Document VJKapqKBYzZVE3emKxZm3rL28
Boilers, Steel
Monitor Boiler Company
Affiliated with UNITED Dry DOCKS, INC., NEW YORK
1505 Race Street
Philadelphia, Pa.
MONCO FIRE TUBE STEEL HEATING BOILERS, COIL STEEL HEATING BOILERS AND WATER HEATERS FOR COAL AND OIL BURNING
Mosaco Fire Tube Steel Heating Boilers are electrically welded and are designed according to the Code of the A. S. M. E. covering welded boilers and are constructed for a maximum working pressure of 15 lb. steam and 30 lb. water. All Boilers are constructed under the direct supervision of a Certified Insurance Inspector and are tested and stamped by this inspector before shipment.
The following are some of the out standing features:
Arched self-cleaning crown sheet. Large combustion chamber. Unrestricted circulation of water. Low water line. Large amount of direct heating surface. Long three-pass fife travel.
water on a mean temperature of 180 deg. as the water leaves the boiler. Any Monco Fire Tube Steel Heating Boiler will carry its full-rated load in direct radiation or equivalent, if sufficient radiation is in stalled to heat the building to 70 deg. fahr.
The standard equipment for coal burn ing boilers includes all castings as shown on boiler, heavy steel base and shaking grates. Standard steam trimmings in clude damper regulator, steam gauge with syphon, water column with gauge cocks and water glass, safety valve, tube, brush and firing tools. No trimmings furnished with hot water boilers.
Ratings are based on a standard for steam of 2 lb. pressure at the boiler and for
Monitor Boiler Company
Boilers, Steel
Grate Area, Sq. Ft. Heating Surface Diam. 1Smoke Breach 'g Diam , Stack Inches
M in.Ht.
Stack Feet Diam.
1
Smoke
Breach 'g
Diam. Stack Inches M in.Ht. Stack Feet Size 1 Steam Outlet Size Return Safety Valve No. Size i Covering Required
Sq. Ft.
Monco Fire Tube
Catalog Number
S. H. B. I. Steam
Ratings
Coal and Oil Burning Boilers
Steam Specifications
Shipping Weight
Approx.
One Boiler Coal or Oil
Two Boilers Coal or Oil '
Coal or Oil
Coal oil Coal Oil Coal OU
301-6 1360 1650 3250 2700 6.9 97 16 16 45 24 22 50
5 2-2'/z l-l'/z 46
302-6 1720 2090 3650 3000 8.0 123 16 16 50 24 22 55
5 2-2V2
56
303-6 2070 2520 4050 3300 9.0
401-6 2240 2720 4400 3550 10.7
402-6 2700 3280 4950 4000 12.1
403-6 3150 3830 5500 4550 17.1
404-6 3700 4490 6000 4900 13.5
405-6 4340 5270 6800 5700 13.5
406-6 4980 6050 7600 6400 14.9
421-5 471-6 5360 6510 8300 7000 163 472-5 472-6 6150 7460 8900 7450 18.0
423-5 473-6 6940 8430 9500 7900 19.7
551-6 8460 10270 11000 9200 71.5
552-5 552-6 9420 11440 12200 10300 23.0
553-5 553-6 10390 12610 13400 11500 23.0
651-6 11610 14090 15000 12950 252
652-5 652-6 12950 1573ft 16500 14250 77,6
653-6 14280 17340 18000 15550 799
740-5 740-6 16700 20280 20200 17550 31.9
741-5 742-5
7744126$
18650 20590
22640 25010
21800 23400
19150 20550
31 9 34,7
743-5 743-6 22540 27370 25000 21900 37 4
860-5 860-6 24680 29970 27200 23850 4ft.9
861-5 861-6 27380 33250 29000 25650 40.9 862-5 862-6 30080 36530 30800 26450 4ft 9
863-5 863-6 32790 39810 32600 29000 44.1
148
160 193
225 264
310 356 383
439 496
604 673
747. 879
925
107ft 1193
1332 <471
1610 1763 1956 2149
2342
16
18
18 18
20 20 20
22
22 22 24 24
24
28 28 28
30 30 30
30 36 36
36 36
16 55
18 50
18 55 18 60 20 55 20 60 20 65
22 60 22 65 22 70 24 65 24 70
24 75
26 75
26 80 26 85 28 80
26 85
28 90
28 95 34 90 34 95
34 100
34 110
24 26
26 26 28
28 28
34 34 34
36 36
36 38 38 38
42
42
42 42 52 52
52 52
22 60 24 55 24 60 24 65 26 60
26 65 26 70 32 65
32 70 32 75 34 70 34 75 34 80 36 80 36 85 36 90 40 85
40 90 40 95 40 100
50 95 50 too
50 110 50 120
5 WA I-I'/Z 6 2-3 1-1'A 6 2-3 1-2
66 67
78
6 2-3 1-2
90
6 2-3 1-2
94
6 2-3 1-2
107
6 2-3 8 2-4
'-2/r 120 l-2Vz 116
6 2-4 1-2V, 130
8 2-4 1-3
135
8 2-4 1-3
159
8 2-4 l-3'/z 174
8 2-4 l-J'/z 190
10 2-5 !-5'/r 192
10 2-5 2-3
210
10 2-5 2-3
228
10 2-5 2-3
239
10 2-5 2-3
251
10 2-5 2-3'/z 273
10 2-5
12 26 2-372
12 2-6 2-3'/2 335
12 2-6 2-4
12 1ft 2-4
400
Height Water Line--see FF in table below. Height Boiler--see C in table Mow. Length Boiler--see BB in table below. Width
Boiler--see A in table below.' To figure ratings of hot water boilers add 60 per cent to steam rating.
MotlCO Fire Tube Steel Healing Boiler for Coal.
and Oil .Burning
I
For Dimensions and
Specifications see following page
608
609