Document VGyna0m13DzxyngZnwgNvX7dN

May 4, 1994 The attached form indicates when service maintenance was performed on the fire equipment located in your area. If you have any questions or need further information, please contact me at extension 8995 or the Fire Station, Building 2303. Shane Tullier Fire Protection Building 2303 Phone 8995 To:_________________________________________________ Block 28 - Power I The following Fire Equipment was tested on these dates. Fire Extinguishers: January 12, 1994 Sprinkler Systems:___________________________________ Heat Test: June 9, 1993 Flow Test: June 9, 1993 SAP Readings: Quarterly Smoke Detectors: First Quarter Hydrants and Deluge Guns: August 10, 1993 DO A 117090 CONFIDENTIAL. 5/4194 22334 PM Sprinkler Valve Inspection and Maintenance Block 28 Power I System 1 #1 Turbine Serial # 24-744 PSI 46 Valve Size 2.5 Gals Per Min 162 Vent Size 10 # of Circuits 1 ____________________ Air Line Restrictions 15 05-01-89 05-01-90 11-01-91 11-11-92 04-16-93 Heat test. A-7, B-6, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:, Static: 70. Residual: 65. Drain Flow Heat test. A-8, B-6, C-7, D-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 29. Static: 91. Residual: 88, Drain Flow Heat test A-6, B-5, C-5, D-5 Taped Tubing, Changed Bad hangers & EA.D'S Flow test. SAP: 34. Static: 83. Residual: 80. Drain Flow Heat test. A-8 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 80. Residual:. No Flow Heat test, a-7 Taped Tubing, Changed Bad bangers & H.A.D'S Flow test. SAP: 30. Static: 75. Residual: 70. Drain Flow DO A 117091 CONFIDENTIAL 1 13X40 PM Sprinkler Valve Inspection and Maintenance Block 28 Power I System _ .. 2 #2 Turbine Serial # 25-604 Valve Size 2.5 Vent Size 10 05-01-89 05-01-90 11-01-91 11-11-92 04-16-93 05-03-93 09:17PM Heat test. A-7, C-6, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 70. Residual: 67. Drain Flow Heat test. A-6, B-6, C-4, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 23. Static: 90. Residual: 87. Drain Flow Heat test. A-7, B-5, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 23. Static: 82. Residual: 78. Drain Flow Heat test. A-6 B-7 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 80. Residual:. No Flow Heat test. A-5, B-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 24. Static: 85. Residual: 75. Drain Flow System Tripped: Cntrl Rm Wind speed: 1 . Wind direction: S. TRIPPED BY ACCIDENT Taped Tubing, Changed Bad hangers & H.A.D'S PSI 50 Gals Per Min 196 # of Circuits 2 Air Line Restrictions 15 DO A 117092 CONFIDENTIAL 1 1:52y:4y0MPM Sprinkler Valve Inspection and Maintenance Block 28 Power I System 3 #1 Turbine Oil Reservoir Serial # 24-743 Valve Size 2.5 Vent Size 10 05-01-89 05-01-90 11-01-91 11-11-92 04-16-93 Heat test. A-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 65. Residual: 55. Drain Flow Heat test. A-7 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 24. Static: 79. Residual: 44. Cleaned Nozzles Heat test. A-3 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 25. Static: 80. Residual: 78. Drain Flow No Heat Test Due To Changing Of Mercury Checks Flow test. SAP: 29. Static: 80. Residual: 75. Drain Flow Heat test. A-3 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 80. Residual: 75. Drain Flow PSI 48 Gals Per Min 164 # of Circuits 1 Air Line Restrictions 15 DO A 117093 CONFIDENTIAL 1 S/S/94 1:52 40 PM Sprinkler Valve Inspection and Maintenance Block 28 Power I System 5 Aux Transformer Serial # 24-746 Valve Size 2.5 Vent Size 10 05-01-89 05-01-90 11-01-91 11-11-92 04-16-93 Heat test. A-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 65. Residual: 56. Drain Flow Heat test. A-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 26. Static: 78. Residual: 60. Cleaned Nozzles Heat test. A-2 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 28. Static: 80. Residual: 77. Drain Flow No Heat Test Due To Changing Of Mercury Checks Flow test. SAP: 24. Static: 79. Residual: 76. Drain Flow Heat test. A-4 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 24. Static: 80. Residual: 75. Drain Flow PSI 52 Gals Per Min 386 # of Circuits 1 Air Line Restrictions 15 DO A 117094 CONFIDENTIAL 1 VVM 1:32:40 PM Sprinkler Valve Inspection and Maintenance Block 28 Power I System 6 #3 & 4 Hydrogen Seal Serial # 26-610 Valve Size 2.5 Vent Size 10 05-01-89 05-01-90 11-01-91 11-11-92 11-11-92 04-16-93 Heat test. A-7, B-6, C-6, D-5 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 70. Residual: 65. Drain Flow Heat test. A-6, B-8 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 26. Static: 78. Residual: 67. Cleaned Nozzles Heat test A-2 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test SAP: 27. Static: 80. Residual: 75. Drain Flow Heat test. A-7 B-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 85. Residual:. No Flow Heat test. A-7, B-6 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP:. Static: 85. Residual:. No Flow Heat test. A-6, B-7 Taped Tubing, Changed Bad hangers & H.A.D'S Flow test. SAP: 30, Static: 75. Residual: 70. Drain Flow PSI 50 Gals Per Min 380 # of Circuits 2 Air Line Restrictions 15 DO A 1170QC confident i A(5 1 5W94 1:52:40 PM Sprinkler Valve Supervisory Air Pressure Block and System 28 - Power I 1 - #1 Turbine 28 - Power I 2 - #2 Turbine 28 - Power I 3 - #1 Turbine oil reservoir 28 - Power I 5 - Aux Transformer 28 * Power I 6 - #3 & 4 hydrogen seal Year 93 93 93 93 93 1st Qtr SAP S R 30 86 80 25 82 77 27 90 84 26 90 85 26 90 64 2nd Qtr SAP S R 36 85 81 24 85 79 30 90 85 29 90 86 24 89 82 3rd Qtr SAP SR 30 80 74 24 80 73 24 92 83 30 90 85 30 80 76 4th Qtr SAP S R 29 80 73 24 80 72 26 90 82 30 90 84 36 80 75 00 A 117096 CNFlDFNTrAL 1 10:03:22 AM POWER I - BLOCK 28 THE FOLLOWING TYPES OF EXTINGUISHERS ARE FOUND IN THIS BLOCK. 1/94 SERVICED BY : DOOLEY TACKABERRY 20# C02 - FIXED 11 10# FORAY 43 15# C02 18 20# DC 4 150# DC 6 9#HALON STA NO TYPE 1A 9# HALON 2 15# C02 3 15# C02 4 15# C02 5 15# C02 6 15# C02 7 15# C02 8 20# DC 9 15# C02 10 150# DC 11 20# DC 12 15# C02 13 15# C02 14 20# DC 15 150# DC 16 20# DC 17 15# C02 18 15# C02 19 15# C02 20 15# C02 21 150# DC 22 20# DC 23 15# C02 24 15# C02 25 20# DC 27 15# C02 29 20# DC 30 15# C02 31 15# C02 32 15# C02 33 15# C02 34 150# DC 35 15# C02 36 20# DC 37 20# DC 38 20# DC LOCATION HALLWAY-OFFICE 2ND LEVEL - E DOOR, CONTROL ROOM CENTER - UPPER FIRING AISLE, N SIDE CONTROL RM E END UPPER FIRING AISLE #1 BOILER E END UPPER FIRING AISLE #1 BOILER W END UPPER FIRING AISLE #3 BOILER 2ND LEVEL - W DOOR, OUTSIDE CONTROL ROOM W DOOR OUTSIDE C/ROOM - 2ND LEVEL W DOOR OUTSIDE C/ROOM - 2ND LEVEL D81/N82 2ND LEVEL-EOF TURBINE #1 2ND LEVEL - WALL N OF TURBINE #1 2ND LEVEL- WALL N OF TRUBINE #1 2ND LEVEL - SOUTH OF TURBINE #1 2ND LEVEL- SW OF TURBINE #2 D85/N85 2ND LEVEL-W OF TURBINE #2 2ND LEVEL - WALL N OF TURBINE #2 2ND LEVEL - WALL N OF TURBINE #2 LOWER FIRING AISLE- SW CORNER - BOILER #3 LOWER FIRING AISLE- SE CORNER - BOILER #2 LOWER FIRING AISLE- #1 BOILER D78/N87 2ND LEVEL BETWEEN TURBINES 3 # 4 2ND LEVEL - S OF TURBINE #3 2ND LEVEL - N OF TURBINE #3 2ND LEVEL - N OF TURBINE #4 2ND LEVEL - S OF TURBINE #4 S DOOR- #1 AUXILARY CONTROL ROOM GROUND LEVEL - S OF OIL RES - TURBINE #1 NEAR #1 HOGGER EOFH2 CYLINDERS -#1 GENERATOR N OF C02 CYLINDERS - #1 GENERATOR E OF #1 EXCITER D78/N84 E AUX. BAY-BETWEENH2 CAB. #1 & #2 N OF H2 CYLINDERS - #2 GENERATOR N OF H2 CYLINDERS - #2 GENERATOR N OF OIL RESERVOIR - #2 TURBINE W OF OIL RESERVOIR - #2 TURBINE \\70U A COMF1 .lfiinTttal 39 40 41 42 43 44 45 46 47 48 49 50 51 52 54 55 63 64 65 66 67 68 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 88 5 (2) 6 7 8 9 11 12 15# C02 15# C02 15# C02 15# C02 20# DC 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# DC 15# C02 20# DC 10# FORAY 15# C02 20# DC 20# DC 15# C02 10# FORAY 10# FORAY 10# FORAY 15# C02 15# C02 15# C02 20# DC 15# C02 9#HALON 9#HALON 10# FORAY 10# FORAY 10# FORAY 10# FORAY 15# C02 15# C02 20# DC 10# FORAY 9# HALON [2] 20# DC 10# FORAY 10# FORAY 9# HALON 15# C02 10# FORAY 9# HALON W DOOR - #1 15KV SWITCHGEAR ROOM N DOOR - #1 15KV SWITCHGEAR ROOM E DOOR - #1 15KV SWITCHGEAR ROOM #1-2 CIRCUATOR SLAB - ON N. CANAL RD SE OF OIL RESERVOIR - #3 TURBINE N DOOR #2 2400V SWITCHGEAR ROOM COLUMN BETWEEN 2400V BUSES #3 & #4 S OF C02 CYLINDERS - #3 GENERATOR NW DOOR 2400V SWITCHGEAR ROOM SW DOOR 2400V SWITCHGEAR ROOM N WALL - #2 15KV SWITCHGEAR ROOM E DOOR - #2 15KV SWITCHGEAR ROOM S WALL - #2 15KV SWITCHGEAR ROOM S OF OIL RESERVOIR - #4 TURBINE S DOOR - #2 AUXILARY ROOM CIRCULATORS 3A &3B - ON N. CANAL RD I-BEAM N OF #3 BOILER OUTSIDE - OIL STOR. SHED W OF SHOP CENTER - WHSE. - UPSTAIRS SE CORNER OF SHOP MATERIAL CONTROLLER'S OFF. TOWMOTOR #1097 DMLBLDG. FIRE WATCH - WHSE. FIRE WATCH - WHSE. FIRE WATCH-WHSE. FIRE WATCH - WHSE. COMPUTER ROOM COMPUTER ROOM E WALL-ELEC. SHOP W WALL-ELEC. SHOP E WALL - ELEC. OFFICES W WALL - ELEC. OFFICES SW DOOR WHSE. NW DOOR WHSE. BLK 28 DISTILLATE DRUM SW END OF BLOCK INSIDE FENCED AREA IN WAREHOUSE BLDG 2809 S/E CORNER OF BLOCK * BLDG. 2805 * STORAGE AREA S OF BLDG 2805 SOUTH DOOR HALLWAY COPIER ROOM AIRCOND. ROOM NORTH OF LUNCHROOM BLDG 2803 DO A 117098 CONFIDENTIAL THIS IS WATER TREATING PLANT FIRE EXTINGUISHER REPORT 9/93 SERVICED BY: DOOLEY TACKABERRY THE FOLLOWING EXTINGUISHERS ARE FOUND IN THE PLANT: 7 10# FORAY 7 15# C02 10 20# DRY CHEM 3 9# HALON STA NO l 2 3 3A 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 TYPE 10# FORAY 10# FORAY 9# HALON 9# HALON 20# DC 20# DC 9# HALON 20# DC 10# FORAY 15# C02 10# FORAY 10# FORAY 20# DC 20# DC 20# DC 15# C02 15# C02 15# C02 (2) 15# C02 (2) 15# C02 15# C02 15# C02 LOCATION HST COMMENTS IN HALL NEAR LUNCH ROOM, BLDG 1801 OFFICE, BLDG 1801 EAST DOOR CONTROL ROOM BLDG 1801 S DOOR BLDG. 1801 COLUMN OVERHEAD PIPEWAY CHLORINE CYLINDRES SW DOOR BLDG. 1801 OIL STORAGE NW OF BLDG 1801 SE DOOR OF NEW WHSE WEST DOOR OF NEW WHSE SW DOOR OF NEW WHSE NORTH WALL, 2ND FLOOR NEW WHSE INTAKE PUMPS SOUTH SIDE CLARIFIER PLATFORM WEST WALL OUTSIDE SW DOOR BLDG 1801 WEST ACID NEUTRALIZATION TANK BY MCC BASE OF STAIRS IN WAREHOUSE W WALL OUTSIDE NW DOOR BLDG 1801 E DOOR WHSE FIREWATCH E DOOR WHSE FIREWATCH BLDG. 1804 MCC E DOOR MCC BLDG 1804 BLOCK 35 WATER TREATING CLARIFIER AREA 00 A 117099 CONFIDENTIAL 1 10# FORAY 2 15# C02 3 20# DRY CHEMICAL STA NO 1 2 3 4 5 6 TYPE 15# C02 15# 002 20# DC 20# DC 20# DC 10# FORAY LOCATION HST COMMENTS CENTER DOOR CONTROL ROOM WEST DOOR CONTROL ROOM (OUTSIDE) WEST STAIRS TO CLARIFIER SE STAIRS TO CLARIFIER WEST STAIRWAY TO INTAKE PUMPS AND CHEMICAL FEED OUTSIDE BLDG 3502-T STA. NO 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 TYPE 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 15# C02 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 20# DC 15# C02 20# DC 15# C02 SUB STATIONS & WATER WELLS 1 10#FORAY 19 15# C02 10 20# DC 1 50# C02 LOCATION SE CORNER BLK 26 - SS #1 SE CORNER BLK 36 - SS #2 SE CORNER BLK 38 - SS #3 SW CORNER BLK 46 - SS #4 N END OF GLYCOL ROAD - SS #5 SE CORNER BLK 29 - SS #6 BLK 9 BLDG 920 (OUTSIDE) - SS #7 SE CORNER BLK 17 - SS #8 E WALL OUTSIDE BLK 47 - SS #10 NW CORNER BLK 47 - SS #10 BLOCK 8 - WW #1 BLOCK 28-WW #2 BLOCK 48-WW #3 BLOCK 45-WW #4 BLOCK 86 - WW #5 BLOCK 80 - WW #6 BLOCK 110-WW #7 ACROSS FROM GATE 4 - WW #8 BLOCK 56 - WW #9 RETURN PUMP SUB STATION GAS METERING STATION BLK 48 RETURN PUMP MOTOR PLATFORM HST COMMENTS DO A 117100 CONFIDENTIAL 23 50# C02 INTAKE PUMP PLATFORM 24 15# C02 INTAKE PLATFORM NORTH RAIL 25 15# C02 INTAKE PLATFORM WEST RAIL 26 15# C02 INTAKE PLATFORM ENTRANCE SOUTH 27 10# FORAY ROVING OPERATOR TRUCK 29 15# C02 INTAKE LEVEE 30 15# C02 RETURN LEVEE 31 15# C02 NITROGEN (OUTSIDE GATE 9) 32 15# C02 GULF STATES SUB fINSIDEl S/DOOR *********** END *********** .xy\0\ ---------- ,,---------------------------------------- -------------- 170 TlMti- 9/mi Swum 1 - fen M1S7 Kou. UiMm N CHinuwMa A HLnimiw* ton *'***" UUCM1WI Hum Hull WMI (9M) Ml'MSl tax (smj isi-oan / ^PHOC ORDER TAKEN BY UUMJ W ^ULV-olc=; DATE OF ORDER <7-/2-<F*s CUSTOMER'S ORDER `N Sr*SC y?d7. 'Srv ?~ cs-7 /J/SO^sv'cSS7&r TERMS: Qoay work JOB NAME/NUMBER contract * - J06LOCATON job more ^--------------------------------------------------------------------------------------- STARTS DATE tOFfO extra ) mm > S.- jii3 AMOU ^IJI^l^cPTOMwoRtc ;; ^; s/* (ft fe s*- 1 //^^7^r/` -- /Op-dO #l^-o~/a&rue<*r </ ' 'sv ~Zt/ SZ-^TitJ. - . *rftO' ` e*Aj-c>*t. /2^T QyS / z, *>4*?) JSL 6- /Of/C-tf' - Se'1 /T?/-/ *fc<r y^C/A'C /?zt cO/Jl > z/v *$//- / * * /) /? /i T tv^ -? //c. / 1 /-?/' / d/sir/'A'f/' #?>* f A 2/*' $?/rf/Li S/CU/________________ 1 //s* <Je ^'C /??c U /3; >* ~Z3C r/~- /^ '/? 'vfA ^ 'dX 5> 'x^y^-^cJercS S?& c. ^f*~f>s*Kr T 7/6^?c* ------- - - ........ ^ ^ T1^-------- -- ^-----;--'-<--r-c--J-r--<-/ AS/vs/ 7" /fttyysO /Pyy^r s< /^n^U/Cc . . ri3^IomER(>IARGES ok 5 //'sis/0 7^' Z?AT y /'^5t5i<r/*t^ r, 5 76 < /0OdSS>y~ s*s V&f /% -rvV-j/v'^rr TOTAL OTHER LABOR */ HRS. RATE i~</? AMOUNT ^ -4-tfs9 C*sUS- A~x*=-'o3 C 7 6 W3 - DATE COMPLETED TOTAL MATERIALS Wo rkr nrrinrnH bv Q'T-.Q^ StnnntiifA -Aa / 1 hereby acknowledge the satisfactory completion of the above described work raoouci 2u //viMSiiK, cm, hub qmn fe Onto PHOWE TOU ntEM + W777SLJSC TOTAL LABOR TOTAL MATERIALS TOTAL OTHER (7lMa/Sf^ow TAX TOTAL DO A 117102 CONFIDENTIAL Bourgeois A AModatM, be. WMtwmian Ms* i -1 inff $ UCM rAMZptiMMS) -HMIM4M TO /^C? /2>c<s ^Z0V~? /4vZ~. <^/' &>t/~? <J[I} OOWOOOl (wext, _ _ OH30< TAKEN Y OAItOfOHDBl customs** order hjmct "\ EJeAY WORK CONTRACT MAKEJOB /NUMBER *?&/ >QaAi/ joblocaton ' > y _ &/<4 ze0& EXTRA jK _ ,. ig i- V joemof l ' mnvopKTE J /?u)ajAa)aa)ce g/<P /^V>Ct/r Ztjuc/f>/v ZP?>< <7^ 2>g ______^ mm /? / 0 &&* <r"' ! LABOR ' TOTAL OTHER -*'"r *- * ' V HRS. RATE AMOUNT > -2. ^ cr^ cc ^ ^ ^ c/^> '(/i.vr < c^cerr *>&-? DATE COMPLETED TOTAL MATERIALS woffc nrrinrori hy Q-r' CO signature ... -\ V^vA 1 hereby acknowledge the satisfactorf completion of the above described work. M (Mm PHOUt MU. ll + 0U&4 -------- _ TOTAL LABOR (. J 1 TOTAL MATERIALS ; TOTAL OTHER CEMat^y&w TAX TOTAL DO A 117103 CONFIDENTIAL. Bourgoob * Amodatot, toe. CXAJTOJIHCWM* Read 14117 oJ[D H[iW@D@ IW4J FAX (SM) Ul-OM* d2/jOcc^ > Si/'C'*-/* /^'V' -2<r<S-7 /*/ </&> *//- -Z*/7 TERMS: fcJPTTts: > ' *r** PRI ^PHOtC OiTIOFOFIDEB ^V-GFrS. "\ ORDER TAKEN BY 0-DAY WORK JOBNAk*/NUMBSt <?</-*&>/ CUSTOMER* OfCS / 7/?/7Q/__________ CONTRACT EXTRA &xo-*.JT /t^s- -z-e JOB LOCATION jOBmoec .> ?gr*S ' STARTING DATE V-S/- <Pes J i1 I 1* -r --w- AMOU ttl */ /??/ SS<J7nJS? si r f r* /^c/Cc^i &*_> /=r,/Z4.-j/-- 7/0 ^1'< /t* *. _ /r r /^UAJC./'es* 77* (77' ?/o /'-Tv-sOed. 0n*/rt*r ^ jdh M (*+ w^. >. i,vi*yyi.'gi yaaBFg' " " T f*_ -. . -- y. OTHER CHARGES 1 * /7/Z 777*5^ d/Ar (7 J^r/t yC? e~/<"/p5~ . *: TOTAL OTHER LABOR HRS. RATE AMOUNT > 2- i C^Gccrc, Z6 *? /TszTTti-r sO/f~- T>ctr<y 3d. 7 DATE COMPLETED 1 TOTAL MATERIALS | Woirtt ordered tav &T-..SK3'. Ml_____A____ 1 hereby Acknowledge the satisfactory completion of the above described work- "mow taxitm tun la 04* WOW mi ftf I + fcnmiiw I I TOTAL LABOR TOTAL MATERIALS TOTAL OTHER C3Kan^f^ow TAX TOTAL QQ ^ CONFIDFNTTAL