Document VGyna0m13DzxyngZnwgNvX7dN
May 4, 1994
The attached form indicates when service maintenance was performed on the fire equipment located in your area. If you have any questions or need further information, please contact me at extension 8995 or the Fire Station, Building 2303.
Shane Tullier Fire Protection Building 2303 Phone 8995
To:_________________________________________________
Block 28 - Power I
The following Fire Equipment was tested on these dates.
Fire Extinguishers: January 12, 1994 Sprinkler Systems:___________________________________
Heat Test: June 9, 1993
Flow Test: June 9, 1993
SAP Readings:
Quarterly
Smoke Detectors: First Quarter
Hydrants and Deluge Guns:
August 10, 1993
DO A 117090 CONFIDENTIAL.
5/4194
22334 PM
Sprinkler Valve Inspection and Maintenance
Block 28 Power I System 1 #1 Turbine
Serial # 24-744
PSI 46
Valve Size 2.5
Gals Per Min 162
Vent Size 10
# of Circuits 1
____________________ Air Line Restrictions 15
05-01-89 05-01-90 11-01-91 11-11-92 04-16-93
Heat test. A-7, B-6, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:, Static: 70. Residual: 65. Drain Flow
Heat test. A-8, B-6, C-7, D-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 29. Static: 91. Residual: 88, Drain Flow
Heat test A-6, B-5, C-5, D-5 Taped Tubing, Changed Bad hangers & EA.D'S Flow test. SAP: 34. Static: 83. Residual: 80. Drain Flow
Heat test. A-8 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 80. Residual:. No Flow
Heat test, a-7 Taped Tubing, Changed Bad bangers & H.A.D'S Flow test. SAP: 30. Static: 75. Residual: 70. Drain Flow
DO A 117091 CONFIDENTIAL
1 13X40 PM
Sprinkler Valve Inspection and Maintenance
Block 28 Power I
System
_ ..
2 #2 Turbine
Serial # 25-604 Valve Size 2.5
Vent Size 10
05-01-89 05-01-90 11-01-91 11-11-92 04-16-93 05-03-93
09:17PM
Heat test. A-7, C-6, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 70. Residual: 67. Drain Flow
Heat test. A-6, B-6, C-4, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 23. Static: 90. Residual: 87. Drain Flow
Heat test. A-7, B-5, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 23. Static: 82. Residual: 78. Drain Flow
Heat test. A-6 B-7 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 80. Residual:. No Flow
Heat test. A-5, B-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 24. Static: 85. Residual: 75. Drain Flow
System Tripped: Cntrl Rm Wind speed: 1 . Wind direction: S. TRIPPED BY ACCIDENT Taped Tubing, Changed Bad hangers & H.A.D'S
PSI 50 Gals Per Min 196 # of Circuits 2 Air Line Restrictions 15
DO A 117092 CONFIDENTIAL
1 1:52y:4y0MPM
Sprinkler Valve Inspection and Maintenance
Block 28 Power I System 3 #1 Turbine Oil Reservoir
Serial # 24-743 Valve Size 2.5 Vent Size 10
05-01-89 05-01-90 11-01-91 11-11-92 04-16-93
Heat test. A-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 65. Residual: 55. Drain Flow Heat test. A-7 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 24. Static: 79. Residual: 44. Cleaned Nozzles Heat test. A-3 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 25. Static: 80. Residual: 78. Drain Flow
No Heat Test Due To Changing Of Mercury Checks Flow test. SAP: 29. Static: 80. Residual: 75. Drain Flow
Heat test. A-3 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 80. Residual: 75. Drain Flow
PSI 48 Gals Per Min 164 # of Circuits 1 Air Line Restrictions 15
DO A 117093 CONFIDENTIAL
1 S/S/94 1:52 40 PM
Sprinkler Valve Inspection and Maintenance
Block 28 Power I System 5 Aux Transformer
Serial # 24-746 Valve Size 2.5 Vent Size 10
05-01-89 05-01-90 11-01-91 11-11-92 04-16-93
Heat test. A-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 65. Residual: 56. Drain Flow
Heat test. A-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 26. Static: 78. Residual: 60. Cleaned Nozzles
Heat test. A-2 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 28. Static: 80. Residual: 77. Drain Flow
No Heat Test Due To Changing Of Mercury Checks Flow test. SAP: 24. Static: 79. Residual: 76. Drain Flow
Heat test. A-4 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 24. Static: 80. Residual: 75. Drain Flow
PSI 52 Gals Per Min 386 # of Circuits 1 Air Line Restrictions 15
DO A 117094 CONFIDENTIAL
1 VVM 1:32:40 PM
Sprinkler Valve Inspection and Maintenance
Block 28 Power I System 6 #3 & 4 Hydrogen Seal
Serial # 26-610 Valve Size 2.5 Vent Size 10
05-01-89 05-01-90 11-01-91 11-11-92 11-11-92 04-16-93
Heat test. A-7, B-6, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 70. Residual: 65. Drain Flow
Heat test. A-6, B-8 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 26. Static: 78. Residual: 67. Cleaned Nozzles
Heat test A-2 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 27. Static: 80. Residual: 75. Drain Flow
Heat test. A-7 B-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 85. Residual:. No Flow
Heat test. A-7, B-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 85. Residual:. No Flow
Heat test. A-6, B-7 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 30, Static: 75. Residual: 70. Drain Flow
PSI 50 Gals Per Min 380 # of Circuits 2 Air Line Restrictions 15
DO A 1170QC confident i A(5 1 5W94
1:52:40 PM
Sprinkler Valve Supervisory Air Pressure
Block and System 28 - Power I 1 - #1 Turbine 28 - Power I 2 - #2 Turbine 28 - Power I 3 - #1 Turbine oil reservoir 28 - Power I 5 - Aux Transformer 28 * Power I 6 - #3 & 4 hydrogen seal
Year 93 93 93 93 93
1st Qtr SAP S R
30 86 80 25 82 77 27 90 84 26 90 85 26 90 64
2nd Qtr SAP S R
36 85 81 24 85 79 30 90 85 29 90 86 24 89 82
3rd Qtr SAP SR
30 80 74 24 80 73 24 92 83 30 90 85 30 80 76
4th Qtr SAP S R
29 80 73 24 80 72 26 90 82 30 90 84 36 80 75
00 A 117096 CNFlDFNTrAL
1 10:03:22 AM
POWER I - BLOCK 28
THE FOLLOWING TYPES OF EXTINGUISHERS ARE FOUND IN THIS BLOCK.
1/94 SERVICED BY : DOOLEY TACKABERRY
20# C02 - FIXED 11 10# FORAY 43 15# C02 18 20# DC 4 150# DC 6 9#HALON
STA NO TYPE
1A 9# HALON 2 15# C02 3 15# C02 4 15# C02 5 15# C02 6 15# C02 7 15# C02 8 20# DC 9 15# C02 10 150# DC 11 20# DC 12 15# C02 13 15# C02 14 20# DC 15 150# DC 16 20# DC 17 15# C02 18 15# C02 19 15# C02 20 15# C02 21 150# DC 22 20# DC 23 15# C02 24 15# C02 25 20# DC 27 15# C02 29 20# DC 30 15# C02 31 15# C02 32 15# C02 33 15# C02 34 150# DC 35 15# C02 36 20# DC 37 20# DC 38 20# DC
LOCATION
HALLWAY-OFFICE
2ND LEVEL - E DOOR, CONTROL ROOM
CENTER - UPPER FIRING AISLE, N SIDE CONTROL RM
E END UPPER FIRING AISLE #1 BOILER
E END UPPER FIRING AISLE #1 BOILER W END UPPER FIRING AISLE #3 BOILER
2ND LEVEL - W DOOR, OUTSIDE CONTROL ROOM
W DOOR OUTSIDE C/ROOM - 2ND LEVEL
W DOOR OUTSIDE C/ROOM - 2ND LEVEL
D81/N82
2ND LEVEL-EOF TURBINE #1
2ND LEVEL - WALL N OF TURBINE #1
2ND LEVEL- WALL N OF TRUBINE #1
2ND LEVEL - SOUTH OF TURBINE #1
2ND LEVEL- SW OF TURBINE #2
D85/N85
2ND LEVEL-W OF TURBINE #2
2ND LEVEL - WALL N OF TURBINE #2
2ND LEVEL - WALL N OF TURBINE #2
LOWER FIRING AISLE- SW CORNER - BOILER #3
LOWER FIRING AISLE- SE CORNER - BOILER #2
LOWER FIRING AISLE- #1 BOILER
D78/N87
2ND LEVEL BETWEEN TURBINES 3 # 4
2ND LEVEL - S OF TURBINE #3
2ND LEVEL - N OF TURBINE #3 2ND LEVEL - N OF TURBINE #4
2ND LEVEL - S OF TURBINE #4
S DOOR- #1 AUXILARY CONTROL ROOM
GROUND LEVEL - S OF OIL RES - TURBINE #1
NEAR #1 HOGGER
EOFH2 CYLINDERS -#1 GENERATOR
N OF C02 CYLINDERS - #1 GENERATOR
E OF #1 EXCITER
D78/N84
E AUX. BAY-BETWEENH2 CAB. #1 & #2
N OF H2 CYLINDERS - #2 GENERATOR
N OF H2 CYLINDERS - #2 GENERATOR
N OF OIL RESERVOIR - #2 TURBINE W OF OIL RESERVOIR - #2 TURBINE
\\70U
A COMF1
.lfiinTttal
39 40 41 42 43 44 45 46 47 48 49 50 51 52 54 55 63 64 65 66 67 68 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 88
5 (2) 6 7 8 9 11 12
15# C02 15# C02 15# C02 15# C02 20# DC 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# DC 15# C02 20# DC 10# FORAY 15# C02 20# DC 20# DC 15# C02 10# FORAY 10# FORAY 10# FORAY 15# C02 15# C02 15# C02 20# DC 15# C02 9#HALON 9#HALON 10# FORAY 10# FORAY 10# FORAY 10# FORAY 15# C02 15# C02 20# DC 10# FORAY 9# HALON [2]
20# DC 10# FORAY 10# FORAY 9# HALON 15# C02 10# FORAY 9# HALON
W DOOR - #1 15KV SWITCHGEAR ROOM N DOOR - #1 15KV SWITCHGEAR ROOM E DOOR - #1 15KV SWITCHGEAR ROOM #1-2 CIRCUATOR SLAB - ON N. CANAL RD SE OF OIL RESERVOIR - #3 TURBINE N DOOR #2 2400V SWITCHGEAR ROOM COLUMN BETWEEN 2400V BUSES #3 & #4 S OF C02 CYLINDERS - #3 GENERATOR NW DOOR 2400V SWITCHGEAR ROOM SW DOOR 2400V SWITCHGEAR ROOM N WALL - #2 15KV SWITCHGEAR ROOM E DOOR - #2 15KV SWITCHGEAR ROOM S WALL - #2 15KV SWITCHGEAR ROOM S OF OIL RESERVOIR - #4 TURBINE S DOOR - #2 AUXILARY ROOM CIRCULATORS 3A &3B - ON N. CANAL RD I-BEAM N OF #3 BOILER OUTSIDE - OIL STOR. SHED W OF SHOP CENTER - WHSE. - UPSTAIRS SE CORNER OF SHOP MATERIAL CONTROLLER'S OFF. TOWMOTOR #1097 DMLBLDG. FIRE WATCH - WHSE. FIRE WATCH - WHSE. FIRE WATCH-WHSE. FIRE WATCH - WHSE. COMPUTER ROOM COMPUTER ROOM E WALL-ELEC. SHOP W WALL-ELEC. SHOP E WALL - ELEC. OFFICES W WALL - ELEC. OFFICES SW DOOR WHSE. NW DOOR WHSE. BLK 28 DISTILLATE DRUM SW END OF BLOCK INSIDE FENCED AREA IN WAREHOUSE BLDG 2809 S/E CORNER OF BLOCK
* BLDG. 2805 *
STORAGE AREA S OF BLDG 2805 SOUTH DOOR HALLWAY COPIER ROOM AIRCOND. ROOM NORTH OF LUNCHROOM BLDG 2803
DO A 117098 CONFIDENTIAL
THIS IS WATER TREATING PLANT FIRE EXTINGUISHER REPORT
9/93 SERVICED BY: DOOLEY TACKABERRY
THE FOLLOWING EXTINGUISHERS ARE FOUND IN THE PLANT:
7 10# FORAY 7 15# C02 10 20# DRY CHEM 3 9# HALON
STA NO
l 2 3 3A 4 5 6 7 8 9 10 11 12 13 14 15
16 17 18 19 20 21
TYPE
10# FORAY 10# FORAY 9# HALON 9# HALON 20# DC 20# DC 9# HALON 20# DC 10# FORAY 15# C02 10# FORAY 10# FORAY 20# DC 20# DC 20# DC 15# C02
15# C02 15# C02 (2) 15# C02 (2) 15# C02 15# C02 15# C02
LOCATION
HST COMMENTS
IN HALL NEAR LUNCH ROOM, BLDG 1801 OFFICE, BLDG 1801 EAST DOOR CONTROL ROOM BLDG 1801 S DOOR BLDG. 1801 COLUMN OVERHEAD PIPEWAY CHLORINE CYLINDRES SW DOOR BLDG. 1801 OIL STORAGE NW OF BLDG 1801 SE DOOR OF NEW WHSE WEST DOOR OF NEW WHSE SW DOOR OF NEW WHSE NORTH WALL, 2ND FLOOR NEW WHSE INTAKE PUMPS SOUTH SIDE CLARIFIER PLATFORM WEST WALL OUTSIDE SW DOOR BLDG 1801 WEST ACID NEUTRALIZATION TANK BY MCC BASE OF STAIRS IN WAREHOUSE W WALL OUTSIDE NW DOOR BLDG 1801 E DOOR WHSE FIREWATCH E DOOR WHSE FIREWATCH BLDG. 1804 MCC E DOOR MCC BLDG 1804
BLOCK 35 WATER TREATING CLARIFIER AREA
00 A 117099 CONFIDENTIAL
1 10# FORAY 2 15# C02 3 20# DRY CHEMICAL
STA NO
1 2 3 4 5
6
TYPE
15# C02 15# 002 20# DC 20# DC 20# DC
10# FORAY
LOCATION
HST COMMENTS
CENTER DOOR CONTROL ROOM WEST DOOR CONTROL ROOM (OUTSIDE) WEST STAIRS TO CLARIFIER SE STAIRS TO CLARIFIER WEST STAIRWAY TO INTAKE PUMPS AND CHEMICAL FEED OUTSIDE BLDG 3502-T
STA. NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22
TYPE
15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 15# C02 20# DC 15# C02
SUB STATIONS & WATER WELLS 1 10#FORAY 19 15# C02 10 20# DC 1 50# C02
LOCATION
SE CORNER BLK 26 - SS #1 SE CORNER BLK 36 - SS #2 SE CORNER BLK 38 - SS #3 SW CORNER BLK 46 - SS #4 N END OF GLYCOL ROAD - SS #5 SE CORNER BLK 29 - SS #6 BLK 9 BLDG 920 (OUTSIDE) - SS #7 SE CORNER BLK 17 - SS #8 E WALL OUTSIDE BLK 47 - SS #10 NW CORNER BLK 47 - SS #10 BLOCK 8 - WW #1 BLOCK 28-WW #2 BLOCK 48-WW #3 BLOCK 45-WW #4 BLOCK 86 - WW #5 BLOCK 80 - WW #6 BLOCK 110-WW #7 ACROSS FROM GATE 4 - WW #8 BLOCK 56 - WW #9 RETURN PUMP SUB STATION GAS METERING STATION BLK 48 RETURN PUMP MOTOR PLATFORM
HST COMMENTS
DO A 117100 CONFIDENTIAL
23 50# C02 INTAKE PUMP PLATFORM 24 15# C02 INTAKE PLATFORM NORTH RAIL 25 15# C02 INTAKE PLATFORM WEST RAIL 26 15# C02 INTAKE PLATFORM ENTRANCE SOUTH 27 10# FORAY ROVING OPERATOR TRUCK 29 15# C02 INTAKE LEVEE 30 15# C02 RETURN LEVEE 31 15# C02 NITROGEN (OUTSIDE GATE 9) 32 15# C02 GULF STATES SUB fINSIDEl S/DOOR
*********** END ***********
.xy\0\
---------- ,,---------------------------------------- --------------
170 TlMti- 9/mi
Swum 1 - fen M1S7 Kou. UiMm N
CHinuwMa
A
HLnimiw*
ton *'***" UUCM1WI
Hum Hull WMI
(9M) Ml'MSl tax (smj isi-oan
/ ^PHOC ORDER TAKEN BY
UUMJ W ^ULV-olc=;
DATE OF ORDER <7-/2-<F*s
CUSTOMER'S ORDER
`N
Sr*SC y?d7. 'Srv ?~ cs-7
/J/SO^sv'cSS7&r
TERMS:
Qoay work JOB NAME/NUMBER
contract *
-
J06LOCATON
job more ^---------------------------------------------------------------------------------------
STARTS DATE
tOFfO
extra
)
mm
>
S.-
jii3 AMOU ^IJI^l^cPTOMwoRtc
;; ^;
s/* (ft fe s*-
1 //^^7^r/` --
/Op-dO
#l^-o~/a&rue<*r </
'
'sv ~Zt/ SZ-^TitJ. -
. *rftO' `
e*Aj-c>*t. /2^T
QyS
/ z, *>4*?)
JSL
6-
/Of/C-tf'
- Se'1
/T?/-/ *fc<r y^C/A'C /?zt cO/Jl
>
z/v *$//-
/
*
*
/) /? /i T tv^
-?
//c. / 1
/-?/' / d/sir/'A'f/' #?>* f A
2/*' $?/rf/Li
S/CU/________________ 1 //s* <Je
^'C
/??c U /3; >* ~Z3C r/~- /^
'/? 'vfA ^
'dX
5> 'x^y^-^cJercS S?& c. ^f*~f>s*Kr T
7/6^?c*
------- - - ........
^ ^ T1^-------- -- ^-----;--'-<--r-c--J-r--<-/
AS/vs/
7" /fttyysO /Pyy^r s< /^n^U/Cc .
. ri3^IomER(>IARGES
ok 5
//'sis/0
7^' Z?AT y /'^5t5i<r/*t^
r,
5
76 < /0OdSS>y~ s*s
V&f /%
-rvV-j/v'^rr
TOTAL OTHER
LABOR
*/
HRS. RATE
i~</?
AMOUNT
^ -4-tfs9 C*sUS-
A~x*=-'o3 C 7
6
W3 -
DATE COMPLETED
TOTAL MATERIALS
Wo rkr nrrinrnH bv Q'T-.Q^ StnnntiifA -Aa /
1 hereby acknowledge the satisfactory completion of the above described work
raoouci 2u //viMSiiK, cm, hub qmn fe Onto PHOWE TOU ntEM + W777SLJSC
TOTAL LABOR TOTAL MATERIALS
TOTAL OTHER
(7lMa/Sf^ow
TAX TOTAL
DO A 117102 CONFIDENTIAL
Bourgeois A AModatM, be. WMtwmian
Ms* i -1 inff
$
UCM
rAMZptiMMS) -HMIM4M
TO
/^C? /2>c<s ^Z0V~?
/4vZ~.
<^/' &>t/~?
<J[I} OOWOOOl
(wext, _ _
OH30< TAKEN Y
OAItOfOHDBl customs** order hjmct
"\
EJeAY WORK
CONTRACT
MAKEJOB
/NUMBER
*?&/ >QaAi/
joblocaton
' > y
_
&/<4 ze0&
EXTRA
jK _ ,.
ig i- V
joemof l
' mnvopKTE
J
/?u)ajAa)aa)ce
g/<P
/^V>Ct/r
Ztjuc/f>/v ZP?><
<7^ 2>g
______^
mm
/? /
0 &&*
<r"'
! LABOR '
TOTAL OTHER -*'"r *- *
' V HRS. RATE AMOUNT
> -2.
^ cr^ cc ^
^ ^ c/^> '(/i.vr
< c^cerr *>&-?
DATE COMPLETED
TOTAL MATERIALS
woffc nrrinrori hy
Q-r' CO
signature ...
-\ V^vA
1 hereby acknowledge the satisfactorf completion of the above described work.
M (Mm PHOUt MU. ll + 0U&4
--------
_
TOTAL LABOR (. J 1 TOTAL MATERIALS
; TOTAL OTHER
CEMat^y&w
TAX TOTAL
DO A 117103 CONFIDENTIAL.
Bourgoob * Amodatot, toe. CXAJTOJIHCWM* Read
14117
oJ[D H[iW@D@
IW4J FAX (SM) Ul-OM*
d2/jOcc^ >
Si/'C'*-/*
/^'V' -2<r<S-7 /*/ </&> *//- -Z*/7
TERMS:
fcJPTTts: >
' *r**
PRI
^PHOtC
OiTIOFOFIDEB ^V-GFrS.
"\
ORDER TAKEN BY
0-DAY WORK
JOBNAk*/NUMBSt <?</-*&>/
CUSTOMER* OfCS
/ 7/?/7Q/__________
CONTRACT
EXTRA
&xo-*.JT /t^s- -z-e
JOB LOCATION jOBmoec
.>
?gr*S
' STARTING DATE V-S/- <Pes
J
i1
I
1*
-r --w-
AMOU ttl
*/ /??/ SS<J7nJS? si r f
r* /^c/Cc^i &*_> /=r,/Z4.-j/-- 7/0
^1'< /t* *. _ /r r /^UAJC./'es* 77*
(77' ?/o /'-Tv-sOed. 0n*/rt*r
^ jdh M (*+
w^. >.
i,vi*yyi.'gi yaaBFg' " "
T f*_ -.
. -- y.
OTHER CHARGES 1 *
/7/Z 777*5^
d/Ar (7
J^r/t
yC? e~/<"/p5~
. *:
TOTAL OTHER
LABOR
HRS. RATE AMOUNT
> 2- i
C^Gccrc, Z6 *? /TszTTti-r sO/f~-
T>ctr<y 3d. 7
DATE COMPLETED
1
TOTAL MATERIALS |
Woirtt ordered tav
&T-..SK3'.
Ml_____A____
1 hereby Acknowledge the satisfactory completion of the above described work-
"mow
taxitm tun
la 04* WOW mi ftf I + fcnmiiw
I I
TOTAL LABOR TOTAL MATERIALS
TOTAL OTHER
C3Kan^f^ow
TAX
TOTAL QQ ^
CONFIDFNTTAL