Document VKoZgjwjRv1mkgMkbdLXb36bZ

* G201 Elements Change Control W. Link . Fnrn : General Order Engrg. ' WIN : Date : March 22, 1973 Street: PACE 260 . . S.O. 13A4541 G.O. 3CT98716 ' HP Cylinder insulation cc: .G201 Elements Change Control - S. Jones A301 Product Manufacturing Engineering - W. McQuire W102 A302 G201 A305 A201 Erection 6 Test - R. Castaldo ` Project Drafting - P. Serino Elements Drafting - A. Budko . Product Development. - B. Brown Product Manufacturing Engineering - R.. Quinn Ref: ,R. Quinn's letter dated March .20,. 1973. Also reference- M. L. Wolpert's letter dated Eebruary 26, 1973 (copy attached). - ' .. . Before agreeing 'to Mr. Quinn's suggestion of providing blankets (which are more expensive) X would suggest an investigation be __ made of the block Insulation that Is used on the.erection floor to.determine if it contains any asbestos material. Mr. Volpert's . letter indicates that block and plastic insulation is available that does not have any asbestos content. If our drawings in^ dlcate that we are using block Insulation that does contain asbestos I recommend that the drawings be changed to Indicate - the ones that are acceptable in Mr. Wolpert's letter. ' ds Attachment T- J * ' * 4 %.$. JijuULLuLKjc^AJ J. A. Giuliucci, Project Engineer General Order Engrg.-North ' ftwv :S* T. Materials Engrg. ww 1325-4884 tea :February 26, 1973 .Subject: insulation Materials -O : o. in'-- A-404 GOE Projects South A-403 Frame Engineering ' A-101 PGS Installation Service -G-201 HP-IP Elements -- ' G-201 LP Elements .: <3-201 Valves and Hydraulic Controls .G-201 Service Project Engineering G-201 Service Analysis Engineering- N-202 Small Steam Turbine Elements cc: G-201 Materials Engineering A-203 Standards Engineering A-404 GOE Projects A-404 GOE Projects" --------------------- . R&D Center Inorganic'Materials sSW9WjtcheM J. D. Dickinson H. M. Owens J. H.'Goumas kS. L. Jones . J. J. Hart , J. W. Ross R. W. LeGates G. F. Hyde ... J. S. Bonk " > ' -. M. Schmerling ^ M. Dorfman R. M. Laub --JvHr-Stnrges -- K. W. Grossett Steam Turbine Division Materials Engineering has been requested Jfco__approve non-asbe.stos turbine insulation materials as replace- ments for materials that contain asbestos "In order to bypass th elaborate precautions required by OSHA. 1 have'initiated a ten' program and I will be evaluating the new insulation materials that we are proposing. . . ` .-- - - . The proposal for Eliminating Asbestos Insulation Materials is attached. In some cases,for a particular materialspecification' there is a breakdown by manufacturer where some suppliers' insul ation contains asbestos and others do not. In other cases where all suppliers' insulation material contains asbestos (e.g. asbestos cloth) the material specification gets a direct substitute. There are two specific materials that should be discussed further. M10130BJ wire is being replaced by M10730DX wire because it has been objected to by some customers. We can not propose a replace ment for M53351DU paste at this time. This is the only asbestos .material that has ."continue to use" status. The manufacturer claims there .is no possibility of asbestos fibers escaping into the air; however I know of no tests.that substantiate his claims. We axe presently seeking a replacement for this material. i 2S02.44 f To the best of ray knowledge these insulation materials axe acceptable? however as the test program progresses I will Keep you informed of our recommendations. We are also considering some other materials not mentioned here. Until our evaluation is complete there will be no changes made to the material cards. mcl M. L. Wolperr ; . Materials Engrg. Steam Turbine Division \ 2B002845 o t .t Proposal' for. Eliminating Asbestos Insulation Materials X Process Specification 600359 (Patt 4 only) . Title: Manufacture- and Application of Blanket Insulation . Use: . 'Cylinders, steam chests, valve bodies, valve bonnets, valve flanges, pipe flanges - and frequently used on horizontal joints when block and plastic is hsed on the cylinder, ' Material Status: M41414AD fiber felt insulation - Commercial Name . Manufacturer Asbestos Content ,, , Status '] 48 Turbine Pelt Temp Mat Kaowool Blanket Style 100 Blanket Erco Mat 1300 Forty Eight Pittsburgh Corning Babcock & Wilcox . Eagle Picher ' pastern Refractories None* , . None* unknown ' unknown unknown . continue* to use ; * continue to use : do not use /u_____ . do not use . do not use ' 2, Process Specification 6004,33 (Parts 1 and 2) > ; Title: Application of`Block and Molded Insulation ; . Use: . Pipes. . .' ' ' ' . -. .. * . Material Status: M10130BJ steel wire - do not usey use M 10730DX ... .. stainless steel wire, .065 in. dia. * * . M41511AP asbestos cloth - do not use: use J.* P. Stevens* . fiberglass cloth style 84205 finish 9383. '. 28002846 . M46102BB block insulation - contains asbestos, do' -not usey , use Philip Carey's Careytemp 1500 or Keene's ThermasII * '* . Block insulation. ' im M46110BA cement - contains asbestos, do not use? use . Philip Carey's MW - One or Keene's Super Powerhouse . \ insulating cement. Specifically Btated in manufacturer's literature or letter that there is no asbestos in this ,* insulation. . ' 'I ; i* Q ~) ] J^ | vi * ^ proposal for Ellmlnatlnjg Asbestos Insulation Material (continued, % . M53351DU paste - contains asbestos, continue to use) ' no replacement at present ' M54251AH molded insulation - ~ V..... Commercial 1 ' ** ' : ' ,.' : . , .Name . Manufacturer . . v. * . -- . ' . r. . - . ,. \. ** ,, Careytemp 1500 Epitherm 1200 . ' Thermo 12 . j ; 1 MF Pipe Insulation' Kaylo. 10 AF-V^-p * ! ' Philip Carey1 . Eagle Picher ; 1' 1 ' ' Johns Manville ri'orty Eight 1, * (Jwens Corning ' '- " / Process Specification 600729 (Parts 1 and 2) Title* Application of Block and Plastic Insulation . Asbestos Content None* ,, None* .-.unknown , . 1 unknown - unknown 'i' * . ', ` : .` ' 1 * ' t Status '' ` , continue to usedo .not use* use , Keene's Thermasll do not use do not use do not use * '' tJse* Cylinders, steam chests, valve bidies, valve bonnets, steam chest bonnets, valve flanges, and pipe flanges.; ' j -. ` ' - ' ' . Material Status* M42331AA asbestos paper - do not use* use J. P. Stevens1 . . fiberglass cloth style 84205 finish 9383. - ,t * M46110BJ plastic insulation ' . ' -. . . .. Commercial .Marne , Manufacturer . Asbestos . Content Status MW50 Insulation Cement One Plus Znsul.Cement Super 66 Plastic Insuli 460 Insulation Cement Philip Carey Keene Eagle Picher Johns Manville ! None* * None* Unknown unknown continue to use continue to use do not use do not use Specifically stated in manufacturer's literature or.letter that there is no asbestos in this insulation. . 1 i . . . Page 2 M 2B002B47 o l I is III Proposal for Eliminating Asbest sulation Materials (continued} k W \\ M46601AB block insulation -- ' * * Commercial Name ' Manufacturer TT ** Mono Block Keene | Banroc HT Johns Mdnville IS Supertemp PV 1( . Eagle Picher Asbestos Content None* None* unknown Status continue to use ' continue td use ' do not use . \ 4. Process Specification 600916 (Parti, 1 and 2) * , i ^' || v A . :, .. , ' , . : . | i !'\ - Title* Application of Sprayed Asbestos . * .! : Insulation- - * . ` ' . ; Use* Customer's option in place of PS $00433 for piping and $00729 for . cylinders, steam chests, valves, flanges, and bonnets. ' Material Status* M41511AP asbestos cloth -r^do not use* use J. P. Steve'ns* Jtyfr) 1 *. #fi4bUearwgml1assese coth stylea O84A29#0\$cT ^fiTnn4ish 9383. 1 V. . '. ' . . `' M42331AA asbestos paper - do not use* use J. P. Stevens' fiberglass coth style 84205 finish 9383. ' , M46110BA cement - contains asbestos, do not use* use Philip Carey's MW - One or Keene's Super Powerhouse-^ insulating cement, i ! - " / !i 1: ' ' / M53351DU paste - contains asbestos;, continue to use; * j^no replacement at present. -* , M4251AQ spray insulation ~ non asbestos*,-continue to use \' *Specifically stated in manufacturer's literature or letter that there is no asbestos in this , insulation. ,[ ., * Ii . * 11 ' . 28002848