Document VKoZgjwjRv1mkgMkbdLXb36bZ
* G201
Elements Change Control
W. Link
.
Fnrn : General Order Engrg. '
WIN :
Date : March 22, 1973
Street: PACE 260
.
. S.O. 13A4541
G.O. 3CT98716
'
HP Cylinder insulation
cc: .G201 Elements Change Control - S. Jones A301 Product Manufacturing Engineering - W. McQuire
W102 A302 G201
A305 A201
Erection 6 Test - R. Castaldo
`
Project Drafting - P. Serino
Elements Drafting - A. Budko
.
Product Development. - B. Brown
Product Manufacturing Engineering - R.. Quinn
Ref: ,R. Quinn's letter dated March .20,. 1973. Also reference-
M. L. Wolpert's letter dated Eebruary 26, 1973 (copy
attached). -
' ..
.
Before agreeing 'to Mr. Quinn's suggestion of providing blankets
(which are more expensive) X would suggest an investigation be __
made of the block Insulation that Is used on the.erection floor
to.determine if it contains any asbestos material. Mr. Volpert's .
letter indicates that block and plastic insulation is available
that does not have any asbestos content. If our drawings in^
dlcate that we are using block Insulation that does contain
asbestos I recommend that the drawings be changed to Indicate -
the ones that are acceptable in Mr. Wolpert's letter.
'
ds Attachment
T-
J
*
' *
4
%.$. JijuULLuLKjc^AJ
J. A. Giuliucci, Project Engineer General Order Engrg.-North '
ftwv :S* T. Materials Engrg. ww 1325-4884 tea :February 26, 1973 .Subject: insulation Materials
-O
: o.
in'--
A-404 GOE Projects South
A-403 Frame Engineering
'
A-101 PGS Installation Service
-G-201 HP-IP Elements
-- '
G-201 LP Elements
.:
<3-201 Valves and Hydraulic Controls
.G-201 Service Project Engineering
G-201 Service Analysis Engineering-
N-202 Small Steam Turbine Elements
cc: G-201 Materials Engineering A-203 Standards Engineering A-404 GOE Projects
A-404 GOE Projects" ---------------------
. R&D Center Inorganic'Materials
sSW9WjtcheM
J. D. Dickinson
H. M. Owens
J. H.'Goumas
kS. L. Jones .
J. J. Hart
,
J. W. Ross
R. W. LeGates
G. F. Hyde
...
J. S. Bonk "
> '
-.
M. Schmerling ^
M. Dorfman
R. M. Laub
--JvHr-Stnrges --
K. W. Grossett
Steam Turbine Division Materials Engineering has been requested
Jfco__approve non-asbe.stos turbine insulation materials as replace-
ments for materials that contain asbestos "In order to bypass th
elaborate precautions required by OSHA. 1 have'initiated a ten'
program and I will be evaluating the new insulation materials that
we are proposing.
.
. ` .-- -
-
.
The proposal for Eliminating Asbestos Insulation Materials is
attached. In some cases,for a particular materialspecification'
there is a breakdown by manufacturer where some suppliers' insul
ation contains asbestos and others do not. In other cases where
all suppliers' insulation material contains asbestos (e.g. asbestos
cloth) the material specification gets a direct substitute. There
are two specific materials that should be discussed further.
M10130BJ wire is being replaced by M10730DX wire because it has
been objected to by some customers. We can not propose a replace
ment for M53351DU paste at this time. This is the only asbestos
.material that has ."continue to use" status. The manufacturer claims
there .is no possibility of asbestos fibers escaping into the air;
however I know of no tests.that substantiate his claims. We axe
presently seeking a replacement for this material.
i 2S02.44
f
To the best of ray knowledge these insulation materials axe acceptable? however as the test program progresses I will Keep you informed of our recommendations. We are also considering some other materials not mentioned here. Until our evaluation is complete there will be no changes made to the material cards.
mcl
M. L. Wolperr
;
. Materials Engrg.
Steam Turbine Division
\
2B002845
o
t .t Proposal' for. Eliminating Asbestos Insulation Materials
X Process Specification 600359 (Patt 4 only)
.
Title: Manufacture- and Application of Blanket Insulation .
Use: . 'Cylinders, steam chests, valve bodies, valve bonnets, valve flanges, pipe flanges
- and frequently used on horizontal joints when block and plastic is hsed on the
cylinder,
'
Material Status: M41414AD fiber felt insulation -
Commercial Name
.
Manufacturer
Asbestos Content ,,
,
Status
']
48 Turbine Pelt Temp Mat Kaowool Blanket Style 100 Blanket Erco Mat 1300
Forty Eight
Pittsburgh Corning
Babcock & Wilcox
.
Eagle Picher
'
pastern Refractories
None* , . None* unknown ' unknown unknown
.
continue* to use ; * continue to use
: do not use /u_____ . do not use .
do not use '
2, Process Specification 6004,33 (Parts 1 and 2)
>
; Title: Application of`Block and Molded Insulation
;
. Use: . Pipes.
. .'
'
'
' . -.
.. * .
Material Status: M10130BJ steel wire - do not usey use M 10730DX ... ..
stainless steel wire, .065 in. dia.
*
*
. M41511AP asbestos cloth - do not use: use J.* P. Stevens*
.
fiberglass cloth style 84205 finish 9383.
'.
28002846
. M46102BB block insulation - contains asbestos, do' -not usey , use Philip Carey's Careytemp 1500 or Keene's ThermasII * '* .
Block insulation.
'
im
M46110BA cement - contains asbestos, do not use? use .
Philip Carey's MW - One or Keene's Super Powerhouse .
\
insulating cement.
Specifically Btated in manufacturer's literature or letter that there is no asbestos in this
,* insulation.
.
'
'I
; i*
Q
~)
] J^ |
vi
*
^
proposal for Ellmlnatlnjg Asbestos Insulation Material (continued,
% .
M53351DU paste - contains asbestos, continue to use)
' no replacement at present
'
M54251AH molded insulation -
~ V..... Commercial
1
'
** ' : ' ,.' : . , .Name
. Manufacturer .
.
v. * .
-- . '
.
r. . - . ,.
\. **
,,
Careytemp 1500 Epitherm 1200
.
' Thermo 12 . j
; 1
MF Pipe Insulation'
Kaylo. 10 AF-V^-p * !
'
Philip Carey1 .
Eagle Picher ;
1'
1 '
' Johns Manville ri'orty Eight 1, *
(Jwens Corning
' '-
" /
Process Specification 600729 (Parts 1 and 2) Title* Application of Block and Plastic Insulation
.
Asbestos Content
None* ,, None*
.-.unknown , . 1 unknown -
unknown
'i' * .
', `
: .`
' 1 * ' t Status '' `
,
continue to usedo .not use* use , Keene's Thermasll do not use do not use do not use *
''
tJse* Cylinders, steam chests, valve bidies, valve bonnets, steam chest bonnets, valve flanges,
and pipe flanges.;
'
j -.
`
'
- '
'
.
Material Status* M42331AA asbestos paper - do not use* use J. P. Stevens1
. . fiberglass cloth style 84205 finish 9383.
- ,t
*
M46110BJ plastic insulation '
. ' -.
.
. ..
Commercial .Marne ,
Manufacturer
. Asbestos . Content
Status
MW50 Insulation Cement One Plus Znsul.Cement Super 66 Plastic Insuli 460 Insulation Cement
Philip Carey Keene Eagle Picher Johns Manville
!
None* *
None* Unknown unknown
continue to use continue to use do not use do not use
Specifically stated in manufacturer's literature or.letter that there is no
asbestos in this insulation.
.
1 i . . .
Page 2 M
2B002B47
o
l I
is III
Proposal for Eliminating Asbest
sulation Materials (continued}
k W
\\
M46601AB block insulation --
' * *
Commercial
Name
' Manufacturer
TT
** Mono Block
Keene |
Banroc HT
Johns Mdnville
IS Supertemp PV
1( . Eagle Picher
Asbestos Content
None* None* unknown
Status
continue to use
' continue td use
' do not use
.
\
4. Process Specification 600916 (Parti, 1 and 2) *
,
i ^'
||
v A
. :, ..
, '
, .
:
.
| i !'\ -
Title* Application of Sprayed Asbestos
.
*
.!
:
Insulation-
- * .
` ' . ;
Use* Customer's option in place of PS $00433 for piping and $00729 for
.
cylinders, steam chests, valves, flanges, and bonnets.
'
Material Status* M41511AP asbestos cloth -r^do not use* use J. P. Steve'ns* Jtyfr) 1
*.
#fi4bUearwgml1assese coth stylea O84A29#0\$cT ^fiTnn4ish 9383.
1 V.
. '.
' . . `'
M42331AA asbestos paper - do not use* use J. P. Stevens'
fiberglass coth style 84205 finish 9383.
'
,
M46110BA cement - contains asbestos, do not use* use
Philip Carey's MW - One or Keene's Super Powerhouse-^
insulating cement, i !
-
"
/ !i 1:
' '
/ M53351DU paste - contains asbestos;, continue to use; *
j^no replacement at present.
-*
,
M4251AQ spray insulation ~ non asbestos*,-continue to use \'
*Specifically stated in manufacturer's literature or letter that there is no asbestos in this
, insulation.
,[
.,
*
Ii .
*
11
' .
28002848