Data Sheet No. 3.1.1 Effective January 1, 1967
3.1 INSTALLATION AND MAINTENANCE INSTRUCTIONS
FOR FULFLO VALVES Valves Type VJ, VB, VS, VJF, VBF, VSF, VJSP, VJFSP|
PLAINTIFF'S EXHIBIT
Fig. 3.1.1
CHV-62A
Installation
Fulflo. valves can be mounted in any position. A tee may be inserted in the pump discharge line to mount the valve. The correct size of valve should be installed, preferably matching the pump discharge line. Screw the valve into the nipple in' the tee,- or in the case of the "F" series, bolt the valve to the companion flange screwed into the nipple.. When the valve is used for frequent bypassing of oil under pressure, its out let should be piped back to the tank. 'Card must be taken to have the discharge well below the oil level in the tank to prevent air entrainment and'erratic operation.
Only if the valve .is used as safety or; overload relief and operates infrequently, its discharge may be piped back into the pump suction line.'Frequent or continuous operation under these conditions will cause exces sive heating of the oil and possible damage.
Maintenance
Standard valves are designed for use with mineral oils used in hydraulic and lubricating systems. For fire resisting fluids and other liquid media, -factory; recommendations for special trim or packings should be se cured. The liquid used must be free, of :abrasives;.or foreign matter and continuous filtration is recommended.
To dismantle valve for inspection bri cleaning:'
1. Remove cap "B"
V- i ' " '
2. Remove gasket "E" 4 (in. suffix" "R" valves, an. O-ring is used which is recessed into the cap)
3. Remove lock riut':*`F*A>;''.i'''-' '
4. Remove adjusting Screw "C" '
5. Remove retainer - "i>" '
'' '
=
6. Remove spring "G" 7. Remove piston "I" 8. Remove stop ring "H" (only if desired to replace it)
Inspect valve bore and piston for wear'and scoring. Replace broken or damaged parts. Clean all parts thoroughly and re-assemble by reversing the above procedure..
Setting Valves
Valves may be set with a hand pump, for cracking pressure. If a test stand is available, valve should be
connected to the discharge header, with.-the pump, bypass open, and the bypass gradually closed until the de
sired pressure registers on the gauge..; Adjust valve adjusting screw, until valve slightly bleeds at the set bypass
pressure, and lock adjusting screw.
-.
If valve is required to bypass a given amount of fluid at a given pressure, a test stand having a flow meter in the pump discharge line, must be! available. With valve adjusted for cracking pressure as above, continue closing bypass until the required flow registers on the; flow meter, and observe pressure. Re-adjust pressure, if necessary, to obtain desired pressure .at desired flow..
FULFLOTHE
* SPECIALTIES CO., INC., BLANCHESTER, OHIO, U. S. A.
CHEV BB 000021!
000212