Document VJLGqjvZgn0ja3RZrqyNnoMkN
558
CHAPTER 53
1962 Guide And Data Boole
necessary for the operator to be in position to wait on custom* ere in any part of the store. For this reason, the processing de partment should be so arranged that the operator can view any part of the store from where he is working. A glass partition around the processing room is suggested for this and for sani tary purposes.
A utility cooler, equipped with a double row of meat rails on each side, is required to hwrullp the needs of the plant as well as those of the retail store. It is 10 X ft with an 8K ft ceiling. The locker room is provided with 29 tiers of lockers, six high on the floor and with three tiers two high on top of the freezer cabinet. Door lockers are 17 in. high x 20 in. wide X 30 in. deep. Drawer lockers (two lower ones) are 23 in. high X 20 in. wide X 30 in. deep. Allowing a minimum of 17 in. for ceiling
plate evaporators plus 114 in. for lockers requires 10 ft 11 in. inside for ceiling height.
Hie floor is 19 X 8 ft, which allows sufficient floor space for
the lockers, a freezer cabinet and a 34 in. aisle with 1 in clear
ance allowed at back of lockers. The processing equipment
need be little more than required for a. small retail meat
store: a power grinder, scales, cutting blocks, work tables,
knives, and other hand tools. Such items as trackage, power
meat saws, smoke cabinets, lard rendering equipment and
other special items may not be required. In selecting such
equipment, it is best to consult with the operator who, if he is
an experienced butcher or meat cutter, will know what he will
need.
*
The refrigeration requirements are based on the following:
1. Theplant capacity is based on 120 lookers, plus a 25 percent additional volume of retail meat sales.
2. Peak ambient conditions 95 F, except floor over rmhuterf basement at 80 F for summer.
3. Water lor condensing unit, 70 F nuurtmtmi
4. Electric service: 220 volt, 3-phase, 60-cycle, and 110 volt, 1-phase, 60-cycle.
5. Desiea temperatures: CSiill room 35 F, locker room 0 F, freezing cabinet inside locker room, with shelf plates, --20 F.
6. Insulation: Chill room 4 in. corkboard; locker room 6 in. corkboard (or equivalent).
The refrigeration load is nunmariwd as follows:
Chill Room
LOAD
Heat leak and normal service, Btu per day
Product load at 2 lb per locker per day would equal 240
lb, with an addition of 25 percent for retail trade
" 300 lb. However, once an average weight of one
beef carcass is at least 500 lb, this weight
be
taken as the minimum product load for any chin
room. CSiill from 95 to 35 F, Btu
Total load, Btu per day Hourly load based on 18-hr compressor running time,
Btu
52,300
22,600 74,900
4161
As automatic defrosting is required in the chill room com pressor running time should not exceed 18 hr. The fan motor load may be added after cooling unit is npWfrpd
Freezer Cabinet
LOAD
Product bad, 2 lb per locker per day, reduced from 45
to OF, Btu Hourly bad, based on 24-hr compressor running
Btu
31,200 1300
Heat leak is disregarded, since the freezer cabinet is in stalled inside the locker room. Product load based on two lb per day per locker is the minimum allowable. In some experience shows, a heavier product load allowance may be advisable.
locker Room
LOAD
Heat leak phis light service only, Btu per day
162,060
Hourly load based on 24-hr compressor running tim,
Btu Q753
Automatic defrosting is not required, and calculations are based on peak ambient temperature; therefore, 24-hr com pressor running time may be used for freezer and locker room.
Refrigeration Equipment Selection
Condensing units. One unit is needed for chill room, with minimum capacity required of 4161 Btu per hr, plus fan motor load at refrigerant temperature of 18 F (15 F deg difference +2 F deg suction line drop; 35 F room --17 F deg difference = 18 F refrigerant).
A second unit to handle combined locker room and freezer load (6753+1300 =8053 Btu per hr total). This unit should be selected at -- 22 F refrigerant temperature. (20 F deg difference+2 F deg suction line drop; 0 F locker room --22 F deg difference = --22 F refrigerant.)
Either air-cooled or water-cooled units may be selected (condensing medium; air at 80 F if condensing unit is in base ment, at 95 F if not, or water at 70 F). By referring to manu facturers' condensing unit capacity tables, the proper models or sizes may be specified for the above. For example, one manufacturer shows a capacity of 5900 Btu per hr for a hp water-cooled unit at 18 F refrigerant and 70 F inlet water which might be used for the chill room; *nH another of 8540 Btu per hr for a 2 hp (3-phase) water-cooled unit at --22 F refrigerant and 70 F inlet water, which might be used for the locker room and freezer. (The display case may be connected to the chill room condensing unit by selecting the unit with sufficient additional capacity for that purpose, and by adding
lacker and Freezer Provisioning Plants
559
bettor refrigeration distribution above the 34 in. aisle. Each bnk of plates will require one thermostatic expansion valve.
A fair txifjmftte of the operating cost may be determined by dating the water and power usage (from manufacturers'
tables) on a 60 to 80 percent running time basis. This type plant does not require a complicated control
system. The condensing units may be equipped with low pressure control, since the cooling units have been equipped with thermostatic expansion valves. If fluctuations occur in locker room temperatures when a heavy load is put on the freezer, a thermostatically controlled solenoid valve should be inatftllpd in th<> suction or liquid line to the locker room
plates.
the proper controls for this type of multiple operation.) Total compressor horsepower, therefore, would be 2.5.
Cooling units. Gravity or forced air units may be used in the chill room. For this example, assume that the forced air type is used. The temperature difference between the chill room and the refrigerant should be 10-15 F deg. Thus, 5900 + 15 = 393 Btu is the required basic rating in. Btu per (hr) (degree difference) of the evaporator required to match the mnrlpnwiTig unit. A cooling unit having at least this ca pacity should be selected. The cooling unit selected from the manufacturer's tables has a basic rating of 400 Btu per (hr) (degree difference) with a 1/75 hp fan motor, and a motor heat dissipation of 222 Btu per hr. Since the fan is run continuously, the load from thin source is added to heat leak, plus product
load:
222 Btu per hr X 24 hr 18 (hr)
296 Btu per hr
The total load = 296 Btu per hr (fan load) + 4161 Btu per hr (beat leak + product load) = 4457 Btu per hr which is within the hourly capacity of the condensing unit selected. A thermostatic expansion valve is required.
Plates for the cabinet freezer may be selected from standard axes. The number of square feet of freezing surface may be based on the number of lockers. One square foot for each five lockers is the accepted practice for small plants of this kind, 120 -r 5 = 24 sq ft of plate needed--one side only. A {date 22 X 48 in. is standard, having 7.4 sq ft on one side. There fore, 24 + 7.4 = 3.2 plates needed (use 4). One thermostatic expansion valve is needed.
Overhead plates for the locker room may be selected from standard sizes. The rating may be obtained from manu facturer's data. Using figures published by one manufacturer, we may select {dates for this project as follows:
6753 ^ 2 X 24 X 20 "
The selection, therefore, from this size is seven plates, which be assembled in one bank. The 12 X 84 in. plate might
also be used. Thus:
6753 - 12
2 X 14 X 20
The selection from t-hia size is 12 plates assembled in two banks of six plates each. Either 144 or 84 in. plates may be
used on this project, with the latter having the advantage of
PLAN B--355 LOCKERS
Floor Plan B, Fig. 3 is for an average sized plant which may
be operated as a separate business or as a complementary part
of another business. A plant of this size is large enough to
require the full time of an attendant, providing additional
help may be available when needed during the peak season.
Under average conditions, the operator of such a plant will
have very little spare time for other responsibilities.
Facilities are provided in this layout for practically any
normal service that may be needed in a frozen food locker
plant, with the possible exception of slaughtering. Slaughter
ing facilities may be provided in a nearby location, at an out-
of-town location, or may be done on the customer's premises.
This plant is laid out in such a way aB to eliminate as much
trucking and bundling labor as possible. Chill and age rooms,
for example, are accessible to the delivery platform in the
rear, and the processing room is at the other end of the track.
The main track runs straight through so that the use of turns
and switches is reduced to a minimum. There is no insulation
in the partition between the chill room and the aging room.
A free-swinging door is installed between these two rooms.
Ceiling height is 9 ft. Four pounds per day per locker are used
as a basis for the refrigeration load in the chill and aging
rooms. This will take care of short-time holding for the cure
room and leave sufficient capacity to take care of peak require
ments for other refrigeration needs.
The smoke, cure, and lard work rooms are located in the
rear ni>a.r the refrigerated cured meat room. A small utility
kitchen is provided for the handling of fowl, fruits and -
vegetables. The refrigerated room for the storage of cured meats is
shown with enough wooden bins to accommodate 80 or
more customers. These bins should be constructed of hard
wood with removable bottoms or shelves to facilitate cleaning.
The shelves should be sloped so that the-drip will not fall on
the shelf beneath- They may be fitted to slope forward with a
trough to collect the drip and convey it to a portable re
ceptacle. Bin sizes are usually 24 in. wide,' 24 in. high, and 30
in. deep. Barrels or
for wet cure may be substituted for
all or part of the bins.
The locker room is provided with 355 lockers, and may be
entered from the lobby. Hence, all patrons entering the locker
room are in sight of the operator. Lockers for this room are
selected with five in each tier, consisting of two lower drawer-
type lockers 18 in. wide, 22 in. high and 30 in. deep, with three^
door-type lockers above 18 X 18 X 30 in. An additional group
of 10 door lockers is located above the freezer cabinet.
The freezer cabinet is located inside the locker room. Pro
vision is made for loading the freezer cabinets through s plug
or utility-type door. The practice of placing foods to be frozen