CHAPTER 57
1962 Guide And Date Book
(tetom tanks nay be ocm'ffed by venting through system gravity tank.
fig. 9 .... Two-Temperature Brine System*
by two circulating loops from which, by setting valves at the refrigerators, one can selectively utilise the desired brine.
Brine returns from each cooling unit should run individually to the central plant return-valve twin manifold where room temperatures may be remotely controlled by brine flow. By controlling return flow the systems are under pumping pres sure to the return valve and air binding will be at a minimiun.
The returning brine is diverted to its respective collector tank from which the brine pump takes its suction. Two types of systems are in use, one in which the return brine streams are in view of the operator, providing the so-called open system, and the closed system in which a static head is main tained on the enclosed return tank and system by a vented overhead gravity tank. These camp, brine systems may be used with plants using a refrigerant other than Refrigerant 12.
A simple two-temperature brine system can also be by providing a closed high temperature brine loop or cooling unit with a recirculating pump, the selective brine tempera ture being maintained by a thermostatically operated pilot valve which will feed low temperature brine to the loop or cooler as required. The central plant thus becomes essentially a one-temperature installation.
With the use of brine for distribution there results an additional temperature differential between the primary evaporating refrigerant and the compartment air tempera ture. With a room temperature of --10 F and Refrigerant 12, compounded effect is desirable by the cagraHing of the re frigerant plant. In this operation the high temperature brine is circulated through the condenser in lieu of sea water, thus reducing head pressure and compression ratios over h*.fc of single-stage compression.
To facilitate staging by this method a n.wtHing brine pump is suggested which will recirculate its own allotment of brine at a predetermined temperature thermostatically maintained by a pilot feed valve which will control the addi tion of low temperature brine.
For defrosting with hot brine an independent gnuJl pipe loop is suggested, it having its own pump and heater. In this operation the cold brine valves are closed at the refrigerator, and the cooling coils are placed in series with the pump and heater. By this system the brine content of the coil only is displaced which foregoes the heating of an entire pipe line. Should the volume of the whole circuit be returned to the circulating system, it would, for an interval, affect the equilib rium of the entire plant.
Thermometers. The principal indicator of the functioning of a refrigerator plaht is the thermometer. Those instruments associated with the central machinery plant reflect thermal efficiencies of the plant, and their purposes and location are well defined. They need no further description here.
The end results of the applied refrigeration, namely space temperature levels and control, are indicated by the room thermometers. The definition of room temperature is fixed to the location of the instrument's sensitive bulb within that space. Refrigeration is affected only by the temperature rise of the refrigerating air stream and it must follow that all parts of the room enclosure are not the same temperature reading.
In rooms operating with considerable margin below or above the freezing temperature of the product, the bulb can be located with considerable tolerance, but in rooms operating in a close range above the commodity's freezing temperature, care must be exercised that damage may not be done in cold zones while the thermometer is indicating a safe reading. In most ships the spaces are convertible to any tem perature and the positioning of the bulb is critical. There will be cases when the operator should know this and apply refrigeration accordingly. The bulb should be so installed that there will no false readings due to being in direct contact with warmside surfaces or refrigerating equipment. Rooms fitted with cold air units should have tire bulbs located in the supply air stream, that being the point of critical tempera tures for chill cargo. When 32 to 33 F supply air is distributed the heat of the load is being removed as rapidly as possible with safety. Return air temperatures must volunteer.
Indicating thermometers inserted - in walls through the insulation are not satisfactorily accurate or representative. Indicating dial thermometers should serve each room with the dial installed externally and near the access doors. All bulbs used for comparative readings should be installed ad jacent each to the other. Switch-operated, electric resistance indicating thermometers should be instellar! with the dial located at the log desk.
Recording thermometers are asaantial to proper operation
and management of cargo refrigerators. Mercury actuated instruments will, due to system limitations, have the in strument near the refrigerator. Electric resistance recording instruments are best located in the machinery room where they are under constant observation.
LOAD DETERMINATION
Specifications
The specifications should set forth the extreme operating conditions of loading, ambient and sea temperatures, and rates of pull-down.
In the all-purpose installation each compartment should be designed for the refrigeration of warm fresh products from the field or orchard, and for the over-all condition, a per centage division of chill and freezer cargo with simultaneous and total loading should be stated.
Typical conditions include the following:
1. Arrangement and net cubic capacities of the refrigerated
compartments.
2. Thicknesses and kinds of insulation.
3. Ambient temperatures
Weather Surfaces Adjacent Machinery Spaces
10 100F
Other Adjacent Spaces
85F
Sea Temperatures
85F
4. Overall stowage factor cu ft per short ton
70
Marine and Air Transport
607
c Percentage total loading as chill percentage total loading as freezer
6. Receiving temperature, chill cargo Receiving temperature, frozen cargo
7 Carrying temperature, chill cargo
* Carrying temperature, frozen cargo g. Initial period of cargo heat removal g Replacement air at 85 db, 75 wb
75%
25% 80 F 25F 35 F
-10 F
72 hr
The owner should describe the kind of refrigeration system to be installed and specify the number of compressors and other auxiliary parts or apparatus, together with sources of
gmergency pumping and water facilities. All equipment and installations must be specified as corn-
dying with the rules and regulations of the Classification Societies (American Bureau of Skipping, Lloyd's Register, etc.), the U. S. Coast Guard, the U.S. Public Health Service and the ASHRAE Standard 26-56 (also ASA B59.1-1958), Recommended Practice for Mechanical Refrigeration Installo-
tions on Shipboard. Unless the specification writer wishes to assume lull re
sponsibility for the functioning of the plant and all its parts, he must avoid specifying machinery characteristics other than limits of types, speeds, velocities, etc. He should, however, obtain from the vendors fullest details, description and capacities of the equipment they propose to furnish, in order
to permit comparative analysis of the several proposals. Completion tests should be required to determine work
manship and functional performance. Guarantees of perform ance should be extended to cover operations under loaded
service conditions.
Calculations
The following method of calculation of refrigeration loads
for a general service plant carrying heterogeneous chill cargo
is baric and may appear simplified, but is justified by the great
range of conditions common to marine installations. The
many associated variable factors and arbitrary bases do not
justify minutia in formulae for this type of plant. Refrigera
tion loads for freezer cargo may be calculated in similar man
ner the same stowage factor, a specific heat of 0.40 and
an equivalent pulldown period of 72 hr. The loads for respira
tion heat, replacement air, or latent heat of fusion will not be
present. Specialized service in known ambients will yield to meticu
lous calculations, but to the results one should still add ar
bitrary margins of safety. When general calculations axe made, the following operating
variables and arbitrary bases must be first established: .
1. Ambient Air Temperature--ranges from 32 to 100 F. 2. Ambient Sea Temperature--ranges from 32 to 85 F. 3. Conductivity of Insulation--for materials subject to moisture gain their conductivity may increase as much as 3 percent for each 1 percent moisture gain. Age is thus an indirect factor. (See Chapters 22 and 23 of the 1961 Gums And Data Book.) 4. Resistivity of Outer Boundaries, Inner Linings and Surface Pihns--^these factors should be ignored as boundaries and linings axe usually dense and have high conductivity coefficients. 5. Infiltration and Open Door Leakage--for cargo refrigeration installations such losses at sea are negligible. Port exposures during loading or discharge re-establish pulldown conditions 6. Ventilation or Replacement Air--this factor is often missing when carrying heterogeneous cargo or for short-to-medium length voyage periods. For specialized service it may be as much as 5 percent of the gross room volume per minute. 7. Electric Energy Conversion--the energy load from variable output fans and brine pumps will be on demand load rather than connected load. (An arbitrary value of 3000 Btu per hp may be used.) 8. Product Load--th is a factor of widest range for heterogene
ous cargo service. Its density will vary from 40-120 cu ft per short ton and its specific heat will vary from 0.22-0.95. Con tainer loads cannot practically be distinguished from product load and it is recommended that the gross weight of the package
and the specific heat of the product be used. 9. Receiving Temperature of Chill Cargo--ranges from ambient
to carrying temperature. Receiving Temperature of Frozen Cargo-- ranges from 0 to 28 F (when not conforming to code require
ments). 10. Carrying Temperature of Chill Cargo--ranges from 33 to
55 F. Carrying Temperature of Frozen Cargo--ranges from --10 to 0 F. Product temperatures should be assumed to be 5 deg above
environment temperatures. 11. Respiratory HeatofChiU Cargo--at60 F rangesfrom4000 to
46,000 Btu per day, per short ton; at 32 F, ranges from 450 to 82000 Btu per day per short ton. (An arbitrary value of 1000 Btu
per ton per 24 hr may be used.)
CONTAINER VANS
The overall width and length of container vans are limited
by highway regulations. The height and length are limited by
the structural arrangement of the carrying vessel. The loaded
weight is a factor of limitation by highway regulation and the .
lifting capacity of the cargo handling gear. Peculiarities of a
specific trade will influence all of these factors. Despite the
desirability of universal standardization of dimension, weight,
and fittings, each company has developed its own pro
prietary standards. There has been little coordination be
tween the railroads and the shipping industry.
The generally accepted width is 8 ft and the usual height
of commercial containers has been between 8 and 8V ft. The
logistic container widely used by MSTS has dimensions of
6 ft-3 in., 6
in., 8 ft-6 in., for width, height, and length
respectively, and is transported on land by flat-bed trucks
and railway flat cars, in a transverse loading position. The
various standards of length for commercial vans have been
17, 20, 24, 32, and 35 ft. The gross weights range from 5 tons
for the logistic supply container to as much as 30 tons for
the commercial vans. The refrigerated and insulated con
tainers have the same range of dimensions and gross weights
as that of the dry cargo containers.
The scantlings of the containers have been generally ac-
cepted as those which will permit loaded stacking 6-high
in the cellular constructed container ship (Fig. 11). The
corner posts and bottom longitudinals are generally of high
tensile steel and the floor cartings, panel stiffeners and roof
bows are commonly of extruded aluminum shapes. The
boundary panels are of steel, stainless steel or special alloy
aluminum sheet. Some designs use corrugated wall panels in
lieu of shape stiffeners.
To attain highest allowable pay-loads on the highway, the
structural elements have been cut to minimums. The insula
tion of the vans baa likewise been reduced to minimums to
gain maximum internal volumes at the expense of the useful
capacity and power input of the refrigerating machinery.
The method of handling containers varies with each com-,
pany. The logistic container .may be handled by standard
burtoning cargo gear of the ship and by single fork-lift
trucks at the terminal or within the ship. The larger con
tainers require floating or resident heavy-lift gear at the
terminal, or cranes mounted on the ship. The ship-mounted
crane is preferable, since the ship's movements are then un^.
limited by port facilities. The use of shore-mounted cranes
restricts tire ship to specific ports, terminals, and berths.
The earlier concepts of design of marine refrigerated cargo
containers have borrowed heavily from the highway truck
builder's specifications, using ultra-light fibrous insulating
batting and an extensive use of wood furring to support the