Boilers, Steel Monitor Boiler Company Affiliated with UNITED Dry DOCKS, INC., NEW YORK 1505 Race Street Philadelphia, Pa. MONCO FIRE TUBE STEEL HEATING BOILERS, COIL STEEL HEATING BOILERS AND WATER HEATERS FOR COAL AND OIL BURNING Mosaco Fire Tube Steel Heating Boilers are electrically welded and are designed according to the Code of the A. S. M. E. covering welded boilers and are constructed for a maximum working pressure of 15 lb. steam and 30 lb. water. All Boilers are constructed under the direct supervision of a Certified Insurance Inspector and are tested and stamped by this inspector before shipment. The following are some of the out standing features: Arched self-cleaning crown sheet. Large combustion chamber. Unrestricted circulation of water. Low water line. Large amount of direct heating surface. Long three-pass fife travel. water on a mean temperature of 180 deg. as the water leaves the boiler. Any Monco Fire Tube Steel Heating Boiler will carry its full-rated load in direct radiation or equivalent, if sufficient radiation is in stalled to heat the building to 70 deg. fahr. The standard equipment for coal burn ing boilers includes all castings as shown on boiler, heavy steel base and shaking grates. Standard steam trimmings in clude damper regulator, steam gauge with syphon, water column with gauge cocks and water glass, safety valve, tube, brush and firing tools. No trimmings furnished with hot water boilers. Ratings are based on a standard for steam of 2 lb. pressure at the boiler and for Monitor Boiler Company Boilers, Steel Grate Area, Sq. Ft. Heating Surface Diam. 1Smoke Breach 'g Diam , Stack Inches M in.Ht. Stack Feet Diam. 1 Smoke Breach 'g Diam. Stack Inches M in.Ht. Stack Feet Size 1 Steam Outlet Size Return Safety Valve No. Size i Covering Required Sq. Ft. Monco Fire Tube Catalog Number S. H. B. I. Steam Ratings Coal and Oil Burning Boilers Steam Specifications Shipping Weight Approx. One Boiler Coal or Oil Two Boilers Coal or Oil ' Coal or Oil Coal oil Coal Oil Coal OU 301-6 1360 1650 3250 2700 6.9 97 16 16 45 24 22 50 5 2-2'/z l-l'/z 46 302-6 1720 2090 3650 3000 8.0 123 16 16 50 24 22 55 5 2-2V2 56 303-6 2070 2520 4050 3300 9.0 401-6 2240 2720 4400 3550 10.7 402-6 2700 3280 4950 4000 12.1 403-6 3150 3830 5500 4550 17.1 404-6 3700 4490 6000 4900 13.5 405-6 4340 5270 6800 5700 13.5 406-6 4980 6050 7600 6400 14.9 421-5 471-6 5360 6510 8300 7000 163 472-5 472-6 6150 7460 8900 7450 18.0 423-5 473-6 6940 8430 9500 7900 19.7 551-6 8460 10270 11000 9200 71.5 552-5 552-6 9420 11440 12200 10300 23.0 553-5 553-6 10390 12610 13400 11500 23.0 651-6 11610 14090 15000 12950 252 652-5 652-6 12950 1573ft 16500 14250 77,6 653-6 14280 17340 18000 15550 799 740-5 740-6 16700 20280 20200 17550 31.9 741-5 742-5 7744126$ 18650 20590 22640 25010 21800 23400 19150 20550 31 9 34,7 743-5 743-6 22540 27370 25000 21900 37 4 860-5 860-6 24680 29970 27200 23850 4ft.9 861-5 861-6 27380 33250 29000 25650 40.9 862-5 862-6 30080 36530 30800 26450 4ft 9 863-5 863-6 32790 39810 32600 29000 44.1 148 160 193 225 264 310 356 383 439 496 604 673 747. 879 925 107ft 1193 1332 <471 1610 1763 1956 2149 2342 16 18 18 18 20 20 20 22 22 22 24 24 24 28 28 28 30 30 30 30 36 36 36 36 16 55 18 50 18 55 18 60 20 55 20 60 20 65 22 60 22 65 22 70 24 65 24 70 24 75 26 75 26 80 26 85 28 80 26 85 28 90 28 95 34 90 34 95 34 100 34 110 24 26 26 26 28 28 28 34 34 34 36 36 36 38 38 38 42 42 42 42 52 52 52 52 22 60 24 55 24 60 24 65 26 60 26 65 26 70 32 65 32 70 32 75 34 70 34 75 34 80 36 80 36 85 36 90 40 85 40 90 40 95 40 100 50 95 50 too 50 110 50 120 5 WA I-I'/Z 6 2-3 1-1'A 6 2-3 1-2 66 67 78 6 2-3 1-2 90 6 2-3 1-2 94 6 2-3 1-2 107 6 2-3 8 2-4 '-2/r 120 l-2Vz 116 6 2-4 1-2V, 130 8 2-4 1-3 135 8 2-4 1-3 159 8 2-4 l-3'/z 174 8 2-4 l-J'/z 190 10 2-5 !-5'/r 192 10 2-5 2-3 210 10 2-5 2-3 228 10 2-5 2-3 239 10 2-5 2-3 251 10 2-5 2-3'/z 273 10 2-5 12 26 2-372 12 2-6 2-3'/2 335 12 2-6 2-4 12 1ft 2-4 400 Height Water Line--see FF in table below. Height Boiler--see C in table Mow. Length Boiler--see BB in table below. Width Boiler--see A in table below.' To figure ratings of hot water boilers add 60 per cent to steam rating. MotlCO Fire Tube Steel Healing Boiler for Coal. and Oil .Burning I For Dimensions and Specifications see following page 608 609