Document VJy1qZ43DXGdbjjgyXRNgXdGj
Hoffman Specially Co., Inc.
Specialties, Healing
Hoffman Differential Loop
The Differential Loop is the safety device for maintaining a steady water line in vapor and vapor vacuum systems. It is entirely automatic, non-adjustable and has no moving parts to stick at a critical moment.
In operation the water rises in the return main only to a certain pre-,
determined height. The loop then functions, blowing over a small quantity
of steam, which closes the No. 10 or 11 Valve used for venting the system
and then compresses the air which is "bottled up" in the return main and
builds up a pressure which prevents further rise of water in the vertical
part of the return beyond the predetermined amount. As soon as this is
accomplished, and the action is almost instantaneous,, the loop reseals and
no more steam is blown over until the differential pressure is lost. It will
be readily seen that, by the alternate blowing over and resealing of the
Hoffman Differ- loop, a constant differential pressure will be 'maintained between the
entuU Loop
,
steam main and return main. Also by the main
Hoffman Differential Loop.
tenance of this differential no matter how high the
boiler pressure goes, circulation will start in a
radiator as soon as the inlet valve is opened even
though the return main vent is closed through
loop action.
Standard Differential Loops are made in four sizes, to handle systems up to 15,000 sq. ft. of radiation. For larger systems the No. 4 Loops can be installed in a battery.
No. 1 and No. 2^Loops should not be used where the low point in the dry return is less than 24 in. above boiler water line; with the No. 3 and No. 4* Loops this distance must be at least 30 in.
DIMENSIONS AND CAPACITIES OF HOFFMAN DIFFERENTIAL LOOPS
Loop No.
A
B
c
D
E
F
Capacity C j K L Sq. Ft.
Rad.
1 y.'
iy.' iy,*
w IS/.'
26' 30H' 7H' . 3'
2000
2
y.' iy.' iy.* ivi"
>/.' IS/.'
26'
7M' 3'
3500
3 y.' w 1 w 2'
r 25'
32' 37'/.' nr
3y,'
7500 .
4 y.' r . 1" 2?
r 25'
32' 3P/.' nr
S/2'
15.000
Write for Descriptive Circular--Hoffman Controlled Heat . 600
Hoffman Specially Co., Inc.
Specialties, Heating
TYPICAL INSTALLATIONS HOFFMAN "CONTROLLED HEAT" EQUIPMENT
SUPPLY MAIN
SUPPLY TO LOOP
OPYRSTUJTN MAM
GRAOUIG OOWN FROM MBLR
ALLOWANCE . GRADE OF MAM
/HOFFMAN
>' Mil--7
OOTCRENTUL LOOP .
SIZES 6c CAPACITIES
LOOP CAMCtTT AmCNffTfo FlPMC Silt soriuo. i tnm lcor*CT0ff
N9| eooo 24" j ijfc*
M*t 3500 N*3 7500 Nt4 15000
24 l'/4 so iy% SO 1 2
Blow off valve1
Write for Descriptive Circular--Hoffman Controlled Heal 601