Document VJgqJ7vL4Zr9eRLG4Rn0NM3dg
TENNECOTER-orricn memo CHEMICALS, INC.
P. Scheiner to E. Schwartz
From J. P. Sandstedt
.Stack Sampling Facilities
At Burlington at Piscataway
D*tl September 26, 1977 Copt to E. V. Schenke
Attached is the Texas Air Control Board's guideline for stack sampling facilities, as I promised. This guideline was prepared for Texas stack sampling programs, and responds to EPA and State requirements.
You may want to follow these rules locations at Burlington and Flemington.
in providing emission sampling
JPS:db
COLORXTE 019125
CHAPTER 2 -.STACK SAMPLING FACILITIES
Introduction The following is a statement of Rule 10 of the General Rules, Texas Air Control Board:
* Rule 10 Sampling Ports
Any person, at the request of the Board shall provide in connection with each flue a power source near the point of testing in addition to such sampling and testing facilities and sampling ports, including safe and easy access thereto, exclusive of instruments and sensing devices, as may be necessary for the Board tc determine the nature and quality of emissions which are or may be discharged as a result of source operations. Evidence and data based on :.-these-"samples'*'and "calculations- may be`used -'to--' ''substantiate * violations of the 'Act,* Rules'And" Regulations. Agents of the Board shall be permitted to sample the stacks during operating hours.
New construction or modification regulated by the permits system (Regulation VI) may also require the consideration of stack sampling facilities as specified in Rule 603.14:
Rule 603.14 The proposed facility will have provisions for measuring the emission of significant air contaminants as determined by the Executive Director.
2-1 COLORXTE 019126
In accordance with the provisions of Rule 10 and Rule
603.14, the Source Sampling Section has established guidelines
for stack sampling facilities. It should be noted that
these guidelines, cannot anticipate all situations, and
special cases will often occur, . Each source should there-
<'"ra"United on an individual basis; and source operators
Section for
k
sampling
.
NOTE: Existing sources equipped with stack sampling
facilities approved previously by the Source
Sampling Section will not in all probability be
required to meet the new specifications herein, .
with the exception of the additional power require
ment for a 208/220-volt, 30-amp outlet at the stack
base as described in this section under Power Supply,
pg. 2-5. This outlet must be provided in conjunction
. with all existing stack sampling facilities due to
the increased power requirements of new Texas Air
. control 'Board 'monitoring ' systems'. - * -o-Vv
,v
The following guidelines constitute minimum requirements for safe and accessible stack sampling facilities:
Sampling Ports
Port Location
Ports should be located at least eight stack diameters
downstream of any bends, inlets, constrictions, abatement
equipment, or other flow disturbances; and at least two
stack diameters upstream of the stack exit or other flow
disturbances.' Stacks which cannot meet these criteria may
require a stack extension unless the source operator can
demonstrate that this remedy is not feasible, in which case
an alternate port location must be approved by the Source
Sampling Section.
.
2-2 COLORITE 019127
Port Type
Port?, snail bp;a 3-inch'I.p. standard industrial flanged pipe with 6-inch bolt circle diameter. An easily removable blind flange shall be provided to, close the port when not in use.
Port sizes larger than 3 inches I.D. are permissible and even desirable on large diameter, double-walled, stacks which necessitate longer ports. These ports should also be equipped with a standard industrial flange the same I.D. as the port. Persons intending to install ports larger than * 3 inches I.D. should notify the Source Sampling Section.
NOTE: '
Gate valves should be installed only when extreme stack conditions or the presence of hazardous materials require such devices for safety considerations.
Port Installation
.'Ports" shall "be 'installed ''flush rwith - the'-'interior 'stack
wall. `
''
-
Ports shall extend outward from the exterior stack wall no less than 3 inches nor more than 8 inches, unless addi tional length is required for gate valve installation (See NOTE above) .
Ports shall be installed no less than 5 feet nor more than 6 feet above the floor of the platform.
Ports shall be installed with respect to the limitations of the clearance zone mentioned later in this chapter.
2-3
t
*/ COLORITE 019128
Number of Ports Required
If the sum of the stack inside diameter plus one port length (stack inside wall to end of port extension) is less than 10 feet, 2 ports shall be installed on diameters 90 apart.
NOTE:
Proposed EPA guidelines for continuous monitoring of certain categories of sources may necessitate the, installation of 4 ports on diameters 90 apart for stacks in this size range in order that' the TACB may thoroughly evaluate monitor performance at regular intervals.
"If the sum of the stack inside diameter plus one port length (stack inside wall to end of port extension) is equal to or greater than 10 feet, 4 ports shall be installed on diameters 90 apart.
Port Loading
The port installations shall be capable of supporting the
following loads:
- * " Ve'r tic a 1' 'shear 'Jo f' 20 O' pounds'. -
Horizontal'shear'of 50'pounds . ' 'v '***''''
'
Radial tension of 50 pounds (along stack diameter).
Work Platform
Size and Extent of Platform
If 2 ports are required at 90, the work platform shall serve that quarter of the stack circumference between the ports and extending at least 3 feet beyond each port. Minimum platform width shall be 3 feet.
If 4 ports are required at 90, the work platform shall serve the entire circumference of the stack. Minimum plat form width shall be .4 feet unless the sum of the stack Inside diameter plus one port length (stack inside wall to e end of port extension) is less than 10 feet, in which case
i
*"2-4
COLORITE~019129'
the minimum platform width is 3 feet.
Plaffcrr: Access'
Safe and easy access to the work platform shall be provided via ladder, stairway/ or other suitable means.
''Guardrails, Ladder Wells, and Stairwells
,t ,
*
' A safe guardrail shall be provided cn the platform'. Angular
rather than round rail members shall be used if possible.
No ladder well, stairwell, or other such opening shall be located within 3 feet of any port.
Ladder wells shall be covered at the platform and any stairwell leading directly to the platform shall be equipped with a safety bar or the equivalent at the opening.
Platform Loading
The work platform shall be able to support at least 3 men
and 200 pounds of'test equipment (at'least'800 pburids totai)
v. / /!
Clearance Zone
A three-dimensional obstruction-free clearance zone shall be
provided around each port. The zone shall extend 1 foot
\
above the port, 2 feet below the port, and 2 feet to either
side of the port. The zone shall extend outward from the
exterior wall of the stack to a distance of at least one
stack inside diameter plus one port length (inside wall to
end of port extension) plus 3 feet. The clearance zone is
illustrated in Figure 2-1.-
'
Power Supply Power sources shall be provided as follows:
(
2-5
COLORITE 019130
PORT DIMENSION REQUIREKENTS
(Outside) 8" Max Unless Gate Valve Installed
__ 3"I.D. (min)Industrial FlanCapped When not in Use
'--Install Gate Valve if Stack Contains Dangerous Gases or Gases Over 200F Under Positive Pressure
STRENGTH REQUIREMENTS
I ^50 lbs. Side Load ^50 lbs. Radial Tension Load
At Least Two Stack Diameters Below Stack Exit
i- ^
"Eight to Ten'Stack ' ; Diameters Above Last Obstruction
Work Area Clearance
WORK PLATFORM
A. At Least 3' Wide (4* Wide for Stacks with 10 A or Greater I.D.} and
Capable of Supporting 3 People and 200 lbs. of Test Equipment
B. Safe Guardrail on Platform with Access by Safe Ladder or Other Suitable Means, i: Ladder is Used, Ladder Well1* Must be Loacted at Least
, 3' from Ports
.1..
C. Wo Obstructions to be
Within 3' Horizontal
Figure 2-1
Hadms on Platform Beneath
Stack Facilities
Ports
Revised
. * **
, *'*# - * * 3/31/76'
...2-6
200 lbs Vertical Shear Load
. ^-At least one Stack Diametc:
. -vPlus v3 '` From Stack-'
,;:Circumf erence
"a
' * ,, 48,"-"
r''
Clearance 36" Zjsne I
t
- POWER SOURCES
A. 115V, 15A, Single Phase, 60 Hz AC
.Located on Platform and at Base of Stack with Grounded -Weatherproof Outlet
B, 220V, 30A, Single Phase, 60 Hz AC
This female receptacle must
be "Hubbell" 73 7i> at .
equivalent, located at base
of stack only.
1
COLORITE 019131
Platform
One 115-v.olt, 15-amp, single phase, 60 hertz alternating current circuit .with a grounded two-receptacle weather proof outlet. Receptacles shall accept standard threeprong grounded household-type plugs or suitable adapters shall be provided.
Stack Base
t*
,*
One JJ 5-volt, 30-amp, 'single phase, 60 hertz alternating
current circuit with a grounded two-receptacle weather
proof outlet. Receptacles shall accept standard three-
-prong grounded household-type plugs or suitable adapters
shall be provided.
One 208/220-volt, 30-amp, alternating current circuit with a grounded weatherproof outlet. This female receptacle must be a "Hubbell 7379" or equivalent in order to mate with Air Control Board power cords which use male Hubbell plugs.
' Vehicle Access-- and-:Parking "- v!
Kxcept for situations in which sampling operations must be conducted from a rooftop or similar structure, stack sampling will be coordinated and controlledfrom a cargo van or trailer which will be parked near the base of the stack for the duration of the sampling. Vehicle access and'parking space must be provided since various umbilical, communications, and equipment transport lines will be strung from the van or trailer to the stack platform and will remain in position during the operations.
Compliance with Safety Standards
Stack sampling facilities must meet all applicable OSHA
requirements and conform to any other relevant safety
guidelines.
'
(
Revised 3/31/76.
4
'
I COLORITE 019132
* Optional Permanent Monorail System
Some source operators may wish to install a permanent
monorail system to meet TACB requirements and to facilitate
self-monitoriny-as required under Rule .9, especially where
the stack in question is greater than 10 feet in diameter.
Persons considering such installations should contact the
Source Sampling Section for complete details and specifica
tions.
*,
/ , .
0 **
,
V
*'
*
Miscellaneous Requirements
In addition to the specific requirements described in this
section, other requirements may be requested for sources
with very large stacks or non-standard sampling locations.
Examples of such requirements are:
1. Power hoists for sampling platforms in excess of
200 feet above ground level.
2. Additional attachment points above and to each
side of the ports for supporting very long monorails.
3. Provisions for sampling vertically in horizontal
ducts
'-
s_. stated -in-the: introduction- to--this> section--source -V"; operators are requested to contact the Source Sampling I . Section for assistance before initiating the construction ; of stack sampling facilities.
Excess Air
>
In addition to the above requirements, certain processes, e.g. sulfur recovery units, may require provisions for determining the composition and flow rates of feed stock streams. This information, taken at the time of sampling, is necessary to determine the amount of excess >air in the stack effluent.
2-8
* * **
'
/
COLORITE 019133