HEATING VENTILAT1NC AIR CONDITIONING CUIDE 1943 A53 and A120 combines the schedule thicknesses of the American Standard for Wrought-iron and Wrought-Steel Pipe, A.5.A. B36.10, and the old series designations. Standard-weight pipe is generally furnished with threaded ends in random lengths of 16 to 22 ft, although when ordered with plain ends, 5 per cent may be in lengths of 12 to 16 ft. Five per cent of the total number of lengths ordered may be jointers which are two pieces coupled together. Extra-strong pipe is generally furnished with plain ends in Table 2. Dimensions of Schedules 60 and 80 and Extra-Strong Pipe3 External Internal External Internal External Internal i!j _ _ Metal External Surface Internal Surface 1 Diameter, In. Sesb Weight per Ft Plain B Ends, Lb .g" 1a i Circum ference, In. Transverse Area, ; Sq In. Length of Pipe, Ft per Sq Ft Length op Pipe, Ft Con Weight op Water, Lb taining ICuFt per Ft K 0.405 X. 0.540 X 0.675 a 0.840 X 1.050 1 1.315 IX 1.660 IH 1.900 0315 0302 0.423 0346 0.095 0.119 0,126 0.147 0314 0335 0.738 1.087 0.742 0.957 1.278 1300 0.154 0.179 0.191 0.200 1.473 2.171 2.996 3.631 1372 1.696 2.121 2.639 3.299 4.131 5315 5.969 0.675 0.949 1329 1.715 2.331 3.007 4.015 4.712 0.129 0.229 0358 0354 0.036 0.072 0.141 0334 0.&M . 0.433 1358 0.719 2.164 1.283 2.835 1.767 0.093 0.157 0317 0320 0.433 0.639 0.881 1.068 2 2375 2K 2375 3 3300 3M 4.000 4 4300 1.939 2323 2.900 3.364 3.826 0.218 0.276 0300 0318 0.337 5.022 7.661 10.252 12.505 14.983 7.461 9.032 10.996 12366 14.137 6.092 7398 9.111 10368 12.020 4.430 6.492 9.621 12366 15.904 2.953 4.238 6.605 8388 11.497 1.477 2354 3.016 3.678 4.407 5 5363. 4313 0.375 20.778 17.477 15.120 24306 18.194 6.112 6 6.625 5.761 0.432 28373 20313 18.099 34.472 26.067 8.405 8 8.625 7.625 0.500 43388 27.096 23.955 58.42? 45.663 12.763 10C 10.750 9.750 0300 54.735 33.772 30.631 90.763 74.662 16.101 12 12.750 11.750 0300 65.415 40.055 36.914 127.676 108.434 19.242 9.431 7.073 5.658 4.547 17.766 396639 12.648 2010390 9.030 1024.689 6.995 615.017 0.016 0.031 0.061 0.102 3.637 2.904 2301 2.010 5.147 3.991 2.988 2346 333.016 200.193 112356 81.487 0.188 0312 036 0.77 1.608 1328 1.091 0.954 0348 1.969 1.644 1317 1.135 0.998 48.766 33.976 21301 16.202 12325 138 137 236 334 4.98 0.686 0376 0.443 0355 0399 0.793 0.663 0300 0.391 0325 7.915 7.8&. 5324 1139 3.154 19.78 1.929 32.35 1328 46.92 aExtra-strong wrought-iron pipe has approximately the same wall thicknesses and weights as contained herein for steel pipe. For exact dimensions, see American Standard for Wrought-iron. and Wrought-Steel Pipe, AJ>~A. B36.10. bThicknesses shown in bold face type are identical with thicknesses for Schedule 80 pipe for A.S.A B36.10. c$ame as Schedule 60, A.S.A. B36.10. random lengths of 12 to 22 ft, although 5 per cent may be in lengths of 6 to 12 ft. In addition to IPS copper pipe, several varieties of copper tubing are in use with either flared or compression couplings or soldered joints. Dimen sions of copper water tubing intended for plumbing, underground water service, fuel-oil lines, gas lines, etc,, have been standardized by the U. S. Government and the American Society for Testing Materials, There are three standard wall-thickness schedules of copper water tubing classified in accordance with their principal uses as follows: Type K--Designed for underground services and general plumbing service. Type L--Designed for general plumbing purposes. Type M--Designed for use with soldered fittings only. 348 CHAPTER 18. PIPE, FITTINGS, WELDING In general, Type K is used where corrosion conditions are severe, and Types L and M where such conditions may be considered normal as, for instance, in heating work. Types K and L are available in both hard and soft tempers; Type M is available only in hard temper. Where flexibility is essential as in hidden replacement work or where as few joints as possible are desired as in fuel-oil lines, the soft temper is commonly used. New or exposed work generally employs copper pipe of a hard temper. All three classes are extensively used with soldered fittings. Table 3. Standard Weights and Dimensions of Welded and Seamless Steel Pipe3 Standard-Weight Pipe Extra-Strong Pipe Double ExtraStrong PlPEb Schedule 30 Outside No. OF Size Diame Threads ter, In. per In. Wall Wright Thick per Ft, ness, Lb In. T&C Schedule 40 Wall Thick ness, In. Weight per Ft, Lb T&C Schedule 60 Wall Thick ness, In. Weight per Ft, Lb Plain Fnris Schedilie 80 Wall Thick ness, In. Weight perFt, Lb Plain Ends Wall Thick ness, In. Weight Per Ft, Lb Plain Ends M 0.405 X 0.540 0.675 8- 0340 27 18 18 14 -....... X 1.050 1315 IX 1.660 2IX 1.900 2375 2X 2375 3 .3300 3X 4.000 4 4300 14 11H 11K 11H 11K 8 8 8 8 ......... 0.068 0.088 0.091 0.109 0.113 0.133 0.140 0.145 0.154 0.203 0316 0.226 0337 035 0.43 037 035 1.13 1.68 238 2.73 3.68 532 7.62 9.20 1039 0395 0.119 0.126 0.147. 0.154 0.179 0.191 0.200 0318 0.276 0300 0318 0337 031 034 0.74 1.09 1.47 2.17 3.00 3.63 5.02 7.66 10.25 1231 14.98 0394 0308 0358 0.382 0.400 0.436 0352 0.600 0.636 0.674 1.71 2.44 3.66 531 6.41 9.03 . 13.70 1838 2235 2734 5 5363 6 6.625 8 8.625 10C 10.750 T2d 12.750 8 8 8 8 8 0377 .25.00 0307 35.00 0330 43.00 0.258 0.280 0322 0.365 0375 1431 19.19 2831 41.13 50.71 0.500 54.74 03006 65.41 0375 0.432 0.500 20.78 28.57 43.39 0.750 0364 0375 3835 53.16 72.42 From Standard Specifications for Welded and Seamless Steel Pipe of the American Society for Testing Materials, A*S.T.M. Designation A120. aSizes larger than those shown in the table are measured by their outside diameter, such as 14 in. out* side diameter, etc. ' These larger sizes will be furnished with plain ends, unless otherwise specified. The weights will correspond to the manufacturers' published standards although it is possible to calculate the theoretical weights for any given size and wall thickness on the basis of 1 cu in. of steel weighing 0.2833 lb. bThe American Standard for Wrought-iron and Wrought-Steel Pipe A.S.A. B36.10-1939 has assigned no schedule number to Double Extra-Strong pipe. cA 10 in. Standard Weight pipe is also available with 0.279 in. wall thickness, but this wall is not covered by a Schedule Number. # dOwing to a departure from the Standard-Weight and Extra-Strong wall thicknesses for the 12 in. nominal size, Schedules 40 and 60, Table 2 of the A.S.A. B36.10-1939, Standard for Wrought-iron and WroughtSteel Pipe, the regular Standard and Extra-Strong wall thicknesses (0.375 in. and 0.500 in.) have been substituted. Standard dimensions, weights, and diameter and wall-thickness : tolerances for these classes of copper tubing are given in Table 4. Copper pipe is also available with dimensions of steel pipe. Refrigeration lines used in connection with air conditioning equipment also employ copper tubing extensively. For refrigeration use where tubing absolutely free from scale and dirt is required, bright annealed copper tubing that has been deoxidized is used. This tubing is available in a variety of sizes and wall thicknesses. . . 349