Document VJNEDMYrmJD4VDk0JK6o1Dy3w

<?&lied. , mical MEMORANDUM date: subject: to: February 5, 1976 Ambient Air & Personnel Monitoring Mr. W. C. Koch RECElvED VCI MonomeF'- *"*' ^ Q. K* Attached is subject matter report for the month of January, 1976. P. B. Cornell, Manager Baton Rouge North Works KKTrrmcn Enc. cc: R. S. Christian A. J. LaVine AS I 00022387 GENERAL The purpose of the tests was to determine the TWA's for persons working in the VCM Complex. In addlt ion numbers and locations of excursions for the regulated area were taken by scanning the area monitoring GC charts. CONCLUSIONS A. Personnel Monitoring 1 . Fifteen employees were monitored in January. Range 0.0 to 0.5 ppm VCI 0.51 to 1.0 ppm VCI 1.0- over ppm VCI No. of Employees 15 0 0 % 100% 0 0 2. All employees tested in January were below the .5 ppm action level. 3. See data attached. B. VCM Area Monitoring 1. The VCM area monitors consist of two Bendix gas chromatographs having ten sample points each throughout the VCI Complex. 2. The chromatograph charts were scanned for excursions of VCI: a. Over 5 ppm extending over a 15 minute period. b. Over 1 ppm extending over an 8 hour period. c. See data attached. 0002^388 AS I Date 1/27 1/27 1/27 1/28 1/28 1/28 1/28 1/29 1/29 1/29 1/29 1/29 1/30 1/30 1/30 Name W. S . McDaniel R. Hawkins E . J. Armond J. Alford A. VGvasseur T. LeBeau S . Heath R. Ryan P. Brown H, J. Truxillo T, Morgan M. McDowell E. Loftin D. Bennett B. O'Quinn PERSONNEL MONITORING Soc . Sec . No. 433-68-2378 433-48-3546 436-38-4356 428-80-6634 437-48-7140 438-24-1651 227-50-5709 434-32-7022 434-56-3801 433-34-6805 437-72-7341 437-40-3216 438-54-6889 433-34-9786 437-60-5211 Total Hrs. Volume 6 18274 6 22037 6 17527 6 1625 6 16242 6 16112 6 18702 6 14151 6 12396 6 13775 6 2743 6 14578 6 16351 6 14546 6 18440 Remarks Lab Reboiler VCM Maint. VCM Elec. VCM Maint. VCM VCM Control VCM M&l VCM M&l VCM Elect. Lab VCM M&l VCM Control VCM Control VCM Control TWA VCI EDC 0.08 0.03 0.02 0.01 0.06 0.05 0.06 0.03 0.03 0.03 0.01 0.01 0.08 0.11 0.13 0.05 0.13 0.37 0.11 0.32 0.26 0.13 0.20 0.22 0.78 0.01 0.19 0.28 0.15 0.23 Monitor 1 . Chlorine compressor bldg. 2. Cell repair area 3. VCM Lab 4. Chlorine loading station 5. No. 5 vinyl loading station 6. No. 4 vinyl loading station 7. No. 3 vinyl loading station 8. No. 2 vinyl loading station 9. No. 1 vinyl loading station 10. EDC sump B. Monitor 1. Vinyl scrubbers 2. Vinyl loading pumps 3. Vinyl bullets 4. HCI neutralization pond 5. VCM control room 6. VCM GC sample system 7. Vinyl column reboilers 8. Lights column reboilers 9. Furnaces 0. Vinyl reflux pumps No. of Excursions over 5 ppm over 15 min. 0 0 0 0 1 0 0 0 0 0 No. of Continuous Excursions over 1 ppm over 8 hours 0 0 0 0 0 0 0 0 0 0 00 25 0 10 10 00 40 00 00 10 83 1 ASI 0223S9