslope of retaining wall
20240701_150524191_iOS.jpg
area where silt fence needs attention along
31south side
Slope recently seeded above the retaining
20240701_150702785_iOS.jpg
32 wall
3320240701_150747673_iOS.jpgsome debris on the slope
20240701_150855337_iOS.jpgcatch basin on site that will feed into forebay
34of detention pond
stormwater filter structure to be installed in
20240701_150906366_iOS.jpg
35catch basin
20240701_150956879_iOS.jpg
36sloped along road, swale with inlet structure
20240701_151124194_iOS.jpgparking lot beneath which there is pvc
perforated pipe covered in rock that ties into
37storm drain
20240701_151359664_iOS.jpg
stock pile to be hauled out shortly - has
38 arsenic
3920240701_151507906_iOS.jpgcurb being built
Catch basin that ties into soccer field filtration
20240701_151605309_iOS.jpg
40 system
6
ED_019088A_00012466-00006
20240701_151759485_iOS.jpg
41Area not part of 24 S Hunt project
20240701_152053120_iOS.jpg
42Area not part of 24 S Hunt project
20240701_152135829_iOS.jpg
43slope to be hydroseeded again
44 20240701_152229420_iOS.jpg diversion berm
4520240701_152259557_iOS.jpginstallation of electrical pipes
20240701_152455587_iOS.jpg
46detention ponds along west side of entrance
20240701_152548095_iOS.jpg
47wetland across S. Hunt Rd. that has outlet in it
20240701_152647237_iOS.jpgsilt socks around catch basin that feeds into
48wetland across S Hunt Rd
wetland that has outlet but is not
20240701_152657533_iOS.jpg existing
49 visible
50 20240701_152822466_iOS.jpg entrance
51 20240701_152825158_iOS.jpg entrance
5220240701_152840513_iOS.jpgMADEP file number
20240701_153115225_iOS.jpg
swale along base of slope going to install
53check dams
20240701_153229598_iOS.jpg
54bench of slope with catch basin
catch basin drains to soccer field infiltration
20240701_153251536_iOS.jpg
55 system
7
ED_019088A_00012466-00007