Datai 12-15-48 Materials Aroelors and Pyranols Method No. 10,126-48
f) SElHOH
W.g.ir. beot. No. 246
Refs
Tests Corrosion and Chemical
Stability
^age 1
This test is run on Aroolors 1260 and 1254 and Pyranols 1467, 1481,
and 1478 (TCB)
1. Roll a 1-g. rectangular piece (ca. 2 in. x 4 in.) of aluminum foil so
that it will pass through a S 24/40 Joint. Be careful that after rolling the specimen does not touch itself at any point.
2. Wash the aluminum foil scrupulously, with acetone, distilled water, aoetone, benzene, and chloride-free ether, place on a clean watch-glass,
and dry in an oven at 110C. for 30 minutes. After cleaning, handle the specimen with tongs or forceps only.
3. Weigh the aluminum foil at room temperature ( / 0.00005 g.)
4. Drop the weighed specimen into the chloride-free corrosion flask of the "G.E. Corrosion Apparatus." Rinse out flask with sample and rinse
end of condenser with sample.
5. Add 200 ml. of sample to the aluminum foil.
6. Set the corrosion flask in the corrosion test apparatus.
7. Attach a 12- inch straight-tube air-cooled condenser, the outside of which is painted with aluminum.
8. Cover the exposed part of the flask with aluminum foil.
9. Heat for 6.0 / 0.1 hours at 210C. / 5C. Detach condenser from the flask before removing the flask from the hot plate. (Cover the flask with aluminum foil when the flask is not in use.
10. Without removing the foil analyze the Aroclor or Pyranol sample , remaining in the corrosion apparatus for (a) appearance, color, and oondition (Method No. 10,084)> (b) inorganic chlorides (Method No. 10,118), and (c) acid number (Method No. 10,087).
11. With a pair of clean, straight nichrome tongs, remove the aluminum
foil specimen, wash thoroughly, dry and weigh (/ 0.00005 g.) as before (steps 2 and 3).
Report the loss or gain in weight to the nearest 0.0001 g. and the anaylsls of the Aroolor in the same manner as reported for the original material.
Notes)
1. The corrosion flask is a 300 ml Pyrex flask with a 34/4? g.g. joint
and the oondenser is a 12-inch straight-tube air-cooled condenser to
fit, painted with aluminum.
Corrosion and Chemical Stability Mathod No. 10,126-14.8
Page 2
Notes (Cont'd)
2. 0. E. Corrosion Apparatus consists of a transits box 32 in. long by 8 in. wide by 5 inches deep. The top of the box consists of a split transits board with holes out to fit the flasks. The box is heated by two 500-watt, 15 volt Q.E. strip heaters with offset terminals at one end (23" overall length). The heating length is covered by. a copper strip 194 in. long, I4 in. wide, and 1/4 in. thick. The temperature is controlled by an automatic thermostat with temperature setting indicator.
-Pled from WOK Procedure Manual 3-30-56
Jb
Notes and amendments given to W.B.P. bv telephone
1. In Section 2>
Order of foil washing!
benzene alcohol acetone no water
Time in drying oven!
10 minutes
2. a.,.gectligifl. 7
Length of condebser!
18 Inches
Condenser wrapped with foil instead of painted
TOWOLDMONOQ57523